PubMed Health⌕ Search

Biomedical subjects

G R Heyndrickx

Publications and source records attributed to G R Heyndrickx.

At least 37 records · Page 2Linked to original sources

Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve.

BACKGROUND: To assess coronary lesion severity in the catheterization laboratory, several guide wire-based methods have been proposed. The purpose of the present study was to compare the feasibility and the reproducibility of coronary flow velocity reserve (CFVR), instantaneous hyperemic diastolic velocity-pressure slope index (IHDVPS), and pressure-derived myocardial fractional flow reserve (FFRmyo). METHODS AND RESULTS: From distal coronary pressure and flow velocity signals (0.014-in guide wires), CFVR, IHDVPS, and FFRmyo were computed in 15 stenoses (13 patients) under the four following pairs of conditions: (1) twice under baseline conditions; (2) during atrial pacing at 80 and 110 bpm; (3) before and during intravenous infusion of nitroprusside; and (4) before and during intravenous infusion of dobutamine. A total of 104 measurements were obtained. Both CFVR and FFRmyo could be calculated in all cases. IHDVPS could be calculated in only 79% of cases. The mean value of CFVR did not change between the two baseline measurements and during infusion of nitroprusside but decreased from 1.85 +/- 0.41 to 1.66 +/- 0.45 (P < .05) during atrial pacing and from 1.90 +/- 0.50 to 1.41 +/- 0.28 (P < .05) during dobutamine infusion. The mean values of IHDVPS and FFRmyo remained similar, whichever the changes in hemodynamic conditions. The coefficient of variation between two consecutive measurements was significantly lower for FFRmyo (4.2%) than for CFVR (17.7%) and for IHDVPS (24.7%). CONCLUSIONS: CFVR is easy to measure but sensitive to hemodynamic changes. IHDVPS can be measured only in < 80% of cases and is highly variable even without changes in hemodynamic conditions. FFRmyo is easy to measure and almost independent of hemodynamic changes.

Aged↗

Cyclic flow variations after angioplasty: a rare phenomenon predictive of immediate complications. DEBATE Investigator's Group.

Experimental studies and studies in human beings have indicated that cyclic flow variation (CFV) is a reliable marker of the formation of platelet aggregates and thus may be predictive of immediate complications after coronary angioplasty. In this study, the incidence and clinical relevance of CFV in a large patient population after elective percutaneous transluminal coronary angioplasty (PTCA) was assessed. One hundred two patients with one-vessel disease and no previous Q-wave myocardial infarction underwent angiographically successful PTCA of a single lesion of a major coronary artery. A Doppler guide wire inserted distal to the stenosis was used to monitor flow velocity continuously after PTCA for 15 minutes. In 94 (92%) of 102 patients, a stable and reliable Doppler signal could be recorded for 15 minutes after the procedure. CFV, defined as gradual decline in flow over several minutes followed by a sudden restoration to higher values, was observed in 4 patients. In 3 of these 4 patients, the occurrence of CFV was predictive of immediate complications (2 intracoronary thrombosis and 1 acute closure), whereas none of the patients without CFV (n = 90) showed acute closure during hospital stay. In conclusion, CFVs in patients after angiographically successful elective PTCA are rare (4.3%) but highly sensitive for the prediction of abrupt occlusion.

Aged↗

Relation between myocardial fractional flow reserve calculated from coronary pressure measurements and exercise-induced myocardial ischemia.

