PubMed Health⌕ Search

Biomedical subjects

G Rábago

Publications and source records attributed to G Rábago.

At least 37 records · Page 2Linked to original sources

[Heart myxoma. Surgical treatment].

We reviewed all the patients who underwent surgical excision of cardiac myxomas at La Pitié during the last fifteen years. Fifty-one cases were found (32 female and 19 male) aging from 16 to 75 years (mean 51). Congestive heart failure was the primary symptom present in 28 patients. Thirteen patients presented peripheral embolization, four with syncope and 11 with tachyarrhythmias. The diagnosis was made either by echocardiography or angiography. All of them had correct preoperative diagnoses, and no tumors were found incidentally at operation. Forty-six myxomas were localized in the left atrium, four in the right atrium and one in the right ventricle. All the patients underwent open-heart operation and myxomas were successfully removed with excision of a portion of normal atrial septum or wall. Path reconstruction of the atrial septum was required thirty-six times. Mortality after surgical excision is very low. Only one death (1.96%) occurred as a result of a postoperative low output syndrome. Late recurrences have been reported in other series, but no recurrences were diagnosed in our patients up to the present. Although the recurrence rate is low, long-term clinical and echocardiographic follow-up is recommended.

Adolescent↗

Reoperations for left-sided low-profile mechanical prosthetic obstructions.

A series of 2,474 hospital survivors of primary mitral, aortic, and double mitral-aortic valve replacement were observed for a cumulative period of 11.945 years (mean, 4.2 years; range, 0.6-14 years). The linearized incidences of reoperations for thrombotic obstructions were 0.33 +/- 0.08% for mitral valve replacement, 0.36 +/- 0.1% for aortic valve replacement, and 0.42 +/- 0.1% for double valve replacement (p = not significant). Forty-one patients (16 mitral, 12 aortic, and 13 double valve replacements) underwent a total of 44 reoperations with a mean interval of 36 +/- 29 months (range, 0.25-85 months) between operations. Diagnosis was established invasively only in 13 patients (30%). Hospital mortality at reoperation was 18% (8 patients); 28 patients (63%) required emergency surgery. The choice surgical procedures were thrombectomy for clotted aortic prostheses (18 of 24) and valve replacement for obstructed mitral valves (22 of 25; p less than .001). Rethrombosis occurred in 3 patients (1 aortic and 2 double valve replacements). At hospital admission 17 patients (38%) had prothrombin times outside therapeutic ranges (between 20 to 30% of the normal value). The incidence of reoperations for thrombosis in low-profile mechanical prostheses was unaffected by valvar position and number of prostheses implanted. Rethrombosis occurred only in previously cleaned valves, although its occurrence was not significant. The present results indicate that, as experience is gained in the diagnosis and surgical management of this complication, hospital mortality can be reduced significantly (from 37% to 4%).

Aortic Valve↗

Comparative clinical results with Omniscience (STM1), Medtronic-Hall, and Björk-Shiley convexo-concave (70 degrees) prostheses in mitral valve replacement.

The intermediate clinical results of 289 patients undergoing isolated mitral valve replacement with three different low-profile mechanical prostheses have been retrospectively analyzed and compared. Between June, 1980, and September, 1983, 70 patients received the Omniscience prosthesis, 159 patients the Medtronic-Hall valve, and 60 patients the convexo-concave 70 degree Björk-Shiley prosthesis. Hospital mortality was 15% for the Björk-Shiley group, 4.4% for the Medtronic-Hall group, and 7.1% for the Omniscience group. Cumulative follow-up was 88 years (mean 1.7 years) for the Björk-Shiley, 229 years (mean 1.5 years) for the Medtronic-Hall, and 223 years (mean 3.3 years) for the Omniscience group. All patients were placed on a program of anticoagulant therapy (dicumarol) postoperatively. Actuarial survival rates (+/-SE) 2 years postoperatively were comparable for the three groups: Björk-Shiley, 90% +/- 4.7%; Medtronic-Hall, 93% +/- 2.2%; and Omniscience, 88% +/- 4.1% (p = NS). Late mortality, expressed at linearized rates (percent patient-year +/-SE), was 3.4% +/- 1.9% for the Björk-Shiley group, 1.7% +/- 0.8% for the Medtronic-Hall group, and 3.6% +/- 1.2% for the Omniscience group (p = NS). Actuarially determined rates of freedom from thromboembolic complications (systemic embolism and valvular thrombosis) 2 years postoperatively were 97% +/- 2.2% for the Björk-Shiley group, 94% +/- 2.1% for the Medtronic-Hall, and 84% +/- 4.7% for the Omniscience group (p = 0.05, Omniscience versus Medtronic-Hall; p = 0.02, Omniscience versus Björk-Shiley) The actuarial probability of being free from reoperation 2 years postoperatively was 92 +/- 3.5 for the Björk-Shiley group, 92 +/- 2.9 for the Medtronic-Hall group, and 82 +/- 3.9 for the Omniscience group (p = 0.04). The major cause for reoperation in the Omniscience group was valve thrombosis (seven patients), yielding a linearized incidence (+/-SE) of 3.1 +/- 1.1 (p = 0.01). No statistically significant differences were obtained regarding the incidence of prosthetic infective endocarditis or perivalvular leak. Overall rates of anticoagulant-related hemorrhage were comparable for the three groups.

