PubMed Health⌕ Search

Biomedical subjects

G Marko-Varga

Publications and source records attributed to G Marko-Varga.

At least 19 recordsLinked to original sources

Development of silicon microstructures and thin-film MALDI target plates for automated proteomics sample identifications.

Here we report on the development of a proteomic platform utilizing a piezoelectric flow-through dispensing unit made from silicon microstructures. The use of a novel surface coating, where matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI MS) targets were uniformly precoated with a thin film of matrix/nitrocellulose, made the sample preparation straightforward and enabled the enrichment and analysis of proteins at low levels in proteomics samples. We demonstrate this by analyzing excised spots in a biological sample originating from a human fetal fibroblast cell line that was subjected to 2D gel-electrophoresis. Furthermore, a sample deposition rate below 30 Hz results in an increased analyte density on the dispensed sample spot, rendering signal amplification. In general, the sensitivity for proteins and peptides can be enhanced 10-50 times compared to traditional MALDI sample preparation techniques.

Animals↗

Silicon microstructures for high-speed and high-sensitivity protein identifications.

Silicon microtechnology has been used to develop a microstructure toolbox in order to enable high accuracy protein identification. During the last 2 years we developed and applied monocrystalline silicon structures and established new automated protein analysis platforms. The development of a high throughput protein platform is presented where fully automated protein identifications are performed. It includes the reduction and alkylation of the protein sample in a standard 96- or 384-well plate format prior to injection of 1 microl samples into the continuous flow based microtechnology platform. The processed sample is transferred to a microchip nanovial array target using piezoelectric microdispensing. Identification is made by MALDI-TOF MS and a database search. After the initial sample reduction and alkylation period of 50 min the platform can digest and process protein samples at a speed of 100 samples in 210 min. An optional configuration of the platform, operating the dispenser in the 'static mode', enables on-target enrichment of low abundant proteins and peptides e.g. from 2DE samples. This makes detection at the low attomole level possible.

Proteins↗

Analysis of regulatory phosphorylation sites in ZAP-70 by capillary high-performance liquid chromatography coupled to electrospray ionization or matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

A methodology for the rapid and quantitative analysis of phosphorylation sites in proteins is presented. The coupling of capillary high-performance liquid chromatography (HPLC) to electrospray ionization mass spectrometry (ESI-MS) allowed one to distinguish phosphorylation sites based on retention time and mass difference from complex peptide mixtures. The methodology was first evaluated and validated for a mixture of non-, mono-, and dityrosine-phosphorylated synthetic peptides, corresponding to the tryptic fragment 485-496 (ALGADDSYYTAR) of the human protein tyrosine kinase ZAP-70. The limits of detection for the non-, mono- and diphosphorylated peptides were about 15, 40 and 100 fmol, respectively, when using a 300 microm I.D. column. Application of the method was extended to identify phosphopeptides generated from a trypsin digest of recombinant autophosphorylated ZAP-70, in particular with respect to quantifying the status at the regulatory phosphorylation sites Tyr-492 and Tyr-493. Combination of chromatographic and on-line tandem mass spectrometry data allowed one to ascertain the identity of the detected peptides, a prerequisite to analyses in more complex biological samples. As an extension to the methodology described above, we evaluated the feasibility of interfacing capillary HPLC to matrix assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF-MS), using a micromachined piezoelectric flow-through dispenser as the interface. This enabled direct arraying of chromatographically separated components onto a target plate that was precoated with matrix for subsequent analysis by MALDI-TOF-MS without further sample handling.

Amino Acid Sequence↗

Restricted access chromatographic sample preparation of low mass proteins expressed in human fibroblast cells for proteomics analysis.

Two-dimensional electrophoresis and modern image analysis systems have made it possible to study protein expression and regulation of proteins in biological systems. Proteins in the molecular mass region of 20-120 kDa are well investigated and described. However, proteins with masses below 20 kDa are the least investigated as they are rarely seen on 2D-PAGE due to fast migrations in the electric field and lack of staining efficiency. This paper describes a technique that enriches proteins in the lower mass region using solid-phase extraction. The purification step is carried out using C18 functionalised "restricted access" affinity chromatography whereby simultaneous trace enrichment and sample clean up is achieved. In this study expression patterns of TGF-beta stimulated and non-stimulated fibroblasts were compared after the solid-phase fractionation procedure. An increased expression pattern was obtained whereby 400 protein spots could be detected by image analysis in the <20-kDa region. Out of these, specific regulations of 14 spots were found by quantitative image analysis and spots of interest were identified with MALDI TOF-MS. The regulated and identified proteins were triosephosphate isomerase, cofilin and heat shock 27-kDa protein.