BACKGROUND: Myocardial fractional flow reserve (FFRmyo) is a functional index of stenosis severity that can be derived from intracoronary pressure measurements performed during maximal vasodilatation. It is defined as the maximal myocardial perfusion during hyperemia in the presence of a stenosis in the epicardial artery expressed as a fraction of its normal maximal expected value. To determine threshold values of FFRmyo, of hyperemic translesional pressure gradient (delta P(max)), and of resting translesional pressure gradient (delta P(rest)) that are uniformly associated with exercise-induced ischemia, we studied the relation between these pressure-derived indexes and the results of exercise ECG. METHODS AND RESULTS: We studied 60 patients with an isolated lesion in one major epicardial coronary artery, normal left ventricular function, and no left ventricular hypertrophy. Maximal exercise ECG (off anti-ischemic medication) was performed within 6 hours before catheterization. Intracoronary pressure measurements were taken at rest and during hyperemia with a pressure monitoring guide wire. ST-segment depressions at peak exercise (considered abnormal when > or = 0.1 mV) were compared with FFRmyo, delta P(max), and delta P(rest). Thirty-seven patients had an abnormal and 23 patients a normal exercise ECG. A significant linear correlation was found between the magnitude of ST-segment depressions and both FFRmyo and delta P(max) (r = -.75, SEE = 0.53; r = .71, SEE = 0.56). A weaker correlation was noted between ST-segment depressions and delta P(rest) (r = .53, SEE = 0.67). Sensitivity and specificity curves were constructed for the prediction of an abnormal exercise ECG for the three pressure-derived indexes. The values that most accurately predicted an abnormal exercise ECG were 66% for FFRmyo, 31 mm Hg for delta P(max), and 12 mm Hg for delta P(rest). No patient with a FFRmyo value > 72% showed an abnormal exercise ECG. In addition, receiver operating characteristic curves demonstrated a greater accuracy of FFRmyo and of delta P(max) than of delta P(rest) for predicting the results of the exercise ECG. CONCLUSIONS: In the present study, cutoff values of FFRmyo and translesional pressure gradients are established from the relation between intracoronary pressure-derived indexes and ECG signs of myocardial ischemia during maximal exercise. These values can be helpful for clinical decision making in cases with dubious angiographic results. Furthermore, our data support the concept that stenosis physiology is better reflected by hyperemic than by basal measurements.

Adult↗

Quantitative coronary angiography in predicting functional significance of stenoses in an unselected patient cohort.

OBJECTIVES: This study investigated the value of quantitative coronary angiography for predicting coronary flow reserve, as calculated from the transstenotic pressure gradient in a large, unselected patient cohort. BACKGROUND: In patients with extensive coronary artery disease, quantitative coronary angiographic findings fail to correlate with functional variables of coronary stenoses. New developments in pressure-monitoring wire technology permitted validation in humans of the concept of myocardial fractional flow reserve as assessed from coronary pressure measurements. METHODS: One hundred ten patients with normal left ventricular function were studied in the setting of coronary angioplasty. Quantitative coronary angiography was performed on-line using the ACA system. Myocardial and coronary fractional flow reserve were calculated from aortic and distal coronary pressures during maximal coronary hyperemia. RESULTS: When data before and after angioplasty were pooled, a curvilinear relation was found between myocardial fractional flow reserve and both diameter stenosis (r = 0.79) and minimal lumen diameter (r = 0.82), and a linear relation was found between myocardial fractional flow reserve and angiographic stenosis flow reserve (r = 0.78). Correlations between quantitative angiographic and pressure-derived indexes, although significant, were characterized by a large dispersion of the values of myocardial fractional flow reserve for a similar angiographic degree of stenosis. Nevertheless, the sensitivity and specificity of a minimal lumen diameter < 1.5 mm to predict myocardial fractional flow reserve < 0.72 were 96% and 89%, respectively. The corresponding values for a diameter stenosis > 50% were 93% and 85%, respectively. CONCLUSIONS: 1) In an unselected patient cohort, geometric indexes of stenosis severity derived from quantitative coronary angiography correlate significantly with physiologic variables, although these relations are imprecise in individual patients. 2) Nevertheless, the diagnostic accuracy of quantitative coronary angiography in predicting myocardial fractional flow reserve < 0.72 is high and allows its use for clinical decision making in the individual patient during diagnostic or interventional procedures.

Aged↗

Delineation of myocardial viability with PET.

