PubMed Health⌕ Search

Biomedical subjects

G Lettinga

Publications and source records attributed to G Lettinga.

At least 37 records · Page 2Linked to original sources

Effects of trace element addition on volatile fatty acid conversions in anaerobic granular sludge reactors.

The effect of the addition of trace elements on the conversion of a mixture of volatile fatty adds (Acetate, Propionate, Butyrate, in a ratio 3:1:1) by anaerobic granular sludge was investiated. Two Upflow Anaerobic Sludge Bed reactors (pH 7, ranging 30 degrees C) were operated for 140 days at an organic loading rate from 2 g COD l(-1) d(-1) up to 10 g COD l(-1) d(-1) and a hydraulic retention time of 12 hours. One reactor (R1) was supplied with a trace metal cocktail in the basal medium, whereas trace metals were omitted from the influent of the second reactor (R2). As a result, the trace metal concentration in the granules from R2 steadily decreased at a rate of 48 microg metal g(-1) TS d(-1) down to 35% of their initial value. In contrast, trace metals accumulated in granules present in R1. At the end of the experiment, the COD removal efficiencies were 99 and 77% for, respectively, the control (R1) and deprived (R2) reactors. This difference was due to lack of propionate conversion by sludge from R2. No difference in the acetate and butyrate conversion capacity of both reactors was observed. The conversion of acetate, propionate and methanol were stimulated by the continuous addition of metals to the influent, a sludge of R1 had higher maximum specific activity values compared to sludge of R2. However, both sludges had a similar maximum specific activity with butyrate. Surprisingly, maximum specific activity tests using individual trace metals showed that the addition of a particular trace element in the activity test medium did not affect the degradation rates of aspecific substrate, i.e. acetate, propionate, butyrate and methanol.

Bacteria, Anaerobic↗

Treatment of domestic sewage in a combined UASB/RBC system. Process optimization for irrigation purposes.

A Rotating Biological Contactor (RBC) was fed with raw domestic wastewater or anaerobic effluents. The experiments were conducted at increasing operational temperatures viz. 11, 20 and 30 degrees C to assess the potential increase in removal efficiencies for the different COD fractions (COD(total), COD(suspended), COD(colloidal) and COD(soluble)), E. coli and in the nitrification rate. The results clearly show that, the RBC at HRT of 2.5 h and OLR of 47 g COD/m2 x d provided a very high residual COD(total) value of 228 mg/l when treating domestic wastewater. This was not the case as compared to the results obtained for the system when operated at the same HRT but at lower OLR's of 27, 20 and 14.5 g COD/m2 x d with a UASB effluent at operational temperatures of 11, 20 and 30 degrees C respectively. The residual COD(total) values amounted to 100, 85 and 72 mg/l in the final effluents. Moreover, a high removal of ammonia and low residual values of E. coli was found for the RBC when treating a UASB effluent at operational temperature of 30 degrees C as compared to the situation for treatment of domestic wastewater and UASB effluent at lower temperatures of 11 and 20 degrees C. It can be concluded that an efficient pre-treatment of sewage implies a substantial reduction of OLR applied to the RBC and consequently improves the residual of COD(total) ammonia and E. coli in the final effluent. Therefore, this study supports using a combined system UASB/RBC for treatment of domestic wastewater for reuse in irrigation.

Ammonia↗

Sulfidogenic volatile fatty acid degradation in a baffled reactor.

The effect of staging the sludge bed on volatile fatty acid degradation by sulfidogenic reactors was evaluated in a baffled reactor. In a 5.4 l baffled reactor, containing three equal compartments, a volatile fatty acid (VFA) mixture (acetate:propionate:butyrate ratio 1:2:2 on COD basis; pH 8) was treated under mesophilic (30 degrees C) and sulfidogenic (COD:SO4(2-) ratio: 0.5) conditions for 38 days. At a specific sludge loading rate of 0.50 g COD.gVSS(-1) x d(-1), a COD and sulfate removal of 85% and 30%, respectively, was obtained. In the baffled reactor, staging of the sulfidogenic VFA degradation occurred. Propionate and butyrate were mainly degraded in the first compartment. Their degradation was incomplete, resulting in elevated acetate concentrations in compartment I. In the second and third compartment of the baffled reactor, a net degradation of acetate took place. Acetate was the sole substrate present in compartment III and residual acetate concentrations of about 200 mg/l were present in the effluent at a specific sludge loading of 0.50 g COD x gVSS(-1) x d(-1). Sludges with different maximum specific VFA and acetate degrading activities developed in the first and second compartment. These maximal specific activities were almost equal for sludge present in compartment II and III.

