Automatic registration of PET and CT studies for clinical use in thoracic and abdominal conformal radiotherapy.

AIM: Implementation and validation of an automatic registration method based on mutual information (MI) for the integration of thoracic and abdominal positron emission tomography (PET)/computed tomography (CT) studies, with the purpose to facilitate in a clinical context the inclusion of PET metabolic information in conformal radiotherapy (RT). METHODS: Registration was obtained by modeling a rigid spatial transformation between CT and PET transmission studies. The registration method was based on Normalized Mutual Information (NMI), by iteratively transforming the PET volume, until its optimal alignment to the CT study is achieved, in correspondence of the maximum of NMI. To avoid entrapment in local maxima and to improve convergence speed we introduced a multiresolution scheme. Accuracy of the proposed approach was investigated in experimental data, relative to phantom and patient studies, acquired in conditions similar to clinical situations. RESULTS: In phantom studies the mean error in the 3D space is 3.6 mm (range 3-4 mm) in thoracic region and 3.2 mm (range 2.9-3.7 mm) in abdominal region, considerably less than PET spatial resolution. In patient studies the spatial mean error increases with respect to phantom studies (5.4 mm and 5.2 mm for thorax and abdomen, respectively) but remains comparable to the PET spatial resolution. The accuracy of spatial realignment was thus found adequate for the registration of PET/CT registration, if good patient repositioning was adopted. CONCLUSIONS: The proposed registration method, based on MI, was validated for the integration of PET/CT studies of patients candidate for thoracic and abdominal conformal RT. The method is automatic and provided with a user interface, thus suitable for clinical use.

Abdominal Neoplasms↗

Fitting late rectal bleeding data using different NTCP models: results from an Italian multi-centric study (AIROPROS0101).

BACKGROUND AND PURPOSE: Recent investigations demonstrated a significant correlation between rectal dose-volume patterns and late rectal toxicity. The reduction of the DVH to a value expressing the probability of complication would be suitable. To fit different normal tissue complication probability (NTCP) models to clinical outcome on late rectal bleeding after external beam radiotherapy (RT) for prostate cancer. PATIENTS AND METHODS: Rectal dose-volume histograms of the rectum (DVH) and clinical records of 547 prostate cancer patients (pts) pooled from five institutions previously collected and analyzed were considered. All patients were treated in supine position with 3 or 4-field techniques: 123 patients received an ICRU dose between 64 and 70 Gy, 255 patients between 70 and 74 Gy and 169 patients between 74 and 79.2 Gy; 457/547 patients were treated with conformal RT and 203/547 underwent radical prostatectomy before RT. Minimum follow-up was 18 months. Patients were considered as bleeders if showing grade 2/3 late bleeding (slightly modified RTOG/EORTC scoring system) within 18 months after the end of RT. Four NTCP models were considered: (a) the Lyman model with DVH reduced to the equivalent uniform dose (LEUD, coincident with the classical Lyman-Kutcher-Burman, LKB, model), (b) logistic with DVH reduced to EUD (LOGEUD), (c) Poisson coupled to EUD reduction scheme and (d) relative seriality (RS). The parameters for the different models were fit to the patient data using a maximum likelihood analysis. The 68% confidence intervals (CI) of each parameter were also derived. RESULTS: Forty six out of five hundred and forty seven patients experienced grade 2/3 late bleeding: 38/46 developed rectal bleeding within 18 months and were then considered as bleeders The risk of rectal bleeding can be well calculated with a 'smooth' function of EUD (with a seriality parameter n equal to 0.23 (CI 0.05), best fit result). Using LEUD the relationship between EUD and NTCP can be described with a TD50 of 81.9 Gy (CI 1.8 Gy) and a steepness parameter m of 0.19 (CI 0.01); when using LOGEUD, TD50 is 82.2 Gy and k is 7.85. Best fit parameters for RS are s=0.49, gamma=1.69, TD50=83.1 Gy. Qualitative as well as quantitative comparisons (chi-squared statistics, P=0.005) show that the models fit the observed complication rates very well. The results found in the overall population were substantially confirmed in the subgroup of radically treated patients (LEUD: n=0.24 m=0.14 TD50=75.8 Gy). If considering just the grade 3 bleeders (n=9) the best fit is found in correspondence of a n-value around 0.06, suggesting that for severe bleeding the rectum is more serial. CONCLUSIONS: Different NTCP models fit quite accurately the considered clinical data. The results are consistent with a rectum 'less serial' than previously reported investigations when considering grade 2 bleeding while a more serial behaviour was found for severe bleeding. EUD may be considered as a robust and simple parameter correlated with the risk of late rectal bleeding.

Combined Modality Therapy↗

Multi-modal medical image integration to optimize radiotherapy planning in lung cancer treatment.