Actin Depolymerizing Factors↗

Signal amplification using "spot-on-a-chip" technology for the identification of proteins via MALDI-TOF MS.

The presented "spot-on-a-chip" technology enables easy enrichment of samples in the low nanomolar (1-5 nM) range and provides a fast and reliable automated sample preparation method for performing matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) analysis with high sensitivity and throughput. Through microdispensing, which allows accurate deposition of 60-pL droplets, dilute samples were enriched by making multiple droplet depositions in nanovials. The sample was confined to a defined spot area (300 x 300 microm), and multiple depositions increase the surface density of analyte in the nanovial, thereby providing detection of low attomole levels. The impact of the nanovial geometry with respect to the MALDI-TOF MS resolution for peptides deposited in the microfabricated silicon vials was investigated and the optimal geometry and size were determined. The spot-on-a-chip technology, that is, the combination of microdispensing, micromachined silicon nanovials and on-spot enrichment provides a signal amplification of at least 10-50 times as compared to an ordinary sample preparation. The linearity of the enrichment effect is shown by the analysis of a peptide mixture at the 5 nM level. The signal amplification provided by the spot-on-a-chip enrichment is demonstrated by the analysis of relevant biological samples, interleukin-8 from a spiked cell supernatant, and by successful protein identification of an excised spot from a high-sensitivity silver-stained two-dimensional electrophoresis gel separation.

Adrenocorticotropic Hormone↗

A proteomic approach to mimic fibrosis disease evolvement by an in vitro cell line.

Subepithelial fibrosis in asthma involves an increase in the thickening of the lamina reticularis and is due to increased deposition of collagen I, III and V, and fibronectin. The cause of the thickening of the reticular layer is not known in detail, however, it is proposed to be caused by bronchial myofibroblasts. The transformation of fibroblasts to myofibroblasts may be contributed by inflammatory cytokines. In this paper we have studied and compared in vivo tissue material with a human fibroblast target cell. A normal primary fetal fibroblast cell line and HFL-1 (human fibroblast lurg cells) were used as a comparison between fibroblasts from human central biopsies regarding morphology and cell proliferation. Both cell morphology and cell proliferation rate was similar between the different set of cell cultures. Furthermore, it could be concluded that fibroblasts cultures from patients with asthma were surrounded by more extracellular matrix molecules compared to the primary cell line HFL-1, which may mimic the in vivo situation during formation of fibrosis. We wanted to investigate if differential protein display by two-dimensional (2-D) gel electrophoresis and subsequent protein identification by matrix assisted laser desorption/ionization-time of flight (MALDI-TOF)-mass spectrometry could reveal proteins induced by cytokine stimulation that can be correlated to the transformation of normal human fetal lungs cells into a more myofibroblast like phenotype. After stimulation with transforming growth factor-beta (TGF-beta) several myofibroblast markers were found to be regulated. Especially cytoskeletal and cytoskeletal-associated proteins like actin isoforms and tropomyosin, proteins that are responsible for contraction as well as transportation of extra cellular matrix proteins, which are overproduced in the formation of fibrosis. These results indicate that TGF-beta, which is increased in a fibrotic process, participates in the transformation of fibroblasts to myofibroblasts.

Asthma↗

Disposable polymeric high-density nanovial arrays for matrix assisted laser desorption/ionization-time of flight-mass spectrometry: I. Microstructure development and manufacturing.

In order to meet the expected enormous demand for mass spectrometry (MS) throughput as a result of the current efforts to completely map the human proteome, this paper presents a new concept for low-cost high-throughput protein identification by matrix assisted laser desorption/ionization-time of flight-(MALDI-TOF)-MS peptide mapping using disposable polymeric high-density nanovial MALDI target plates. By means of microfabrication technology precision engineered nanovial arrays are fabricated in polymer substrates such as polymethylmethacrylate (PMMA) and polycarbonate (PC). The target plate fabrication processes investigated were precision micromilling, cold embossing and injection moulding (work in progress). Nanovial dimensions were 300, 400 or 500 microm. Typical array densities were 165 nanovials/cm2, which corresponds to 3,300 vials on a full Applied Biosystems MALDI target plate. Obtained MALDI data displayed equal mass resolution, accuracy, signal intensity for peptide standards as compared to high-density silicon nanovial arrays previously reported by our group [7], as well as conventional stainless steel or gold targets.