UNLABELLED: Relative flow and metabolic imaging (the "mismatch pattern") with PET have been proposed to identify the presence of viable myocardium in patients with ischemic left ventricular dysfunction. Yet, optimal criteria to identify dysfunctional but viable myocardium and predict significant functional improvement have not been fully defined. METHODS: Dynamic PET imaging with 13N-ammonia and 18F-deoxyglucose to assess absolute myocardial perfusion and glucose uptake was performed in 25 patients (20 men, 5 women; mean age 57 +/- 12 yr, range 30-72 yr) scheduled for coronary revascularization because of coronary artery disease, anterior wall dysfunction and mildly depressed left ventricular ejection fraction (49% +/- 11%). Global and regional left ventricular function was evaluated by contrast left ventriculography at baseline and after revascularization. RESULTS: As judged from the changes in end-systolic volume and resting anterior wall motion before and after revascularization, 17 patients with improved wall motion score and decreased end-systolic volume were considered to have viable myocardium, whereas 8 patients with either no change in regional wall motion or increased end-systolic volume were considered to have nonviable myocardium. Before revascularization, viable myocardium showed higher absolute myocardial blood flow (77 +/- 20 versus 51 +/- 9 ml (min.100 g)-1, p = 0.004) and absolute regional myocardial glucose uptake (36 +/- 14 versus 24 +/- 11 mumole (min.100 g)-1, p = 0.04) than nonviable myocardium. CONCLUSION: This study identified absolute myocardial blood flow and normalized glucose extraction as the most powerful predictors of the return of contractile function after coronary revascularization in patients with ischemic anterior wall dysfunction.

Adult↗

Role of side holes in guide catheters: observations on coronary pressure and flow.

When performing coronary angioplasty, guide catheter intubation of the ostium often leads to a damping of the pressure tracing. In contrast, when a guide catheter with side holes is used, the pressure tracing is most often superimposable to the pressure wave recorded through the side arm of a femoral artery sheath introducer. This pressure wave gives the reassuring impression of normal hemodynamics in the coronary artery. To illustrate the role of guide catheter side holes and that guide catheter pressure does not necessarily equal the actual coronary artery perfusion pressure, we report observations on trans-ostial pressure gradients at rest and during increased coronary flow rates. An abbreviated in vivo study of side holes on the maximal achievable blood flow, employing timed blood flow collections in 7F and 8F side hole guide catheters, was made in 10 patients. At high mean aortic pressure levels, the blood flow through the side holes did not exceed 80 and 60 mL/min for 8 and 7F guide catheters, respectively. These observations suggest that, under some conditions, the guide catheter may produce a resting or hyperemic trans-ostial gradient and that the flow provided only by the side holes of guide catheter is limited. Guide catheter interference with normal flow should be considered in interventional procedures even when arterial pressure appears normal.

Adult↗

Assessment of left ventricular dysfunction by nuclear cardiology.

Nuclear cardiology techniques may be of help in evaluating the patient with symptoms of congestive heart failure and ventricular dysfunction in two respects: quantification of functional parameters by radionuclide angiography, and differentiation of viable from nonviable myocardium by perfusion and metabolic imaging. Left ventricular ejection fraction and volumes can be accurately assessed by equilibrium radionuclide angiography with a count-based method without any geometric assumptions. Indeed, because of its high reproducibility, this method is particularly suited for making sequential measurements in the same patient. The distinction between viable or reversible and scarred or irreversible dysfunctional myocardium can be made on the basis of myocardial perfusion, cell membrane integrity, and metabolic activity. Thallium myocardial imaging is used clinically to assess the first two parameters based on experimental data. Two clinical methods may be applied to the detection of viability: stress-redistribution-reinjection imaging or rest-redistribution imaging. In both of these, the severity of the reduction in thallium activity should be assessed to discriminate viable from nonviable myocardium. Stress-redistribution-reinjection thallium imaging should be the first approach, if possible, because inducible ischemia is a much more significant clinical variable in a patient with ventricular dysfunction in terms of management and risk assessment than is knowledge of myocardial viability. Positron emission tomography (PET) provides enhanced image resolution and correction for body attenuation, thereby overcoming the two major limitations of thallium imaging. In addition, it provides the capacity to quantitate regional blood flow and to assess regional metabolic activity independent of flow. Overall, the accuracies of thallium imaging (around 70%) and PET imaging (around 82%) are similar for the prediction of segmental changes after revascularization. However, in patients with poor global left ventricular function, the accuracy of PET seems to be better. Further studies are needed in a large number of patients evaluated for regional and global function to establish algorithms using thallium and PET imaging in dysfunctional myocardium. Dobutamine echocardiography should also be evaluated in these algorithms.

Cardiology↗

Randomized trial of a GPIIb/IIIa platelet receptor blocker in refractory unstable angina. European Cooperative Study Group.