Acetates↗

Anaerobic digestion of solid animal waste in an accumulation system at mesophilic and thermophilic conditions, start up.

The anaerobic digestion of solid animal wastes has been studied in an accumulation system (AC) at a filling time of 60 days followed by about 50 days batch digestion at 40 and 50degrees C. Poor mixing conditions during anaerobic digestion of solid wastes promote stratification of the substrate and intermediate products along the reactor height. The effect of layers stratification has also been followed in the AC system. The results showed a pronounced stratification of both COD(dis) and VFA concentrations along the AC system height. The temperature had a minor effect on the methane yield. The results also showed that methanogenesis was rate limiting in the AC system while the hydrolysis was the rate-limiting step during batch digestion.

Animals↗

Enrichment and immobilization of quinone-respiring bacteria in anaerobic granular sludge.

The capacity of an anaerobic granular sludge for serving as an immobilizing mechanism for quinone-respiring bacteria was evaluated. The inoculum was continuously fed with a basal medium containing the humic model compound, anthraquinone-2,6-disulfonate (AQDS), as a terminal electron acceptor. Complete reduction of AQDS was achieved by the granular sludge for a prolonged period in an anaerobic bioreactor provided with a mixture of volatile fatty acids as a substrate. Phylogenetic analysis revealed the enrichment and immobilization of AQDS-respiring bacteria appearing as dominant organisms in the microbial population of the AQDS-supplemented reactor, compared to a reactor control operated under methanogenic conditions. The consistent quinone-reducing capacity observed in the consortium indicates that it is feasible to apply quinone-reducing microorganisms in continuous bioreactors and this ability can potentially be important in wastewaters rich in humic substances. The quinone reducing activity could also be applied to accelerate the conversion of xenobiotics susceptible to reductive biotransformations such as azo dyes and polychlorinated compounds in continuous bioreactors.

Bacteria, Anaerobic↗

Bicarbonate dosing: a tool to performance recovery of a thermophilic methanol-fed UASB reactor.

The thermophilic-anaerobic treatment of methanol-containing wastewater in an upflow anaerobic sludge blanket (UASB) reactor, was found to be quite sensitive to pH shocks, both acid and alkaline. The results of the recovery experiments of sludge exposed to an alkaline shock, indicated that the addition or deprivation of sodium bicarbonate (NaHCO3) in the medium, plays an important role in the competition of methanogens and (homo)acetogens for methanol. In addition, caution has to be taken when using NaHCO3 for buffering methanol-containing wastewaters, since its introduction in the system will favour (homo)acetogenesis when proper conditions are not established. Based on these results, a recovery strategy for methanogenesis was proposed where bicarbonate is supplied stepwise, and the reactor is operated in a batch mode. This strategy was found to be appropriate, i.e. the results revealed that the recovery of methanogenesis on methanol from a reactor upset or complete failure caused by pH shock is possible, even in systems where (homo)acetogens are outcompeting methanogens. The time and the number of feedings required will depend on the degree of deterioration of the sludge.

Bacteria, Anaerobic↗

Assessment of compatible solutes to overcome salinity stress in thermophilic (55 degrees C) methanol-fed sulfate reducing granular sludges.

High NaCl concentrations (25 g x L(-1)) considerably decreased the methanol depletion rates for sludges harvested from two lab-scale sulfate reducing UASB reactors. In addition, 25 gNaCl x L(-1) strongly affected the fate of methanol degradation, with clear increase in the acetate production at the expense of sulfide and methane production. The addition of different osmoprotectants, viz. glutamate, betaine, ectoine, choline, a mixture of compatible solutes and K+ and Mg2+, slightly increased methanol depletion rates for UASB reactors sludges. However, the acceleration in the methanol uptake rate favored the homoacetogenic bacteria, as the methanol breakdown was steered to the formation of acetate without increasing sulfate reduction and methane production rates. Thus, the compatible solutes used in this work were not effective as osmoprotectants to alleviate the acute NaCl toxicity on sulfate reducing granular sludges developed in methanol degrading thermophilic (55 degrees C) UASB reactors.

Bacteria, Anaerobic↗

Decentralised treatment of concentrated sewage at low temperature in a two-step anaerobic system: two upflow-hybrid septic tanks.