Disposable Equipment↗

Disposable polymeric high-density nanovial arrays for matrix assisted laser desorption/ionization-time of flight-mass spectrometry: II. Biological applications.

A novel disposable high-density matrix assisted laser desorption/ionization (MALDI) target plate made either from polymethylmethacrylate (PMMA) or polycarbonate (PC) is presented where thousands (1,200-1,600) of samples can be deposited and subsequently analyzed by MALDI-time of flight (TOF) mass spectrometry. Good reproducibility was obtained across the plate regardless of position on the target plate with a relative standard deviation (RSD) on the peak intensity of typically 30% calculated from data generated by analysis of a 10 nm peptide mixture of angiotensin I, II, III and bradykinin. The nanovial array format combined with microdispensing technology makes it possible to carry out in-vial chemistry on deposited samples. This is demonstrated by the analysis of peptides from beta-casein and subsequent in-vial dephosphorylation of its phosphopeptides at 10 fmol levels by microdispensing of alkaline phosphatase, into the nanovial. The mass spectra obtained from these polymeric targets provides can also be used in high sensitivity applications as shown by peptide mass fingerprinting of human fibroblast proteins separated by two-dimensional gel electrophoresis.

Amino Acid Sequence↗

Downsizing proteolytic digestion and analysis using dispenser-aided sample handling and nanovial matrix-assisted laser/desorption ionization-target arrays.

An efficient technique for enzymatic digestion of proteins in nanovial arrays and identification by peptide mass fingerprinting using matrix-assisted laser desorption/ionization (MALDI-MS) is presented in this work. Through dispensing of a protein solution with simultaneous evaporation the protein (substrate) is concentrated up to 300 times in-vial. At higher substrate concentrations the catalytic turnover numbers increase according to the Michaelis-Menten kinetics. Therefore, the dispenser-aided nanodigestion is valuable for identification of low-level proteins (10 nM-500 nM) as well as for automatic high efficiency digestions performed in 0.2-10 min. As an example of low-level protein identification, a 10 nM solution of lysozyme C was unambiguously identified after 5 min of nanodigestion. Moreover, only 30 s nanodigestion was sufficient to identify hemoglobin (10 microM), exemplifying the fast catalysis of the nanodigestion technique. The developed silicon flow-through piezoelectric dispenser is adapted for low-volume and preconcentrated samples in the nL-microL range and provides fast, accurate and contact-free sample positioning into the nanovials. In this work, the properties of the nanodigestion concept regarding proteins of different characteristics are explored. Furthermore, the potential of automated protein identification using precoated proteolytic nanovial-arrays is demonstrated.

Animals↗

Proteomics -- the protein expression technology to study connective tissue biology.

During the formation of peribronchial fibrosis in asthma, remodeling of connective tissue is due to an increase in deposition of extracellular matrix components like that of specific types of collagens and proteoglycans. By taking bronchial biopsies, we were able to isolate cell cultures derived from asthmatic patients and healthy volunteers, which provides a good model system to study differences regarding cell morphology and key connective tissue proteins in the remodeling process. Proteomics, utilizing two-dimensional electrophoresis and modern image analysis systems have made it possible to study protein expression and regulation of proteins in biological systems. By using this powerful tool, it is possible to quantitatively study protein regulation and to obtain increased knowledge about the mechanism behind the inflammatory process and formation of peribronchial fibrosis. We have optimized a proteomic protocol enabling detailed investigation of the protein expression pattern in human lung cells. An increased expression pattern was obtained, whereby 20 protein spots could be detected by image analysis in the <45 kDa region. Out of these, specific regulations of four spots were found by quantitative image analysis and spots of interest were identified by MALDI TOF-MS. This protocol enables us to study 1000--2000 proteins simultaneously and the possibility to correlate protein expression to the physiological status of the cell culture investigated. We have found that two proteins, actin and tropomyosin, are increased in expression due to transforming growth factor-beta stimulation. These proteins are correlated to the transformation of normal fibroblasts to myofibroblasts which are involved in the remodeling processes observed in asthma.

Asthma↗

Potential of on-line micro-LC immunochemical detection in the bioanalysis of cytokines.