BACKGROUND: Patients with unstable angina despite intensive medical therapy, ie, refractory angina, are at high risk for developing thrombotic complications: myocardial infarction or coronary occlusion during percutaneous transluminal coronary angioplasty (PTCA). Chimeric 7E3 (c7E3) Fab is an antibody fragment that blocks the platelet glycoprotein (GP) IIb/IIIa receptor and potently inhibits platelet aggregation. METHODS AND RESULTS: To evaluate whether potent platelet inhibition could reduce these complications, 60 patients with dynamic ST-T changes and recurrent pain despite intensive medical therapy were randomized to c7E3 Fab or placebo. After initial angiography had demonstrated a culprit lesion suitable for PTCA, placebo or c7E3 Fab was administered as 0.25 mg/kg bolus injection followed by 10 micrograms/min for 18 to 24 hours until 1 hour after completion of second angiography and PTCA. During study drug infusion, ischemia occurred in 9 c7E3 Fab and 16 placebo patients (P = .06). During hospital stay, 12 major events occurred in 7 placebo patients (23%), including 1 death, 4 infarcts, and 7 urgent interventions. In the c7E3 Fab group, only 1 event (an infarct) occurred (3%, P = .03). Angiography showed improved TIMI flow in 4 placebo and 6 c7E3 Fab patients and worsening of flow in 3 placebo patients but in none of the c7E3 Fab patients. Quantitative analysis showed significant improvement of the lesion in the patients treated with c7E3 Fab, which was not observed in the placebo group, although the difference between the two treatment groups was not significant. Measurement of platelet function and bleeding time demonstrated > 90% blockade of GPIIb/IIIa receptors, > 90% reduction of ex vivo platelet aggregation to ADP, and a significantly prolonged bleeding time during c7E3 Fab infusion, without excess bleeding. CONCLUSIONS: Combined therapy with c7E3 Fab, heparin, and aspirin appears safe. These pilot study results support the concept that effective blockade of the platelet GPIIb/IIIa receptors can reduce myocardial infarction and facilitate PTCA in patients with refractory unstable angina.

Abciximab↗

Coronary flow reserve calculated from pressure measurements in humans. Validation with positron emission tomography.

BACKGROUND: Experimental studies have shown that fractional flow reserve (defined as the ratio of maximal achievable flow in a stenotic area to normal maximal achievable flow) can be calculated from coronary pressure measurements only. The objectives of this study were to validate fractional flow reserve calculation in humans and to compare this information with that derived from quantitative coronary angiography. METHODS AND RESULTS: Twenty-two patients with an isolated, discrete proximal or mid left anterior descending coronary artery stenosis and normal left ventricular function were studied. Relative myocardial flow reserve, defined as the ratio of absolute myocardial perfusion during maximal vasodilation in the stenotic area to the absolute myocardial perfusion during maximal vasodilation (adenosine 140 micrograms.kg-1 x min-1 intravenously during 4 minutes) in the contralateral normally perfused area, was assessed by 15O-labeled water and positron emission tomography (PET). Myocardial and coronary fractional flow reserve were calculated from mean aortic, distal coronary, and right atrial pressures recorded during maximal vasodilation. Distal coronary pressures were measured by an ultrathin, pressure-monitoring guide wire with minimal influence on the trans-stenotic pressure gradient. Minimal obstruction area, percent area stenosis, and calculated stenosis flow reserve were assessed by quantitative coronary angiography. There was no difference in heart rate, mean aortic pressure, or rate-pressure product during maximal vasodilation during PET and during catheterization. Percent area stenosis ranged from 40% to 94% (mean, 77 +/- 13%), myocardial fractional flow reserve from 0.36 to 0.98 (mean, 0.61 +/- 0.17), and relative flow reserve from 0.27 to 1.23 (mean, 0.60 +/- 0.26). A close correlation was found between relative flow reserve obtained by PET and both myocardial fractional flow reserve (r = .87) and coronary fractional flow reserve obtained by pressure recordings (r = .86). The correlations between relative flow reserve obtained by PET and stenosis measurements derived from quantitative coronary angiography were markedly weaker (minimal obstruction area, r = .66; percent area stenosis, r = -.70; and stenosis flow reserve, r = .68). CONCLUSIONS: Fractional flow reserve derived from pressure measurements correlates more closely to relative flow reserve derived from PET than angiographic parameters. This validates in humans the use of fractional flow reserve as an index of the physiological consequences of a given coronary artery stenosis.

