PubMed Health⌕ Search

Biomedical subjects

G Penel

Publications and source records attributed to G Penel.

7 recordsLinked to original sources

Composition of bone and apatitic biomaterials as revealed by intravital Raman microspectroscopy.

Microcharacterization of biominerals allows a better understanding of the pathophysiological events that occur in calcified tissues and synthetic biomaterials. Different methods have been extensively used to conduct such investigations. A new model for the intravital study of the composition and structure of membranous bone by Raman microspectroscopy is described. Titanium bone chambers equipped with a fused-silica optical window were implanted transcutaneously in the calvaria of New Zealand rabbits. The implanted optical windows were well tolerated, and spectral acquisitions were performed without any additional invasive procedure. Bone and implanted apatitic biomaterials were analyzed at different times after surgery. All Raman bands were unambiguously identified in the bone and biomaterial spectra. The main PO4 and CO3 Raman bands in bone spectra were consistent with those found in the carbonated apatite spectrum. The major collagen bands were always observed around 1200-1300 (amide III) and 1600-1700 (amide I) delta cm(-1) and, 1400-1470 and 2800-3100 delta cm(-1) (bending and stretching modes of CH groups, respectively). The phenylalanine (Phe) band was identified in all spectra at 1003 delta cm(-1) and overlapped that of the weak HPO4(2-) ion. The CH bands frequently overlapped the lipid bands. However a distinct protein and lipid bands were detected at 2950 and 2852 delta cm(-1), respectively. In bone areas close to blood vessels, the Raman signature of hemoglobin was detected with a characteristic band at 754 delta cm(-1). The changes observed in bone varied as a function of time and location. The composition and structure of all of the biomaterials studied--including those that were resorbable--seemed to remain stable over time and location. We report for the first time the complete intravital study of Raman spectra of bone and calcium phosphate biomaterials over a period of 8 months. This new approach does not require specimen preparation and allows simultaneous observation of mineral and organic bone constituents over time, which therefore should provide insightful information about their relationship.

Animals↗

Raman microspectrometry studies of brushite cement: in vivo evolution in a sheep model.

Calcium phosphate hydraulic cements are promising synthetic bone grafting materials. Brushite-based cements were implanted for 6 and 12 months in the distal condyle of sheep femur, and their in vivo evolution was investigated by Raman microspectrometry. This new technique can probe small volumes in the cubic micrometer range. Its resolution allows a very fine analysis of crystalline changes in calcium phosphate mixtures at the microscopic level. First, Raman spectra of pure brushite, monetite, and beta-tricalcium phosphate (beta-TCP) were recorded, in order to set a data base for the basic components of brushite cements. These spectra show significant differences in the vibration mode v1 for the phosphate ion (988 and 878 cm(-1) for brushite, 988 and 900 cm(-1) for monetite, 968 and 948 cm(-1) for beta-TCP). These differences are strong enough as to allow the qualitative and quantitative analysis of these crystalline phases in the cement. Implanted sheep femur samples were harvested after 24 and 52 weeks post-op, and prepared for Raman analysis in the form of 1-mm-thick sections. Implants at 24 weeks show a core of residual cement isolated from the surrounding bone by fibroconnective tissue. No trace of brushite was detected by micro-Raman analysis in this area, but instead, a mixture of beta-TCP and Type-B carbonated apatite, the latter being very close in composition and structure to the mineral fraction of normal bone in the vicinity of the implant. Implants recovered after 52 weeks show a decrease of the bone/residual cement perimeter, whereas new trabeculations are formed in the implanted zone; the small amounts of residual cement still present are substantially transformed into Type-B carbonated apatite containing small amounts of proteins. In the same area, some beta-TCP particles are also detected showing that, contrary to brushite, the excess beta-TCP originally present in the cement is not completely metabolized. In the implanted zone already converted into trabecular bone, Raman microspectrometry shows the characteristic spectrum of normal bone.

Animals↗

MicroRaman spectral study of the PO4 and CO3 vibrational modes in synthetic and biological apatites.

The carbonate and phosphate vibrational modes of different synthetic and biological carbonated apatites were investigated by Raman microspectroscopy, and compared with those of hydroxyapatite. The nu1 phosphate band at 960 cm-1 shifts slightly due to carbonate substitution in both A and B sites. The spectrum of type A carbonated apatite exhibits two nu1 PO43- bands at 947 and 957 cm-1. No significant change was observed in the nu2 and nu4 phosphate mode regions in any carbonated samples. The nu3 PO43- region seems to be more affected by carbonation: two main bands were observed, as in the hydroxyapatite spectrum, but at lower wave numbers. The phosphate spectra of all biominerals apatite were consistent with type AB carbonated apatite. In the enamel spectrum, bands were observed at 3513 and at 3573 cm-1 presumably due to two different hydroxyl environments. Two different bands due to the carbonate nu1 mode were identified depending on the carbonate substitution site A or B, at 1107 and 1070 cm-1, respectively. Our results, compared with the infrared data already reported, suggest that even low levels of carbonate substitution induce modifications of the hydroxyapatite spectrum. Increasing substitution ratios, however, do not bring about any further alteration. The spectra of dentine and bone showed a strong similarity at a micrometric level. This study demonstrates the existence of acidic phosphate, observable by Raman microspectrometry, in mature biominerals. The HPO42- and CO32- contents increase from enamel to dentine and bone, however, these two phenomena do not seem to be correlated.