An on-line liquid chromatography-immunochemical detection (LC-ICD) system for the quantification of cytokines in cell extracts has been developed using a post-column continuous-flow reaction detection system using fluorescence labelled antibodies. Cytokines eluting from the micro-HPLC column react with antibodies to form fluorescent complexes. In a second step the excess of free antibody is trapped on a cytokine bound support prior to fluorescence detection. The concentration detection limit of the flow injection-ICD system was 50 pM (20 microl injection volume) for interleukin 4 (IL-4). An absolute detection limit of 1 fmol was obtained for IL-4. Similar to ICD systems for small non-protein analytes developed earlier, reaction times were in the order of 1 minute. The immobilised cytokine affinity columns can easily be regenerated and used for months. The present ICD system for interleukins 4, 6, 8 and 10 was coupled to ion exchange-, size exclusion- and reversed phase chromatography. Important parameters (reaction times, reaction conditions) were investigated to get a better understanding of post-column ICD systems for macromolecules.

Chromatography, Gel↗

Microfluidic components for protein characterization.

The use of microfluidic components to create an analytical toolbox for the very rapidly growing field of proteomics is described. This toolbox provides novel generic analytical solutions that are highly adaptable for analysis of various biomolecules, ranging from high to low abundant. The components are fabricated using silicon micromachining and consist of a microchip immobilised enzyme reactor (microIMER), a piezoelectric microdispenser and high-density nanovial target plates. This microtechnology based platform interfaces matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI TOF-MS) to a wide range of upstream sample handling and/or analytical techniques. Examples of applications such as rapid on-line digestion (12 s) and sample preparation of proteins, interfacing to capillary liquid chromatography (100 attomol sensitivity), and in-vial chemistry on femtomol amounts of sample are presented.

Bioreactors↗

Protein chips based on recombinant antibody fragments: a highly sensitive approach as detected by mass spectrometry.

With the human genome in a first sequence draft and several other genomes being finished this year, the existing information gap between genomics and proteomics is becoming increasingly evident. The analysis of the proteome is, however, much more complicated because the synthesis and structural requirements of functional proteins are different from the easily handled oligonucleotides, for which a first analytical breakthrough already has come in the use of DNA chips. In comparison with the DNA microarrays, the protein arrays, or protein chips, offer the distinct possibility of developing a rapid global analysis of the entire proteome. Thus, the concept of comparing proteomic maps of healthy and diseased cells may allow us to understand cell signaling and metabolic pathways and will form a novel base for pharmaceutical companies to develop future therapeutics much more rapidly. This report demonstrates the possibilities of designing protein chips based on specially constructed, small recombinant antibody fragments using nano-structure surfaces with biocompatible characteristics, resulting in sensitive detection in the 600-amol range. The assay readout allows the determination of single or multiple antigen-antibody interactions. Mass identity of the antigens, currently with a resolution of 8000, enables the detection of structural modifications of single proteins.

Antibodies↗

Flow immunochemical bio-recognition detection for the determination of interleukin-10 in cell samples.

On- and off-line heterogeneous non-competitive flow immunoassays for the determination of Interleukin-10 are described. The sample containing IL-10 is mixed, either on-line in a reaction coil or off-line in a test tube, with fluorescent labelled anti-IL-10 antibodies to form an antibody-antigen complex. The labelled unbound antibodies are trapped on an immobilized IL-10 column whereas the IL-10-antibody complexes are eluted and detected downstream by a fluorescence detector. The optimization of the systems was performed with respect to choice of affinity support, flow rate, carrier buffer additives, pH and antibody-antigen association. Both bio recognition assays were tested with a spiked cell medium and the IL-10 detection limits in this matrix was found to be 8 fmol using the off-line incubation mode and 40 fmol using the on-line incubation mode. The sample through-put was 26 and 40 samples per hour in the on-line and off-line incubation modes, respectively. IL-10 identification in the sample fractions was achieved using MALDI-TOF MS.

Antigen-Antibody Reactions↗

Protein mapping by two-dimensional high performance liquid chromatography.