Coronary Angiography↗

Usefulness of repeat coronary angiography 24 hours after successful balloon angioplasty to evaluate early luminal deterioration and facilitate quantitative analysis.

Because of the unavoidable occurrence of vessel disruption after successful coronary balloon angioplasty, the reliability of quantitative angiographic analysis in that setting has been questioned. For this reason and the suggested occurrence of delayed elastic recoil, repeat angiography at 24 hours has been advocated in clinical interventional trials. In this study, these issues are confronted by performing comprehensive quantitative analysis (Cardiovascular Angiographic Analysis System) of coronary angiograms, acquired in multiple identical projections immediately after and 24 hours after angioplasty, in 102 patients with 110 successfully dilated lesions. Vasomotion was controlled by intracoronary nitrate before angiography and all patients were fully anticoagulated (activated partial thromboplastin time 85 to 120 seconds) for > 24 hours. Paired Student's t tests applied to angiographic measurements revealed that there was no significant deterioration in minimal luminal diameter or cross-sectional area from immediately after angioplasty to 24 hours later. It can thus be inferred that there is no phenomenon of delayed elastic recoil, at least during this time period. Measurement accuracy and precision of the Cardiovascular Angiographic Analysis System from the postangioplasty angiogram are highly acceptable, at < 0.01 and +/- 0.20 mm, respectively. Therefore, it is concluded that routine repeat 24-hour angiography is not indicated after successful angioplasty. A highly significant increase (p < 0.001) in reference diameter (+0.11 +/- 0.18 mm) was responsible for the apparent increase in percent diameter stenosis (2.4 +/- 7%), a finding that demonstrates the potential for error by selective application of percent diameter stenosis measurements alone. Preferential use of absolute luminal measurements is thus strongly recommended for clinical trials with angiographic monitoring.

Adult↗

Percutaneous transluminal coronary angioplasty catheters versus fluid-filled pressure monitoring guidewires for coronary pressure measurements and correlation with quantitative coronary angiography.

The functional significance of a coronary stenosis can be assessed by measuring the translesional pressure gradient. Thirty-four patients were studied in the setting of percutaneous transluminal coronary angioplasty (PTCA) to evaluate the clinical relevance of the pressure gradient measurements by means of a PTCA balloon catheter. Both before and after PTCA, the mean pressure gradient across the stenosis was measured by means of a newly developed, 0.015-inch pressure-monitoring guidewire, first with only the wire across the stenosis (delta Pw, considered as the actual gradient), and second with the deflated balloon catheter advanced over the wire in the stenosis (delta Pb). Pressure gradients were correlated with quantitative coronary angiography of the stenotic segment. Before PTCA, mean delta Pb was larger than delta Pw (62 +/- 14 vs 30 +/- 20 mm Hg; p < 0.01). After PTCA, delta Pb remained systematically higher than delta Pw (23 +/- 14 vs 3 +/- 5 mm Hg; p < 0.01), despite a significant reduction of percent area stenosis from 84 +/- 9 to 46 +/- 17%, and an increase in minimal obstruction area from 0.98 +/- 0.48 to 3.49 +/- 1.32 mm2. A significant correlation was found between delta Pw and percent area stenosis (r2 = 0.66), with a marked increase after percent area stenosis reached 80%. The correlation between delta Pb and percent area stenosis was weaker (r2 = 0.53), the scatter of the data was larger, and the inflection point of the curve was shifted toward less severe degrees of stenosis severity.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Usefulness of quantitative and qualitative angiographic lesion morphology, and clinical characteristics in predicting major adverse cardiac events during and after native coronary balloon angioplasty. CARPORT and MERCATOR Study Groups.

