In vitro evaluation of the effect of aortic compliance on pediatric intra-aortic balloon pumping.

OBJECTIVES: To evaluate the effect of aortic compliance on pediatric intra-aortic balloon pumping (IABP). DESIGN: In vitro study using a mechanical model of the pediatric left heart circulation. SETTING: Cardiovascular fluid dynamics research laboratory. SUBJECT: Pulsatile flow system simulating the pediatric left heart circulation and two different aortas with compliances comparable to those of the pediatric aorta (0.12 and 0.07 mL/mm Hg). INTERVENTIONS: Measurements were made at a baseline peak aortic flow of 4 L/min, at simulated shock (1.7 L/min), and with 1:1 IABP (rates, 130 and 150 bpm; balloon volumes, 2.5 and 5.0 mL). MEASUREMENTS AND MAIN RESULTS: Peak flow rates were measured in the ascending aorta, coronary arterial system, and brachiocephalic arterial systems. Aortic pressure was measured in the ascending aorta. For both aortas (0.12 and 0.07 mL/mm Hg), IABP resulted in diastolic augmentation (38 +/- 8 and 43 +/- 16 mm Hg) and afterload reduction (4 +/- 2 and 6 +/- 3 mm Hg). For both aortas, compared to shock, IABP resulted in significant increases in coronary arterial and brachiocephalic arterial flow and aortic pressure for both aortas. Aortic flow significantly increased only in the less-compliant aorta. CONCLUSIONS: In a laboratory model of pediatric left heart circulation, IABP results in diastolic augmentation, afterload reduction, and improved hemodynamics, even in aortas of greater compliance.

Journal Article↗

Aortic input impedance in infants and children.

Flow and pressure measurements were performed in the ascending aortas of six pediatric patients ranging in age from 1 to 4 yr and in weight from 7.2 to 16.4 kg. From these measurements, input impedance was calculated. It was found that total vascular resistance decreased with increasing patient weight and was approximately one to three times higher than those of adults. Conductance per unit weight was relatively constant but was approximately three times higher than for adults. Strong inertial character was observed in the impedance of four of the six patients. Among a three-element and two four-element lumped-parameter models, the model with characteristic aortic resistor (R(c)) and inertance in series followed by parallel peripheral resistor (R(p)) and compliance fitted the data best. R(p) decreased with increasing patient weight and was one to three times higher than in adults, and R(c) decreased with increasing patient weight and was 2 to 15 times higher. The R(p)-to-R(c) ratio differed significantly between infants and children vs. adults. The results suggested that R(p) developed more rapidly with patient weight than did R(c). Compliance values increased with increasing patient weight and were 3 to 16 times lower than adult values.

Aorta↗

Neonatal piglet model of intraaortic balloon pumping: improved efficacy using echocardiographic timing.

BACKGROUND: Pediatric intraaortic balloon pumping (IABP) has met with little success because of technical difficulty in tracking rapid heart rates. This study was designed to evaluate the efficacy of M-mode echocardiography for IABP timing in a neonatal piglet model. METHODS: Two groups of piglets underwent mitral valve avulsion to create a model of shock. Group 1 (n = 8; mean weight, 7.7+/-1.8 kg) underwent IABP timed with both the ascending aortic pressure and M-mode echocardiogram. Group 2 (n = 6; mean weight, 7.5+/-1.4 kg) underwent two separate periods of IABP: one with echocardiographic timing and the second using standard timing points from the femoral arterial pressure tracing and electrocardiogram. Measurements included ascending aortic flow, left anterior descending arterial flow, ascending aortic pressure, left atrial pressure, and heart rate. RESULTS: Mitral valve avulsion produced a shock model with a significant decrease in mean aortic pressure and aortic flow and a significant increase in left atrial pressure and heart rate. Compared with the shock state, IABP in group 1 animals resulted in a significant increase in aortic flow (353+/-152 versus 454+/-109 mL/min; p < 0.05) and a significant decrease in left atrial pressure (23+/-6 versus 17+/-7 mm Hg; p < 0.05). Group 2 animals with echocardiogram-timed IABP had significantly increased aortic flow (365+/-106 versus 458+/-107 mL/min; p < 0.05) and mean aortic pressure (43+/-11 versus 52+/-8 mm Hg; p < 0.05). However, standard-timed IABP failed to show any improvement. CONCLUSIONS: In piglets with rapid heart rates, echocardiogram-timed IABP results in increased aortic flow and pressure and decreased left atrial pressure compared with standard-timed IABP.

Animals↗

Long-term mechanical circulatory support system reliability recommendation: American Society for Artificial Internal Organs and The Society of Thoracic Surgeons: long-term mechanical circulatory support system reliability recommendation.

