PubMed Health⌕ Search

Biomedical subjects

G N Duda

Publications and source records attributed to G N Duda.

At least 19 recordsLinked to original sources

Digital image correlation: a technique for determining local mechanical conditions within early bone callus.

Local mechanical conditions are known to play a role during the regeneration of musculoskeletal tissues, and histomorphometrical investigations of the time course of healing have enabled specific conclusions regarding the mechanosensitivity of tissue differentiation. However, the mechanism for this influence is not clearly understood. In order to extend this analysis, it is essential to link local histological understanding with direct characterisation of the local mechanical environment. Digital image correlation (DIC) is a computer-based image analysis technique that enables the non-contact measurement of strains on material surfaces and is finding application in many areas of biomechanics. Here we report a DIC technique to investigate the local distribution of mechanical strain within regenerating soft tissue sections. We provide exemplary data from analysis of a section of sheep bone callus. An assessment of displacement measurement accuracy gave an RMS error of 4.2 microm, corresponding to an estimated strain error of 1.4%. The sections showed concentrations of up to four times the applied strain and comparison of the strain patterns with histological analysis confirmed that these concentrations reflected boundaries between hard and soft callus.

Animals↗

Altered cartilage mechanics and histology in knee osteoarthritis: relation to clinical assessment (ICRS Grade).

OBJECTIVE: Substantial changes in articular cartilage composition and mechanical properties occur during the development of osteoarthritis (OA). While softening in the initial stage is reported and sometimes used as an indicator of early OA, there is a lack of data relating the macroscopic appearance of cartilage to its mechanical and histological properties in all stages of degeneration. Knowledge about the mechanical quality of the tissue is important for diagnostic reasons and the understanding of the development of OA. DESIGN: The cartilage areas of 21 osteoarthritic human cadaver tibia plateaus were classified using the International Cartilage Repair Society (ICRS) system. A material testing device determined the Young's modulus of the cartilage by unconfined compression. Histological analysis used haematoxylin and eosin staining and Safranin-O staining for the evaluation of the Mankin score. RESULTS: A correlation between increasing ICRS Grade and stiffness reduction was found (R2=0.69). Stiffness values were for ICRS Grades 1, 2 and 3: E1=0.50+/-0.14 MPa, E2=0.37+/-0.13 MPa and E3=0.28+/-0.12 MPa, respectively. The histological evaluation confirmed the ICRS classification (R2=0.74). A moderate correlation between Mankin score and cartilage stiffness was observed (R2=0.47). CONCLUSIONS: The results indicate a relation between structural, mechanical and histological changes in all stages of the degeneration. With increasing ICRS Grade the cartilage stiffness, which is primarily influenced by the integrity of the extracellular matrix, decreases. Therefore, methods of stiffness determination such as indentation may be used to characterize cartilage in all stages of OA. However, the data suggest that differentiating between healthy cartilage and ICRS Grade 1 may be difficult using mechanical testing alone.

Aged↗

Do serological tissue turnover markers represent callus formation during fracture healing?

Serological parameters of bone and fibrous tissue turnover were demonstrated to monitor the course of fracture healing. The aim of this study was to evaluate the correlation between the serological parameter levels during fracture healing and callus development in a standardised ovine model of fracture healing. Two years old female sheep received a standardised 3 mm tibial bone defect stabilised by an external fixator. The serological levels of the C-terminal propeptide of procollagen type I (PICP), bone specific alkaline phosphatase (bALP), total alkaline phosphatase (tALP), osteocalcin, tartrate-resistant acid phosphatase (TRAP), calcium, phosphate and the N-terminal peptide of procollagen type III (PIIINP) were observed over a 9-week healing period. The course of fracture healing was monitored radiographically, and the callus composition was evaluated histologically at 2, 3, 6 and 9 weeks post-surgery. The serological results were compared with an untreated control group. Additionally, the maximum values during healing were compared with juvenile values to gauge the level of the serological response. The histological and radiographical results demonstrated callus formation without complications. All serological parameters showed broad inter-individual variations, and the response to the standardised fracture scenario was strongly individual. Maximum values during fracture healing did not reach the juvenile levels. The fractured as well as the control animals showed significant changes in the parameter levels. No correlations were observed between the histological course of healing and the course of bone formation markers whilst the TRAP level was reduced during bony callus formation. The PIIINP level increased when the amount of soft callus tissue decreased during healing. The observed bone formation markers were not suitable as general markers to detect the course of fracture healing, whilst PIIINP was able to reflect soft callus degradation.