The decentralised treatment of concentrated sewage (about 3,600 mgCOD/l) at low temperature was investigated in a two-step anaerobic system: two-anaerobic hybrid (AH) septic tanks (each 0.575 m3). The two reactors were placed in a temperature controlled-room and the HRT was 2.5 days for each reactor. The system was fed with concentrated domestic sewage, mainly black water from about 40 toilets flushed with only 4 litre of water and a limited amount of grey water. The system showed high removal efficiency for the different COD fractions. Mean removal efficiencies in the two-step AH-septic tank at 5 days HRT and 13 degrees C were 94, 98, 74 and 78% for total COD, suspended COD, colloidal COD and dissolved COD respectively. The results of short run experiments indicated that the presence of reticulated polyurethane foam (RPF) media in the AH-septic tank improved the removal of suspended COD by 22%. The first AH-septic tank was full of sludge after 4 months of operation due to the high removal of particulate COD and the limited hydrolysis at low temperature conditions. Therefore, a simple mathematical model was developed based on ADM1 (the IWA model in 2002). Based on the experimental results and the mathematical model, only a one-step AH septic tank is required. An HRT of 5.5-7.5 days is needed for that one-step AH septic tank to treat concentrated sewage at a low temperature of 13 degrees C. Such a system can provide a total COD removal as high as 87% and will be full of sludge after a period of more than a year.

Bacteria, Anaerobic↗

Treatment of domestic sewage at low temperature in a two-anaerobic step system followed by a trickling filter.

The treatment of domestic sewage at low temperature was studied in a two-anaerobic-step system followed by an aerobic step, consisting of an anaerobic filter (AF) + an anaerobic hybrid (AH) + polyurethane-foam trickling filter (PTF). The AF+AH system was operated at a hydraulic retention time (HRT) of 3+6 h at a controlled temperature of 13 degrees C, while the PTF was operated without wastewater recirculation at different hydraulic loading rates (HLR) of 41, 15.4 and 2.6 m3/m2/d at ambient temperature (ca. 15-18 degrees C). The AF reactor removed the major part of the total and suspended COD, viz. 46 and 58% respectively. The AH reactor with granular sludge was efficient in the removal and conversion of the anaerobically biodegradable COD. The AF+AH system removed 63% of total COD and converted 46% of the influent total COD to methane. At a HLR of 41 m3/m2/d, the COD removal was limited in the PTF, while at HLR of 15.4 and 2.6 m3/m2/d, a high total COD removal of 54-57% was achieved without a significant difference between the two HLRs. The PTF was mainly efficient in the removal of particles (suspended and colloidal COD removal were 75-90% and 75-83% respectively), which were not removed in the anaerobic two-step. The overall total COD removal in the AF+AH+PTF system was 85%. Decreasing the HLR from 15.4 to 2.6 m3/m2/d, only increased the nitrification rate efficiency in the PTF from 22% to 60%. Also, at HLR of 15.4 and 2.6 m3/m2/d, PTF showed a similar removal for E. coli by about 2 log. Therefore, the effluent of AF+AH+PTF system can be utilised for restricted irrigation in order to close water and nutrients cycles. Moreover, such a system represents a high-load and a low-cost technology, which is a suitable solution for developing countries.

Bacteria, Anaerobic↗

Conversion and toxicity characteristics of formaldehyde in acetoclastic methanogenic sludge.

An unadapted mixed methanogenic sludge transformed formaldehyde into methanol and formate. The methanol to formate ratio obtained was 1:1. Formaldehyde conversion proceeded without any lag phase, suggesting the constitutive character of the formaldehyde conversion enzymes involved. Because the rate of formaldehyde conversion declined at increased formaldehyde additions, we hypothesized that some enzymes and/or cofactors might become denatured as a result of the excess of formaldehyde. Furthermore, formaldehyde was found to be toxic to acetoclastic methanogenesis in a dual character. Formaldehyde toxicity was partly reversible because once the formaldehyde concentration was extremely low or virtually removed from the system, the methane production rate was partially recovered. Because the degree of this recovery was not complete, we conclude that formaldehyde toxicity was partly irreversible as well. The irreversible toxicity likely can be attributed to biomass formaldehyde-related decay. Independent of the mode of formaldehyde addition (i.e., slug or continuous), the irreversible toxicity was dependent on the total amount of formaldehyde added to the system. This finding suggests that to treat formaldehyde-containing waste streams, a balance between formaldehyde-related decay and biomass growth should be attained.

Acetates↗

Assessment of effluent turbidity in mesophilic and thermophilic activated sludge reactors - origin of effluent colloidal material.