Major, adverse cardiac events (death, myocardial infarction, bypass surgery and reintervention) occur in 4 to 7% of all patients undergoing coronary balloon angioplasty. Prospectively collected clinical data, and angiographic quantitative and qualitative lesion morphologic assessment and procedural factors were examined to determine whether the occurrence of these events could be predicted. Of 1,442 patients undergoing balloon angioplasty for native primary coronary disease in 2 European multicenter trials, 69 had major, adverse cardiac procedural or in-hospital complications after > or = 1 balloon inflation and were randomly matched with patients who completed an uncomplicated in-hospital course after successful angioplasty. No quantitative angiographic variable was associated with major adverse cardiac events in univariate and multivariate analyses. Univariate analysis showed that major adverse cardiac events were associated with the following preprocedural variables: (1) unstable angina (odds ratio [OR] 3.11; p < 0.0001), (2) type C lesion (OR 2.53; p < 0.004), (3) lesion location at a bend > 45 degrees (OR 2.34; p < 0.004), and (4) stenosis located in the middle segment of the artery dilated (OR 1.88; p < 0.03); and with the following postprocedural variable: angiographically visible dissection (OR 5.39; p < 0.0001). Multivariate logistic analysis was performed to identify variables independently correlated with the occurrence of major adverse cardiac events. The preprocedural multivariate model entered unstable angina (OR 3.77; p < 0.0003), lesions located at a bend > 45 degrees (OR 2.87; p < 0.0005), and stenosis located in the middle portion of the artery dilated (OR 1.95; p < 0.04).(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

Transstenotic coronary pressure gradient measurement in humans: in vitro and in vivo evaluation of a new pressure monitoring angioplasty guide wire.

OBJECTIVES: The present study was designed to investigate 1) the feasibility and accuracy of coronary pressure measurements with a novel 0.015-in. (0.038 cm) fluid-filled guide wire, and 2) the effect of the guide wire itself on stenosis hemodynamics. BACKGROUND: To assess the functional results of coronary angioplasty, measurements of the transstenotic pressure gradient have been advocated. However, this gradient is no longer routinely measured because it is not reliable when determined with the angioplasty catheter. METHODS: A fluid-filled 0.015-in. guide wire to be connected to a conventional pressure transducer was developed. Five wires were tested for their frequency response characteristics and for their accuracy in measuring hydrostatic pressure. In an in vitro model of stenosis (reference diameter 4 mm), the pressure gradient was determined at incremental flow levels for varying stenosis severity with and without a 0.015-in. guide wire through the narrowing. In 37 patients, the transstenotic pressure gradient was measured before and after angioplasty and compared with obstruction area and percent area stenosis as determined by quantitative coronary angiography. RESULTS: The correlation between the actual pressure and the pressure recorded by the guide wire was excellent (r = 0.98) despite a slight underestimation (-3 +/- 5%). Phasic pressure recordings were precluded by a long time constant of 16 +/- 4 s. The presence of the guide wire produced a significant overestimation (> 20%) of the pressure decrease only in cases of tight stenosis (> 90% area reduction). Furthermore, a theoretic model based on the fluid dynamic equation predicted that this overestimation was inversely proportional to the reference diameter of the vessel, yet was only slightly influenced by the flow. The lesion was crossed in all but one patient (97%) and pressure gradient was recorded throughout the study in 34 (94%) of 36 patients. The mean pressure gradient decreased from 30 +/- 19 before to 3 +/- 5 mm Hg after angioplasty (p < 0.01). A curvilinear relation was found between the pressure gradient and both percent area stenosis (r2 = 0.67) and obstruction area (r2 = 0.72). A sharp increase in pressure gradient was noted once the stenosis exceeded 75% area reduction. CONCLUSIONS: Mean transstenotic pressure gradients can be easily and reliably recorded with a 0.015-in. fluid-filled guide wire. This ability should facilitate the functional assessment of coronary stenoses of intermediate severity and of immediate postangioplasty results.

Adult↗

Regional wall motion abnormalities in stunned and hibernating myocardium.

The clinical recognition that chronic dysfunctioning myocardial segments may retain viable myocardium has important therapeutic consequences. 'Stunned myocardium' and 'hibernating myocardium' have been proposed to distinguish respectively between post-ischaemic left ventricular dysfunction, a condition which normalizes spontaneously, and persistent wall motion abnormalities due to chronic hypoperfusion. This study examines the possible link between these two conditions.

Animals↗

Competition between palmitate and ketone bodies as fuels for the heart: study with positron emission tomography.

