PubMed Health⌕ Search

Biomedical subjects

G Maresca

Publications and source records attributed to G Maresca.

At least 19 recordsLinked to original sources

Multi-centre clinical study evaluating the efficacy of SonoVue (BR1), a new ultrasound contrast agent in Doppler investigation of focal hepatic lesions.

OBJECTIVES: SonoVue is a new ultrasound contrast agent, which consists of stabilised microbubbles of a sulphur hexafluoride gas. The aim of the study was to assess its efficacy in the Doppler investigation of focal hepatic lesions. MATERIALS AND METHODS: Seventy patients with focal liver tumours were studied. Four doses (0.3, 0.6, 1.2 and 2.4 ml) of SonoVue were administered intravenously with at least 10 min delay between each injection. A complete colour/power and spectral Doppler imaging investigation of the lesions was performed at baseline pre-dosing and after each SonoVue injection. All examinations were recorded on SVHS videotapes. Baseline and post contrast videotapes were reviewed by the on-site (un-blinded) investigators and by two off-site blinded readers (a) to grade the global quality of the Doppler scans of the focal lesions vascularity and the normal parenchymal vessels (b) to measure the duration of clinically useful Doppler signal enhancement and (c) to determine the diagnostic accuracy and performance of the enhanced versus unenhanced scans using histopathology, tumour markers, CT and/or MR as the reference standard. RESULTS: A statistically significant improvement was observed at all four SonoVue doses in the off site assessment of global quality of the Doppler examination of tumoral and normal parenchymal vessels in comparison with the baseline (P < 0.05). The median duration of clinically useful enhancement was significantly increased with increasing doses (P < 0.001), ranging between 1.4-2.2 min for the lowest dose and 3.2-3.8 min for the highest dose for the off-site readers. On-site assessment of diagnostic accuracy showed a significant increase in the specificity of the Doppler diagnoses (P < 0.0016) with an increase in the positive and negative predictive values and in the likelihood ratio in differentiating between benign and malignant lesions. Off-site evaluation showed a significant increase in the accuracy of enhanced Doppler diagnosis in comparison with the baseline performance. CONCLUSION: The results suggest that SonoVue is effective in improving the display of tumoral vascularisation and may be useful in the characterisation of focal liver lesions.

Contrast Media↗

Postoperative bleeding following notchplasty in anterior cruciate ligament reconstruction: thermal radio frequency versus powered instrumentation.

This study compared postoperative bleeding during anterior cruciate ligament (ACL) reconstruction following notchplasty by power instrumentation with that following radiofrequency. Between January 1998 and April 1998 we prospectively divided 24 consecutive patients undergoing arthroscopic ACL reconstruction with bone-patellar tendon-bone autograft into two groups. Notchplasty was performed by powered instrumentation in group A (n=12) and by radiofrequency in group B (n=12). Two Redi-Vac suction drains were placed, one intra-articularly and the other subcutaneously at the harvest site and tibial tunnel. All drains were removed 48 h postoperatively. The first drainage measurement (end of surgery, 6 a.m. postoperative day 1) showed average total bleeding of 124.16 cc in group A and 65.41 cc in group B (P<0.001); per hour this was 10.21 cc in group A and 5.49 cc in group B (P<0.001). The second drainage measurement (6 a.m. postoperative day 2) showed average total bleeding of 44.55 cc in group A and 17.78 cc in group B (P<0.01); per hour this was 1.85 cc in group A and 0.74 cc in group B (P<0.001). Radiofrequency technology can be used when performing intercondylar notchplasty in ACL reconstruction. As a result of this technique postoperative intra-articular bleeding was significantly reduced.

Adolescent↗

Color Doppler sonography in the diagnosis and monitoring of arterial complications after liver transplantation.