Two lab-scale plug flow activated sludge reactors were run in parallel for 4 months at 30 and 55 degrees C. Research focussed on: (1) COD (chemical oxygen demand) removal, (2) effluent turbidity at both temperatures, (3) the origin of effluent colloidal material and (4) the possible role of protozoa on turbidity levels. Total COD removal percentages over the whole experimental period were 66+/-7% at 30 degrees C and 53+/-11% at 55 degrees C. Differences in total COD removal between both systems were due to less removal of soluble and colloidal COD at 55 degrees C compared to the reference system. Thermophilic effluent turbidity was caused by a combination of influent colloidal particles that were not effectively retained in the sludge flocs, and erosion of the thermophilic activated sludge itself, as shown by denaturing gradient gel electrophoresis (DGGE) profiles. DGGE analysis of PCR-amplified 16S rDNA fragments from mesophilic and thermophilic sludge differed, indicating that different microbial communities were present in the two reactor systems. The effects of protozoal grazing on the effluent turbidity of both reactors was negligible and thus could not account for the large turbidity differences observed.

Animals↗

Assessment of metabolic properties and kinetic parameters of methanogenic sludge by on-line methane production rate measurements.

This report presents a new approach to studying the metabolic and kinetic properties of anaerobic sludge from single batch experiments. The two main features of the method are that the methane production is measured on-line with a relatively cheap system, and that the methane production data can be plotted as rate vs time curves. The case studies of specific methanogenic activity, biodegradability and toxicity tests here presented show that very accurate kinetic data can be obtained. The method is specifically useful in experiments in which strong changes in methane production occur, and it is proposed as a powerful tool to study methanogenic systems. Furthermore, the method is simple and could be implemented by industry in the routine analysis of sludge.

Anaerobiosis↗

Effect of nickel deprivation on methanol degradation in a methanogenic granular sludge bioreactor.

The effect of omitting nickel from the influent on methanol conversion in an Upflow Anaerobic Sludge Bed (UASB) reactor was investigated. The UASB reactor (30 degrees C, pH 7) was operated for 261 days at a 12-h hydraulic retention time (HRT) and at organic loading rates (OLRs) ranging from 2.6 to 7.8 g COD l reactor(-1) day(-1). The nickel content of the sludge decreased by 66% during the 261-day reactor run because of washout and doubling of the sludge bed volume. Nickel deprivation initially had a strong impact on the methanogenic activity of the sludge with methanol; e.g., after 89 days of operation, this activity was doubled by adding 2 micro M nickel. Upon prolonged UASB reactor operation, methanol and VFA effluent concentrations decreased whereas the sludge lost its response to nickel addition in activity tests. This suggests that a less nickel-dependent methanol-converting sludge had developed in the UASB reactor.

Anaerobiosis↗

Sludge accumulation in polishing ponds treating anaerobically digested wastewater.

When ponds are used for wastewater treatment, settleable solids will form a steadily growing bottom sludge layer, which reduces their effective volume. Eventually this sludge must be removed to ensure that the pond maintains the required retention time to keep performing properly. The settleable solids may either be present in the influent or they are formed during the treatment as a result of algal flocculation. An experimental investigation was carried out to evaluate bottom sludge accumulation in a polishing pond used for treatment of UASB effluent. The mass and composition of the bottom sludge formed in a polishing pond was evaluated after the pilot scale pond had been in operation for 1 year and about 60 m3 of digested wastewater had been treated per m3 of pond. The bottom sludge mass represented a solids accumulation of 70 g per m3 of digested wastewater. About half of these solids were the result of settling of influent solids in the first part of the pond, while the other half was attributable to settling of algae, formed in the pond. It is concluded that the bottom sludge growth in a polishing pond is so low, that desludging during the useful life span of the pond will most likely not be necessary. This leads to the important conclusion that excess sludge discharge from UASB reactors (a major factor in operational costs) may be omitted, if a polishing pond is used for post-treatment. The bottom sludge had a high volatile solids concentration (58%) and the macronutrient fractions were also high (3.9% N and 1.1% P of the TSS mass). The bottom sludge was stable and could be dried directly without problems. The hygienic quality of the bottom sludge was very poor: about half the influent helminth eggs during one year of operation were found in the bottom sludge and the faecal coliform concentration was very high.

Animals↗

Effect of high salinity on the fate of methanol during the start-up of thermophilic (55 degrees C) sulfate reducing reactors.