This work presents a method for CT and PET image registration, and multi-modal analysis, to optimize radiotherapy planning in lung cancer treatment. The method relies on an image registration technique based on fiducial external markers to realign, spatially, PET images with the CT spatial reference system. The method was set up for clinical use in radiotherapy, allowing minimal modifications to be introduced in the management of patients undergoing radiation treatment. The accuracy of the registration technique was evaluated on patient studies in terms of Target Registration Error and was found to be less than 6.40 mm. The method was applied in the treatment planning of five patients affected by non-small-cell lung cancer, revealing the usefulness of PET/CT integration in delineating the extension of both the tumor mass and the tissues involved in the neoplastic process. Moreover, the functional information provided by PET often led to alterations in the treatment planning, changing the size and/or direction of radiation portals. The proposed method for PET/CT integration has been confirmed as being useful for optimizing radiotherapy planning in lung cancer treatment.

Algorithms↗

Effect on local control and survival of electron beam intraoperative irradiation for resectable pancreatic adenocarcinoma.

PURPOSE: To assess the impact on local control and survival of intraoperative radiotherapy (IORT) in resectable pancreatic adenocarcinoma. METHODS AND MATERIALS: The outcome of 127 patients surgically treated with curative intent combined with IORT was compared with the therapeutic results of 76 patients treated with surgery as exclusive treatment. RESULTS: Operative mortality and morbidity were similar in IORT and no-IORT patients. In 49 patients with locally limited disease (Stage I-II; LLD), IORT (n = 30) reduced the local failure rate and significantly prolonged time to local failure (TTLF), time to failure (TTF), and overall survival (OS) with respect to surgery alone (n = 19). The multivariate analyses, stratifying patients by age, tumor grade, resection margins, chemotherapy, and external-beam radiotherapy use, confirmed the independent impact of IORT on outcome. In patients with locally advanced disease (Stage III-IVA; LAD), IORT had an impact on local failure rate and on TTLF when combined with beam energies of greater than 6 MeV, whereas no effect on TTF and OS was observed. CONCLUSION: IORT did not increase operative mortality and morbidity and achieved a significant improvement in local control and outcome in patients with LLD. In patients with LAD, beam energies greater than 6 MeV prolonged TTLF.

Adenocarcinoma↗

Conformal irradiation of concave-shaped PTVs in the treatment of prostate cancer by simple 1D intensity-modulated beams.

BACKGROUND: In the case of concave-shaped PTVs including prostate (P) and seminal vesicles (SV), intensity-modulated radiation therapy (IMRT) should improve the therapeutic ratio of the treatment of prostate cancer. PURPOSE: Comparing IMRT by simple 1D modulations with conventional 3D conformal therapy (i.e. non-IMRT) in the treatment of concave-shaped PTVs including P+SV. MATERIALS AND METHODS: For five patients having a concave-shaped PTV (P+SV) previously treated at our Institute with conformal radiotherapy, conventional 3- and 4-fields conformal plans were compared with IMRT plans in terms of biological indices. IMRT plans were generated by using five equi-spaced beams with a partial shielding of the rectum obtainable with our single-absorber modulation technique (Fiorino C, Lev A, Fusca M, Cattaneo GM, Rudello F, Calandrino R. Dynamic beam modulation by using a single dynamic absorber. Phys. Med. Biol. 1995;40:221-240). The modulation was one-dimensional and the shape of the beams was at single minimum in correspondence with the 'core' of the rectum; the beam intensity in the minimum was set equal to 20 or 40% of the open beam intensity. All plans were simulated on the CADPLAN TPS using a pencil-beam based algorithm (with 18 MV X-rays). Tumour control probability (TCP) and normal tissue complication probabilities (NTCPs) (for rectum, bladder and femoral head) were calculated for all situations when varying the isocentre dose from 60 to 90 Gy. Dose distributions were corrected taking dose fractionation into account through the linear-quadratic model; for the TCP/NTCP estimations the Webb-Nahum and the Lyman-Kutcher models were respectively applied. Three different scores were considered: (a) increase of TCP while keeping rectum NTCP equal to 5% (TCP(5%)); (b) increase of the uncomplicated tumour control probability (P+); (c) increase of the biological-based scoring function (S+), developed by Mohan et al. (Mohan R, Mageras GS, Baldwin B, Clinically relevant optimization of 3D conformal treatments. Med. Phys. 1992;19:933-944). The impact of the uncertainty in the knowledge of the parameters of the biological models was investigated for TCP(5%). RESULTS: (a) The average gain in TCP(5%) when considering IMRT against non-IMRT conformal plans was 7.3% (range 5.0-13.5%); (b) the average increase of P+ was 3.4% (range: 1. 0-8.5%); and (c) the average increase of S+ was 5.4% (range 2.9-12. 4%). The largest gain was found for one patient (patient 5) showing a significantly larger overlapping between PTV and rectum. CONCLUSIONS: Simple 1D-IMRT may clearly improve the therapeutic ratio in the treatment of concave-shaped PTVs including P and SV. In the range of clinically suitable values, the impact of the uncertainty of the parameters n and sigma(alpha) does not significantly alter the main results concerning the gain in TCP(5%). The reported gain in terms of P+ and S+ should be considered with great caution because of the intrinsic uncertainties of the model's parameters and, for bladder, because the 'true' DVH (considering variations of the shape and dimension due to variable filling) may be very different from the DVH calculated on a single CT scan. Further investigations should consider inversely-optimised 1D and 2D-IMRT plan in order to compare them in terms of cost-benefit.