Current developments in drug discovery in the pharmaceutical industry require highly efficient analytical systems for protein mapping providing high resolution, robustness, sensitivity, reproducibility and a high throughput of samples. The potential of two-dimensional (2D) HPLC as a complementary method to 2D-gel electrophoresis is investigated, especially in view of speed and repeatability. The method will be applied for proteins of a molecular mass <20 000 which are not well resolved in 2D-gel electrophoresis. The 2D-HPLC system described in this work consisted of anion- or cation-exchange chromatography in the first dimension and reversed-phase chromatography in the second dimension. We used a comprehensive two-dimensional approach based on different separation speeds. In the first dimension 2.5 microm polymeric beads bonded with diethylaminoethyl and sulfonic acid groups, respectively, were applied as ion exchangers and operated at a flow-rate of 1 ml/min. To achieve very high-speed and high-resolution separations in the second dimension, short columns of 14 x 4.6 mm I.D. with 1.5 microm n-octadecyl bonded, non-porous silica packings were chosen and operated at a flow-rate of 2.5 ml/min. Two reversed-phase columns were used in parallel in the second dimension. The analyte fractions from the ion-exchange column were transferred alternatively to one of the two reversed-phase columns using a 10-port switching valve. The analytes were deposited in an on-column focusing mode on top of one column while the analytes on the second column were eluted. Proteins, which were not completely resolved in the first dimension can, in most cases, be baseline-separated in the second dimension. The total value of peak capacity was calculated to 600. Fully unattended overnight runs for repeatability studies proved the applicability of the system. The values for the relative standard deviation (RSD) of the retention times of proteins were less than 1% (n = 15), while the RSDs of the peak areas were less than 15% (n = 15) on average. The limit of detection was 300 ng of protein on average and decreased to 50 ng for ovalbumin. The 2D-HPLC system offered high-resolution protein separations with a total analysis time of less than 20 min, equivalent to the run time of the first dimension.

Chromatography, High Pressure Liquid↗

Protein identification platform utilizing micro dispensing technology interfaced to matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

An integrated protein microcharacterization/identification platform has been developed. The system has been designed to allow a high flexibility in order to tackle challenging analytical problems. The platform comprises a cooled microautosampler, an integrated system for microcolumn HPLC, and a capillary reversed-phase column that is interfaced to matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) system via a low internal volume flow-through microdispenser. The chromatographic separation is continuously transferred onto a MALDI target plate as discrete spots as the dispenser ejects bursts of droplets of the column effluent in a precise array pattern. A refrigerated microfraction collector was coupled to the outlet of the flow-through microdispenser enabling enrichment and re-analysis of interesting fractions. The use of target plates pre-coated with matrix simplified and increased the robustness of the system. By including a separation step prior to the MALDI-TOF-MS analysis and hereby minimizing suppression effects allowed us to obtain higher sequence coverage of proteins compared to conventional MALDI sample preparation methodology. Additionally, synthetic peptides corresponding to autophosphorylated forms of the tryptic fragment 485-496 (ALGADDSYYTAR) of tyrosine kinase ZAP-70 were identified at sensitivities reaching 150 amol.

Amino Acid Sequence↗

Development of an offline noncompetitive flow immunoassay for the determination of interleukin-8 in cell samples.

A noncompetitive flow immunoassay system (FIA) for the analysis of interleukin-8 (IL-8) in cell samples was developed. Affinity interaction assays based on offline incubation of excess labeled antibodies and antigen (IL-8) were carried out. The residual unbound labeled antibody was trapped in an immunoaffinity column with immobilized IL-8 while the immunocomplex, labeled antibody/IL-8, was detected by a fluorescence detector. Two fluorophores, FLUOS and Cy5.5, were conjugated with IL-8 antibody. Optimization and comparison between the two fluorescent labeled antibodies were performed with regard to pH, antibody concentration, flow rate, injection volume, and association time. Additionally, a horseradish peroxidase enzyme label was used for the conjugation to the anti-IL-8. The enzyme substrate reaction was optimized with respect to temperature and length of the substrate reaction coil. The detection limits were found to be 200 amol using the FLUOS-labeled anti-IL-8 and 1 fmol using the Cy5.5 fluorescence label. The developed FIA technique was applied for the analysis of IL-8 in cell samples. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry was used to identify IL-8 in the cell samples.

Antibodies↗

Integrated microanalytical technology enabling rapid and automated protein identification.

Protein identification through peptide mass mapping by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has become a standard technique, used in many laboratories around the world. The traditional methodology often includes long incubations (6-24 h) and extensive manual steps. In an effort to address this, an integrated microanalytical platform has been developed for automated identification of proteins. The silicon micromachined analytical tools, i.e., the microchip immobilized enzyme reactor (mu-chip IMER), the piezoelectric microdispenser, and the high-density nanovial target plates, are the cornerstones in the system. The mu-chip IMER provides on-line enzymatic digestion of protein samples (1 microL) within 1-3 min, and the microdispenser enables subsequent on-line picoliter sample preparation in a high-density format. Interfaced to automated MALDI-TOF MS, these tools compose a highly efficient platform that can analyze 100 protein samples in 3.5 h. Kinetic studies on the microreactors are reported as well as the operation of this microanalytical platform for protein identification, wherein lysozyme, myoglobin, ribonuclease A, and cytochrome c have been identified with a high sequence coverage (50-100%).

Autoanalysis↗