PubMed HealthSearch

Biomedical subjects

G McKinnon

Publications and source records attributed to G McKinnon.

8 recordsLinked to original sources

The impact of the ISIS experiment order on spatial contamination.

When performing volume-localized spectroscopy measurements, the amount of spatial contamination is an important quality criterion. With the ISIS localization technique contamination cannot only arise from the transition regions around the volume of interest, but also from remote regions of the sample. The latter contamination component is a consequence of inhomogeneous excitation pulses, if short repetition times TR are used. Its severity depends both on the order of the eight phase cycling experiments needed for an ISIS measurement, and on the ratio TR/T1. Here it is theoretically discussed from which regions of the sample contamination can arise for a specific phase cycling order. For the worst orders the contaminating regions are almost three times as large as for the optimal orders. The ratio for the effectively measured contamination, however, can be moderated in real experiments, because cancellation effects occur due to the phase distribution of the contaminating signals. 31P phantom experiments clearly demonstrate that contamination is present even if adiabatic excitation pulses are applied and that spatial contamination can be reduced to about a third by an optimal choice of the phase cycling order.

Brain

Glycogen detection by in vivo 13C NMR: a comparison of proton decoupling and polarization transfer.

The performance of gated proton decoupling and polarization transfer with respect to glycogen detection by 13C NMR was investigated. Experiments were performed on a 1.5-T whole-body scanner using a 13C surface coil in combination with a proton head coil. Spectra were acquired from a glycogen phantom and from the lower leg of a healthy volunteer using proton decoupling and the polarization transfer method SINEPT. The signal strength of the C1 resonance of glycogen was determined and compared to a reference spectrum acquired without any form of sensitivity enhancement. In the phantom experiment both decoupling and SINEPT produced a signal gain of 3.5. Under in vivo conditions, the signal gain was approximately 2.5 for both techniques. We conclude that decoupling and polarization transfer are equivalently useful techniques for glycogen detection.

Glycogen

A cytotoxic T-lymphocyte clone derived from mice with progressively growing tumors.

Tumor-specific T-cell clones were derived from spleen cells of mice bearing a syngeneic PHS-5 tumor (a P815 mastocytoma mutant). Cells were expanded in vitro and characterized and assayed for activity against the relevant tumor in vivo. Clone cells were CD4-, CD8+ T lymphocytes, as determined by fluorescence activated cell sorting analysis and were specifically cytotoxic against P815 tumor cells in vitro, as shown in chromium 51 release assays. These cells require both antigen and interleukin 2 to proliferate; neither alone is sufficient, even with the addition of interleukin 1. In an experimental P815 liver metastasis model, the adoptive transfer of GD11 or GD11.17 clone cells and injection of recombinant interleukin 2 (7500 U intraperitoneally) 3 days after infusion of tumor cells reduced the number of tumor nodules, while the adoptive transfer of lymphokine-activated killer cells was ineffective.

Animals

Toward fully automatic estimation of in vivo 31P spectra.

Fitting a model to an experimental spectrum is a difficult nonlinear estimation problem. The solution presented here is to start an iterative search procedure sufficiently close to the optimal model parameter set. This is achieved by providing tissue-dependent a priori peak information and by a novel correlation method to get good primary estimates of the resonance and phase offset parameters. The resulting estimation procedure is fully automatic and has proven to be robust for 31P data.

Brain

[In vivo 31P-cardiac magnetic resonance spectroscopy: methods and the first clinical results].

31P-magnetic resonance (MR) spectra of the heart can be obtained from well-defined myocardial regions by combined MR imaging and variable selected volumes for spectroscopy. 31P-spectra of 33 volunteers and of 43 patients with dilated and hypertrophic cardiomyopathy and with coronary artery disease were quantified using a curve-fitting routine. To optimize our technique, we recorded unsaturated and partially saturated spectra in several volunteers. Relative peak areas and signal-to-noise ratios showed significant changes with varying pulse repetition times. Saturation factors were applied to correct spectra from volunteers and patients for the effects of partial saturation. Under resting conditions, peak areas of volunteers and patients from the various groups were statistically indistinct.

Adult

Capillary and venous blood glucose measurements using a direct glucose-sensing meter.

The aim of the study was to evaluate the precision and accuracy of the ExacTech home blood glucose meter when used with either capillary or venous blood and to compare this with a reference whole blood glucose assay. Non-fasting glucose measurements were used since a validation study showed no capillary-venous differences between fasting and post-prandial states. In a cross-sectional study, blood was taken from 182 patients and measured in duplicate on three batches of strips. Altogether we analysed 1089 readings. The regression of the data from capillary blood samples (meter vs reference method) had a correlation coefficient, of 0.93, and a mean bias of 0.2 mmol l-1. The corrected 90% confidence interval was +/- 1.5 mmol l-1 overall, and +/- 0.9 mmol l-1 for readings under 7.0 mmol l-1. Regression of the data from venous blood samples (meter vs reference method) had a correlation coefficient of 0.93 and a slope of x 1.1. The corrected 90% confidence interval was +/- 1.7 mmol l-1. Thus venous blood may be used even though the meter is calibrated for capillary samples but the value must be corrected by dividing by 1.1. Error-grid analysis showed that day-to-day clinical decisions could be made on the basis of ExacTech readings, although a diagnosis of borderline diabetes may not be possible.

Blood Glucose

Effect of hypothyroidism on phosphorus metabolism in muscle and liver: in vivo P-31 MR spectroscopy study.

Hypothyroidism is known to affect nearly every organ and organ system of the human body. The goal of the present study was to gain insight into the phosphorus metabolism and bioenergetic function of striated (calf) muscle and liver in patients with hypothyroidism before and after thyroid hormone treatment. With an ISIS (image-selected in vivo spectroscopy) magnetic resonance (MR) technique for volume selection, phosphorus-31 metabolism of the calf muscle in 10 patients and of the liver in seven patients with severe hypothyroidism was studied before and after treatment. In addition, spectra from the calf muscle and liver were obtained in 10 healthy volunteers. Relative to those from the healthy subjects, the P-31 MR spectra from patients with hypothyroidism showed a significantly diminished phosphocreatine/inorganic phosphate ratio (P less than .01). After thyroid hormone substitution therapy, this ratio returned to normal values within several weeks. No statistically significant changes in the spectra of liver tissue could be detected. The results support the theory that hypothyroidism induces a hormone-dependent, fully reversible impairment of the energy metabolism of striated muscle. Changes in liver metabolism observed with biochemical methods are apparently not detectable with state-of-the-art P-31 MR spectroscopy.

Adult