Workplace measurement of respirator effects using respiratory inductive plethysmography.

A useful system to study the cardiopulmonary effects of respirators in the workplace would be reliable, portable, and lightweight and would not encumber the nose or mouth or require modification to the respirator. Twenty men using such a system (which measured ventilatory parameters by respiratory inductive plethysmography [RIP]) were studied. The subjects all performed their usual jobs which involved some work with and some without a respirator. Twelve subjects used airline respirators and eight used air-purifying respirators. The RIP equipment measurements included respiratory frequency, tidal volume (VT), minute ventilation (V), and heart rate (HR). The RIP data from 20 other subjects was lost because of equipment malfunction, primarily lead separation in those whose jobs involved climbing around large workpieces. In general, the workers' cardiopulmonary parameters increased during respirator wear, probably because of a combination of factors, including the increased exercise of most respirator-requiring tasks and the weight and heat stress associated with the respirator and protective clothing. When the ventilatory parameters with and without a respirator were compared at the same heart rates, no significant differences were noted in VT for the entire group. Respiratory frequency, however, and V increased with respirator wear. The effects of respirators alone were found to be commonly confounded in the workplace by changes in protective clothing, exercise requirements, and ambient heat stress. Further improvements in the portable RIP system are needed before it can be accepted as a reliable ventilatory measurement device in the workplace.

Adult↗

The use of inductive plethysmography in the study of the ventilatory effects of respirator wear.

The authors recently developed an ambulatory system, in which a self-contained respiratory inductive plethysmograph (RIP) was used, to measure noninvasively the volume and time components of breathing. Since it does not use nasal or oral devices, such a system is particularly suitable for use in studying the effects of respiratory protective masks on respiratory parameters. In order to validate this portable system, 22 healthy subjects were exercised on a treadmill; RIP and pneumotachographic minute ventilation measurements were compared. A short, graded submaximal exercise protocol was run 3 times by each subject under each of the following conditions: no oral mouthpiece; oral mouthpiece with pneumotachograph; and wearing an industrial protective mask (half facepiece, twin cartridge). Chest and abdominal RIP signals, a time signal and either a pneumotachograph or heart-rate signal were recorded on a small cassette recorder worn at the belt. The data tapes were later edited and analyzed by computer. Data from 5 subjects were excluded because of equipment malfunction. The average error in RIP-measured ventilation compared to values simultaneously measured by a pneumotachograph in the 17 remaining subjects over all exercise levels was -3.16%. Marked variability (SD = 11.26%), however, was found in individuals at different exercise levels and especially between subjects. Use of a respirator was associated with a decreased respiratory frequency, an increased tidal volume and minute ventilation, and an unchanged heart rate. At present, the portable RIP system has substantial variability that limits its ability to measure ventilation accurately.

Humans↗