Acid Phosphatase↗

Poly(D,L-lactide) coating is capable of enhancing osseous integration of Schanz screws in the absence of infection.

Pin loosening is a major complication in external fixation. Biological and mechanical conditions play an important role in the maintenance and enhancement of the implant-bone interface in fracture fixation. It is thought that biodegradable coatings may be capable of preventing pin track infection and pin loosening. The goal of this study was therefore to analyze the influence of a biodegradeable coating on the osseous integration of Schanz' screws during fracture treatment. Standardized osteotomies (3-mm fracture gap) of the right tibiae were performed on 16 sheep and stabilized by an AO mono-lateral external fixator. Additional, mechanically less loaded Schanz' screws were also mounted. All screws were randomly coated with biodegradable poly(D,L-lactide). The sheep were sacrificed after 9 weeks. All screws were removed and rolled on blood agar plates for microbiological analysis. Histological sections of the pin tracks were histochemically and morphometrically analyzed. Clinically, no signs of severe infection were visible. Microbiological analysis revealed 14.8% colonization by Staphylococcus aureus in the coated and 29% in the uncoated screws. Histomorphometry of the bone surrounding the Schanz' screws revealed that significantly more osseous integration had occurred on poly(D,L-lactide)-coated screws in the absence of bacterial colonization. Significantly more bone remodeling and a higher osteoclastic activity was seen near the screw-bone interface in the uncoated screw group. Up to a threefold increase in new bone formation and more severe remodeling was observed around the screw entry compared to the pin exit in all groups. Loaded screws showed significantly more callus formation around the exit sites than their less loaded counterparts. In the present study, poly(D,L-lactide) coating of Schanz' screws was found to enhance osseous integration in the absence of bacterial colonization in sheep by causing less cortical remodeling and less osteoclastic activity in the cortices compared to uncoated screws. Additionally, the coating appeared to reduce the instances of pin track infections. Mechanical loading showed an adverse effect on bone formation and remodeling. It has been shown that both biological and mechanical factors play an important role in the maintenance of osseous integrity of the pin-bone interface. Poly(D,L-lactide) coating of Schanz' screws does not prevent osseous destruction and severe bacterial colonization along the pin tracts, but can improve osseous integration of Schanz' screws in the absence of infection.

Agar↗

Gait evaluation: a tool to monitor bone healing?

BACKGROUND: Current clinical methods for monitoring fracture healing are often invasive and inaccurate. This paper evaluates the use of a pressure sensitive platform to improve monitoring. METHODS: Standardised 3 mm diaphyseal bone defects were created in the right tibia of 64 female sheep and stabilised with either a rigid monolateral external fixator or a more flexible variant. Over a nine week healing period gait parameters were measured using a pressure sensitive platform and interfragmentary movements at the fracture site were monitored. Frequency spectra were calculated for the ground reaction forces. The tibiae were tested biomechanically after sacrifice and callus sections were analysed histomorphometrically. FINDINGS: All animals unloaded the operated and overloaded the contralateral hindlimb. Callus mineralisation and stiffness, as well as limb loading increased during healing whilst interfragmentary movements were reduced. Larger interfragmentary movements resulted in a slower fracture healing rate as documented histologically and biomechanically. Frequency analysis showed upto 14 dB loss of power at frequencies associated with bone mechanotransduction at four weeks postoperatively, reducing to a 3 dB loss at nine weeks. INTERPRETATION: Gait analysis is a valuable tool for monitoring the course of fracture healing. Different fixation stiffnesses caused different initial interfragmentary movements leading to different healing rates. Ground reaction forces were strongly related to the course of callus mineralisation and thus directly reflected the recovery of stiffness at the fracture site. Reduced levels of loading frequencies that may affect bone healing persist to nine weeks postoperatively.

Analysis of Variance↗

Determination of muscle loading at the hip joint for use in pre-clinical testing.