Apatites↗

Infrared and Raman microspectrometry study of fluor-fluor-hydroxy and hydroxy-apatite powders.

Visible Raman and infrared microspectrometry studies performed on fluorapatite and hydroxyapatite powders have shown similar results. Small modifications of the nu2 and nu4 PO(3-)4 tetrahedra bending modes are observed. A small frequency shift of the nu1 mode and modifications on the nu3 mode region accompanied with a simplification of the hydroxyapatite and fluorapatite respective spectra from seven to four bands were observed. A broad and weak band which could be attributed to the Ca-F bond is detected at 311 cm(-1) on the Raman fluorapatite spectra. The phosphate vibration modes are little disturbed by fluoride substitution. This could indicate that phosphate groups interact strongly between themselves and weakly with substituted atoms (i.e. hydroxyle and fluoride atoms). Whatever crystallographic model is considered, the number of bands observed is always lower than the number of calculated ones, even for hydroxyapatite, whose symmetry is lower than that of fluorapatite.

Journal Article↗

[Cleaning implantation burs. Observations using scanning electron microscopy].

Drastic aseptic conditions are necessary in implantological treatments. A good sterilizing procedure of the specific instrumentation, like drills, is based on an efficient cleaning. Because of their design, the cleaning of drills is a real challenge. The aim of this investigation is to evaluate two different cleaning procedures usually used by implantologists. One is based on a manual cleaning, the other on an ultra-sonic cleaning. The instrument observed by scan-electron-microscope, is a I.T.I. system drill. The results show the superiority of the ultra-sonic cleaning. The manual cleaning is especially ineffective on the inside and the cutting part of the drill. Even if ultra-sonic cleaning is definitely a better procedure, it has to be improved. A extensive study should be conducted to optimize the cleaning parameters, if not, single-use drill should be definitely preferred by implantologists.

Dental Implantation, Endosseous↗

[Raman spectrometry applied to calcified tissue and calcium-phosphorus biomaterials].

The rigid part of the human body consists essentially of carbonated apatite (calcium phosphate). Biologists don't have any tools to study this "mineral" phase, though its origin is organic. A new approach of some compounds like enamel or bone is obtained with the Raman micro-characterisation by a very fine analysis of chemical bonds in a micrometric scale. This method allows the characterisation, the analysis and the dosage of ions, like carbonate, acid phosphates, proteins and fatty acids. The identification of other organic or mineral compounds (e.g. calcium carbonate, calcium oxide, substitutant ions...) is also possible. The Raman microspectrometry can also be used to study the chemical and physical properties of biomaterials and their evolution after implantation in a dental or bone site. On synthetical calcium phosphate, beta-TCP, brushite and hydroxyapatite can be distinguished and the impurities found in plasma spray deposits can be measured. The detection of alpha-, beta-, or gamma-pyrophosphates could be obtained in some commercial beta-TCP. The Raman microspectrometry is the only non-destructive method which allows the identification of the chemical bonds in a micrometric scale and gives the "fingerprint" of the studied component.

Animals↗

Raman investigation of calcium carbonate bone substitutes and related biomaterials.

The interaction between biomaterials used in surgical procedures and the host bone is not yet perfectly understood. It appears that these problems may have been encountered because of insufficient characterisation of the basic component used in the synthesis of such biomaterials. Calcium carbonate (CaCO3) is interesting for bone filling or regeneration procedures because of its resorbability. The aim of this work is to compare different CaCO3 biomaterials and their basic source with the help of microRaman spectroscopy. Bionacre and Biocoral are analysed. The main bands of carbonate internal modes are observed around 1084-86 and 704-12 cm-1. In the lattice modes region, for both Biocoral and synthetic aragonite, two bands at 206 and 155 cm-1 are observed. The eggshell, oyster shell and synthetic calcite samples exhibit bands at 281 and 155 cm-1. Three bands are present at 280, 206 and 155 cm-1 on the Bionacre sample. The 206 and the 280 cm-1 bands are due to aragonite and calcite forms respectively. Therefore it appears to be a mixture of aragonite and calcite whereas Biocoral is pure aragonite. Additional Raman investigations should be of great interest in evaluating the structural modifications and their influence on the biological behaviour of these biomaterials. Lity index, the percentage of prematurity and of low birth weight are the indices of national health status.

Animals↗