Jointly developed by members of the American Society for Artificial Internal Organs and the Society of Thoracic Surgeons along with staff from the Food and Drug Administration, the National Heart, Lung and Blood Institute and other experts, this recommendation describes the reliability considerations and goals for Investigational Device Exemption and Premarket Approval submissions for long-term, mechanical circulatory support systems. The recommendation includes a definition of system failure, a discussion of an appropriate reliability model, a suggested in vitro reliability test plan, reliability considerations for animal implantation tests, in vitro and animal in vivo performance goals, the qualification of design changes during the Investigational Device Exemption clinical trial, the development of a Failure Modes Effects and Criticality Analysis, and the reliability information for surgeons and patient candidates. The document will be periodically reviewed to assess its timeliness and appropriateness within five years.

Animals↗

Variation in artificial heart acceleration and sound production with prosthetic valve selection in vitro.

In an attempt to explore methods to reduce total artificial heart (TAH) acceleration and sound production, in vitro measurements of TAH acceleration and sound were made when using a variety of prosthetic valves in a test ventricle. A miniature, uniaxial, high fidelity accelerometer was glued to the housing of a UTAH-100 left ventricle adjacent to the inflow and outflow ports and parallel to the axis of diaphragm excursion. A miniature, high fidelity contact microphone was glued to the opposite side of the ventricular housing between the inflow and outflow ports. Data was collected over a range of heart rates, ventricular filling volumes and control modes while using tilting disc valves (TDV) and polymer trileaflet valves (PTV). For both valve types, the peak systolic acceleration impulse was lower (approximately equal to 50%) when the ventricle was fully rather than partially filled and the peak diastolic acceleration impulse was lower (approximately equal to 50%) when the ventricle was fully rather than partially ejected. The magnitude of the acceleration with PTVs was approximately equal to 20x less than the TDVs (0.5 to 2.2 g vs. 10 to 49g). The magnitude of the sound production was also considerably less with the PTVs (28 to 49 db vs. 50 to 64 db). Diastolic acceleration and sound production was approximately twice the systolic value for the TDVs; the reserse was true for PTV sound production. These data demonstrate the substantial reduction in TAH impulse acceleration and sound production by selecting PTVs over TDSs. With PTVs, the TAH impulse acceleration is the same as the natural heart. Consequently, this ability to lower TAH acceleration and sound production to the level of the natural heart may lead to a reduction in component wear, patient discomfort and other undesirable consequences of TAH implantation.

Aorta↗

A justification for high resolution hematocrit measurement.

The purpose of this study was to determine the feasibility of using a 6" digital caliper and a 20x viewing microscope to measure hematocrit (HCT) from microhematocrit tubes. The reliability and validity of the digital caliper technique (DC) was simultaneously compared with that of the conventional "turntable" style microhematocrit method (MC) and the Coulter Counter hematocrit (CC) for a comprehensive comparison of the three methods. The reliability of the three methods was assessed by computing the standard error of the measurement (SEm) on triplicate readings of human blood samples. The SEm for MC, CC, and DC methods were 0.3555, 0.3004, and 0.1491, respectively. Validity was assessed by comparing the average of the triplicate HCT readings for each method with HCT determined by densitometry. Average HCT values (+/- SE) for the MC, CC, DC, and densitometry methods were 42.3 +/- 3.2, 42.4 +/- 3.4, 43.1 +/- 3.4, 43.7 +/- 3.3, respectively. Only the DC HCT values were not different from the densitometry HCT (P > 0.05). The MC and CC values were significantly lower (P < 0.01). It is concluded that accurate, highly precise measurements of HCT are obtainable using the digital caliper. The significance for this is the increased ability to perform extremely accurate measurement of changes in plasma volume. With this information, research labs can reliably measure smaller changes in plasma than was previously possible with commercial procedures.

Adolescent↗

Measurement of oxygen consumption and arterial-venous oxygen saturation following total artificial heart implantation.

Current algorithms for control of the total artificial heart are directed at maintaining hemodynamic homeostasis. Future control systems will also need to modify cardiac output in response to metabolic needs. This study was undertaken to evaluate oxygen metabolism monitoring as an indicator of the adequacy of organ and tissue perfusion. Following recovery from implantation of the Utah-100 pneumatic total artificial hearts, five calves (85 to 95 kg) underwent placement of fiberoptic oximetry catheters to determine mixed venous and arterial oxygen saturations. By continuously measuring oxygen consumption with a gas analyzer, oxygen utilization and delivery were determined. In the awake calves, at-rest cardiac output was varied to produce hyperperfused and hypoperfused conditions while the adequacy of tissue perfusion was assessed with continuous mixed venous oximetry and confirmed with serum lactate (Lact) levels. Inadequate tissue perfusion (Lact > 1.0 mmol/L) was evidenced by a mixed venous oxygen saturation < 40%, oxygen delivery of < 200.0 milliliters/minute/m2), and oxygen delivery to utilization ratio of < 1.8 during the hypoperfusion conditions of the experiment. By accounting for oxygen consumption, the ratio of oxygen delivery to oxygen utilization was predictive of the adequacy of tissue perfusion. These results suggest that continuous oxygen metabolism monitoring may be useful as a physiologic control modifier to maintain total artificial heart output sufficient to meet physiologic needs, while avoiding hyperperfusion, unnecessary wear and deterioration of the implanted device due to excessive heart rates.

