PubMed Health⌕ Search

Biomedical subjects

G L Savage

Publications and source records attributed to G L Savage.

6 recordsLinked to original sources

A comparison of noninvasive objective and subjective measurements of the optical density of human ocular media.

BACKGROUND: It is important for both researchers and clinicians to know the spectral composition of the light that reaches the retina. With this in mind, Johnson et al. developed a quick, objective instrument called the Lens Absorption Monitor (LAM) to measure the attenuation of light by the ocular media. Using a more refined method of measuring and correcting for scatter, we compared the results of the LAM against those with a subjective method utilizing a bipartite scotopic brightness-matching procedure (BIP). METHODS: We tested 41 healthy subjects (mean age, 35.9 years) with the LAM and BIP. RESULTS: Intereye correlation coefficients for the LAM were 0.70 at 410 nm and 0.83 at both 430 and 450 nm; for BIP, intereye correlation coefficients were 0.56 at 410 nm, 0.42 at 430 nm, and 0.38 at 450 nm. For optical density as a function of age, there was no statistically significant difference between the two instruments at 410 nm in either the slope (p > 0.43) or y intercept (p > 0.75). However, at both 430 and 450 nm, there was a significant difference in both slope (p < 0.001) and y intercept (p < 0.05) for the two instruments. CONCLUSIONS: With the latest refinements, LAM density measures correlated well with BIP estimates at 410 nm, but not at 430 or 450 nm. This underscores the fact that the LAM measures the spectral density of the anterior segment, whereas the BIP method is a measure of all the ocular media except for macular pigment. The difference between these two measures is consistent with the existence of a prereceptoral, presumably intraretinal, pigment (or pigments) located outside the anatomic fovea that absorbs light at short wavelengths.

Accommodation, Ocular↗

Temporal summation for grating patches detected at low light levels.

It is not known if temporal integration for periodic stimuli is affected by changes in scotopic luminance. Contrast thresholds were measured as a function of duration for 0.25 cpd grating patches across a 2.3 log-unit scotopic range. Threshold vs. duration (TVD) functions were identical in shape regardless of mean luminance once scaled by translating along log-log axes. Critical duration decreased 0.09 log-units per log-unit increase in retinal illuminance. This slope is identical to that reported for photopic conditions, suggesting that temporal integration may be determined by the same neural pathway at all light levels.

Adult↗

S-cone sensitivity in unilateral aphakia.

BACKGROUND: Exposure to ultraviolet radiation (UVR) and blue light has been shown to cause retinal damage in animals. In humans, it has been argued that the loss of short-wavelength (S) cone sensitivity during normal aging may be related to chronic light exposure. METHODS: We measured sensitivity to blue and yellow lights presented on bright yellow backgrounds at several retinal eccentricities in both eyes of an observer with long-standing unilateral aphakia. RESULTS: For yellow lights, where media absorption is not a major factor, there was a 2-fold loss in sensitivity of long (L) and medium (M) wavelength cone mechanisms in the aphakic eye relative to the phakic eye. For blue lights detected by S-cones, there was a 10-fold loss of S-cone mechanism sensitivity in the aphakic eye, after differences in ocular media density were taken into account. CONCLUSIONS: Our findings strongly support the hypothesis that chronic exposure to short wavelength radiation impairs S-cone function.

Adult↗

Scotopic visual efficiency: constraints by optics, receptor properties, and rod pooling.

We studied the influence of optics, photoreceptor properties, and rod pooling on scotopic contrast sensitivity by comparing the performance of an ideal discriminator to that of human observers. Comparisons of human and ideal contrast sensitivities indicated that preretinal factors and summation area were not sufficient to explain the shape of the human CSF. Spatial pooling of rods was explored as a possible explanation of this discrepancy. Our highest efficiency, expressed in terms of a human/ideal contrast sensitivity ratio, was about 1:3 (0.33) for a contrast discrimination task.

Adult↗

Measurement of metamorphopsia in the presence of ocular media opacities.

Opacities in the cornea, crystalline lens, and vitreous may make conventional measurements of retinal/visual function of little value. Here, we present two psychophysical hyperacuity tests that are designed to detect and quantify retinal distortions even in the presence of substantial opacities. One test makes use of a two-dot vernier display in which directional bias as well as vernier acuity can be estimated. The second test is a multi-dot hyperacuity bisection task, which resembles a simplified Amsler grid test. By varying the spatial parameters of these stimuli, metamorphopsia may be quantified. The method is applicable both in clear and occluded ocular media.

Adult↗

Drusen of the optic nerve head. An important model.

It is proposed that drusen of the optic nerve head (ONH) may provide a useful model for the study of diseases which affect the vicinity of the optic disc. Several sensitive and revealing tests of inner retinal/optic nerve function have been applied in this investigation. Fundus Photo Perimetry has confirmed that little correlation exists between visual field defects and the location of ophthalmoscopically visible ONH drusen. The Flashing Repeat Static Test (FRST) was found to be abnormal in half of our patients, indicating probable ascending dysfunction in optic nerve fibers beyond the lamina cribrosa. Alterations in transient-like and/or sustained-like functions, found in several cases, are thought to represent effects of dysfunction descending to the retinal plexiform layers.

Adult↗