PubMed Health⌕ Search

Biomedical subjects

G Orton

Publications and source records attributed to G Orton.

3 recordsLinked to original sources

Earth-Based Observations of the Galileo Probe Entry Site

Earth-based observations of Jupiter indicate that the Galileo probe probably entered Jupiter's atmosphere just inside a region that has less cloud cover and drier conditions than more than 99 percent of the rest of the planet. The visual appearance of the clouds at the site was generally dark at longer wavelengths. The tropospheric and stratospheric temperature fields have a strong longitudinal wave structure that is expected to manifest itself in the vertical temperature profile.

Journal Article↗

Collision of comet Shoemaker-Levy 9 with Jupiter observed by the NASA infrared telescope facility.

The National Aeronautics and Space Administration (NASA) Infrared Telescope Facility was used to investigate the collision of comet Shoemaker-Levy 9 with Jupiter from 12 July to 7 August 1994. Strong thermal infrared emission lasting several minutes was observed after the impacts of fragments C, G, and R. All impacts warmed the stratosphere and some the troposphere up to several degrees. The abundance of stratospheric ammonia increased by more than 50 times. Impact-related particles extended up to a level where the atmospheric pressure measured several millibars. The north polar near-infrared aurora brightened by nearly a factor of 5 a week after the impacts.

Ammonia↗

Monitoring dental sterilizers' effectiveness using biological indicators.

The purpose of this study was to evaluate the effectiveness of dental office sterilizers as measured by their ability to kill bacterial spores present on biological indicator strips. The biological indicators used in this study contained two different spores, Bacillus stearothermophilus and Bacillus subtilis (Spordi, AMSCO/Medical Products). Ten spore test strips were sent to 87 dental offices; 51 sterilizers were tested. Office personnel were instructed to place four strips in the center of a normal sterilization load and process the load. The procedure was repeated on a second day. The processed strips, along with two unprocessed control strips, were returned by mail for laboratory culturing. The results indicated the overall failure rate (positive test) of sterlizers tested for both days was 51% at the culturing temperature of 37 degrees C and 33.3% at 55 degrees C. McNemar's test indicated a significant difference (p less than .03) in sterilization failures associated with the type and number of microorganisms present on the test strips. This study also showed that the more times a sterilizer was tested, the more likely a failure would occur. Overall, an alarming number of sterilizers (64.7%) were not effective in killing all the spores present on the indicator strips. When office personnel were given information for improving sterilizer performance, there was a noticeable reduction in sterilization failures following retesting.

Evaluation Studies as Topic↗