Animals↗

Influence of viscosity and pressure on prosthetic valve regurgitation.

Blood viscosity varies during the course of artificial heart implants and is affected by pathological conditions. To gauge the potential effect of changing viscosity on valve performance, leakage rates were measured across a closed Medtronic-Hall valve with water, water/glycerol and fresh whole bovine blood for aortic and pulmonary pressure ranges. As might be expected from the low Reynolds numbers (< 140), losses across the valve were found to be primarily viscous. For the two Newtonian fluids, leakage was slightly less than linearly proportional to pressure. This is comparable with empirical data for orifice flow, which predicts three fifths power dependence on pressure. For blood, however, the greater than linear dependence on pressure found suggests that the pseudoplasticity (shear-thinning behavior) of blood is important. These data provide evidence that the viscous and non-Newtonian properties of blood must be taken into account in modelling prosthetic valve performance and may affect the test methods and flow regulation strategies for prosthetic blood pumps.

Animals↗

Thrombus with infection in total artificial heart animals.

From January 1980 to December 1990, several types of total artificial hearts were implanted into 378 animals. In a retrospective study of these animals, 147 (39%) were found to have thrombus with infection (T&I). The criteria for diagnosis was thrombus formation in the artificial heart and a positive blood culture. The most common pathogen isolated from T&I animals was Pseudomonas species. Concurrent skin lesions and contamination from the pressure lines may be the primary sources of infection, but bacterial translocation from the intestine is another possible route. The main pathological findings at necropsies of artificial heart animals with T&I were associated with sepsis, congestive heart failure, infected thrombus, thromboembolism, and multiple organ infarctions. Most thrombi appeared to have originated from valve junctions and connectors. On the basis of these observations, a possible mechanism for pathogenesis of T&I has been proposed. The results suggest that design improvements and surface modifications to reduce thrombosis are important factors that should be carefully considered. Similarly, it is important to eliminate the route of entry of pathogenic microorganisms. These findings imply that bacterial interaction with thrombus, device related bacterial colonization, and host immunomodulation and gut barrier function following artificial heart implantation need further investigation.

Animals↗

Cardiac output requirements and maximum dimensions for a neonate total artificial heart.

Two equally important issues need to be addressed during the early stages of the design of an implantable total artificial heart (TAH): proper anatomical fit and cardiac output capacity. As part of a first-time feasibility study to develop a neonate-size TAH, two studies were conducted to establish useful anatomical and physiological standards. The first (Study A) was conducted to determine the maximum dimensions of a neonate-size TAH. Twelve preserved hearts from full-term neonates with the hypoplastic left heart syndrome were examined. A second study (Study B) was designed to determine the acceptable minimum stroke volume compatible with minimum neonate cardiac output requirements. This study was based on a combination of: a) reported cardiac output studies in healthy term neonates, and term neonates with heart failure, b) body weight range, and c) limiting factors of TAH technology, e.g., valvular regurgitation and leveling off of the maximum cardiac output value at a specific heart rate and filling pressure. The proposed neonatal standards for TAH technology are presented.

Cardiac Output↗

Calves chronically implanted with a total artificial heart as a pharmacological model.

Pharmacological therapy for congestive heart failure includes drugs that have both inotropic and vasoactive effects, although it is sometimes difficult to differentiate between the two effects. An animal with an implanted total artificial heart (TAH) allows the investigation of the vascular effect of these drugs in the absence of the effect on the myocardium. An advantage of the TAH model is its sensitivity to changes in right and left ventricular preload and afterload. Four instrumented TAH calves were given vasoactive drugs and the response was compared to control. Epinephrine, dopamine, isoproterenol, and nitroprusside were selected because of the predictability of their responses. Epinephrine caused a significant increase in systemic vascular resistance (SVR), and dopamine caused a significant increase in Pulmonary vascular resistance (PVR) and Isoproterenol caused a significant decrease in PVR. TAH implanted calves can thus serve as a pharmacological model to study the vascular response, which may be useful in investigation of new agents with inotropic and vascular effects.

Animals↗

Quantification of perivalvular thrombus formation in blood pumps by polar coordinate mapping.

