PubMed Health⌕ Search

Biomedical subjects

G M Barnas

Publications and source records attributed to G M Barnas.

77 records · Page 5Linked to original sources

Respiration during hyperthermia in the chicken as influenced by an increase in inhaled CO2.

Respiratory rate was measured in unanesthetized, adult hens when abruptly exposed to 1.5% CO2 as they were responding to an environmental temperature of 38 C. Inhalation of 1.5% CO2 greatly depressed respiratory rate at high panting rates, but produced only slight changes during the lower, but sharply increasing, rates of respiration. The initial portion of the panting response appears to be mostly controlled by the respiratory drive initiated by thermoreceptors while higher respiratory rates seem to be more affected by chemical changes.

Animals↗

Are avian intrapulmonary CO2 receptors chemically modulated mechanoreceptors or chemoreceptors?

Openings of paleopulmonic parabronchi in paralyzed, unidirectionally ventilated geese were photographed through small holes in the birds' mediodorsal secondary bronchi during single-unit recording from intrapulmonary CO2 receptors. Changes in the discharge frequency of the receptors as fractional CO2 concentration of ventilating gas was alternated between 0 and 0.05 were compared with the changes in cross-sectional areas of randomly selected parabronchial lumina. Intrapulmonary CO2 receptors, similar to those found in other avian species, are also present in geese. Changes in intrapulmonary CO2 concentration greatly influenced the discharge of these receptors but did not induce movement of parabronchial smooth muscle in this region of the lung. If most of the receptors are located in the paleopulmonic parabronchi, as currently appears to be the case, we must conclude that changes in receptor discharge in response to changes in intrapulmonary CO2 concentration do not result from mechanical distortion of the receptors induced by smooth muscle contraction; intrapulmonary CO2 receptors appear to be true chemoreceptors.

Action Potentials↗

Assessment of time-domain analyses for estimation of low-frequency respiratory mechanical properties and impedance spectra.

Time-domain estimation has been invoked for tracking of respiratory mechanical properties using primarily a simple single-compartment model containing a series resistance (Rrs) and elastance (Ers). However, owing to the viscoelastic properties of respiratory tissues, Rrs and Ers exhibit frequency dependence below 2 Hz. The goal of this study was to investigate the bias and statistical accuracy of various time-domain approaches with respect to model properties, as well as the estimated impedance spectra. Particular emphasis was placed on establishing the tracking capability using a standard step ventilation. A simulation study compared continuous-time versus discrete-time approaches for both the single-compartment and two-compartment models. Data were acquired in four healthy humans and two dogs before and after induced severe pulmonary edema while applying sinusoidal and standard ventilator forcing. Rrs and Ers were estimated either by the standard Fast Fourier Transform (FFT) approach or by a time-domain least square estimation. Results show that the continuous-time model form produced the least bias and smallest parameter uncertainty for a single-compartment analysis and is quite amenable for reliable on-line tracking. The discrete-time approach exhibits large uncertainty and bias, particularly with increasing noise in the flow data. In humans, the time-domain approach produced smooth estimates of Rrs and Ers spectra, but they were statistically unreliable at the lower frequencies. In dogs, both the FFT and time-domain analysis produced reliable and stable estimates for Rrs or Ers spectra for frequencies out to 2 Hz in all conditions. Nevertheless, obtaining stable on-line parameter estimates for the two-compartment viscoelastic models remained difficult. We conclude that time-domain analysis of respiratory mechanics should invoke a continuous-time model form.

Animals↗

Respiratory mechanics in the open chest: effects of parietal pleurae.

To understand how the parietal pleurae affect the mechanical behavior of the human respiratory system after the chest wall is opened by median sternotomy, we studied 18 anesthetized/paralyzed patients immediately before coronary artery bypass grafting surgery. Elastances and resistances of the total respiratory system (ETr, Rrs) were calculated from measurements of airway pressure and flow during mechanical ventilation in the frequency and tidal volume ranges of normal breathing. Elastances and resistances of the lungs (EL, RL), chest wall (Ecw, Rcw) were also estimated from measurements of esophageal pressure. Data were collected in the closed chest, after median sternotomy with the parietal pleurae intact and after the left parietal pleura was opened for internal mammary artery harvest. After sternotomy with pleurae intact (n = 14), Ers did not change but Rrs decreased (p < 0.05). Ecw (including the contribution of the pleurae) was higher than in the closed chest (p < 0.05) while EL and RL were lower (p < 0.05); Rcw did not change. Opening the left pleura (n = 10) decreased Ers (p < 0.05), but Rrs did not change. We conclude that the chest wall/pleurae compartment offers significant impedance to lung expansion after sternotomy and rib retraction, unless one pleura is opened.

Adult↗