Acute metabolic alkalosis in cystic fibrosis: prospective study and review of the literature.

Between January 1993 and April 1994, 5 patients with cystic fibrosis, aged 4-9 months, were admitted to the Department of Pediatrics, University of Berne, Switzerland, with acute, severe metabolic alkalosis (sodium < 133 mmol/l, plasma potassium < 3.5, chloride < 85, bicarbonate > 35.0 mmol/l, blood pH > 7.43). 87 cases of acute metabolic alkalosis complicating cystic fibrosis reported in the literature between 1951 and 1995 were also reviewed. Our cases and those described in the literature demonstrate that acute metabolic alkalosis occurs in patients aged 2 years or less. Anorexia, vomiting, respiratory exacerbation, fever, and body weight loss often precede metabolic alkalosis. Furthermore, metabolic alkalosis is a common initial presentation of cystic fibrosis, suggesting that this diagnosis should be considered in the context of unexplained metabolic alkalosis.

Acute Disease↗

[The evaluation of the physical characteristics of a volumetric computer tomograph].

Spiral or volumetric computed tomography (CT) is a new scanning technique which allows the scanning of body regions with a continuously rotating system based on the slip ring technology; the patient is also moved continuously, synchronously with data acquisition. The physical characteristics of spiral CT image acquisition were compared with those of conventional CT images. The modulation transfer function (MTF) has the same values for medium-resolution filters, but lower values for spiral CT for high-resolution and frequency-enhancement filters. The slice sensitivity profile (SSP) describes the longitudinal image resolution for multiplanar reconstructions and was measured in terms of FWHM of the SSP curve. We obtained, for 10-mm slice thickness, a FWHM = 10.4 mm (conventional CT), versus 10.7 mm (Spiral CT), while, for 5-mm slice thickness, the corresponding values were 5.2 mm (conventional CT) and 5.5 mm (spiral CT). Noise was evaluated simply by measuring the standard deviation of the CT numbers, in a region of interest, of a uniform image and with the power spectrum or Wiener spectrum of the same image. To assess overall image quality and yield, the noise equivalent quanta (NEQ) value was also calculated. The values were a little lower for the spiral technique, particularly with high-resolution and enhancement or convolution filters. Dosimetric evaluation of the computed tomography dose index (CTDI) and of the multiple scan average dose (MSAD) was done using an acquisition protocol for average lung dose, in an anthropomorphic phantom and with TL dosimeters. The MSAD was 6.17 +/- 0.20 cGy for conventional CT and 5.98 +/- 0.23 cGy for Spiral CT, while lung dose was 3.25 +/- 0.12 cGy and 3.01 +/- 0.16 cGy, respectively.

Artifacts↗

Chronic metabolic alkalosis: not uncommon in young children with severe cystic fibrosis.

The acid-base balance of 199 patients with cystic fibrosis, seen from 1987 through 1992 at the Bern Outpatient Clinic, were evaluated. Simple metabolic alkalosis was demonstrated in 16 and mixed metabolic alkalosis and respiratory acidosis in 9 patients. When compared with 10 patients with simple respiratory acidosis and 16 with normal hydrogen ion balance, those with simple metabolic alkalosis were significantly younger. The need for pancreatic enzymes was significantly higher and the relative underweight significantly more severe in patients with either simple or mixed metabolic alkalosis and respiratory acidosis. The results indicate the rather common occurrence of chronic metabolic alkalosis in cystic fibrosis. It is observed in young patients, in patients who need high doses of pancreatic enzymes and in the those with poor nutritional status.

Acidosis, Respiratory↗

[Digital storage phosphor radiography. Doses and image quality].

Digital radiography (DR) based on storage phosphor technology is progressively replacing conventional screen-film system radiographic techniques (CR). However, many questions about image quality and dose reduction are still open. Thus, since DR spatial resolution is always lower than that of high quality screen-film images and image noise is conversely higher, for general radiography examinations especially, the signal-to-noise ratio is always lower with DR than with CR at the same dose level. However, the wide dynamic range, the linear response of storage phosphor detectors and the automatic read-out control of the digital system, enable lower DR X-ray imaging efficiency to be overcome, producing a nearly perfect readout of the image data every time an exposure is made. Moreover, post-processing can make the detection of abnormalities easier. This is why in many ROC clinical accuracy studies DR performed equally or better than CR. Good quality DR images, similar to conventional ones at the same dose levels, are therefore achievable in chest, abdomen, bone and soft-tissues examinations. Dose evaluation protocols are strongly needed in DR since overexposures due to technical mistakes may be overlooked; moreover, doses can be adjusted to the peculiar diagnostic need. The S values shown on any hard-copy image can be used to this purpose, even though it must be pointed out that they do not express the actual mean dose to the detector.

Humans↗

The choice of radiographic film-screen systems: quality evaluation and purchasing specifications drafting. Report on A.I.F.B. Working Group activity.

The comparative evaluation of radiographic screen-film systems presents several problems from both the theoretical and the experimental points of view. From the theoretical point of view the main difficulties are related to the choice of the parameters best suited to express the "overall quality" of a system. This quantity is expressed as a product of image quality index and system sensitivity. As image quality index we assumed the signal-to-noise power ratio: this index depends in an explicit way on contrast, resolution and noise of the system. From the experimental point of view the main problem is that to measure some basic quantities, sophisticated and expensive equipment, like computer-controlled microdensitometers, is generally required. In this paper, we report the Italian Association of Biomedical Physicists Task group suggestions for measuring the basic physical parameters (with particular reference to the use of cost-effective equipment and for purchasing specification drafting). Using synthetic quality indices, the evaluation criteria of radiographic materials are directly derived from the general theory of radiographic image perception.

Physical Phenomena↗

[Digital radiography with phosphorus memory: verification of the centering of the patient in high-energy radiotherapy].

A digital radiographic system using storage phosphor detectors was employed in order to verify radiotherapy treatments with high energy photon beams (60Co-18 MV X-rays). The wide range linearity of the detectors and also the possibility of digital image post-processing allowed portal films to be obtained with sufficient contrast in all treatment techniques, particularly in the case of mantle fields. The use of digital radiography may become an easy and valuable procedure for therapy verification.

Algorithms↗

Description of a simple model for the study of bone calcium metabolism.

A simple model for the study of bone calcium metabolism is proposed. It describes the kinetics of a radioactive tracer in terms of an open single compartment system with an expanding volume for a finite period of time. In addition to the simplicity of the hypotheses introduced, the model is able to give a good description of the biological processes which regulate calcium kinetics. Moreover the functional parameters can be easily calculated, even just graphically. 15 normal subjects and 22 patients affected by various bone diseases were studied. The results were compared with those obtained by using the model proposed by Burkinshaw et al. and the method described by Reeve et al.