Algorithms↗

Quality assurance by systematic in vivo dosimetry: results on a large cohort of patients.

BACKGROUND: In vivo dosimetry is widely considered to be an important tool for quality assurance in external radiotherapy. INTRODUCTION: In this study we report on our experience over more than 4 years in systematic in vivo dosimetry with diodes. MATERIALS AND METHODS: From November '94 an in vivo entrance dosimetry check was performed for every new patient irradiated at one of our treatment units (Linac 6/100, 6 MV X-rays). Diodes were calibrated in terms of entrance dose; appropriate correction factors had been previously assessed (taking SSDs, field width, wedge, oblique incidence and blocking tray into account) and were individually applied to in vivo diode readings. The in vivo measured entrance dose was compared with the expected one, with a 5% action level; if a larger deviation was found, all treatment parameters were verified, and the in vivo dosimetry check was repeated. During the period November '94-May '99, 2824 measurements on 1433 patients were collected. RESULTS: Nine out of 1433 (0.63%) serious systematic errors (leading to a 5% or more on the delivered dose to the PTV) were detected by in vivo dosimetry; four out of nine would produce a 10% or more error if not detected. The rate of serious systematic errors detected by an independent check of treatment chart and MU calculation was found to be 1.5%, showing that less than 1/3 of the errors escapes this check. One hundred and twelve out of 1433 (7.8%) patients had more than one check: the rate of second checks was significantly higher for breast patients (31/250, 12.4%) against non-breast patients (81/1183, 6.8%, P=0.003). A number of patients demonstrated a persistent relatively large error even after two or more checks. For almost all patients the cause of the deviation was assessed; the most frequent cause was the difficulty in correctly positioning the patient and/or the diode. When analyzing the distribution of the deviations between measured and expected entrance doses (excluding first checks in the case of repetition of the in vivo dosimetry control) the mean deviation was 0.4% with a standard deviation equal to 3.0%. The rates of deviations larger than 5 and 7% were 9.9 and 2.6%, respectively. When considering the same data taking the average deviation in the case of opposed beams, the SD became 2.6% and the rates of deviations larger than 5 and 7%, respectively, 5.2 and 0.8%. When dividing the beams according to their orientation, significantly higher rates of large deviations (>5 and 7%) were found for oblique and posterior-anterior (PA) fields against lateral and anterior-posterior (AP) fields (P<0.05). Similarly, higher rates of large deviations were found for wedged fields against unwedged fields (P<0.03) and for blocked fields against unblocked fields (P<0.01). When dividing the data according to the anatomical district, accuracy was worse for breast (mean deviation 0.1%, 1 SD: 3.5%) and neck AP-PA fields (mean deviation 1%, 1 SD: 3,4%). Better accuracy was found for vertebrae (0.1%, 1 SD 2. 1%) and brain patients (-0.7%, 1 SD: 2.6%). During the considered period, in vivo dosimetry was also able to promptly detect a systematic error caused by a wrong resetting of the simulator height couch indicator, with a consequent error in the estimate of patient thickness of about 4 cm. CONCLUSIONS: In our experience, systematic in vivo dosimetry demonstrated to be a valid tool for quality assurance, both in detecting systematic errors which may escape the data transfer/MU calculation check and in giving an effective way of estimating the accuracy of treatment delivery.

Cohort Studies↗

Polarity effects of ionization chambers used in tbi dosimetry due to cable irradiation.

This paper presents the results of an investigation on polarity effects in total-body irradiation (TBI) dosimetry. Thimble (NE2571, 0.6 cc) and plane-parallel (Markus NE2534 0.055 cc) chambers were investigated in a 30 x 30 x 30-cm3 acrylic phantom in TBI conditions (6-MV x-rays). The thimble chamber was positioned at the midline and at the entrance and exit Dmax (1.5 cm from the phantom surface) levels. The Markus chamber, which is generally used for skin dose estimations, was positioned at various depths from the entrance surface of the phantom (from 0- to 2-cm depth). The polarity factor (Ppol) was defined as (Q+ + Q-)/2Q-, where Q+ and Q- were the collected charges at positive and negative bias voltage, respectively. The variations of Ppol with many parameters (absorbed dose, dose rate, the presence or absence of a 1-cm acrylic spoiler, irradiated cable length) were investigated. Results show that Ppol is quite small (within 1.002 for on-axis measurements and 1.005 for off-axis measurements) for the NE2571 chamber when the beam spoiler is placed. Ppol was significantly higher without the beam spoiler (within 1.008 for on-axis measurements, up to 1.02 for off-axis measurements). Concerning the Markus chamber, for on-axis skin dose measurements, Ppol was found to be less than unity (around 0.988) or more than unity (around 1.0035), respectively, with and without the beam spoiler. Possible "directional effects" of the currents generated in the cable were investigated for both chambers and found to be insignificant. This shows that the application of Ppol correction has to be considered a reliable procedure in minimizing these effects. When the beam spoiler is placed, the cable has to be drawn to minimize the portion of cable just outside the beam; if this is not the case, Ppol may significantly vary (for the NE2571 chamber values up to 1.0035 were found for on-axis measurements).