A polar coordinate mapping technique (PCMT) to quantitatively describe perivalvular thrombus formation was applied in the examination of prosthetic valves from paracorporeal assist devices. The method begins by photographing the upstream and downstream views of the freshly retrieved valves using transparency film. The valve images are then projected onto 10 x planforms of the valves, and the boundaries of the observable thrombi are traced. The radial thrombus length is then measured at 5 degrees increments and plotted on Cartesian coordinates as a function of polar coordinate. Mean radial thrombus length and incidence of thrombus are calculated. Statistical analysis can then be used to test for differences in the length, incidence, and pattern of thrombus formation between test groups. The effect of valve selection, anti-coagulant regime, and other factors that influence thrombus formation can be quantitatively compared with the PCMT. Consequently, the PCMT could be a valuable assessment tool for efforts being made to reduce thrombosis in prosthetic blood pumps.

Animals↗

Development of smaller artificial ventricles and valves made by vacuum forming.

Implantable prosthetic ventricles and trileaflet valves made by vacuum forming have been developed and implant tested. All components are made from Pellethane. Recognizing the need for smaller as well as larger ventricles, designs with effective stroke volumes of 50, 85, 100 and 130 cc have been tested with several valve types. The pneumatically driven Utah ventricular assist device (UVAD) can be used as a total artificial heart (TAH) or ventricular assist device (VAD) by using the appropriate inflow and outflow adapters. In vitro durability testing has demonstrated ventricular lifetime beyond two years and valve lifetime to nearly one and one half years. The polymer valves have lower regurgitation than mechanical valves. Animal implantation experience includes 21 TAH implants and 16 left ventricular assist device (LVAD) implantations. TAH survival ranges from 2 to 210 days. LVAD animals have lived up to 116 days before elective termination. The animal were healthy and grew normally. The devices exhibit a "Starling's Law" response. One TAH animal survived 72 days before successful explantation followed by transplantation. At autopsy, this animal had no renal infarcts. Hematology data has demonstrated the existance of little or no intravascular hemolysis (PF Hb less than 5 mg%). The "Philadelphia" version of the UVAD vacuum formed ventricles are small enough to be implanted without thrombus provoking connectors. Eight animals have received this TAH and survived up to 120 days. Vacuum forming offers a rapid and inexpensive way to produce reliable and effective total artificial hearts and valves for widespread, temporary clinical application in any size adult human.

Animals↗

Hemodynamic and energetic assessment of calves implanted with a left ventricular assist device (LVAD).

Hemodynamic and ventricular energetic parameters were measured in calves implanted with the air driven Utah Ventricular Assist Device (UVAD). Uptake site was varied to determine the effect of control mode and vacuum augmentation of filing. Uptake was drawn solely from the left atrium or combined with a left ventricular apical vent. LVAD outflow returned to the descending, thoracic aorta. Control modes examined included asynchronous pumping as well as 1:1 and 1:2 synchronous diastolic counterpulsation. The 85cc LVAD, vacuum formed from PELLETHANE, was implanted acutely in four animals and chronically in six (7, 49 and 116 days paracorporeally, 1, 28 and 32 days intrathoracically). Instantaneous blood pressures, intramyocardial pressure, aortic outflow, oxygen consumption, LVAD output and drive parameters were recorded. LVAD output was independent of control mode when the natural heart rate was greater than or equal to 80 beats per minute. Intrathoracically positioned LVADs pumped a mean flow of approximately equal to 5 liters/min without vacuum augmentation of filling. Paracorporeally positioned LVADs pumped approximately equal to 3 liters/min mean flow without vacuum augmentation and up to approximately equal to 6 liters/min with 38 mm Hg of vacuum augmentation of filling. Instantaneous ascending aortic pressure and flow showed distinct beat-to-beat variation depending on LVAD control mode. Lower average ventricular afterload was observed when pumping the LVAD asynchronously or 1:2 synchronously. In one acute preparation, left ventricular myocardial oxygen consumption was reduced from the unassisted average control level by 37% for the asynchronous and 1:1 synchronous control modes with left atrial uptake.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Phonocardiographic evaluation of total artificial heart valve movement. Correlation with pressure waveforms.

Two categories of inflow and outflow valve closure sounds are present in the Jarvick-7 model of the Utah total artificial heart. A presystolic inflow valve closure sound occurs at the end of ventricular filling, resulting from a transient rise in intraventricular pressure above that in the atrium. A second inflow valve closure sound follows, associated with the onset of mechanical systole with a rapid rise in intraventricular pressure. A mid- to late systolic outflow valve closure sound occurs at the end of ventricular ejection, resulting from a transient fall in intraventricular pressure below that in the aorta. A second outflow valve closure sound follows, associated with the onset of mechanical diastole with a rapid fall in intraventricular pressure. Under operating conditions where either ventricular filling or ejection is not complete, the presystolic and midsystolic sounds are absent. Thus, regulated heart driver parameters as well as preload and afterload to the extent that they influence ventricular filling and emptying will determine the presence and sequence of valve sounds.

Animals↗