To test the ability of ketone bodies to inhibit myocardial fatty acid oxidation in vivo, the myocardial clearance kinetics of [1-11C]palmitate was assessed with positron emission tomography in six fasted volunteers and six instrumented dogs, studied repeatedly before and during infusion of 3-hydroxybutyrate (17 mumol.kg-1 x min-1). With the use of multiexponential fitting of tissue time-activity curves, the size, half time (T1/2), and index of the early rapid phase of 11C myocardial clearance, reflecting palmitate oxidation, were calculated. In humans, the relative size (-28%, P < 0.001) and index (-37%, P < 0.01) of the early rapid phase decreased significantly during infusion of 3-hydroxybutyrate, consistent with decreased fatty acid oxidation. Paradoxically, T1/2 decreased from 10.1 +/- 1.6 to 7.4 +/- 1.1 min (P < 0.01). To elucidate possible mechanisms, multiple coronary arteriovenous samples were obtained from the dogs to assess the efflux of oxidized and nonmetabolized tracer. Infusion of 3-hydroxybutyrate resulted in decreased myocardial [11C]CO2 production (-40%, P < 0.05) and reduced palmitate retention (-38%, P < 0.05). In three dogs, the arteriovenous difference in radiolabeled palmitate became negative 10 min after injection, indicating backdiffusion of nonmetabolized tracer from the myocardium. Thus a steady-state infusion of 3-hydroxybutyrate, resulting in physiological plasma levels, alters [1-11C]palmitate kinetics in vivo by decreasing myocardial long-chain fatty acid oxidation and by increasing backdiffusion of nonmetabolized tracer.

3-Hydroxybutyric Acid↗

Mechanisms of chronic regional postischemic dysfunction in humans. New insights from the study of noninfarcted collateral-dependent myocardium.

BACKGROUND: Even in the absence of a previous myocardial infarction, patients with coronary artery disease often present with chronic regional wall motion abnormalities that are reversible spontaneously or after coronary revascularization. In these patients, regional dysfunction has been proposed to result either from prolonged postischemic dysfunction (myocardial "stunning") or from adaptation to chronic hypoperfusion (myocardial "hibernation"). This study examines which of these two mechanisms is responsible for the chronic regional dysfunction often detected in patients with angina and noninfarcted collateral-dependent myocardium. METHODS AND RESULTS: Twenty-six anginal patients (19 men; mean age, 60 +/- 9 years old) with chronic occlusion of a major coronary artery but without previous infarction were studied. Positron emission tomography was performed to measure absolute regional myocardial blood flow with 13N-ammonia at rest (n = 26) and after intravenous dipyridamole (n = 11). The kinetics of 18F-deoxyglucose and 11C-acetate were measured to calculate the rate of exogenous glucose uptake and the regional oxidative metabolism (n = 15). Global and regional left ventricular function was evaluated by contrast ventriculography at baseline (n = 26) and after revascularization (n = 12). Transmural myocardial biopsies from the collateral-dependent area were obtained in seven patients during bypass surgery and analyzed by optical and electron microscopy. According to resting regional wall motion, patients were separated into groups with and without dysfunction of the collateral-dependent segments. In patients with normal wall motion (n = 9), regional myocardial blood flow, oxidative metabolism, and glucose uptake were similar among collateral-dependent and remote segments. By contrast, in patients with regional dysfunction (n = 17), collateral-dependent segments had lower myocardial blood flow (77 +/- 25 versus 95 +/- 27 mL.min-1.100 g-1, p < 0.001), smaller k values (slope of 11C clearance reflecting oxidative metabolism, 0.049 +/- 0.015 versus 0.068 +/- 0.020 min-1, p < 0.001) and higher glucose uptake (relative 18F-deoxyglucose-to-flow ratio of 1.9 +/- 1.6 versus 1.2 +/- 0.2, p < 0.05) compared with remote segments. However, myocardial blood flow and k values were similar among collateral-dependent segments of patients with and without segmental dysfunction. After intravenous dipyridamole, collateral-dependent myocardial blood flow increased from 78 +/- 5 to 238 +/- 54 mL.min-1.100 g-1 in three patients with normal wall motion and from 88 +/- 17 to only 112 +/- 44 mL.min-1.100 g-1 in eight patients with regional dysfunction. There was a significant (r = -0.85, p < 0.001) inverse correlation between wall motion abnormality and collateral flow reserve. Analysis of the tissue samples obtained at the time of bypass surgery showed profound structural changes in dysfunctioning collateral-dependent areas, including cellular swelling, loss of myofibrillar content, and accumulation of glycogen. Despite these alterations, the regional wall motion score improved significantly in the patients studied before and after revascularization (from 3.8 +/- 1.3 to 0.8 +/- 0.9, p < 0.005). CONCLUSIONS: In a subgroup of patients with noninfarcted collateral-dependent myocardium, immature or insufficiently developed collaterals do not provide adequate flow reserve. Despite nearly normal resting flow and oxygen consumption, these collateral-dependent segments exhibit chronically depressed wall motion and demonstrate marked ultrastructural alterations on morphological analysis. We propose that these alterations result from repeated episodes of ischemia as opposed to chronic hypoperfusion and represent the flow, metabolic, and morphological correlates of myocardial "hibernation."