Humans↗

Dosimetric evaluation of a commercial 3-D treatment planning system using Report 55 by AAPM Task Group 23.

BACKGROUND AND PURPOSE: A relevant part of radiotherapy treatment planning system QA concerns dose calculation verification. Report 55 by AAPM TG-23 is an instrument for performing dosimetric evaluation of treatment planning systems in case of external photon beams. It was employed by different groups in three radiotherapy departments for controlling performances of RTPS CadPlan Varian-Dosetek, versions 2.7.9, 3.0.6 and 3.1.1. MATERIALS AND METHODS: Once the basic data of the AAPM 4 MV and 18 MV X-ray units had been converted into the CadPlan format and the AAPM units configured, the whole set of TG23 tests were carried out on three different systems. According to Report 55, comparisons between values measured by TG-23 and calculated by RTPS were made in terms of dose at selected points and radiological field width at different depths. RESULTS: As far as dose is concerned, 266 data were compared for 4 MV and 297 for 18 MV. Ninety-five-point-nine percent of dose deviations for 4 MV and 92.6% for 18 MV are less than 2%. Most of the relevant discrepancies for both energies occur in a test case where dose has to be calculated under a long narrow block centred on the beam axis. Deviations as much as 6.1% for 4 MV and -7.5% for 18 MV were observed in points at 1 cm depth under the block. Poor results were also observed in the rectangular field 25 x 5, in points outside the field edges under collimators. As regards radiological field width, 58 out of 64 comparisons for 4 MV occurred in the range +/- 2 mm. For 18 MV the biggest deviation was -2.2 mm. CONCLUSIONS: The TG-23 tests demonstrated that the accuracy of the RTPS in dose calculation is good in most of the typical radiotherapy applications. Our results are better than those recently published for other RTPS. The TG-23 package turned out to be an effective instrument for QA and calculation verification, as well as being a powerful method for training purpose in configuring and using a RTPS.

Radiometry↗

In-vivo dosimetry by diode semiconductors in combination with portal films during TBI: reporting a 5-year clinical experience.

BACKGROUND AND PURPOSE: In-vivo dosimetry is vital to assure an accurate delivery of total body irradiation (TBI). In-vivo lung dosimetry is strongly recommended because of the risk of radiation-induced interstitial pneumonia (IP). Here we report on our 5-year experience with in-vivo dosimetry using diodes in combination with portal films and assessing the effectiveness of in-vivo dosimetry in improving the accuracy of the treatment. Moreover, we wished to investigate in detail the possibility of in-vivo portal dosimetry to yield individual information on the lung dose and to evaluate the impact of CT planning on the correspondence between stated and in-vivo measured doses. MATERIALS AND METHODS: From March 1994 to March 1999, 229 supine-positioned patients were treated at our Institute with TBI, using a 6 MV X-rays opposed lateral beam technique. 146 patients received 10 Gy given in three fractions, once a day (FTBI), shielding the lungs by the arms; 70 received 12-13.2 Gy, given in 6-11 fractions, 2-3 fractions per day (HFTBI): in this case about 2/3 of the lungs were shielded by moulded blocks (mean shielded lung dose equal to 9 or 9.5 Gy). Thirteen patients received 8 Gy given in a single fraction (SFTBI, lung dose: 7 Gy). For all HFTBI and FTBI patients, midline in-vivo dosimetry was performed at the first fraction by positioning two diodes pairs (one at entrance and one at the exit side) at the waist (umbilicus) and at the pelvis (ankles). If at least one of the two diodes doses (waist-pelvis) was outside +/-5% from the prescribed dose, actions could be initiated, together with possible checks on the following fractions. Transit dosimetry by portal films was performed for most patients; for 165 of them (117 and 48, respectively for FTBI and HFTBI) the midline in-vivo dose distribution of the chest region was derived and mean lung dose assessed. As a CT plan was performed for all HFTBI patients, for these patients, the lung dose measured by portal in-vivo dosimetry was compared with the expected value. RESULTS: Concerning all diodes data, 528 measurements were available: when excluding the data of the first fraction(s) of the patients undergoing corrections (n = 392), mean and SD were respectively 0.0% and 4.5% (FTBI: -0.3 +/- 4.8%; HFTBI: 0.4 +/- 3.9%). In total 105/229 patients had a change after the first fraction and 66/229 were controlled by in-vivo dosimetry for more than one fraction. Since January 1998 a CT plan is performed for FTBI patients too: when comparing the diodes data before and after this date, a significant improvement was found (i.e. rate of deviations larger than 5% respectively equal to 30.7% and 13.1%, P = 0.007). When considering only the patients with a CT plan, the global SD reduced to 3.5%. Concerning transit dosimetry data, for FTBI, the mean (midline) lung dose was found to vary significantly from patient to patient (Average 9.13 +/- 0.81 Gy; range 7.4-11.4 Gy); for the HFTBI patients the mean deviation between measured and expected lung dose was 0.0% (1 SD = 3.8%). CONCLUSIONS: In vivo dosimetry is an effective tool to improve the accuracy of TBI. The impact of CT planning for FTBI significantly improved the accuracy of the treatment delivery. Transit dosimetry data revealed a significant inter-patient variation of the mean lung dose among patients undergoing the same irradiation technique. For patients with partial lung shielding (HFTBI), an excellent agreement between measured and expected lung dose was verified.