Actuarial Analysis↗

Long-term comparative analysis of the Björk-Shiley and Hancock valves implanted in 1975.

The long-term results in all patients undergoing isolated mitral, aortic, or double mitral-aortic heart valve replacement operated upon in 1975 has been retrospectively analyzed. A total of 153 patients received the standard Björk-Shiley (flat pyrolytic disc) mechanical prostheses and 150 patients received the noncomposite Hancock porcine xenograft. Overall operative mortality was not significantly different between groups. All patients receiving a Björk-Shiley prosthesis, but none in the Hancock group, received long-term anticoagulant therapy. Medium and long-term actuarial survival rates (5 and 10 years postoperatively) were comparable for the two groups (88% for Björk-Shiley and 84% for Hancock [NS] at 5 years; 86% for Björk-Shiley and 80% for Hancock at 10 years [NS]). The incidence of systemic embolism was similar in the two groups (1.6% +/- 0.4% per patient-year for the Björk-Shiley group and 1.3% +/- 0.3% per patient-year for the Hancock group [NS]). Also the incidence of endocarditis was similar (0.6% +/- 0.2% per patient-year for the Björk-Shiley group and 0.8% +/- 0.3% per patient-year for the Hancock group [NS]). In the Hancock group the overall incidence of reoperations was significantly higher than in the Björk-Shiley group (4.2% +/- 0.6% per patient-year versus 0.9% +/- 0.3% per patient-year (p = 0.001). The major cause for reoperation in the Hancock group was primary tissue failure (3% +/- 0.5% per patient-year). In the Björk-Shiley group the major cause of reoperation was valve thrombosis (0.5% +/- 0.2% per patient-year). Therefore, accepting the fact that other bioprostheses may behave differently from the Hancock noncomposite xenograft, we currently restrict our indications for valve replacement with bioprostheses.

Actuarial Analysis↗

Relation of midwall circumferential systolic stress to equatorial midwall fibre shortening in chronic aortic regurgitation. Value as a predictor of postoperative outcome.

Nineteen patients with chronic aortic regurgitation and a large increase in heart size were studied before aortic valve replacement. By relating midwall circumferential systolic stress to midwall circumferential fibre shortening (Cs/Cd) before operation the patients could be divided into two well defined groups. Twelve patients (group 1) had a pronounced decrease in heart size as measured by the cardiothoracic ratio and an excellent clinical outcome six months after operation. Seven patients (group 2) had no significant decrease in heart size and a less good clinical outcome. The ratio of midwall circumferential systolic stress to end systolic volume index was significantly higher in group 1 than in group 2. Group 2 had more severe left ventricular hypertrophy determined by the ratio of the wall thickness to the minor internal radius of the left ventricle (h:r ratio), total left ventricular mass, and left ventricular mass to end diastolic volume ratio. There were no significant differences in any other haemodynamic or angiographic indices between the two groups. Thus the relation of midwall circumferential systolic stress to fibre shortening is useful in determining the prognosis in individual patients with chronic aortic regurgitation undergoing aortic valve replacement.

Adult↗

Results and complications with the Omniscience prosthesis.

A clinical trial with the Omniscience heart valve was conducted from June, 1980, until May, 1981. In this period 166 patients underwent heart valve replacement: mitral valve replacement (MVR) 70 patients, aortic valve replacement (AVR) 37, and combined mitral-aortic valve replacement (M/AVR) 59 patients. There were 20 hospital deaths, for a mortality of 12%. Total follow-up was 226 patient-years (range 6 to 28 months, mean 18 months). There were eight late deaths (MVR 4.6%, AVR 3.1%, and M/AVR 8.1%). All patients were taking oral anticoagulants. The incidence of valve-related complications (expressed as events per 100 patient-years) was as follows: Systemic embolism--MVR 2, AVR 4.7, and M/AVR 2.5; and anticoagulant complications--MVR 1.9, AVR 2.3, and M/AVR 0. The incidence of valvular dysfunction (expressed as events per 100 patient-years) was as follows: valvular thrombosis--MVR 4.8, AVR 0, and M/AVR 1.2; perivalvular leakage--MVR 1.9, AVR 2.3, and M/AVR 2.5; and infective endocarditis--MVR 0.96, AVR 0, and M/AVR 1.2. The actuarial probability of being free of valvular dysfunction 30 months postoperatively is 73% for the MVR group, 90% for the AVR group, and 71% for the M/AVR group. Despite a short follow-up, the incidence of valvular dysfunction has been significant. For this reason, we have discontinued using these prostheses for heart valve replacement.

