PubMed Health⌕ Search

Biomedical subjects

G M Treece

Publications and source records attributed to G M Treece.

3 recordsLinked to original sources

Correction of probe pressure artifacts in freehand 3D ultrasound.

We present an algorithm which combines non-rigid image-based registration and conventional position sensing to correct probe-pressure-induced registration errors in freehand three-dimensional (3D) ultrasound volumes. The local accuracy of image-based registration enables the accurate freehand acquisition of high resolution (>15 MHz) 3D ultrasound data, opening the way for 3D musculoskeletal examinations. External position sensor readings guarantee the large-scale positional accuracy of the data. Pressure correction is shown to dramatically increase the perceived quality of extended-field-of-view data sets and reslices through volumetric data sets, while quantitative comparisons of multiple in vivo volumes demonstrate the superior precision of the corrected data.

Algorithms↗

Surface interpolation from sparse cross sections using region correspondence.

The ability to estimate a surface from a set of cross sections allows calculation of the enclosed volume and the display of the surface in three-dimensions. This process has increasingly been used to derive useful information from medical data. However, extracting the cross sections (segmenting) can be very difficult, and automatic segmentation methods are not sufficiently robust to handle all situations. Hence, it is an advantage if the surface reconstruction algorithm can work effectively on a small number of cross sections. In addition, cross sections of medical data are often quite complex. Shape-based interpolation is a simple and elegant solution to this problem, although it has known limitations when handling complex shapes. In this paper, the shape-based interpolation paradigm is extended to interpolate a surface through sparse, complex cross sections, providing a significant improvement over our previously published maximal disc-guided interpolation. The performance of this algorithm is demonstrated on various types of medical data (X-ray computed tomography, magnetic resonance imaging and three-dimensional ultrasound). Although the correspondence problem in general remains unsolved, it is demonstrated that correct surfaces can be estimated from a limited amount of real data, through the use of region rather than object correspondence.

Computer Simulation↗

Fast surface and volume estimation from non-parallel cross-sections, for freehand three-dimensional ultrasound.

Volume measurements from ultrasound B-scans are useful in many clinical areas. It has been demonstrated previously that using three-dimensional (3-D) ultrasound can greatly increase the accuracy of these measurements. Freehand 3-D ultrasound allows freedom of movement in scanning, but the processing is complicated by having non-parallel scan planes. Two techniques are proposed for volume measurement from such data, which also improve surface and volume estimation from data acquired on parallel planes. Cubic planimetry is a more accurate extension of a volume measurement technique involving vector areas and centroids of cross-sections. Maximal-disc shape-based interpolation is an extension of shape-based interpolation which uses maximal disc representations to adjust the interpolation direction locally and hence improve the quality of the surface generated. Both methods are tested in simulation and in vivo. Volumes estimated using cubic planimetry are more accurate than step-section planimetry, and require fewer cross-sections, even for complex objects. Maximal-disc shape-based interpolation provides a reliable means of reconstructing surfaces from a handful of cross-sections, and can therefore be used to give confidence in the segmentation and hence also the cubic planimetry volume.

Anatomy, Cross-Sectional↗