Ankle↗

Dosimetry of Gamma Knife and linac-based radiosurgery using radiochromic and diode detectors.

In stereotactic radiosurgery the choice of appropriate detectors, whether for absolute or relative dosimetry, is very important due to the steep dose gradient and the incomplete lateral electronic equilibrium. For both linac-based and Leksell Gamma Knife radiosurgery units, we tested the use of calibrated radiochromic film to measure absolute doses and relative dose distributions. In addition a small diode was used to estimate the relative output factors. The data obtained using radiochromic and diode detectors were compared with measurements performed with other conventional methods of dosimetry, with calculated values by treatment planning systems and with data prestored in the treatment planning system supplied by the Leksell Gamma Knife (LGK) vendor. Two stereotactic radiosurgery techniques were considered: Leksell Gamma Knife (using gamma-rays from 60Co) and linac-based radiosurgery (LR) (6 MV x-rays). Different detectors were used for both relative and absolute dosimetry: relative output factors (OFs) were estimated by using radiochromic and radiographic films and a small diode; relative dose distributions in the axial and coronal planes of a spherical polystyrene phantom were measured using radiochromic film and calculated by two different treatment planning systems (TPSs). The absolute dose at the sphere centre was measured by radiochromic film and a small ionization chamber. An accurate selection of radiochromic film was made: samples of unexposed film showing a percentage standard deviation of less than 3% were used for relative dose profiles, and for absolute dose and OF evaluations this value was reduced to 1.5%. Moreover a proper calibration curve was made for each set of measurements. With regard to absolute doses, the results obtained with the ionization chamber are in good correlation with radiochromic film-generated data, for both LGK and LR, showing a dose difference of less than 1%. The output factor evaluations, performed using different methods, are in good agreement with a maximum difference of 1.5% for all field sizes considered (LGK and LR) except the 4 mm helmet used in the LGK unit. In this case, differences exist between diode and radiochromic film measurements and both detectors show data values larger than the prestored OF value of 0.80. Dose profiles measured by radiochromic film and calculated are in excellent agreement for both LGK and LR with a maximum deviation of less than 1.0 mm, when full widths of the dose profiles at 20%, 50%, 80% levels are considered. When external photon beams are used in stereotactic radiosurgery, the 'well selected' radiochromic films are very accurate detectors both for relative and absolute dosimetry. The experimental results, obtained using both radiochromic and diode detectors, show that the 4 mm helmet relative output factor could be underestimated.

Film Dosimetry↗

Use of dose-volume histograms and biophysical models to compare 2D and 3D irradiation techniques for non-small cell lung cancer.

For non-small cell lung cancer (NSCLC), unsatisfactory local control (LC) still remains an important cause of failure. It has been suggested that improved LC can be achieved with both higher radiation dosage and adequate target coverage. Modern three-dimensional treatment planning systems (3D-TPSs) offer many tools for planning optimization. Biophysical models, which estimate the normal tissue complication probability (NTCP), are gaining in importance in comparing plans. This study compares conventional two-dimensional (2D) with 3D irradiation techniques using parameters related to volumetric dose distribution and two different biophysical models predicting normal tissue tolerance to radiotherapy (RT). Nine patients with inoperable locally advanced NSCLC were treated with a beam's eye view-based 3D technique. For the same patients, a conventional treatment was simulated; the irradiation geometry and beam contour were fully defined at the simulator and then transferred to the 3D-TPS to calculate the dose distribution. Both techniques gave the same prescribed dose at the reference point. Dose-volume histograms (DVHs) and dose statistics of organs at risk (OARs) (heart, lung(s), parenchyma lung, spinal cord and oesophagus) were analysed. The probability of side effects was estimated using two different biophysical models: the integrated normal ("empirical") model and the relative seriality model. Apart from contralateral lung, the 3D irradiation technique significantly reduced the average mean doses to all OARs. The current analysis suggests that in the treatment of locally advanced NSCLC, the use of 3D irradiation techniques allows a large sparing of OARs; this advantage is confirmed by both dose statistics analysis and NTCP values.

Aged↗

[Integration of computerized tomography imaging with single photon emission in a commercial system for developing radiotherapy fields: application to conformational irradiation for lung carcinoma].

