Mechanical cardiac support 2000: current applications and future trial design. June 15-16, 2000 Bethesda, Maryland.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to G Pantalos.
Explore the source record for details and available documents.
A comparative study of flow dynamics past biomer trileaflet valves and a pericardial bioprosthetic valve under steady and physiological pulsatile flow conditions in vitro is reported in this paper. The velocity profiles and the turbulent shear stresses distal to the valves were measured using laser Doppler anemometry. The authors' results showed that the velocity profiles distal to the trileaflet valves were similar to that measured distal to the pericardial valve. Higher magnitudes of absolute turbulent shear stresses were measured distal to the synthetic valves in comparison to the pericardial valves. However, when the stresses were nondimensionalized with respect to the orifice diameter at the inlet aspect, the stresses were comparable for all of the three valves. With design modifications to increase the orifice diameter at the inlet aspect of the polyurethane valves, the turbulent stresses distal to the valves can be minimized. Such in vitro studies on the flow dynamics past the polyurethane valves can provide information towards design changes to improve the performance characteristics of these valves. Polyurethane valves with flow characteristics comparable to the pericardial valves can be manufactured relatively inexpensively compared to mechanical or tissue valve prosthesis. Hence, the synthetic valves may be a viable alternative for short-term use in total artificial heart devices as a bridge to transplant.
Explore the source record for details and available documents.
Hemodynamic comparison of two polyurethane prosthetic heart valves with a bioprosthetic valve is presented. The valves were incorporated in a pulse duplicator simulating physiologic pulsatile flow, and comparisons between the valves were made on the transvalvular pressure drop, percent regurgitation, valve orifice area, rate of opening and closing as well as the performance index. The results showed that the functional characteristics of the polyurethane valve compared favorably with that of the bioprosthetic valve. The polyurethane valve can be a viable and inexpensive alternative, especially for short-term use in a total artificial heart as a bridge to transplant.
The pulsatile nature of an implanted total artificial heart (TAH) may have several deleterious effects. To define the level of TAH impact, acceleration was measured and compared with that of the natural heart in a series of in vivo and in vitro experiments. In TAH implantations in calves, miniature accelerometers were incorporated onto the housing of a Utah-100 left ventricle. Identical accelerometers were glued to felt pledgets to obtain measurement of radial cardiac acceleration when sewn to the epicardial surface of the natural heart. Measurement of natural and artificial heart acceleration was made both intraoperatively and postoperatively in several animals. Many pumping conditions were also investigated with a similarly instrumented UVAD 85 left ventricle during in vitro testing. The peak natural heart acceleration measured was nearly 2 g both intraoperatively and at rest. Treadmill exercise or epinephrine infusion produced twice the resting peak acceleration value of the natural heart. Artificial heart peak acceleration as great as +/- 100 g was found intraoperatively and postoperatively. Peak TAH acceleration could be reduced by allowing the ventricle to fill fully prior to the start of the next systole, by allowing the ventricle to fully eject prior to the next diastole, or by using a ventricular pressurization waveform that has a smooth contour with a sinusoidal-like profile. The ability to lower TAH acceleration may lead to a reduction in undesirable consequences of TAH implantation.
The anaerobic threshold represents an objective measure of functional capacity and is useful in assessment of pulmonary and cardiovascular dysfunction. This study determined the anaerobic threshold in total artificial heart animals and evaluated the performance of the total artificial heart system. Five animals with total artificial hearts were put under incremental exercise testing after exercise training. The intensity of exercise ranged from 2.0 to 4.5 km/hr, with an increment of 0.5 km/hr every 3 min. The anaerobic threshold was 6.72 +/- 0.84 ml/kg/min as detected by the lactate method, and 6.48 +/- 0.79 by the CO2 method. The value of the anaerobic threshold in total artificial heart animals implies that the performance capacity of a total artificial heart is not sufficient to meet the oxygen requirements of vigorously exercising skeletal muscle. The protocol does not allow for driving parameter changes during exercise, and this situation, combined with the manual mode of the control system used, was inadequate to allow the total artificial heart animals to exercise more vigorously. Using an automatic control mode might be helpful, as well as considering the relationship between indices of oxygen metabolism, such as oxygen delivery, oxygen consumption, and oxygen extraction rate, in the control algorithms in total artificial heart control systems.
Left ventricular assist device (LVAD) pumping has hemodynamic and anatomic influences on right ventricular performance. A total artificial heart (TAH) model was employed to better understand the hemodynamic influence of an LVAD on the failing right ventricle. Biventricular failure was simulated by reducing both ventricular drive pressures of the TAH. After getting hemodynamic data, LVAD pumping in the case of right ventricular failure was simulated by increasing just the left ventricular drive pressure. In the LVAD-simulating condition, cardiac output increased and right atrial pressure decreased significantly (p less than 0.05) compared with the biventricular failure condition, whereas right ventricular function and minute work were the same in these two conditions. Even though changes were accompanied by adaptive increases in pulmonary resistance, substantially lower pulmonary artery and left atrial pressures resulted in the LVAD-simulating condition. From a hemodynamic perspective, these results indicate that an LVAD can increase right ventricular volume work by decreasing right ventricular pressure work, whereas right ventricular net pressure-volume work is unchanged and right ventricular failure is not worsened.
Konstantinov et al, in October, 1991, published a novel way to bridge a patient for heart transplantation. They proposed to cut off both ventricles high under the atrioventricular groove, leaving the atria, aorta, and pulmonary artery and their valves intact and to attach pneumatically driven, valveless pulsating pouches to assist the heart until a donor could be found. The removal of the ventricles just below the atrioventricular groove is called the "high cut"; it, however, destroys the chordae tendineae rendering the mitral and tricuspid valves insufficient. These have to be replaced by tissue inflow valves. We chose to cut off the ventricles at a lower level (the "low cut") to leave the papillary muscles on both sides intact, thereby saving the integrity of the mitral and tricuspid valves. Pulsating pouches were made to fit the heart at this lower level. They can be easily connected to the remaining heart after a specially disigned cuff has been sutured over the ventricular stumps. The pouches were pumped during the systole of the natural heart, but the myocardium may have to be electrically stimulated during systole to prevent undue distension. If the turgor is too weak to prevent distension, a sleeve over the ventricles is provided. To find the best location for these pouches, human cadaver implantations were done and the pre peritoneal cavity was found to be the most suitable. In vitro testing to determine how much flow could be pumped was done by attaching the pouches to fresh pig hearts and connecting them to a double sided mock circulation.(ABSTRACT TRUNCATED AT 250 WORDS)