Two 6.5 L lab-scale upflow anaerobic sludge bed (UASB) reactors were operated at 55 degrees C fed with methanol as the sole electron and carbon source and in excess of sulfate (COD/SO4(2-) of 0.5) in order to investigate the effect of high wastewater salinity on the start-up period. The first reactor (UASB I) was operated without NaCl addition, while the second reactor (UASB II) was fed with 25 g x L(-1) of NaCl in the first 13 days of operation. Successful start-up of UASB I was achieved, with full methanol conversion (100% elimination) to methane gas (methane production rate up to 3.66 gCOD.L(-1).day(-1)). Despite the detection of sulfide from day 15 onwards in UASB I, methane was the main mineralization product when operating at an organic loading rate (OLR) of 5 gCOD.L(-1).day(-1) and a hydraulic retention time (HRT) of 10 hours. Sulfide and acetate started to be produced after salt omission from the influent in UASB II at day 13, with no detection of methane. Acetate was the main product when operating at an OLR of 10 gCOD.L(-1).day(-1) and HRT of 6.5 hours in both reactors. Apparently, the methane producing bacteria (MPB) are the trophic group most sensible to the NaCl shock.

Bioreactors↗

Start-up of a thermophilic methanol-fed UASB reactor: change in sludge characteristics.

Experiments were performed to study the change in sludge characteristics and sludge granulation during the start-up of a thermophilic methanol-fed upflow anaerobic sludge bed (UASB) reactor. The laboratory scale reactor, was inoculated with thermophilic granular sludge and operated at 55 degrees C over 130 days at organic loading rates (OLR) varying from 2.7 to 47 gCOD.L(-1).d(-1). Physical characterisation was performed for both the seed and the cultivated sludge. Results demonstrated that a good quality, well settleable granular sludge was cultivated and retained in the reactor, allowing an OLR of 47 gCOD.L.d(-1) with 93% of methanol removal, where 79% was converted into methane. Using a community analysis of the cultivated consortia, high numbers of rod-shaped hydrogenotrophic methanogens were enumerated. Biomass washout coincided with a high specific gas load, but was not detrimental to the system in the conditions tested.

Bacteria, Anaerobic↗

Treatment of fish processing wastewater in a one- or two-step upflow anaerobic sludge blanket (UASB) reactor.

The performance of one-step UASB reactors treating fish processing wastewater of different lipid levels was determined using artificially generated influent simulating that of the canning of sardines and tuna. The organic loading rates (OLR) and the hydraulic retention times (HRT) were 5-8 g COD.l(-1).d(-1) and 11-12 hours, respectively. In treating a wastewater that contains 3-4 g.l(-1) total COD of which 5-9% was lipids, the COD removal and conversion to methane were ca.78% and 61%, respectively. In treating a wastewater with a higher lipid content (ca. 47% of the total COD), the total COD removed and converted to methane were 92% and 47%, respectively. A considerable part of the influent total COD was removed via adsorption on reactor surfaces and sludge particles. The adsorption of lipids on sludge particles threatens the stability of the UASB operation. Thus, the performance of a first-step UASB reactor in removing suspended solids (SS) from a "high-lipid" wastewater was also determined in this study.

Animals↗

Removal efficiency and methanogenic activity profiles in a pilot-scale UASB reactor treating settled sewage at moderate temperatures.

The performance of a sewage treatment system consisting of a settler followed by an Upflow Anaerobic Sludge Bed (UASB) reactor is described. Mean ambient and sewage temperature were 16.5 and 21.6 degrees C, respectively. Total Chemical Oxygen Demand (CODt) concentration averaged 224.2 and 152.6 mg/L, for raw and settled sewage, respectively. The effluent concentration was 68.5 mgCODt/L. Total and suspended COD removal efficiencies of approximately 70 and 80%, respectively, have been observed in the system at a mean Hydraulic Retention Time (HRT) of 2 + 5 h. Maximum COD removal efficiency was achieved in the UASB reactor when upflow velocity (Vup) was 0.43 m/h (HRT = 6 h). Mean Specific Methanogenic Activity (SMA) and Volatile Suspended Solids (VSS) concentration in the granular sludge bed were 0.11 gCOD-CH4/gVSS.d and 30.0 gVSS/Lsludge, respectively. SMA was inversely related to VSS concentration, and both parameters varied along the sludge bed height. The Solids Retention Time (SRT) in the reactor was 450 days. Sludge characteristics have not been affected by changes of up to one month in Vup in the range 0.28-0.85 m/h (HRT 3-9 h). This system or two UASB reactors in series could be an alternative for sewage treatment under moderate temperature conditions.