PURPOSE: Single photon emission computed tomography (SPECT) of lung perfusion permits to map functioning lung parenchyma with higher sensitivity than CT. Delivering higher radiation doses is used to increase local control in lung carcinoma; this strategy is based on radiobiological and clinical studies. Lung parenchyma is a dose-limiting tissue in patients irradiated for lung cancer. Functional mapping based on SPECT and CT findings permits to design radiation beams such as to minimize irradiation of functioning lung. MATERIAL AND METHODS: CT and SPECT were used to examine a patient with non small cell lung carcinoma (stage IIIB, T4N0, left lung) candidate to conformal irradiation. Images were spatially correlated based on lung contours and using CT findings as reference. SPECT images were normalized to mean right lung value and expressed as perfusion (functional) contours. CT images and perfusion contours were transferred to the treatment planning system (Cadplan V 2.79, Varian-Dosetek Oy): in this way both functional (SPECT) and anatomical (CT) data were available for planning. A comparison was made between two irradiation techniques defined at TPS with (technique B) or without (technique A) SPECT contour information. The prescribed dose was 70.2 Gy. Rival plans were compared using dose volume histograms of target and risk organs. Both functional and anatomical regions were considered in the lung, together with single lung(s) and lung parenchyma. A second perfusion SPECT was obtained 5 months after irradiation and correlated with pretreatment CT images. RESULTS: SPECT lung scans showed marked heterogeneity in the left lung, which was found neither at CT nor at classic lung function tests. The lung volume with perfusion exceeding 80% of average corresponds to about 70% of the anatomical volume. Mean doses to anatomical and to functional lung parenchyma were 24 Gy and 19 Gy, respectively, with technique A and 23 Gy and 18 Gy, respectively, with technique B. Thirty-five percent and 20%, respectively of anatomical and functional lung parenchyma received > or = 25 Gy (V25) with technique B. The figure for functional lung parenchyma was reduced by 5% with technique B. Optimal design of irradiation field geometry decreased the area of functional parenchyma given high doses, which sparing was greater with smaller irradiation volumes. CONCLUSIONS: We have integrated the functional data provided by SPECT lung perfusion into a commercial irradiation planning system. Lung function mapping permits to design irradiation portals sparing larger areas of functional lung parenchyma.

Carcinoma, Non-Small-Cell Lung↗

Dose calculation and dosimetry tests for clinical implementation of 1D tissue-deficit compensation by a single dynamic absorber.

BACKGROUND AND PURPOSE: In this study the possibilities for implementing 1D tissue-deficit compensation techniques by a dynamic single absorber were investigated. This research firstly involved a preliminary examination on the accuracy of a pencil beam-based algorithm, implemented for irregularly shaped photon beams in our 3D treatment planning system (TPS) (Cadplan 2.7, Varian-Dosetek Oy), in calculating dose distributions delivered in ID non-uniform fields. Once the reliability of the pencil beam (PB) algorithm for dose calculations in non-uniform beams was verified, we proceeded to test the feasibility of tissue-deficit compensation using our single absorber modulator. As an example, we considered a mantle field technique. MATERIALS AND METHODS: To evaluate the accuracy of the method employed in calculating dose distributions delivered in 1D non-uniform fields, three different fluence profiles, which could be considered as a small sample representative of clinically relevant applications, were selected. The incident non-uniform fluences were simulated by the sum of simple blocked fields (i.e. with rectangular 'strip' blocks, one per beam) properly weighed by the 'modulation factors' Fi, defined in each interval of the subdivided profile as the ratio between the desired fluence and the open field fluence. Depth dose distributions in a cubic phantom were then calculated by the TPS and compared with the corresponding doses (at 5 and 10 cm acrylic depths) delivered by the single absorber modulation system. In the present application, the absorber speed profile able to compensate for the tissue deficit along the cranio-caudal direction and then homogenizing the dose distribution on a 'midline' isocentric plane with sufficient accuracy can be directly derived from anatomic data, such as the SSDs (source-skin distances) along the patient contour. The compensation can be verified through portal dosimetry techniques (using a traditional port film system). RESULTS: The technique was tested in isocentric conditions on the humanoid RANDO phantom in a clinically suitable situation. The agreement between expected/calculated and measured incident/exit dose profiles was found to be within 4%, with deviations generally around 1-2%. As for the PB accuracy investigation for dose calculations in non-uniform fields, calculated versus measured dose profiles were found to be in good agreement, indicating a satisfactory accuracy of the method employed for dose calculation in 1D non-uniform photon beams. A better performance should be expected if the incident fluences could be directly inserted in the TPS. CONCLUSIONS: The results show that the proposed technique should be sufficiently reliable for clinical application. The main advantages are its simplicity and the possibility of application on Linacs which have no complex options for dynamic control of collimators.

Algorithms↗

Intra- and inter-observer variability in contouring prostate and seminal vesicles: implications for conformal treatment planning.

