The human pattern ERG: alteration of response properties with aging.

The influence of aging on both the amplitude and the latency of transient and steady-state pattern electroretinograms (PERG's) was studied in 80 healthy participants ranging from 25 to 77 years of age (mean age, 55.3 years). Responses to counterphasing checkerboard patterns were recorded for each of 7 test conditions in which the spatial (i.e., check sizes 0.25, 0.50, 1.00, and 2.00 degrees) and temporal characteristics (i.e., counterphasing at either 2, 4, 8, or 16 rps) of the stimuli were varied. For both the transient and steady-state PERG's amplitude was inversely related to age (p less than 0.05 for each test condition). In general, PERG latency directly correlated with age, but this effect was less robust (p less than 0.05 for one transient condition and three of the four steady-state conditions). The influence of age on the spatial tuning of the PERG was minimal; the decrease in PERG amplitude and the increase in PERG latency as a function of age were essentially the same for all test conditions. However, the magnitude of the age-related reduction in PERG amplitude was observed to vary with temporal frequency, being largest for the steady-state condition (16 rps). The results from an experiment in which young subjects were tested while wearing opaque contact lenses with 2-mm artificial pupils suggest that senile miosis is a significant factor contributing to the age-related PERG amplitude and latency changes, but it does not fully account for the observed changes.

Adult

The pattern electroretinogram in retinal and optic nerve disease. A quantitative comparison of the pattern of visual dysfunction.

A retrospective analysis was performed on the transient and steady-state pattern electroretinograms recorded from 42 patients with glaucoma, 13 patients with senile dementia of the Alzheimer's type, 58 patients with diabetes mellitus, and 92 control subjects to evaluate the pattern of electroretinographic changes associated with retinal and optic nerve disease. The amplitudes of both the initial positive component (N1 to P1) and the subsequent negative component (P1 to N2) of the transient (4 rps) responses were measured. From these measurements the (P1 to N2)/(N1 to P1) was derived. The N1 to P1 amplitude of the steady-state pattern electroretinogram also was measured. In the glaucoma patients all three amplitude measures, as well as the amplitude ratio of the components of the transient response, were reduced significantly compared with age-matched controls (p less than 0.05). A similar pattern was detected in the patients with Alzheimer's disease, but in this case the only statistically significant amplitude reduction was in the steady-state pattern electroretinogram. A different pattern was observed among the diabetic patients (both with and without retinopathy). Only minor reductions in the amplitude of the transient pattern electroretinogram, which were not statistically significant, were noted. In addition, the ratio of the amplitudes of the components of the transient response did not differ from age-matched controls. The amplitude of the steady-state pattern electroretinogram was reduced in diabetics, but this was significant only for those patients with retinopathy (p less than 0.01). These findings support the suggestion that an analysis of both the positive and negative components of the pattern electroretinogram may be useful for differentiating the contributions of retinal and optic nerve dysfunction to visual impairment. The results also indicate that in both retinal and optic nerve disease the steady-state pattern electroretinogram can be an earlier sign of dysfunction than the transient pattern electroretinogram.

Adult

Improved electrode for electroretinography.

Corneal electrodes useful for clinical electroretinography require topical anesthesia, interfere with vision, can abrade, and are not well accepted by most children and many adults. A low mass conductive thread, corneal (DTL) electrode is described and comparatively tested against the Burian-Allen electrode. The DTL electrode was found to have few of the limitations of the hard contact lens electrode. Furthermore, the DTL electrode signal quality was comparable to that of the Burian-Allen electrode and provided less between-patient variability.

Adult