The stability of joint endoprostheses depends on the loading conditions to which the implant-bone complex is exposed. Due to a lack of appropriate muscle force data, less complex loading conditions tend to be considered in vitro. The goal of this study was to develop a load profile that better simulates the in vivo loading conditions of a "typical" total hip replacement patient and considers the interdependence of muscle and joint forces. The development of the load profile was based on a computer model of the lower extremities that has been validated against in vivo data. This model was simplified by grouping functionally similar hip muscles. Muscle and joint contact forces were computed for an average data set of up to four patients throughout walking and stair climbing. The calculated hip contact forces were compared to the average of the in vivo measured forces. The final derived load profile included the forces of up to four muscles at the instances of maximum in vivo hip joint loading during both walking and stair climbing. The hip contact forces differed by less than 10% from the peak in vivo value for a "typical" patient. The derived load profile presented here is the first that is based on validated musculoskeletal analyses and seems achievable in an in vitro test set-up. It should therefore form the basis for further standardisation of pre-clinical testing by providing a more realistic approximation of physiological loading conditions.

Computer Simulation↗

The course of bone healing is influenced by the initial shear fixation stability.

Fracture healing is influenced by fixation stability and experimental evidence suggests that the initial mechanical conditions may determine the healing outcome. We hypothesised that mechanical conditions influence not only the healing outcome, but also the early phase of fracture healing. Additionally, it was hypothesised that decreased fixation stability characterised by an increased shear interfragmentary movement results in a delay in healing. Sixty-four sheep underwent a mid-shaft tibial osteotomy which was treated with either a rigid or a semi-rigid external fixator. Animals were sacrificed at 2, 3, 6 and 9 weeks postoperatively and the fracture callus was analysed using radiological, biomechanical and histological techniques. The tibia treated with semi-rigid fixation showed inferior callus stiffness and quality after 6 weeks. At 9 weeks, the calluses were no longer distinguishable in their mechanical competence. The calluses at 9 weeks produced under rigid fixation were smaller and consisted of a reduced fibrous tissue component. These results demonstrate that the callus formation over the course of healing differed both morphologically and in the rate of development. In this study, we provide evidence that the course of healing is influenced by the initial fixation stability. The semi-rigid fixator did not result in delayed healing, but a less optimal healing path was taken. An upper limit of stability required for successful healing remains unknown, however a limit by which healing is less optimal has been determined.

Animals↗

Cementless stem fixation and primary stability under physiological-like loads in vitro.

Primary stability and in consequence osteointegration are commonly related to the stem anchorage but also to the complex musculoskeletal loading of the hip region. This study investigated the influence of metaphyseal and meta-diaphyseal anchorage on the primary stability of cementless stems under physiological-like loading in vitro. Metaphyseal and meta-diaphyseal anchoring stems (n=6 each) were implanted into composite femora. Musculoskeletal loads, validated by in vivo data (peak joint force 2348 N), were applied using a mechanical set-up. Interface movements were recorded by seven displacement transducers and primary stability was compared. Both stems exhibited similar movement patterns and principally moved distally with a retroversional twist. Although elastic movements were comparable, the metaphyseal stem exhibited higher plastic deformations than the meta-diaphyseal stem, particularly for the metaphyseal, medio-lateral and antero-posterior components. Under physiological-like loading, the metaphyseal stem allowed higher interface movements and tended to initially migrate faster than the meta-diaphyseal stem and then stabilized. Elastic movements were comparable and seemed to be less influenced by the anchoring concept than by the mechanical properties of the bone. The analyses emphasize the importance of metaphyseal bone in proximal anchorage and the necessity of an accurate canal preparation to prevent excessive initial migration.

Arthroplasty, Replacement, Hip↗

Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae.

