PubMed Health⌕ Search

Biomedical subjects

G L Greenslade

Publications and source records attributed to G L Greenslade.

13 recordsLinked to original sources

Mid-latency auditory evoked response during propofol and alfentanil anaesthesia.

BACKGROUND: Propofol has been shown to affect the mid-latency auditory evoked response (MLAER) in a dose-dependant manner. Few studies have investigated the addition of alfentanil. Myogenic responses, such as the post-auricular responses (PAR), can confound the MLAER but there has been little investigation as to which electrode site reduces this interference. METHODS: We studied the MLAER in 27 women. They received an infusion of alfentanil 15 micro g kg(-1) h(-1), followed by either a high or low infusion regimen of propofol (final infusion rates 6 and 3 mg kg(-1) h(-1)). We compared the results with those of our study using propofol alone. We collected the data from two electrode sites: vertex-inion and vertex-mastoid. We evaluated the occurrence of the PAR and the shape of the MLAER at each electrode site. RESULTS: The infusion rate of propofol associated with loss of the eyelash response in 50% of subjects was 3.3 mg kg(-1) h(-1). This was significantly lower than using propofol alone (5.8 mg kg(-1) h(-1)). Nb latency was the best MLAER discriminator of unconsciousness (sensitivity 94%, specificity 88%), with a threshold of 46 ms (propofol alone was 53 ms). The addition of alfentanil did not alter the relationship between propofol infusion rate and MLAER. The vertex-inion electrode site gave the best protection against PAR in awake subjects (P=0.0003), and after 30 min of propofol infusion (P=0.06). The magnitude of the MLAER obtained from the vertex-mastoid electrodes was larger than from the other site, although the increase was not consistent throughout the waveform (brain stem 100%, Nb 14%). CONCLUSIONS: Addition of alfentanil lowers the propofol infusion rate required to produce unconsciousness and the Nb latency that predicts it. The better of the two sites to reduce the incidence of PAR is the vertex-inion electrode site.

Alfentanil↗

Concentration-related effects of propofol on the auditory evoked response.

We have studied the effects of propofol, as the sole agent, at blood concentrations of 1-10 micrograms ml-1, on the first 100 ms of the auditory evoked response (AER) in 41 women before gynaecological surgery. AER were recorded with the patients awake and then after 30 min of one of seven stepped infusion regimens. Each patient was studied at only one blood concentration. The recordings were edited and processed off-line by coherent signal averaging, to obtain reliable estimates of each AER. We measured standard features, such as amplitudes and latencies of brainstem wave V and the mid-latency waves Na, Pa and Nb. In addition, we studied several composite indices, intended to give a more global characterization of the AER. We derived relationships between the doses and blood concentrations of propofol, features of the AER and response to eyelash stimulus and venepuncture. Nb latency was better than either concentration or dose rate of propofol in providing a confident explanation of the likelihood of eyelash response (which parallels the response to command). A cut-off value of 53 ms had a sensitivity of 100%, a specificity of 96% and an overall correctness of 98% as a discriminator of eyelash response vs no response. Several alternative AER-derived indices provided more than 90% correctness in discrimination, as did a dose rate of propofol of 6.3-7.8 mg kg-1 h-1 or a blood concentration of 2.9 micrograms ml-1. We conclude that the concentration and dose of propofol were good discriminators of response to venepuncture, while the latency of the Na wave was the most successful of the AER features.

Adult↗

Advanced Trauma Life Support aboard RFA Argus.

The Advanced Trauma Life Support (ATLS) system was adopted for casualty reception and resuscitation. ATLS permitted well-informed triage decisions to be made, coupled with appropriate initial, possibly life-saving, treatment. The training given on board has continued to benefit patients treated by ex-Argus staff in their peacetime roles.

Humans↗

Single operator cardiopulmonary resuscitation in ambulances. Which ventilation device?

Cardiopulmonary resuscitation en route to hospital is performed by a single-handed operator in many British ambulances. In this study, three emergency ventilation devices, and mouth-to-mouth breathing, were compared for effectiveness in unintubated patients. Seventeen paramedics used each method on a Laerdal manikin in a randomised order, under identical conditions. Three experienced cardiopulmonary resuscitation instructors repeated the tests in a moving ambulance. There were significant differences in minute volume (p less than 0.01) and number of effective chest compressions (p less than 0.05); mouth-to-mouth breathing produced the best overall results and the simplest device was a close second. The value of automatic ventilators for single-operator cardiopulmonary resuscitation in unintubated patients is questioned.

Ambulances↗

Laryngeal mask airway and tracheal tube insertion by unskilled personnel.

After a short training programme 11 naval medical trainees inserted a laryngeal mask airway (LMA) and a tracheal tube (ETT) in random order in a total of 110 anaesthetised patients. They were allowed 40 s for each attempt. Success was defined as the detection of expired carbon dioxide within 40 s of Guedel airway removal which subsequently rose to an end-tidal value of at least 4 kPa, together with satisfactory lung expansion and ventilation, without other airway intervention by the anaesthetist. 104 LMA insertions were successful compared with 56 of ETTs (p less than 0.01). All first attempts at LMA insertion were successful, whereas satisfactory ETT placement was progressive. Insertion was also quicker with the LMA (20 s) than with the ETT (35 s) (p less than 0.01). Further studies are indicated to assess the value of the LMA in emergencies.

Airway Obstruction↗