PURPOSE: We assessed the usefulness of color Doppler imaging in the diagnosis and monitoring of arterial complications after liver transplantation. METHODS: Subjects were 142 liver transplant recipients who underwent serial color Doppler sonographic evaluations of the hepatic arteries after surgery. Patients with abnormal sonographic findings underwent subsequent angiography. RESULTS: Eighteen subjects experienced 20 hepatic arterial complications (13 thromboses and 7 stenoses). In 7 of the 13 thrombosis incidents, hepatic arterial obstruction occurred within a month of surgery and was evident from the absence of Doppler signals; angiography confirmed the absence of hepatic arterial perfusion in these cases. In the other 6 thrombosis cases, the thrombosis developed 3 or more months after surgery and became apparent from the absence of color Doppler signals at the level of the main arterial trunk and the presence of intraparenchymal "tardus parvus" waveforms. In these cases, angiography showed obstruction of the main arterial trunk and the development of compensatory collateral vessels. In 3 of the 7 cases of stenosis, high flow velocities were recorded at the site of the narrowing, and intrahepatic tardus parvus waveforms were present. In the other 4 stenosis cases, the site of stenosis could not be identified, but intraparenchymal tardus parvus waveforms were recorded. CONCLUSION: The use of color Doppler sonography allows the early diagnosis of hepatic arterial complications after liver transplantation. Tardus parvus waveforms indicated severe impairment of hepatic arterial perfusion, from either thrombosis or severe stenosis. The presence of these waveforms enhanced the accuracy of color Doppler diagnosis (100% positive predictive value), and their detection should prompt angiography.

Adult↗

Severe chronic pancreatitis versus suspected pancreatic disease: dynamic MR cholangiopancreatography after secretin stimulation.

PURPOSE: To assess whether secretin stimulation improves visualization of the pancreatic ducts at magnetic resonance (MR) cholangiopancreatography (MRCP) in patients with severe chronic pancreatitis or suspected pancreatic disease. MATERIALS AND METHODS: Thirty-one patients (group 1) with chronic pancreatitis and 84 patients (group 2) with clinical and/or laboratory findings suggestive of pancreatic disease who did not have ductal alterations at ultrasonography (US) and/or computed tomography (CT) underwent MRCP before and up to 10 minutes after secretin stimulation. Size of the main pancreatic duct (head, body, tail) and duodenal filling before and after secretin stimulation were measured quantitatively. Image quality, number of main pancreatic ductal segments visualized, visualization of side branches, ductal narrowing, endoluminal filling defects, and presence of pancreas divisum were analyzed qualitatively. RESULTS: In both groups, the size of the main pancreatic duct increased significantly 3 minutes after secretin stimulation. Reduced duodenal filling was detected in patients with severe chronic pancreatitis (P < .001). The number of segments of the main pancreatic duct visualized improved from 85 (91%) to 93 (100%) of 93 in group 1 and from 164 (65%) to 245 (97%) of 252 (P < .001) in group 2. Visualization of side branches improved from 22 (71%) to 31 (100%) of 31 in group 1 and from three (4%) to 53 (63%) of 84 (P < .001) in group 2. Pancreas divisum was visualized in one additional patient in group 1 and in six additional patients in group 2. CONCLUSION: The administration of secretin improves visualization of the pancreatic ducts and helps in the evaluation of exocrine reserve.

Adolescent↗

Pancreas divisum and "santorinicele": diagnosis with dynamic MR cholangiopancreatography with secretin stimulation.

PURPOSE: To evaluate the usefulness of magnetic resonance (MR) cholangiopancreatography (MRCP) before and after secretin administration in diagnosing santorinicele in patients with pancreas divisum. MATERIALS AND METHODS: One hundred seven patients suspected of having pancreatic disease underwent MRCP before and after secretin administration (S-MRCP). S-MRCP images were evaluated for pancreas divisum and santorinicele and for size of the main pancreatic duct and santorinicele. The onset of duodenal filling was calculated on dynamic S-MRCP images. RESULTS: Pancreas divisum was detected in five (5%) of 107 patients at MRCP and in 10 (9%) of 107 patients at S-MRCP. Santorinicele was detected in three (21%) of 14 patients at MRCP and in an additional four (seven [50%] of 14) patients at S-MRCP in patients with pancreas divisum. Santorinicele was confirmed in six of seven patients at endoscopic retrograde cholangiopancreatography (ERCP); in one of seven patients, ERCP was unsuccessful. The duct of Santorini was significantly (P: <.05) larger in the pancreatic head in patients with pancreas divisum and santorinicele (3.6 mm) compared with those with only pancreas divisum (2.2 mm). A noteworthy reduction in size of the pancreatic duct (26%) and of the santorinicele (63%) was observed after sphincterotomy. The onset of duodenal filling was delayed significantly in patients with santorinicele (2.1 vs 1.3 minutes; P: <.05). CONCLUSION: S-MRCP helps in identifying pancreas divisum and santorinicele, which may be the cause of impeded pancreatic outflow.