BACKGROUND: Large interfragmentary movements may delay bone-healing. The hypothesis of the present study was that a reduction of interfragmentary movements, especially of torsional rotation and bending angles, would support the healing process and lead to improved healing following unreamed tibial nailing. The objective of this study was to investigate healing of an unstable tibial osteotomy site following stabilization with unreamed nailing with a modified tibial device that had angle stable holes for the locking bolts. We compared those findings with healing after stabilization of such sites with standard unreamed tibial nailing. The duration of the study period was nine weeks. METHODS: The site of a standardized displaced osteotomy (3-mm gap) in twelve ovine tibiae was stabilized with unreamed tibial nailing: six animals were treated with a modified nail that had angle stable holes for the locking bolts, and six were treated with standard unreamed tibial nailing. In vivo gait analysis with optical measurements of interfragmentary movements and simultaneous measurements of ground reaction parameters were performed three days after the operation and once weekly afterward. After the animals were killed at nine weeks, the treated and contralateral tibiae were explanted, the implants were removed, and radiographs were made and evaluated for bridged cortices. Each pair of tibiae was also mechanically tested until torsional failure, after which the whole callus region was subjected to histological and histomorphometric analysis. RESULTS: Throughout the examination period, the interfragmentary movements in all directions were significantly smaller in the group treated with the angle stable tibial nail than they were in the group treated with standard unreamed tibial nailing. The limbs treated with the angle stable tibial nails returned to almost full weight-bearing during the period of the investigation, whereas those treated with standard nailing did not. Histomorphometric analysis, radiographic data, and mechanical testing showed superior bone-healing following treatment with the angle stable tibial nail. CONCLUSIONS: Use of an angle stable tibial nail may help to reduce interfragmentary movements in vivo and thus lead to superior bone-healing compared with that following standard unreamed tibial nailing.

Analysis of Variance↗

Are bone turnover markers capable of predicting callus consolidation during bone healing?

The aim of this study was to determine the ability of the following bone turnover markers to monitor the course of callus consolidation during bone healing: Carboxy-terminal propeptide of procollagen type I (PICP), skeletal alkaline phosphatase (sALP), and amino-terminal propeptide of type III procollagen (PIlINP). Since interfragmentary movements have been proven to possess the ability to document the progression of bone healing in experimental studies, correlations between bone turnover markers and interfragmentary movements in vivo were investigated. Therefore, two different types of osteosyntheses representing different mechanical situations at the fracture site were compared in an ovine osteotomy model. Blood samples were taken preoperatively and postoperatively in weekly intervals over a nine-week healing period. At the same intervals, interfragmentary movements were measured in all sheep. After nine weeks, animals were sacrificed and the tibiae were evaluated both mechanically and histologically. Wide interindividual ranges were observed for all bone turnover markers. The systemic PICP level did not increase with callus consolidation. The bone-healing model seemed to influence the systemic level of PIIINP and sALP but no general correlation between bone turnover markers and interfragmentary movements could be detected. No differences between the different types of osteosyntheses and thus the different mechanical situations were observed. All analyzed markers failed as general predictors for the course of callus consolidation during bone healing.

Alkaline Phosphatase↗

Comparison of unreamed nailing and external fixation of tibial diastases--mechanical conditions during healing and biological outcome.

Locked intramedullary nailing and external fixation are alternatives for the stabilization of tibial shaft fractures. The goal of this study was to determine to what extent the mechanical conditions at the fracture site influence the healing process after unreamed tibial nailing compared to external fixation. A standardized tibial diastasis was stabilized with either a locked unreamed tibial nail or a monolateral fixator in a sheep model. Interfragmentary movements and ground reaction parameters were monitored in vivo throughout the healing period. After sacrifice, the tibiae were examined mechanically and histologically. Bending angles and axial torsion at the fracture site were larger in the nail group within the first five weeks post-operatively. Unlike the fixator group, the operated limb in the nail group did not return to full weight bearing during the treatment period. Mechanical and histomorphometrical observations showed significantly inferior bone healing in the nail group compared to the fixator group. In this study, unreamed nailing of a tibial diastasis did not provide rotational stability of the osteosynthesis and resulted in a significant delay in bone healing.

Animals↗

Proximal humeral fractures: how stiff should an implant be? A comparative mechanical study with new implants in human specimens.

