PubMed HealthSearch

Biomedical subjects

G P Pizzuti

Publications and source records attributed to G P Pizzuti.

14 recordsLinked to original sources

Finger tremor and the central nervous system.

It is well known that normal physiological tremor of the fingers and alpha rhythm in the EEG, may share a common frequency band in the region of 10 Hz; that these two characteristics may be in some way related as a function of their frequencies, is a hypothesis which needs to be tested, as one element in establishing the physiology of physiological tremor. Bilateral occipital EEGs and simultaneous measurements of acceleration from the terminal phalanx of the middle finger of both hands were recorded from eight subjects. The data were analysed to produce power spectral densities and coherence functions, the latter being used to reveal the presence or absence of frequency elements common to both signals. No evidence was found that would support a hypothesis that the two characteristics were in any way frequency related, from which it can be inferred that the tremor is not under central control. In addition, tremor of the right and left hands does not show a synchronous relationship.

Brain

The serum lipoprotein pattern of water buffalo (Bubalus bubalis).

1. The serum lipoprotein pattern of water buffalo was studied by means of electrophoresis and the lipoproteins were isolated by ultracentrifugation on the basis of their hydrated density. 2. High density lipoproteins (HDL) showed a higher level of cholesterol than did the other lipoproteins. Moreover, the level of phospholipids was higher in HDL than in very low density lipoproteins (VLDL). 3. The buffalo B100 apoprotein was similar to that of man and rat. Three apoproteins similar to human apo E, apo AI and AII were found in buffalo HDL, buffalo VLDL contained essentially apo B protein.

Animals

Digital sampling rate and ECG analysis.

The influence of sampling rate on the accuracy of measurements of various ECG parameters has been studied. Statistical analysis showed no significant difference between results obtained at sampling rates of 500 and 250 samples s-1. Recordings made at 125 samples s-1, however, showed significant reductions in peak amplitude values. Some interval measurements also varied significantly to both larger and smaller values. Other intervals did not seem to be affected significantly. It is concluded that a sampling rate of 125 samples s-1 could be used in particular conditions when only the measurement of certain intervals is required.

Biomedical Engineering