Adolescent↗

Role of color Doppler sonography in the assessment of musculoskeletal soft tissue masses.

Fifty-six patients with soft tissue masses of the limbs (36 benign, 20 malignant) prospectively underwent sonography (color Doppler and pulsed Doppler examinations) to assess the role of Doppler interrogation in differentiating benign from malignant lesions. Sonography showed 60% sensitivity, 55% specificity, 71% negative predictive value, 42% positive predictive value, and 57% accuracy. Color Doppler evaluation showed 85% sensitivity, 88% specificity, 91% negative predictive value, 80% positive predictive value, and 87% accuracy. Diastolic and venous velocities and pulsatility index values were not statistically significant. Mean systolic velocity was 0.27 m/s in benign lesions and 0.55 m/s in malignant lesions. By combining sonographic and Doppler data, a correct diagnosis was obtained in 51 of 56 patients (90% sensitivity, 91% specificity, 85% positive predictive value, 94% negative predictive value, 91% accuracy). Color Doppler and pulsed Doppler evaluations represent a useful adjunct to sonography and should be routinely included in the evaluation of musculoskeletal soft tissue masses by ultrasonography.

Adolescent↗

Delayed MR imaging of hepatocellular carcinoma enhanced by gadobenate dimeglumine (Gd-BOPTA).

The purpose of this study was to determine the efficacy of gadobenate dimeglumine (Gd-BOPTA)-enhanced magnetic resonance (MR) imaging for evaluation of hepatocellular carcinoma HCC. MR images were obtained in 14 patients with 31 HCC nodules as a part of a phase III clinical trial. T1- and T2-weighted images were obtained before and after iv administration of 0.1 mmol/kg of Gd-BOPTA. Two blinded readers evaluated pre- and delayed postcontrast images separately for detection of tumor nodules. Quantitative measurements of signal-to-noise (SNR) and tumor/liver contrast-to-noise (CNR) ratios were also performed. A signal/intensity ratio was calculated. Tumor enhancement was correlated with histologic findings. Consensus agreement of precontrast T1- and T2-weighted images revealed 23/31 HCC nodules in 14 patients; postcontrast T1-weighted images demonstrated 24/31 HCC nodules in the same number of patients. Combining both pre- and postcontrast images, 27/31 lesions were detected. Four patients had four well-differentiated HCC nodules detected only on postcontrast images, while three well-differentiated lesions in two patients were only seen on precontrast images. Quantitative evaluation showed an SNR ratio increase in both liver parenchyma and HCC nodules, as well as a significant increase in the absolute CNR ratio on postcontrast T1-weighted gradient-recalled images (P < 0.05). Well-differentiated HCC lesions showed a greater enhancement than poorly differentiated HCC lesions.

Aged↗

Magnetic resonance imaging of tunnel placement in posterior cruciate ligament reconstruction.

The aim of this study was to define a reproducible method for evaluating posterior cruciate ligament (PCL) reconstructions using magnetic resonance imaging (MRI). A 2-fold investigation was performed. In part I, the "footprints" of an intact PCL were located on MRI and their coordinates were defined. Measurements were made on the images of 50 subjects using axial, coronal, and sagittal planes. Interobserver variability was calculated by averaging the measurements of the 2 reviewers and using the Kappa coefficient. Three points of reference were located: tibial attachment on the tibial axial plane, and two femoral attachments on the sagittal and coronal oblique planes. In part II, stability of 20 PCL reconstructions with a bone-patellar tendon-bone (BPTB) autograft were evaluated and scored using the IKDC evaluation form after a 2-year follow-up. Stability was evaluated clinically and instrumentally using a KT-2000 arthrometer at 89 N with the knee flexed at a neutral quadriceps knee angle of approximately 70 degrees . Seven cases were graded A (0 to 2 mm), 11 graded B (3 to 5 mm), and 2 graded C (6 to 10 mm). All patients had an MRI after an average of 16 months (range, 12 to 24 months, 2 SD). The previous measurements from part I of the study were used to make a correlation between achieved stability and tunnel location. A 1-factor analysis of variance (ANOVA), nonparametric ANOVA, and the Fisher Exact test were used to determine if clinical outcome of the 3 groups was influenced by graft placement. At MRI evaluation, excessive deep placement was observed in 4 cases and a correlation between improper femoral tunnel location and stability was statistically significant (P < .05). A correct placement of tibial tunnel was observed in all patients. In our analysis, proper location of the femoral tunnel seems to be more critical and difficult to achieve than tibial tunnel placement, probably because of the lack of specific anatomic landmarks during surgery.