BACKGROUND: The objective of this study was to determine the in vitro characteristics of the clinically used and newly developed implants for the stabilization of proximal humeral fractures under static and cyclic loading. The goal was to optimize implant stiffness for fracture stabilization even in weak bone stock. METHODS: In a laboratory study using 35 fresh human humeri, the specimens were randomized into 5 groups, which included the clinically used humerus T-plate (HTP), the cross-screw osteosynthesis (CSO), the unreamed proximal humerus nail with spiral blade (UHN), the recently developed Synclaw Proximal Humerus Nail (Synclaw PHN) and the angle-stable Locking Compression Plate Proximal Humerus (LCP-PH). The implant stiffness was determined for three clinically relevant load cases: axial compression, torsion and varus bending. In addition, a cyclic varus-bending test was performed to determine the implant properties under cyclic loading. RESULTS: In contrast to a rather elastic and minimally invasive implant(LCP-PH), the conventionally designed ones (Synclaw PHN, CSO, HTP, UHN) showed rather high stiffness values under static loading. In cyclic loading, a strong decrease in stiffness ( p<0.05) was found for the rigid implants HTP and UHN. In comparison with the other implants, only the elastic implant (LCP-PH) showed a significantly lower load reduction in a weak bone stock (17+/-6.2%). CONCLUSION: The high initial stiffness of rigid implants led to an early loosening and failure of the implant-bone interface under cyclic loading. Implants with low stiffness and elastic characteristics, however, appear to minimize the peak stresses at the bone-implant interface, making them particularly suitable for fracture fixation in osteoporotic bone.

Adult↗

[Mechanical borderline indications in the treatment of unreamed tibial nailing].

The extended usage of unreamed tibial nailing resulted in reports of an increased rate of complications, especially for the distal portion of the tibia. The goal was to gain a thorough understanding of the load-sharing mechanism between unreamed nail and bone in a fractured tibia, and to identify borderline indications due to biomechanical factors. In finite element analyses of a human tibia, horizontal defects were modeled using unreamed nailing for five different fracture locations, including proximal and distal borderline indications for this treatment method. The findings of this study show that with all muscle and joint contact forces included, nailing leads to considerable unloading of the interlocked bone segments. Unreamed nailing of the distal defect results in an extremely low axial and high shear strain between the fragments. Apart from biological reasons, clinical problems reported for distal fractures may be due to the less favorable mechanical conditions in unreamed nailing. From a biomechanical perspective, the treatment of distal tibial shaft fractures with unreamed nailing without additional fragment contact or without stabilizing the fibula should be carefully reconsidered.

Biomechanical Phenomena↗

[Age- and gender-related distribution of bone mineral density and mechanical properties of the proximal humerus].

PURPOSE: To evaluate age- and gender-related mechanical properties and bone mineral density (BMD) of the proximal humerus at different levels and regions. MATERIALS AND METHODS: Mechanical indentation testing, DXA, QCT, pQCT and the radiogrammetry (Cortical Index, CI) were carried out in 70 freshly harvested humeri from 46 human cadavers (23 females, 23-males; median age 70.5 years). RESULTS: In the female group, a high correlation between age and BMD was found (rho = 0.62 to -0.70, p < 0.01) with statistically significant differences between specimens of patients 69 years or younger, and 70 years or older (p < 0.05). In the group of female specimens of age 70 years or older, BMD values were found to be significantly lower compared to their male counterparts (p < 0.05). Regardless of the specimen's age, the highest BMD and bone strength were found in the proximal aspect and in the medial and dorsal regions of the proximal humerus. CONCLUSION: These findings provide an insight into the fracture mechanism of the proximal humerus and should be the basis for designing structure-oriented implants with improved implant-bone stability in osteoporotic patients.

Absorptiometry, Photon↗

[Physiological loading of the mandibular osteosynthesis: development of an improved mandibular load simulator].

Loading conditions physiologically approximating those acting on the normal masticatory system were incorporated into a new mandibular load simulator. Separate tension wires attached to each ramus of the mandible simulated the resultant force vectors of the masticatory musculature. The muscle insertion points were chosen in accordance with the anatomical situation, and the maximum in vivo forces acting on the joint. In a first application, the stability of a 2.4 mm LC-WDCP was compared with that of a 2.7 mm EDCP in plastic mandible models. It was found that under largely physiological loading, the 2.4 mm LC-EDCP exerted a stabilizing effect similar to that of a 2.7 mm EDCP. Although of smaller dimensions, the 2.4 mm LC-EDCP appears to enable an osteosynthesis of similar stability in the treatment of fractures of the mandibular angle.

