Modelling steady state pulmonary elimination of He, SF6 and CO2: effect of morphometry.

We studied the influence of acinar morphometry on the shape of simulated expirograms computed from a single path convection-diffusion model that includes a source term for gas evolution from the blood (Scherer et al., J. Appl. Physiol. 64: 1022-1029, 1988). Acinar structure was obtained from published data of 3 different lung morphometries. The simulations were performed over a range of tidal volumes (VT) and breathing frequencies (f) comparable to those observed in a previously reported human study. Airways dead space (VDaw) increased with VT in all the morphometric models tested and in the experimental data. The increase in VDaw with VT was inversely related to the diffusivity of the evolving gas and to the rate of increase in airway cross-section of the most mouthward (proximal) alveolated generations of the models. Normalized phase III slope for all the gases decreased with increasing VT in all the models as was previously reported for healthy human subjects. In the model simulations, the greatest sensitivity of phase III slope to VT was seen with the least diffusible gas using the airway morphometry with the smallest cross-sectional areas in the proximal alveolated generations. We conclude that both VDaw and phase III slope of an evolving gas are sensitive to the geometry of the proximal acinar airways and that this is manifest by their dependence on tidal volume, breathing frequency, molecular diffusivity and alveolar/blood source emission rate. The model simulations indicate that heterogeneity of gas washout is not required to explain the magnitude of the phase III slope in healthy human subjects.

Carbon Dioxide

Sensitivity of CO2 washout to changes in acinar structure in a single-path model of lung airways.

A numerical solution of the convection-diffusion equation with an alveolar source term in a single-path model (SPM) of the lung airways simulates steady state CO2 washout. The SPM is used to examine the effects of independent changes in physiologic and acinar structure parameters on the slope and height of Phase III of the single-breath CO2 washout curve. The parameters investigated include tidal volume, breathing frequency, total cardiac output, pulmonary arterial CO2 tension, functional residual capacity, pulmonary bloodflow distribution, alveolar volume, total acinar airway cross sectional area, and gas-phase molecular diffusivity. Reduced tidal volume causes significant steepening of Phase III, which agrees well with experimental data. Simulations with a fixed frequency and tidal volume show that changes in blood-flow distribution, model airway cross section, and gas diffusivity strongly affect the slope of Phase III while changes in cardiac output and in pulmonary arterial CO2 tension strongly affect the height of Phase III. The paper also discusses differing explanations for the slope of Phase III, including sequential emptying, stratified inhomogeneity, and the issue of asymmetry, in the context of the SPM.

Carbon Dioxide

Diffusivity, respiratory rate and tidal volume influence inert gas expirograms.

We modified, and developed software for, a computer-controlled quadrupole mass spectrometer to measure complete breath-by-breath expirograms of helium (He) and sulfur hexafluoride (SF6) exhaled during the infusion of saline saturated with the inert gases. He and SF6 have similar blood solubilities but very different gas phase diffusivities allowing examination of the influence of gas phase diffusivity on steady state inert gas expirograms. We studied six normal human volunteers in nine separate studies and examined the influence of tidal volume (VT) and breathing frequency (f) on the airways dead space (VDaw) and alveolar plateau slope (phase III) for the inert gases and CO2. The experimental data showed a reduction in VDaw with rapid shallow breathing, while phase III slope increased by a factor of two to three. We critically evaluated the data and methodology of these and previously reported studies of continuous and single breath washout of He and SF6. In general the 15 to 20 ml differences in VDaw between He and SF6 were in keeping with previous studies by others. The ratio of phase III slopes of SF6 to He reported by us previously (Scherer et al., J. Appl. Physiol. 64: 1022-1029, 1988) was 3.13. In the current study, which includes the analysis of more than 400 He and SF6 breaths, the ratio of SF6 to He slope was 1.85. The difference between the two studies was largely related to the improved methodology of the current study, particularly for the measurement of He. The results support the conclusion that diffusivity is an important component of both phase II and phase III of the expirogram. However, the difference in phase III between He and SF6 is somewhat less than previously reported.

Adult

Commercial double-indicator-dilution densitometer using heavy water: evaluation in oleic-acid pulmonary edema.

We evaluated a commercially available, double-indicator-dilution densitometric system for the estimation of pulmonary extravascular water volume in oleic acid-induced pulmonary edema. Indocyanine green and heavy water were used as the nondiffusible and diffusible tracers, respectively. Pulmonary extravascular water volume, measured with this system, was 67% of the gravimetric value (r = 0.91), which was consistent with values obtained from the radioisotope methods. The measured volume was not influenced by changes in cardiac index over a range of 1 to 4 L.min.m2. This system is less invasive than the thermal-dye technique and has potential for repeated clinical measurements of pulmonary extravascular lung water and cardiac output.

