Follow-up of a respiratory rate modulated pacemaker.

The efficacy of 27 respiration sensitive rate modulated pacemakers (Biorate RDP-3 Biotec) implanted in the left pectoral area was evaluated every 3 months during a mean follow-up period of 29 months (range 10-50 months). Rate modulation function was unchanged other than for three patients in whom the auxiliary leads became displaced. Two implants lost ventricular sensing in this nonprogrammable model. In all but the three patients, Holter monitoring demonstrated pacing rate variation corresponding to daily activity. Stress test duration increased from 8.2 +/- 1.5 minutes (in fixed rate VVI rate) to 12.83 +/- 2.0 minutes (in the VVIR mode) (P less than 0.05). Right arm movement increased the pacing rate by 5 +/- 3 beats/min (NS), while the left arm movement increase was 30 +/- 5 beats/min (P less than 0.05). Mental, arithmetic, and nifedipine tests did not change the rate modulated pacing rate. The system responded to a change in respiratory rate by an increase in stimulation rate. A satisfactory response in sensitivity and velocity was present only with medium-high workloads. Interference with rate modulation occurred with movement of the arm ipsilateral to the implanted pulse generator.

Atrial Fibrillation

Fourier analysis in patients with different pacing modes.

The purpose of this study was to evaluate the usefulness of phase analysis in detecting the altered activation sequence induced by different pacing modes. Radionuclide ventriculography and planar gated blood pool scintigraphy were performed at rest in 56 patients with different pacemakers. This method permitted us to localize the pacemaker impulse site in the right ventricle and its diffusion in the heart. In patients with VVI pacemaker, this technique showed an evident asynchronism of contraction and relaxation of each ventricle and the standard deviation of phase angle (sigma), calculated by computer, is greater during pacing than sinus rhythm for left (LV) and right (RV) ventricles (LV sigma: 17 degrees +/- 4 vs 11 degrees +/- 3, less than 0.001; RV sigma: 31 degrees +/- 7 vs 14 degrees +/- 4, P less than 0.001). In the patients with VVI rate responsive pacemakers, the LV sigma changed from 18.5 +/- 3 under pacing to 11 degrees +/- 3 in sinus rhythm, P less than 0.001, while the RV sigma changed from 30 degrees +/- 8 to 14 degrees +/- 4, P less than 0.001. Instead in the patients with DDD pacemakers, the LV sigma changed from 15.5 degrees +/- 2 under pacing to 11 degrees +/- 3 in sinus rhythm, P less than 0.05, while the RV sigma changed from 29.1 degrees +/- 6 to 14 degrees +/- 4, P less than 0.001.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Pacing, Artificial