Aortic Valve↗

Early surgical results of the Medtronic-Hall valve.

A clinical trial with the Medtronic-Hall (M-H) valve was started in November 1981. From then until December 1982, 157 patients underwent heart valve replacement: Mitral valve replacement (MVR) 63 patients, isolated aortic valve replacement (MVR) 41 patients, and 53 underwent combined mitral-aortic valve replacement (MVR + AVR). Hospital mortality was 2.5% overall (4/157). The total follow-up was 147 patient-years (range 1 to 12 months). Late mortality was 3.2% for MVR, 2.5% for AVR and 1.9% for double MVR + AVR. Oral anticoagulation therapy (Dicumarol) was administered to all patients included in this study. There were no anticoagulant complications and no prosthetic bacterial endocarditis registered in this series of patients up to date. The incidence of systemic embolism was 2.5 events per 100 patient-years in the AVR group. No embolic episodes have been registered in the other 2 groups. The incidence of valvular dysfunction (expressed as events per 100 patient-years) were: --Perivalvular leak (0 MVR, 0 AVR and 2 MVR + AVR) --Valve thrombosis (1.7 MVR, 0 AVR and 0 MVR + AVR) --Mechanical dysfunction (1.7 MVR, 0 AVR and 0 MVR + AVR) Despite a short follow-up, the results with the Medtronic-Hall valve are encouraging and compare favorably with other mechanical prostheses.

Adult↗

Thrombotic obstruction of the Björk-Shiley aortic valve prosthesis. Report of four cases.

We present four cases of late thrombotic obstruction of the Björk-Shiley aortic valve prosthesis. The incidence of this complication reported in the literature to vary from 0.7% to 5%. In our experience of a total of 623 Björk-Shiley aortic valve replacements, we observed this complication in only 4 patients (0.6%). Two of them had poorly controlled anticoagulation therapy. The clinical presentation was subacute in all four patients. Surgical treatment, thrombectomy and debridement, was performed in all of them. The diagnosis was made upon abrupt and progressive onset of dyspnoea, physical examination data and echocardiographic and radioscopic findings. Angiocardiographic studies were needed in two patients.

Adult↗

[Results of surgery for mitral valve stenosis].

Long-term follow-up of 1806 patients si subjected to mitral commisurotomy and 122 fitted with a prosthesis for stenosis is described. Of those operated by means of the closed technique, 70% were in functional stage I or II after 10 yr (55% after 15 yr). It would seem from these results that surgery has an important effect on the natural history of mitral stenosis when treated solely medically.

Evaluation Studies as Topic↗

Thrombotic obstruction of Bjork-Shiley tricuspid valve prosthesis. Report of three cases reoperated with success.

Three patients presented subacute right heart failure, 6, 12 and 22 months after replacement of the tricuspid valve with a Björk-Shiley prosthesis. The principal finding encountered on clinical examination was a tricuspid filling murmur with inspiratory accentuation. The mean prosthetic gradient found at cardiac catheterization was 7, 8 and 10 mm Hg. At surgery, the three prostheses were thrombosed on their ventricular aspect and all the three were replaced with new ones of the same model. The patients are alive and in good condition, 21, 17 and 8 months after the operation. Problems which relate to the surgical management of tricuspid valve disease are discussed.

Adult↗

[Peripheral thromboembolic complications in heart transplantation: prevalence and review of the literature].

Peripheral thrombotic complications were retrospectively analyzed in a series of 164 consecutive patients undergoing orthotopic cardiac transplantation (CT) at the University Clinic of Navarra from 1984 to 1999. The overall survival during the first year after CT was 82%. All patients, besides the immunosuppressive regimen, received antiplatelet treatment postoperatively. The prevalence of thrombotic complications was 18% (29 events in 25 patients): 21 (13%) corresponded to arterial thrombosis, mainly cerebrovascular, whereas 8 (5%) were venous thrombosis. The time between the CT and the onset of thrombosis was 2 +/- 1.8 years. Mortality in patients with thrombosis did not differ significantly from the global mortality. The analysis in relation to the presence of cardiovascular risk factors only showed statistical significant differences for the age (older in the group with thrombosis, p = 0.02). In conclusion, there is a high prevalence of peripheral thrombotic complications in patients undergoing CT despite the antithrombotic regimen administered. The lack of correlation with the traditional cardiovascular risk factors suggest additional mechanisms for thrombosis in these patients.

Adolescent↗

[Advances in cardiac surgery].

The development of cardiovascular surgery has been accompanied by a series of advances in complementary technology, which has made it possible to carry out safer and less aggressive surgery. In this article there is a review of the latest progress in coronary and valvular surgery, cardiac insufficiency, arrhythmia and the application of extracorporeal circulation in non-cardiac diseases. These advances can serve as the starting point in order to build a future adapted to the needs generated by both patient and disease.

Cardiac Surgical Procedures↗