Animals

Evaluation of heavy water for indicator dilution cardiac output measurement.

We evaluated deuterium oxide (D2O) as a tracer for cardiac output measurements. Cardiac output measurements made by thermodilution were compared with those made by indicator dilution with D2O and indocyanine green as tracers. Five triplicate measurements for each method were made at intervals of 30 minutes in each of 9 anesthetized, mechanically ventilated goats. Cardiac output ranged between 0.68 and 3.79 L/min. The 45 data points yielded a correlation coefficient of 0.948 for the comparison of D2O indicator dilution cardiac output measurements with thermodilution measurements and a linear regression slope of 1.046. D2O indicator dilution measurements were biased by -0.11 +/- 0.22 L/min compared with thermodilution measurements and had a standard deviation of +/- 0.12 L/min for triplicate measurements. Hematocrits ranging between 20 and 50 vol% had no effect on optical density for D2O. D2O is more stable than indocyanine green and approximately one-tenth the price (40 cents per injection compared with $4). The basic instrumentation cost of approximately $9,000 is an additional initial expense, but provides the ability to perform pulmonary extravascular water measurements with a double-indicator dilution technique. D2O has potential as a tracer for the clinical determination of indicator dilution cardiac output measurements and pulmonary extravascular water measurements.

Animals

Permeation of inert gases through human skin: modeling the effect of skin blood flow.

We present an analytic method for determining the effects of skin perfusion--vasculature and flow rates--on the flux of inert gases through human skin. We systematically specify the underlying blood flow and examine the resulting fluxes of several gases, allowing for the appropriate tissue resistances. For physiological flows, the stratum corneum has an effect equivalent to a series resistance. Helium flux at low total flow depends primarily on subdermal perfusion, but at higher flow, middermal and subpapillary effects become important. The fluxes of less permeable gases, such as argon and xenon, depend on middermal and subpapillary flow at lower total flows. From any single measurement of gas flux, it is difficult to establish an unambiguous value for the underlying blood flow, but the simultaneous measurement of different gases narrows the range of plausible conditions.

Argon

The use of quantitative perfusion fluorometry to measure relative tumor and liver blood flow after transient microembolization.

Optimal chemotherapy delivery to the tumor depends on regional drug concentration, tumor perfusion, tissue drug uptake, and metabolism. Modulation of tumor blood flow has been used to improve tumor response to treatment. Transient microembolization is one method to alter regional blood flow, but its effects on relative changes in tumor and liver blood flow have not been previously measured. This study used quantitative perfusion fluorometry (QPF) to evaluate blood flow distribution in liver and tumor before and after hepatic arterial infusion of degradable starch microspheres (DSMs) in 10 New Zealand white rabbits. QPF was compared with radioactive xenon-133 washout, an established method for measuring blood flow. Xenon-133 was injected intraparenchymally and the clearance rate was measured allowing calculation of relative blood flow. QPF was then used to measure liver and tumor blood flow in a hepatic VX-2 tumor model after hepatic artery injection of DSMs. Initial tumor blood flow was 55% of liver flow. DSMs produced a significant and transient decrease in hepatic blood flow that was decreased to 40% of baseline after 25 min. Changes in relative hepatic blood flow after DSMs as measured by QPF correlated strongly with results obtained by xenon-133 washout (R = 0.97, P less than 0.01). Fluorometry's simplicity and reliability may be clinically useful to evaluate tumor blood flow characteristics.

Animals

Skin blood flow from gas transport: helium xenon and laser Doppler compared.

A study was designed to compare three independent measures of cutaneous blood flow in normal healthy volunteers: xenon-133 washout, helium flux, and laser velocimetry. All measurements were confined to the volar aspect of the forearm. In a large group of subjects we found that helium flux through intact skin changes nonlinearly with the controlled local skin temperature whereas helium flux through stripped skin, which is directly proportional to skin blood flow, changes linearly with cutaneous temperature over the range 33 degrees to 42 degrees. In a second group of six volunteers we compared helium flux through stripped skin to xenon-133 washout (intact skin) at a skin temperature of 33 degrees, and we found an essentially linear relationship between helium flux and xenon measured blood flow. In a third group of subjects we compared helium flux blood flow (stripped skin) to laser doppler velocimetric (LDV) measurements (intact skin) at adjacent skin sites and found a nonlinear increase in the LDV skin blood flow compared to that determined by helium over the same temperature range. A possible explanation for the nonlinear increases of helium flux through intact skin and of LDV output with increasing local skin temperature is that they reflect more than a change in blood flow. They may also reflect physical changes in the stratum corneum, which alters its diffusional resistance to gas flux and its optical characteristics.

