PubMed HealthSearch

Biomedical subjects

G R Parr

Publications and source records attributed to G R Parr.

At least 19 recordsLinked to original sources

High-voltage electron microscopy and conventional transmission electron microscopy of the interface zone between bone and endosteal dental implants.

The interface between mandibular bone and endosteal dental implants was examined with an in vivo dog model. Undecalcified mandibular implant samples were observed with both conventional transmission electron microscopy and high-voltage transmission electron microscopy (HVEM). Results demonstrated the variable nature of the interfacial support tissues. Mineralized bone was often found within 50 nm of the implant surface, separated from that surface only by an electron dense deposit. Osteocytes were observed close to the interface encased within lacunae extending numerous cellular processes through canaliculi. An osteoblast was also observed directly at the interface within a developing lacuna. Other interfacial areas exhibited a finely fibrillar and more electron lucent morphology. Furthermore, other areas were shown to be composed of wider zones of extracellular products containing collagen fibrils, ground substance, and calcified inclusions. Because bone is an actively growing and remodeling tissue, these different morphological zones around the entire area of the implants would appear to confirm the dynamic tissue response to endosteal dental implants. Further, HVEM stereology was shown to be an exciting research tool to investigate this tissue response.

Animals

Comparative implant research in dogs: a prosthodontic model.

One-hundred twenty endosteal dental implants were inserted bilaterally in the mandibles of 30 adult mongrel dogs after bilateral extraction of all premolars. The 120 implants were evenly divided into one- and two-stage systems and included ceramic and titanium cylindrical root-form implants and titanium blade implants. The research design of this investigation divided the 30 animals into 10 groups of three dogs. This article describes an animal model that is useful in evaluating dental implant designs and compares the results with those from humans. In particular, this article delineates the prosthodontic approach appropriate for this model using one- and two-stage titanium implants. Rexillium alloy fixed prostheses were placed on 32 endosteal implants and 16 natural mandibular molar teeth. The implants and prosthetic components of the Sterio-Oss implant system were used. All prostheses are functional with minimal maintenance. To date, after 1-year of follow-up, none of the implants have been lost and none of the fixed prostheses have required recementation or maintenance other than normal hygiene. Histologic and survival data as well as results with other implant systems will be presented in other reports.

Animals

A light and electron microscopic comparison of osseointegration of six implant types.

This study compared six commercially available implants placed in an animal model for 5 months. Twelve of the implants were used for light microscopic analysis, and the remaining 12 were used for scanning electron microscopic analysis. With the exception of one implant, newly formed bone was evident in direct apposition to portions of all control implants. The light microscopic and scanning electron microscopic evaluations of the tissues surrounding the six commercially available implant types indicated that initial osseointegration is likely with all types. Implant design, material, and submergibility do not appear to be essential for initial osseointegration to occur as long as a biocompatible material is selected and the implant is placed using minimally traumatic surgical techniques.

Aluminum Oxide

Transmission electron microscopic and high voltage electron microscopic observations of the bone and osteocyte activity adjacent to unloaded dental implants placed in dogs.

The purpose of this report is to describe ultrastructural observations of the bone and associated tissues supporting 24 unloaded endosteal dental implants placed in mongrel dogs (canis familiaris). The following 3 specific areas of the supporting tissues were targeted: 1) the osteocyte populations; 2) the mineralized collagen fiber matrix of the bone; and 3) an electron dense interfacial deposit. To investigate these areas, transmission electron microscopy and high voltage electron microscopic (HVEM) protocols were emphasized. HVEM permitted stereologic observations. Further, all observations were obtained from undecalcified tissues obtained from animals with commercially available implants placed into the mandible. From the study we observed a mineralization pattern of the implant supporting bone that was similar to those events occurring naturally within the mandibular bone. Osteocyte morphology was similar whether the osteocytes were found well below the implant interface or close to the interface. Osteocytes within lacunae were routinely found close to the implant interface, often extending cellular processes through canaliculi to the bone-implant interface. At the interface, an electron dense deposit approximately 50 nm in thickness was often observed. In interfacial regions, densely mineralized collagen fibers were observed running primarily parallel to the implant surface. This dense mineralized tissue was separated from the interface by a mineralized, but finely fibrillar matrix of approximately 200 nm in thickness.

Animals

Correlative transmission electron microscopic and scanning electron microscopic observations of the tissues supporting endosteal blade implants.