BACKGROUND AND PURPOSE: Accurate contouring of the clinical target volume (CTV) is a fundamental prerequisite for successful conformal radiotherapy of prostate cancer. The purpose of this study was to investigate intra- and inter-observer variability in contouring prostate (P) and seminal vesicles (SV) and its impact on conformal treatment planning in our working conditions. MATERIALS AND METHODS: Inter-observer variability was investigated by asking five well-trained radiotherapists of contouring on CT images the P and the SV of six supine-positioned patients previously treated with conformal techniques. Short-term intra-observer variability was assessed by asking the radiotherapists to contour the P and SV of one patient for a second time, just after the first contouring. The differences among the inserted volumes were considered for both intra- and inter-observer variability. Regarding intra-observer variability, the differences between the two inserted contours were estimated by taking the relative differences in correspondence to the CT slices on BEV plots (antero-posterior and left-right beams). Concerning inter-observer variability, the distances between the internal and external envelopes of the inserted contours (named projected diagnostic uncertainties or PDUs) and the distances from the mean inserted contours (named mean contour distances or MCDs) were measured from BEV plots (i.e. parallel to the CT slices). RESULTS: Intra-observer variability was relatively small (the average percentage variation of the volume was approximately 5%; SD of the differences measured on BEV plots within 1.8 mm). Concerning inter-observer variability, the percentage SD of the inserted volumes ranged from 10 to 18%. Differences equal to 1 cm in the cranio-caudal extension of P + SV were found in four out of six patients. The largest inter-observer variability was found when considering the anterior margin in the left-right beam of P top (MCD = 7.1 mm, 1 SD). Relatively high values for MCDs were also found for P bottom, for the posterior and lateral margins of P top (2.6 and 3.1 mm, respectively, I SD) and for the anterior margin of SV (2.8 mm, 1 SD). Relatively small values were found for P central (from 1.4 to 2.0 mm, 1 SD) and the posterior margin of SV (1.5 mm, 1 SD). CONCLUSIONS: The application of larger margins taking inter-observer variability into account should be taken into consideration for the anterior and the lateral margins of SV and P top and for the lateral margin of P. The impact of short-term intra-observer variability does not seem to be relevant.

Humans↗

Set-up error in supine-positioned patients immobilized with two different modalities during conformal radiotherapy of prostate cancer.

BACKGROUND: Conformal radiotherapy requires reduced margins around the clinical target volume (CTV) with respect to traditional radiotherapy techniques. Therefore, high set-up accuracy and reproducibility are mandatory. PURPOSE: To investigate the effectiveness of two different immobilization techniques during conformal radiotherapy of prostate cancer with small fields. MATERIALS AND METHODS: 52 patients with prostate cancer were treated by conformal three- or four-field techniques with radical or adjuvant intent between November 1996 and March 1998. In total, 539 portal images were collected on a weekly basis for at least the first 4 weeks of the treatment on lateral and anterior 18 MV X-ray fields. The average number of sessions monitored per patient was 5.7 (range 4-10). All patients were immobilized with an alpha-cradle system; 25 of them were immobilized at the pelvis level (group A) and the remaining 27 patients were immobilized in the legs (group B). The shifts with respect to the simulation condition were assessed by measuring the distances between the same bony landmarks and the field edges. The global distributions of cranio-caudal (CC), posterior-anterior (PA) and left-right (LR) shifts were considered; for each patient random and systematic error components were assessed by following the procedure suggested by Bijhold et al. (Bijhold J, Lebesque JV, Hart AAM, Vijlbrief RE. Maximising set-up accuracy using portal images as applied to a conformal boost technique for prostatic cancer. Radiother. Oncol. 1992;24:261-271). For each patient the average isocentre (3D) shift was assessed as the quadratic sum of the average shifts in the three directions. RESULTS: Group B showed a better accuracy and reproducibility than group A for PA shifts (2.6 versus 4.4 mm, 1 SD), LR shifts (2.4 versus 3.6 mm, 1 SD) and CC shifts (2.7 versus 3.3 mm, 1 SD). Furthermore, group B showed a rate of large PA shifts (>5 mm) equal to 4.4% with respect to the 21.6% of group A (P<0.0001). This value was also better than the corresponding value found in a previously investigated group of 21 non-immobilized patients (Italia C, Fiorino C, Ciocca M, et al. Quality control by portal film analysis of the conformal radiotherapy of prostate cancer: comparison between two different institutions and treatment techniques (abstract). Radiother. Oncol. 1997;43(Suppl. 2):S16, 16.8%, P = 0.001). For both groups there was no clear prevalence of one component (systematic or random) with respect to the other. The average isocentre shifts (averaged on all patients) were 3.0 mm (+/-1.4 mm, 1 SD) for group B and 5.0 mm (+/-2.8 mm, 1 SD) for group A against a value of 4.4 mm (+/-2.4 mm, 1 SD) for the previously investigated non-immobilized patient group. CONCLUSIONS: Immobilization of the legs with an alpha-cradle system seems to improve both the accuracy and reproducibility of the positioning of patients treated for prostate cancer with respect to alpha-cradle pelvic-abdomen immobilization. Based on these data, we decided to use the legs immobilization system and to reduce the margin around the CTV (from 10 to 8 mm) in the PA direction.