Biomechanical Phenomena↗

Mechanical boundary conditions of fracture healing: borderline indications in the treatment of unreamed tibial nailing.

Unreamed nailing favors biology at the expense of the achievable mechanical stability. It is therefore of interest to define the limits of the clinical indications for this method. The extended usage of unreamed tibial nailing resulted in reports of an increased rate of complications, especially for the distal portion of the tibia. The goals of this work were to gain a thorough understanding of the load-sharing mechanism between unreamed nail and bone in a fractured tibia, to identify the mechanical reasons for the unfavorable clinical results, and to identify borderline indications due to biomechanical factors. In a three-dimensional finite element model of a human tibia, horizontal defects were stabilized by means of unreamed nailing for five different fracture locations, including proximal and distal borderline indications for this treatment method. The loading of the bone, the loading of the implant and the inter-fragmentary strains were computed. The findings of this study show that with all muscle and joint contact forces included, nailing leads to considerable unloading of the interlocked bone segments. Unreamed nailing of the distal defect results in an extremely low axial and high shear strain between the fragments. The results suggest that mechanical conditions are advantageous to unreamed nailing of proximal and mid-diaphyseal defects. Apart from biological reasons, clinical problems reported for distal fractures may be due to the less favorable mechanical conditions in unreamed nailing. From a biomechanical perspective, the treatment of distal tibial shaft fractures by means of unreamed nailing without additional fragment contact or without stabilizing the fibula should be carefully reconsidered.

Biomechanical Phenomena↗

Musculo-skeletal loading conditions at the hip during walking and stair climbing.

Musculo-skeletal loading plays an important role in the primary stability of joint replacements and in the biological processes involved in fracture healing. However, current knowledge of musculo-skeletal loading is still limited. In the past, a number of musculo-skeletal models have been developed to estimate loading conditions at the hip. So far, a cycle-to-cycle validation of predicted musculo-skeletal loading by in vivo measurements has not been possible. The aim of this study was to determine the musculo-skeletal loading conditions during walking and climbing stairs for a number of patients and compare these findings to in vivo data. Following total hip arthroplasty, four patients underwent gait analysis during walking and stair climbing. An instrumented femoral prosthesis enabled simultaneous measurement of in vivo hip contact forces. On the basis of CT and X-ray data, individual musculo-skeletal models of the lower extremity were developed for each patient. Muscle and joint contact forces were calculated using an optimization algorithm. The calculated peak hip contact forces both over- and under-estimated the measured forces. They differed by a mean of 12% during walking and 14% during stair climbing. For the first time, a cycle-to-cycle validation of predicted musculo-skeletal loading was possible for walking and climbing stairs in several patients. In all cases, the comparison of in vivo measured and calculated hip contact forces showed good agreement.Thus, the authors consider the presented approach as a useful means to determine valid conditions for the analysis of prosthesis loading, bone modeling or remodeling processes around implants and fracture stability following internal fixation.

Aged↗

Hip contact forces and gait patterns from routine activities.

In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous analyses of gait patterns and ground reaction forces were performed in four patients during the most frequent activities of daily living. From the individual data sets an average was calculated. The paper focuses on the loading of the femoral implant component but complete data are additionally stored on an associated compact disc. It contains complete gait and hip contact force data as well as calculated muscle activities during walking and stair climbing and the frequencies of daily activities observed in hip patients. The mechanical loading and function of the hip joint and proximal femur is thereby completely documented. The average patient loaded his hip joint with 238% BW (percent of body weight) when walking at about 4 km/h and with slightly less when standing on one leg. This is below the levels previously reported for two other patients (Bergmann et al., Clinical Biomechanics 26 (1993) 969-990). When climbing upstairs the joint contact force is 251% BW which is less than 260% BW when going downstairs. Inwards torsion of the implant is probably critical for the stem fixation. On average it is 23% larger when going upstairs than during normal level walking. The inter- and intra-individual variations during stair climbing are large and the highest torque values are 83% larger than during normal walking. Because the hip joint loading during all other common activities of most hip patients are comparably small (except during stumbling), implants should mainly be tested with loading conditions that mimic walking and stair climbing.

Activities of Daily Living↗