Aged↗

Comparative effects of ischemia and hypoxemia on left ventricular systolic and diastolic function in humans.

BACKGROUND: During the initial phase of an ischemic insult, left ventricular (LV) performance depends on the complex interaction between oxygen deprivation, vascular turgor, and accumulation of metabolites. In experimental preparations, low-flow ischemia decreases systolic shortening and increases diastolic LV distensibility, whereas pacing-induced ischemia or hypoxic perfusion produces smaller decreases in systolic shortening but decreases LV diastolic distensibility. The purpose of this study was to investigate the different effects of low-flow ischemia, pacing-induced ischemia, and hypoxemic perfusion on LV performance in humans. METHODS AND RESULTS: In 20 patients with a significant stenosis in the left anterior descending coronary artery, micromanometer-tip LV pressure recordings (n = 20), LV angiography (n = 18), and coronary sinus blood sampling (n = 11) were obtained at rest and during the following conditions: pacing-induced ischemia (PI) (n = 11), low-flow ischemia of balloon coronary occlusion (CO) (n = 20), and hypoxemia induced by balloon coronary occlusion with hypoxemic perfusion distal to the occlusion (CO+P) (n = 11). LV stroke work index fell from 75 +/- 17 g.m at rest to 43 +/- 14 g.m at the end of CO (n = 18; P < .001). In addition, LV stroke work index was lower at the end of CO than during PI (50 +/- 11 vs 77 +/- 15 g.m; n = 11; P < .002) and was lower at the end of CO than at the end of CO+P (35 +/- 7 vs 46 +/- 9 g.m; n = 9; P < .02). LV end-diastolic pressure rose from 16 +/- 5 mm Hg at rest to 23 +/- 6 mm Hg at the end of CO (n = 20; P < .001). However, LV end-diastolic pressure was lower at the end of CO than during PI (20 +/- 5 vs 30 +/- 5 mm Hg; n = 11; P < .002) and was lower at the end of CO than at the end of CO+P (26 +/- 5 vs 34 +/- 7 mm Hg; n = 11; P < .01). LV end-diastolic volume index increased from 75 +/- 14 mL/m2 at rest to 79 +/- 15 mL/m2 at the end of CO (n = 18; P < .05). Left ventricular end-diastolic volume index increased to values similar to those for CO during PI (79 +/- 13 mL/m2; n = 11; P = NS) and at the end of CO+P (78 +/- 14 mL/m2; n = 9; P = NS). Higher values of LV end-diastolic pressure and unchanged values of LV end-diastolic volume index for PI and CO+P, compared with CO, suggested a lower end-diastolic LV distensibility during PI and during hypoxemia, as compared with low-flow ischemia. Upward shifts of individual diastolic LV pressure-volume curves during PI (9 of 11 patients) and at the end of CO+P (7 of 9 patients), compared with CO, were also consistent with lower LV diastolic distensibility during pacing-induced ischemia and during hypoxemia, compared with low-flow ischemia. Coronary sinus lactate, H+, and K+ levels increased after balloon deflation (CO and CO+P) and during pacing (PI). CONCLUSIONS: Thus, during low-flow ischemia, LV systolic performance was lower and LV diastolic distensibility larger than during pacing-induced ischemia or hypoxemia. The variable response of the human myocardium to different types of ischemia was probably related to the degree of vascular turgor and accumulation of tissue metabolites.

Adult↗