Correlated scanning electron microscopic (SEM), routine transmission electron microscopic (TEM), and high-voltage transmission electron microscopic (HVEM) observations demonstrated that one-stage and two-stage endosteal blade-type implants were well-supported by mandibular tissues after five months of unloaded healing in dogs. Areas of the implants were apposed directly by mineralized tissues without any apparent interposed unmineralized connective tissue. Other areas of the implants were apposed by narrow areas of unmineralized tissue, often containing osteoblasts. These unmineralized areas were interposed between the implant and a supporting mineralized matrix. A healthy mix of tissues, which represented a dynamic osseous complex, supported these serviceable blade-type dental implants. This study, for the first time in the dental implant literature, utilizes HVEM stereology for evaluation of the bone-implant interface.

Alveolar Process

Simulated implant surgery in rabbit long bones: a descriptive study.

The objectives of this study were: (a) to observe and describe the variability of bone healing in implant receptor sites which were prepared in rabbit femurs by use of different surgical methods; and (b) to determine if the animal model which was used was suitable for the detection of differences in healing reactions in implant receptor sites which were prepared by different surgical methods. Three 3-mm-wide implant receptor sites were prepared in the right and left femurs of four large New Zealand white rabbits. The surgical parameters used in preparation of the different sites included: low speed with no irrigation (LSO); low speed with internal irrigation only (LSI); low speed with external irrigation only (LSE); high speed with no irrigation (HSO); or high speed with external irrigation only (HSE). The sites were randomized so that each animal had one of each type of site in either the right or left femur. A non-treated control site was located in each animal for comparison with experimental sites. The animals were killed at 7, 14, 21, and 28 days post-operatively. The resultant samples were fixed, embedded, sectioned, and stained with basic fuchsin and toluidine blue. The results indicated that this was probably not a suitable animal model, since no discernible differences were detected in the various healed sites.

Animals

Electron microscopy of bone response to titanium cylindrical screw-type endosseous dental implants.

This study investigated the undecalcified bone and enveloping tissues supporting commercially pure titanium one-stage and two-stage endosseous dental implants placed into the mandibles of adult mongrel dogs. Correlative light microscopy, transmission electron microscopy, and high-voltage transmission electron microscopy demonstrated a dynamic bone interface to the implants. Mineralized tissue was routinely observed within 20 to 50 nm from the implant interface, separated from the implant interface only by an electron-dense deposit. The densely mineralized collagen fiber matrix was oriented parallel to the implant interface, as were osteocytes that were found close to the interface. Osteocytic projections progressed through canaliculi, often directly to the implant interface. Unmineralized areas that appeared to have the potential for mineralization were also identified.

Alveolar Process

Comparative implant research in dogs: prosthodontic protocol using two-stage ceramic endosseous dental implants.

This report describes one phase of a long-term comparative implant investigation involving 20 of 120 endosseous implants placed in 30 adult mongrel dogs. Fixed prostheses involving 16 of the 20 (4 control implants) two-stage ceramic endosseous implants have been provided using routine prosthodontic procedures and the limited prosthetic components available for the Bioceram Series II implant system. The prostheses have proven to be functional with minimal maintenance. To date, after 1 year of follow-up, 2 of the two-stage implants have exhibited problems caused by fracture of the hexagonal collar. None of the implants to date has been lost and none of the fixed prostheses has required re-cementation or any other type of maintenance other than normal hygiene. Clinical evaluation suggests continued implant and prosthesis serviceability after 1 year in function.

Aluminum Oxide

Secondary structure of human interleukin-3.

1. The secondary structure of human interleuken-3 in solution was determined by circular dichroism spectroscopy. 2. The results were then compared with empirical secondary structure predictions based on primary sequence structure of the protein. 3. The two approaches are in extremently close agreement showing the protein to have 40% alpha-helix, 12% total beta-structure and 48% random coil content.

Amino Acid Sequence

Dental implants retrieved from humans: a diagnostic light microscopic review of the findings in seven cases of failure.

With the increased use of dental implant systems, an increase in the number of implants removed from patients has also been observed. This investigation attempted to elucidate some underlying causal determinants of implant failure employing light microscopic analyses. Valuable data can be obtained from implants retrieved from patients. Implant success is predicted on proper patient selection and treatment planning, careful surgical procedures, careful prosthodontic management, and continued oral hygiene maintenance.

Aged

Using a tooth-reduction guide for modifying natural teeth.

A simplified method of transferring diagnostic odontoplastic information from the cast to the patient is described. This technique can be used successfully when treating fixed, removable, or combination prosthodontics patients.

Acrylic Resins