Humans↗

Comparing 3-, 4- and 6-fields techniques for conformal irradiation of prostate and seminal vesicles using dose-volume histograms.

BACKGROUND AND PURPOSE: Comparing some isocentric coplanar techniques for conformal irradiation of prostate and seminal vesicles. MATERIALS AND METHODS: Five conformal techniques have been considered: (A) a 3-fields technique with an antero-posterior (AP) field and two lateral (LAT-LAT) 30 degrees wedged fields; (B) a 3-fields technique with an AP field and two oblique posterior (OBL) 15 degrees wedged fields with relative weights of 0.8, 1 and 1, respectively; (C) a 4-fields technique (AP-PA and LAT-LAT); (D) a 6-fields technique (LAT-LAT and four OBL at gantry angles 45 degrees, 135 degrees, 235 degrees and 315 degrees) with all the fields having the same weight; (E) the same 6-fields technique with lateral fields double-weighted with respect to the oblique fields. The conformal plans have been simulated on 12 consecutive patients (stages B and C) by using our 3D treatment planning system (Cadplan 2.7). The contours of the rectum, the bladder and the left femoral head were outlined together with the clinical target volume (CTV) which included the prostate and the seminal vesicles. A margin of 10 mm was added to define the planning target volume (PTV) through automatic volume expansion. Then a 7 mm margin between the PTV and block edges was added to take the beam penumbra into account. Dose distributions were normalised to the isocentre and the reference dose was considered to be 95% of the isocentre dose. Dose-volume histograms and dose statistics of the rectum, the bladder and the left femoral head were collected for all plans. For the rectum and the bladder the mean dose (Dm) and the fraction of volume receiving a dose higher than the reference dose (V95) were compared. For the femoral head, the mean dose together with the fraction of volume receiving a dose higher than 50% (V50) were compared. RESULTS: Differences among the techniques have been found for all three considered organs at risk. When considering the rectum, technique A is better than the others both when considering Dm and V95 (P = 0.002), while technique D is the worst when considering Dm (P < 0.002) and is also worse than techniques A, E (P = 0.002) and C (P = 0.003) when considering V95. Technique E is the best when considering the bladder mean dose (P = 0.002 against A and D, P < 0.01 against B and C) and technique C is the worst (P < 0.012). No relevant differences were found for the bladder V95. In the femoral heads, techniques A and E are worse than B, C and D (P < 0.003) when considering Dm and V50. Moreover, techniques B and D are better than C (P < 0.004) when considering V50. CONCLUSIONS: There is no technique that is absolutely better than the others. Technique A gives the best sparing of the rectum; the bladder is better spared with technique E. These results are reached with a worse sparing of the femoral heads which should be carefully taken into account.

Femur Head↗

Detection of systematic errors in external radiotherapy before treatment delivery.

The execution of an independent control of monitor units (MU) and dose distribution calculation, together with a check of the data reported in the treatment chart is an effective tool in strongly reducing the occurrence of systematic errors before treatment delivery. In this paper we report the results of the analysis of 6272 controls (about 5000 patients) registered over more than 5 years; 70 serious errors (producing a deviation larger than 5% from the prescribed daily dose) and 147 minor errors were detected and corrected before the start of the treatment. The error rate was found to be strongly operator-dependent (serious error rate ranging from 0.3 to 2.5% when considering different operators). A time-trend analysis showed a significant reduction of serious errors, i.e. 1.5% in the period from September 1991 to April 1994 compared to 0.9% in the period from April 1994 to November 1996. However, even if the double check was highly effective in revealing human errors, three serious systematic errors (errors occurring during the calculation/planning/transcription phases) escaped the control and were detected by diode in vivo dosimetry during the period October 1994 to November 1996 (in 650 patients controlled).

Humans↗

Variations of tumor control and rectum complication probabilities due to random set-up errors during conformal radiation therapy of prostate cancer.

BACKGROUND AND PURPOSE: The effect of random set-up errors on tumor control probability (TCP) and rectum complication probability (NTCP) on 3D conformal treatment planning of prostate cancer has been investigated by applying the convolution method originally proposed by Leong (Leong, J. Implementation of random positioning error in computerized radiation treatment planning systems as a result of fractionation. Phys. Med. Biol. 32: 327-334, 1987). MATERIALS AND METHODS: The combined influence of the standard deviation of the random shifts probability distribution (sigma) of the dose and of the Beam's-eye-view margin (M) between the clinical target volume (CTV) and the edge of the blocks have been investigated in two patients. RESULTS AND CONCLUSIONS: Random set-up error has been found to decrease TCP (for a typical 70 Gy CTV mean dose) by up to 6% for a 1 cm margin (sigma = 7 mm). When M is equal to or larger than 1.5 cm, no relevant effects on TCP are obtained. Maximum acceptable TCP values (corresponding to a rectum NTCP equal to 5%) have been derived and the dependence on sigma and M has been investigated.

Humans↗