Construction and performance of a new catheter-tip oxygen electrode.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to G Kwant.
Explore the source record for details and available documents.
To be able to determine the slight differences between the theoretical and the actual O2-binding capacity of human haemoglobin, a highly accurate method has been developed for measuring the O2 content of blood samples. It is an adaptation of an established O2 determination in organic microanalysis. The bound O2 of the blood is set free by conversion of HbO2 to Hi, and the O2 stripped from the blood is converted to CO by contact with granular carbon at 1120 degrees C. The CO is then converted to CO2 using CuO at 300 degrees C and the CO2 titrated in a solution of BaCl2, using NaOH of known strength. The measuring system was checked by analysis of 36 samples of air, yielding an O2 content of 20.93 +/- 0.06%. The coefficient of variation calculated from 62 duplicate determinations of samples of human blood was 0.65%.
The absorption spectrum of indocyanine green depends on the nature of the solvent medium and on the dye concentration. Binding to plasma proteins causes the principal peaks in the absorption spectrum to shift about 25 nm toward the higher wavelengths. The much greater influence on the spectrum of the dye concentration results from progressive aggregate formation with increasing concentration. Indocyanine green solutions therefore do not follow Lambert-Beer's law above 15 mg-I-1 (in plasma). Indocyanine green solutions in plasma and concentrated (1,000 mg-I-1) solutions in distilled water are stable for at least 4 h. In long-term experiments the optical density of indocyanine green solutions in plasma as well as in distilled water generally diminishes, even in the dark. On the 7th day a new absorption maximum starts to appear at gamma=900 nm, possibly caused by further aggregate formation leading to much larger particles. Spectral stabilization after injection of a concentrated solution into the blood is most rapid when the dye is dissolved in distilled water. Spectral stabilization slows down with decreasing temperature. As rapid spectral stabilization is essential in quantitative dye dilution studies, the practice of adding a albumin and/or isotonic saline solution to the injectate should be discontinued. When a 10 g-1(-1) aqueous solution of indocyanine green is used, spectral stabilization takes less than 1.5 a (at 37 degrees C), which is sufficiently fast for almost any application.
Explore the source record for details and available documents.