Blood Flow Velocity

Numerical and experimental study of steady-state CO2 and inert gas washout.

The predictions of a single-path trumpet-bell numerical model of steady-state CO2 and infused He and sulfur hexafluoride (SF6) washout were compared with experimental measurements on healthy human volunteers. The mathematical model used was a numerical solution of the classic airway convention-diffusion equation with the addition of a distributed source term at the alveolar end. In the human studies, a static sampling technique was used to measure the exhaled concentrations and phase III slopes of CO2, He, and SF6 during the intravenous infusion of saline saturated with a mixture of the two inert gases. We found good agreement between the experimentally determined normalized slopes (phase III slope divided by mixed expired concentration) and the numerically determined normalized slopes in the model with no free parameters other than the physiological ones of upper airway dead space, tidal volume, breathing frequency, and breathing pattern (sinusoidal). We conclude 1) that the single-path (Weibel) trumpet-bell anatomic model used in conjunction with the airway convection-diffusion equation with a distributed source term is adequate to describe the steady-state lung washout of CO2 and infused He and SF6 in normal lungs and 2) that the interfacial area separating the tidal volume fron from the functional residual capacity gas, through which gas diffusion into the moving tidal volume occurs, exerts a major effect on the normalized slopes of phase III.

Carbon Dioxide

An evaluation of the Bentley PFF-100 transfusion filter.

The effects of a new transfusion filter (Bentley PFF-100) on stored whole blood have been examined. Six filters were preloaded by passage of two units of outdated type-specific bank blood and the effects of filtration on a third unit of 21-day-old blood flowing under 19.95 kPa (150 mm Hg) pressure were measured. Filtration did not significantly alter erythrocyte or leukocyte count, total or plasma haemoglobin, red cell fragility, plasma sodium, potassium, albumin, or globulin. Platelet counts were reduced by 31%. Removal of microaggregates, assessed by Coulter counting, screen filtration pressure, total screen protein, wet and dry weight of material retained and scanning electron microscopy, was shown to be effective over the entire range of particle size. In comparison with other transfusion filters previously examined in this laboratory, the Bentley PFF-100 filter combines the feature of moderately efficient microaggregate removal with rapid blood flow rate. Compared to its predecessor, the Bentley PF-127, this new filter design has improved flow characteristics without loss of efficiency of microaggregate removal.

Blood Preservation

Inert gas a-A differences: a direct reflection of V/Q distribution.

A computer model was developed to study the relationship between ventilation-to-perfusion (V/Q) mismatch and the development of inert gas arterial-to-alveolar partial pressure differences (a-A differences). Increasing inhomogeneity of V/Q ratio is revealed directly as an increase in the a-A difference of each gas. The quantitative relationships between the Q vs. V/Q distribution and the fractional a-A difference solubility plot (a-A difference plot) were studied and described. These studies demonstrated that for log normally distributed V/Q ratios, the area under the a-A difference plot is linearly related to the log variance of the V/Q distribution and can be estimated directly from the values obtained from six gases. The maximum a-A difference occurs for a gas whose solubility is numerically equal to the mean V/Q. The effects of departure from log normality and multimodality are discussed. We conclude from these studies that quantitative information regarding the degree of inhomogeneity of V/Q for log normal distribution is available from direct calculations of inert gas retention and excretion data. Qualitative information is also available indicating the departure from log normality and the region toward which the distribution is skewed.

Biophysical Phenomena

Principles and hazards of electrosurgery including laparoscopy.

The understanding of the basic principles governing current flow through the body is necessary for the safe application of electrosurgical technique. They also may provide a guide to the design of laboratory studies which are needed to understand completely the ubiquitous nature of radiofrequency current distribution in surgical procedures.

Burns, Electric

Effects of Intersept micropore filtration of blood on microaggregates and other constituents.

Micropore filtration (Intersept) of whole, stored blood was examined in two studies. In Study A, 1 unit of 14-day-old blood flowed by gravity across the filter. In Study B, the filter was preloaded by passage of 2 units of blood, and the effects on a third, consisting of 21-day-old blood, flowing under 150 mm Hg pressure, were examined. Filtration did not significantly alter erythrocyte count, total hemoglobin, plasma hemoglobin, erythrocyte fragility, plasma sodium, potassium, albumin, or globulin in either study, although some platelets and leukocytes were removed. Microaggregates, assessed by Coulter counting, screen filtration pressure, total screen proteins, wet and dry weights of material retained, and scanning electron microscopy, were satisfactorily removed over the whole range of particle sizes. Comparison with the Bentley PFS-127, Fenwal 4C2417, Pall Ultipore, and Swank IL200 filters led to the conclusion that the Intersept is the most efficient filter available at the present time for removing microaggregates during massive blood transfusion.

Blood