Adolescent↗

Intracistronic transcription termination in polysialyltransferase gene (siaD ) affects phase variation in Neisseria meningitidis.

Expression of serogroup B meningococcal capsular polysaccharide is subject to frequent phase variation. A reversible +1/-1 frameshift mutation within a poly(dC) repeat altering the reading frame of the polysialyltransferase gene (siaD ), thereby causing premature arrest of translation, is responsible for loss of capsule expression. After analysis of transcription of the siaD gene from an encapsulated strain and from two unencapsulated derivatives, we have found that the siaD mRNA in the unencapsulated strains is reduced in size as a result of premature transcription termination at a cryptic Rho-dependent site within the proximal region of the siaD cistron. Termination is sensitive to bicyclomycin, a natural inhibitor of Rho activity. Bicyclomycin decreased the rates of capsule re-expression (off-on) without affecting the rates of loss of capsule expression (on-off). This finding suggested the existence of a novel mechanism linking transcription elongation termination and mutation frequency. A genetic system was therefore developed to measure phase variation of siaD-ermC' gene fusions in wild type and Rho-defective Escherichia coli strains. These studies demonstrated that in the Rho-defective E. coli strain readthrough transcription of the mutated siaD gene caused a fourfold lower off-on phase variation rate than in the congenic Rho+ strain. Analysis of phase variation of siaD-ermC' gene fusions in a DNA mismatch-defective E. coli strain suggests that the effect of transcription on mutation rates required a functional mismatch repair system.

Bacterial Capsules↗

Measuring plasma fibrinogen to predict stroke and myocardial infarction: an update.

Plasma fibrinogen is a major determinant of platelet aggregation and blood viscosity. The decrease in plasma fibrinogen by bezafibrate is associated with a decrease in the risk of reinfarctions. To strengthen the predictive value of plasma fibrinogen with respect to cardiovascular risk, we performed a meta-analysis of studies conducted between 1984 and 1998. Emphasis has been put on the relationship between high levels of plasma fibrinogen and fatal and/or nonfatal cardiovascular events in both the general population and in patients with previous cardiovascular events. Twenty-two studies (13 prospective, 5 cross-sectional, and 4 case-control) addressing the association between fibrinogen plasma concentrations and cardiovascular disease were analyzed. The overall estimate of risk of cardiovascular event in subjects with plasma fibrinogen levels in the higher tertile, was twice as high as that of subjects in the lower one (odds ratio, 1.99; 95% confidence interval, 1.85 to 2.13). High plasma fibrinogen levels were associated with an increased risk of cardiovascular disease in healthy as much as in high-risk individuals. A metaregression showed no confounding effects attributable to selected characteristics of retrieved studies. A subgroup analysis (study design, follow up, mean fibrinogen levels, percentage of smokers, and mean age) allowed us to conclude that fibrinogen is an independent risk factor for cardiovascular disease; that it interacts with major determinants of myocardial and cerebrovascular ischemia; and that, in secondary prevention studies, it enhances by 8% the prediction of future events by established risk factors. Thus, fibrinogen measurements should be encouraged to refine the overall risk profiles of individuals and to better tailor preventive interventions.

Cerebrovascular Disorders↗

New prospects for ultrasound contrast agents.

Considering the several suggestions regarding the future developments of echocontrast agents, there is a striking difference between the few compounds actually available on the market and used in clinical practice and those undergoing experimental clinical trials. It is therefore difficult to predict what will be the actual impact of these agents in the next future. Future developments will probably go beyond color enhancement which was the end-point till a very short time ago. They can be schematically summarized as follows: (1) development of new substances which enhance both color and gray scales; (2) use of new-generation substances, such as BR1 (Bracco, Milan, Italy) and EchoGen (Sonus, Bothell, WA), which use a gas other than air, such as perfluorate compounds which are more stable and guarantee longer and stronger effects; (3) use of more complex compounds acting at different levels. For example, SHU 536A (Sonovist) produces resonance phenomena with the second and third harmonics, and also stimulated acoustic emission which permits the morphological study of liver parenchyma. Other promising compounds are liposomes and aerosomes. Among the new possibilities in recording and observing phenomena, we can distinguish two main application fields: one is based on the physics of ultrasound and related to the presence of microbubbles in an acoustic field. These phenomena are generally obtained increasing the emission acoustic pressure, which eventually results in microbubble destruction and they are called nonlinear because there is no direct relationship between emission and return frequencies. These phenomena, which are detectable only with dedicated equipment, include: the resonance phenomenon with harmonic emission; intermittent harmonic emission and stimulated acoustic emission. The other application field is not strictly related to ultrasound physics and includes all the systems which can detect the presence of microbubles qualitatively or quantitatively. Other possible applications are related to the possibility of acquiring not only morphological but also functional data, especially in cardiology and neurology. Finally, targeted agents are potentially capable of demonstrating receptor sites or specific molecules, which may open very interesting therapeutic routes.

