PubMed Health⌕ Search

Biomedical subjects

G Pons Lladó

Publications and source records attributed to G Pons Lladó.

16 recordsLinked to original sources

[Patency study of internal mammary artery grafts: the usefulness of echo-enhancers for identifying the flow signal by color Doppler echocardiography].

OBJECTIVES: a) To study the capacity of the technique of high-frequency color Doppler to detect flow signal of left internal mammary artery grafts; b) to assess the usefulness of an echo-enhancer agent to facilitate the detection of the signal, and c) to evaluate the patency of the graft according to its pulsed Doppler velocity profile pattern. METHODS: 39 consecutive patients were studied. A Hewlett-Packard 5500 echocardiograph was used, with a high-frequency probe (S12) applied at the high left parasternal border. When a graft signal was not elicited after a predetermined 5-minute check period, an intravenous dose of 4 g of Levovist (Schering España) at 400 mg/ml was administrated. According to previous studies, a pulsed Doppler flow profile with a predominantly diastolic pattern was considered a normal graft patency, while a systolic one was deemed as abnormal. RESULTS: Graft flow was identified by color Doppler in 33/39 patients (85%). The additional use of an echo-enhancer in 6 patients with no detected signal increased this proportion to 38/39 (97%). Normal flow patterns were seen in 34/38 (89%). Among the four patients with abnormal pattern, 1 case of early myocardial infarction was observed, while angiographic studies showed distal occlusion of the graft in 1 or the presence of competitive flow in 2 patients. CONCLUSIONS: The high-frequency color Doppler technique allows the detection of a flow signal from internal mammary artery grafts in most patients. The administration of an echo-enhancer agent is useful in those with non detectable signals. An abnormal pulsed Doppler velocity pattern indicates graft malfunction.

Blood Flow Velocity↗

[Guidelines of the Spanish Society of Cardiology on magnetic resonance].

A wide perspective of the cardiac applications of magnetic resonance is presented in this report, including technical aspects of the practice, recommendations on the appropriate training of medical personnel for the practice of examination and also, an extensively commented review of the accepted clinical indications for the practice of a cardiac magnetic resonance imaging study at present.

Heart Diseases↗

[Current state of non-invasive methods in the study of coronary arteries and surgical bypass grafts].

The advantages of visualizing the coronary arteries by means of a non-invasive technique as an alternative to conventional angiography are obvious. Echocardiography and computed tomography have not proved to be useful in this application. Magnetic resonance imaging, however, has recently been reported as a method able to depict reliable images of the coronary vessels, including the visualization of stenotic lesions. Unfortunately, these preliminary data have not yet been followed by studies confirming the usefulness of the technique in practice, probably because of the complexity of the current magnetic resonance imaging methods and, also, to the difficulties that the intricate coronary arterial tree poses to a tomographic imaging method such as magnetic resonance imaging. On the other hand, in particular aspects of the spectrum of coronary diseases, as anomalous congenital origin of the vessels or assessment of patency of venous bypass grafts, magnetic resonance imaging has proved to be of value and may be considered a useful diagnostic tool in clinical practice.

Coronary Angiography↗

[Long-term results in patients with tricuspid prosthesis].

A retrospective study was undertaken of 31 patients submitted to tricuspid valve replacement between 1977 and 1988, either alone or associated to mitral or aortic replacement. The cause of the tricuspid lesion was rheumatic in 19 patients, congenital in seven, prosthetic valve thrombosis in two and miscellaneous in the remaining 3 patients (endocarditis, carcinoid syndrome, iatrogenic operative tricuspid regurgitation). Of the 31 tricuspid prostheses reviewed, 26 were mechanical (St Jude, Björk-Shiley) and five of the biological type (Ionescu, Hancock). Results showed that 25% of patients died in the hospital; 75% of them had been operated previously. With a follow-up averaging 3.9 years the complications related with the prosthesis were: thrombosis of the tricuspid prostheses in 1 patient (1.2% patients-year) and hemolytic anemia in another. Ninety percent of patient included in the follow-up were in NYHA class I or II. Three patients (14%) died due to a cause not directly related to the prosthesis. An actuarial analysis showed intrahospital survival rates of 55%, 100% and 75% in patient with 3, 2 and 1 prostheses, respectively; at 6 months postoperatively the figures were 55%, 87% and 75%, and at a follow-up of 3 years, 55%, 67% and 66%. In conclusion, in patients submitted to a tricuspid valve replacement mortality is high before hospital discharge, and is related to the clinical situation. A sustained improvement is observed in survivors once discharged, independently of the number of prostheses implanted. Complications related to the tricuspid prosthesis are comparable to those observed with prostheses in mitral or aortic position.

Adolescent↗

[Ambulatory transesophageal echocardiography: 2 years of experience].

In this report we study the value of ambulatory transesophageal echocardiography (TEE) in the clinical setting after a 2-year experience at our department. Since December 1988 until February 1991, 470 TEE examinations were indicated in 430 patients. Excluded were 8 cases, two out of them due to a formal contraindication and six who did not tolerate the procedure. The clinical indications for the examination, in the 462 studies performed, were as follows: possible cardiac source of emboli in 165 (35%); native mitral valve disease in 91 (20%); prosthetic valve dysfunction in 54 (12%); diseases of the aorta in 44 (10%); suspected infective endocarditis in 41 (9%); study of left ventricular function in 26 (6%); congenital heart disease in 18 (4%); tumor or intracardiac mass in 11 (2%); miscellaneous in 12 (2%). Based on this experience, we can conclude that TEE is a clinically useful technique for: 1) the study of mitral regurgitation, either native or prosthetic; 2) the detection of vegetations and abscesses in infective endocarditis; 3) the evaluation of a possible cardiac source of emboli; 4) the examination of the aorta in cases of suspected dissection; 5) the completion of the anatomic study in some congenital heart diseases, particularly after a surgical correction; 6) the study of patients with a technically inadequate transthoracic approach.

Adolescent↗