PubMed Health⌕ Search

Biomedical subjects

G M O'Connor

Publications and source records attributed to G M O'Connor.

9 recordsLinked to original sources

Characterisation of an antibody coated microcantilever as a potential immuno-based biosensor.

In this study, we investigated the activity, stability, lifetime and re-usability of monoclonal antibodies to myoglobin covalently immobilised onto microfabricated cantilever surfaces. These sensing surfaces are of interest to us in the development of novel cantilever-based immunosensors. For such sensors the antibody layer represents the sensing element while the microcantilever acts as a mechanical transducer. A procedure for producing re-usable biological coatings has been tested with different independent techniques. An Enzyme Linked Immunosorbent Assay (ELISA) was used to determine the presence of an active antibody coating, and to monitor the lifetime and stability of the immobilised antibody. Through this analysis, the activity of the immobilised antibody layer was found to be more stable with the introduction of sucrose, as a stabilising agent. Sucrose was applied to the immobilised antibody layer after each regeneration step. The immobilised antibody was found to have a stable active lifetime for up to 7 weeks. Fluorescence microscopy was used to give information on the distribution of the coating on the gold and silicon nitride sides of the cantilever. Atomic Force Microscopy was used to determine the presence of the biological coating on the cantilever and to obtain information on the surface morphology of the biological element of the sensor. The combined results provide valuable information on the development of an optimised sensing element and demonstrate a set of methods to use for future sensor-to-sensor characterisation. Preliminary experimental results showing the antibody activity against myoglobin, detected with a microcantilever based sensor prototype confirmed the motivations and potentialities of the proposed immunosensing technique.

Biosensing Techniques↗

External ocular trauma in instrumental and normal deliveries.

OBJECTIVE: To compare the occurrence of external ocular trauma in instrumental and normal deliveries. DESIGN: Prospective controlled study. SETTING: University Hospital of Wales, Cardiff. SUBJECTS: 133 babies born consecutively with the use of forceps and 133 control babies born without instrumentation to women matched for parity. INTERVENTIONS: External ocular examination. MAIN OUTCOME MEASURES: The presence within 24 h of birth of corneal oedema, corneal abrasion, conjunctival chemosis, subconjunctival haemorrhage and lid oedema. RESULTS: Lid oedema and multiple minor external ocular trauma occurred in 52 and 22 babies, respectively, in the instrumental delivery group and in 13 and 8 babies, respectively in the control group (P less than 0.001). Corneal abrasion occurred in two babies and corneal oedema in one baby after forceps delivery but in none of the control group. No more serious injuries occurred. All injuries resolved without long term sequelae. CONCLUSION: The frequency of sight threatening corneal trauma in instrumental deliveries is low. Specialist ophthalmic screening of these babies is not justified.

Birth Injuries↗

Dynamic retinoscopy.

Dynamic retinoscopy for the objective examination of accommodation was described in the ophthalmic literature in the 1890s but is rarely used in ophthalmology today. The technique has been extensively investigated by the optometric profession, however, sometimes with confusing, and sometimes with useful, results. It can be of value in screening infants for astigmatism and anisometropia, in detecting incomplete cycloplegia, in detecting abnormalities of accommodation, and probably in determining the treatment strategy for eyes with amblyopia and deficient accommodation.

Accommodation, Ocular↗

Ocular cowpox: transmission from the domestic cat to man.

A clinicopathological case of ocular cowpox is reported. Cowpox is no longer regarded as being enzootic in cattle. The most likely mode of transmission of cowpox to man appears to be from the domestic cat or wild rodents.

Adolescent↗

A new synthetic material for the brow suspension procedure.

This report describes the use of a new synthetic material, combining polyester with carbon, in nine brow suspension procedures. The mechanical properties of polyester, with the fibrous tissue inducing properties of carbon, combine to produce a scaffolding on which fibrovascular ingrowth is possible. Subsequent fibrosis gives a permanent effect. Early results indicate that the material is tolerated well in the eyelid, but the problem of early slippage remains.

Blepharoptosis↗

Transposition surgery in childhood strabismus.

Transposition surgery involves an alteration in the mechanical properties of muscle action, such that the direction of movement of the eye following contraction of the muscle is modified. Though often used in the management of more complex motility disorders we have investigated the role of such surgery in concomitant childhood strabismus, and report the results of a computer model prediction and a retrospective review of cases.

Adolescent↗