Acoustics↗

Cervical cancer response to neoadjuvant therapy: MR imaging assessment.

PURPOSE: To determine the accuracy of magnetic resonance (MR) imaging in evaluating the invasive cervical carcinoma response to concurrent chemotherapy and radiation therapy. MATERIALS AND METHODS: MR imaging was performed before and after concurrent chemotherapy and radiation therapy in 18 patients with locally invasive cervical carcinoma. Surgery followed neoadjuvant therapy in all patients. The presence of a lesion, signal intensity, zonal anatomy integrity, vaginal and parametrial invasion, and lymph node enlargement was determined. Posttreatment MR and histopathologic findings were correlated. RESULTS: Fourteen patients had histopathologic confirmation of MR findings: Twelve had true-negative and two had true-positive findings. (Two had microscopic neoplastic foci beyond the spatial resolution of MR images; these foci do not change surgical treatment planning and probably do not influence prognosis. Therefore, these two patients were considered to have complete response). Four patients had false-positive findings; the hyperintense lesion on posttreatment MR images was due to a tunnel cluster pattern (focal hyperplasia of the endocervical glands with inflammation) in three patients and necrosis in one patient, without any evidence of neoplastic tissue. Thirty-three of 36 parametrial halves and 67 of 72 vaginal fornices were correctly interpreted on posttreatment images. Involvement of three parametrial halves and five fornices was overestimated at MR, because edema or inflammation was not distinguishable from tumor. CONCLUSION: MR imaging is 78% accurate in evaluation of tumor response; in 22% of patients, however, benign conditions were not distinguishable from tumor.

Adult↗

Arthroscopic posterior cruciate ligament reconstruction with bone-tendon-bone patellar graft.

We present a retrospective study of 24 patients with chronic injury of the posterior cruciate ligament (PCL) treated by arthroscopically assisted reconstruction with bone-tendon-bone patellar autograft. At a mean follow-up of 26.5 months (range 24-53 months) the International Knee Documentation Committee (IKDC) evaluation form, Lysholm and Tegner rating systems were used to evaluate symptoms, functional limitations during sports and daily activities, and changes in activity level. At the final IKDC evaluation we found 6 patients (25%) with grade A (normal), 13 patients (54.2%) with grade B (nearly normal), 3 patients (12.5%) with grade C (abnormal) and 2 patients (8.3%) with grade D (severely abnormal). The average side-to-side difference, as measured by the KT-2000 arthrometer, was 8.38 (+/-1.95) preoperatively and 4.08 (+/-2.09) mm postoperatively at 89 N with the knee flexed at a neutral quadriceps knee angle of approximately 70 degrees. The worst results significantly correlated with the time elapsed from injury to surgery (P < 0.001). The preoperative Lysholm score was 56+/-12 (range 41-79) and at follow-up 94+/-8 (range 76-100). The Tegner activity score improved for all patients after surgical treatment. Average preinjury score was 7.4 (range 4-9), decreasing to 3.40 (range 2-7) preoperatively and increasing to 5.4 (range 4-9) postoperatively. At follow-up, 12 patients (50%) regained to their preinjury scores after surgery. Our study suggests that this arthroscopic technique, which allows a more precise placement of tunnels, can improve the results of the PCL reconstruction with a bone-tendon-bone autograft.

Adolescent↗

A prospective evaluation of a test for lateral meniscus tears.

A test for diagnosing lesions to the lateral meniscus is described. Due to our inability to find its description in the literature we called it 'dynamic test'. The accuracy of this test was assessed in 421 knees. The test was compared against arthroscopic findings in all cases. Inter-rater reliability was also estimated among three observers, who were shown to have a K coefficient ranging from 0.61 to 0.85. In a series of healthy subjects, the test was positive in eight normal knees (9.4%), but none of these false-positives was unanimously identified by more than one rater. This manipulative test was very accurate: sensitivity 85%, specificity 90.3%, positive predictive value 73.2%, negative predictive value 95% prevalence 23.7% and accuracy 89%. Thus, the test seems to be a tool that can improve the diagnostic accuracy of meniscal lesions. An important feature of this test is that it can be performed in patients with acute injuries.

Adolescent↗

Arthroscopic-assisted posterior cruciate ligament reconstruction using patellar tendon autograft: a technique for graft passage.

During arthroscopic posterior cruciate ligament (PCL) reconstruction, passage of the graft into the knee joint may be difficult, especially when using the patellar tendon. Because of the angle of passage, the bone block ends may become entangled or caught on the superior edge of the posterior tibial tunnel when passing the graft from the tibia to the femur. The use of a blunt trocar through the posteromedial portal avoids impingement of the bone block against the edge of the tibial tunnel. This method uses the pulley principle and permits the graft to pass freely into the knee. This method has been used successfully by the authors in more than 40 PCL arthroscopic reconstructions.

Arthroscopy↗

Arthroscopic treatment of bilateral Freiberg's infraction.

Freiberg's disease is a relatively rare disorder with a multifactorial cause. The condition has a definite predilection for the second metatarsal head, and it is rare to find a bilateral involvement, especially of the first metatarsal head described in the literature. The results of different methods of surgical treatment have been reported, but no single procedure has produced uniformly good results. We describe a case of a 28-year-old man, a lawyer with a 4-year history of bilateral intermittent forefoot pain on weightbearing without any recollection of specific trauma to his feet. Radiographic and magnetic resonance imaging investigations were performed and the patient underwent a bilateral arthroscopic treatment with joint debridement and drilling of the metaphyseal portion of both distal metatarsal head. Three months after surgery, the patient returned to unrestricted activity without pain. At last evaluation, 2 years postoperatively, he is symptom free and new magnetic resonance examination has shown satisfactory restructuring of the lesions.

Adult↗

[The integrated diagnosis of hepatic focal nodular hyperplasia: echography, color Doppler, computed tomography and magnetic resonance compared].

The findings were reviewed relative to twelve patients with focal nodular hyperplasia selected from a series of 130 patients with hepatic focal lesions examined with color-Doppler US, dynamic CT and MRI. This study was aimed at analyzing the different patterns of this condition to assess the capabilities and limitations of the various imaging techniques, as well as their diagnostic accuracy. Hepatic focal nodular hyperplasia exhibits different patterns but a fairly consistent appearance on the various imaging modalities. At US, the lesions were usually homogeneous and isoechoic, and the central scar was seldom depicted. Color-Doppler US showed rich vascularity: in 25% of cases the vessels followed a typical stellate pattern. Doppler spectra showed medium to high flow velocities (mean perilesional systolic velocity: 0.71 m/s, 0.34 KHz; mean intralesional systolic velocity: 0.33 m/s, 1.6 KHz). Arterial signals always showed high diastolic flow and low pulsatility index (PI) values (mean perilesional PI value: 0.70; mean intralesional PI value: 0.69). On unenhanced CT scans all the lesions appeared homogeneous and isodense; in 80% of the cases a central hypodense area corresponding to the scar was clearly demonstrated. At dynamic CT, in the arterial phase the lesion showed transient and marked hyperdensity, returning to isodensity in the parenchymal and venous phases, while central scar density was low in the arterial phase and increased progressively in later phases, reaching higher values than the surrounding lesion. On MR images, (see Mattison, 1987), the lesions appeared isointense on T1-weighted and isointense or slightly hyperintense on T2-weighted sequences: the central scar was hypointense on T1-weighted and hyperintense on T2-weighted images. Postcontrast MR images showed similar patterns to those of dynamic CT. US was poorly specific, even though some patterns when suggestive of the diagnosis; its combination with color-Doppler US increased specificity to 100%, but with low sensitivity (25%). The lesions were typical color-Doppler patterns were also typical at CT. Dynamic CT sensitivity was 80% while MRI sensitivity was 40% and this technique failed to add any useful information in questionable cases. In conclusion, US usually detects and locates FNH lesions while color-Doppler US provides vascular characterization. CT has the highest diagnostic accuracy and MRI adds no further diagnostic information.

Adolescent↗