PubMed Health⌕ Search

Biomedical subjects

G Rau

Publications and source records attributed to G Rau.

At least 19 recordsLinked to original sources

Movement analysis in the early detection of newborns at risk for developing spasticity due to infantile cerebral palsy.

In order to limit the consequences of infantile cerebral palsy (ICP), physiotherapy should start as early as possible. This requires that infants at risk are detected at the earliest age possible. Today, diagnosis is based on visual observation by physicians and as such is influenced by subjective impressions. Objective methods, quantifying the pathological deviation from normal spontaneous motor activity would be preferable as they, for example, allow an inter- and intra-individual comparison of movement. In this paper we have developed a methodology that allows the 3-dimensional acquisition of unconstrained movement in newborn babies, using a motion analysis system. From the recorded movement data we have extracted 53 quantitative parameters that describe the differences between healthy and affected participants. Considered individually, each of these parameters does not permit a conclusive statement to be made as to whether or not the patient is at risk. Cluster analysis based on Euclidian distances therefore has been used to find an optimal combination of eight parameters. The optimal combination has been subsequently applied to organize the participants' movement into preferably homogeneous classes labelled "healthy" or "at risk". Classification was performed utilising quadratic discriminant analysis. The methodology presented allows a reliable discrimination between healthy and affected participants. Overall detection rate reached 73%. This value is expected to rise with increasing patient and norm collective database size.

Cerebral Palsy↗

Comparison of the electromyographic activity in the upper trapezius and biceps brachii muscle in subjects with muscular disorders: a pilot study.

The aim of the present study was to investigate the extent to which work-related muscular disorders of the upper trapezius affect the activity of other pain-free muscles, in particular in the biceps brachii. Two groups of female subjects (age >43 years) participated in the study: seven affected subjects with self-reported disorders in the shoulder/neck region (cases) and nine healthy subjects (control group). Multi-channel electromyography (EMG) and force were recorded during maximum voluntary contractions (MVC) and during 6 min sustained contractions (at 30% MVC) of the upper trapezius and biceps brachii on the dominant side. From the EMG signals, the root mean square (RMS), median frequency (MDF) and single motor unit (MU) conduction velocity (CV) were estimated. From the force signal, the coefficient of variation was calculated. All data are presented as mean values and standard deviation. Differences between the cases and controls were found in the MVC force of the upper trapezius, which was lower in cases [253 (70) N] than in controls [357 (75) N], while the coefficient of variation of force during the sustained contraction was increased [cases 5.5 (2.2); controls 4.1 (1.9)]. The RMS (normalized to the RMS at MVC) during the 6 min sustained contractions was significantly lower in the cases than in the controls for both the upper trapezius and the biceps brachii. A tendency towards a smaller increase in the RMS with fatigue was only found in the trapezius muscle [slope: cases 6.5 (14.1) %/min, controls 10.2 (12.9) %/min]. No differences were found between the two subject groups with respect to the MDF and single MU CV in both muscles. While the lower RMS for the trapezius muscles of the cases may reflect changes at the local level, as well as in motor control, the lower biceps activity indicates a change in the central control strategies of the primarily unaffected muscle. Indications for a changed fatigability of the muscle were only found in the trapezius.

Case-Control Studies↗

Design and in vitro performance of a novel bileaflet mechanical heart valve prosthesis.

Design and in vitro performance of a novel bileaflet mechanical heart valve prosthesis are presented. The novel heart valve exhibits three main design characteristics: (i) The leaflets form a Venturi passage in open position. Thus, a beneficial pressure distribution is obtained and the leaflets are stabilised in opened position. (ii) The orifice inlet is nozzle-shaped. Flow is convectively accelerated and flow separation at the orifice inlet is avoided. (iii) The hinge design facilitates an additional axial movement of the leaflets and leads to a self cleaning effect and enhances washout of the hinges. The design of the leaflet hinges is of main importance for the functional reliability and durability of mechanical heart valves. After manufacturing first prototypes from titanium and polymeric materials the hydrodynamic performance was evaluated according to ISO 5840 and FDA guidelines. Hydrodynamic performance is comparable with the results of commonly available bileaflet mechanical heart valve prostheses. Initial durability tests showed suitable material couples for further long term studies.

Biocompatible Materials↗

Estimation of the muscle fibre semi-length under varying joint positions on the basis of non-invasively extracted motor unit action potentials.

Changes in muscle fibre length and surface electrode position with respect to the muscle fibres affect the amplitude and frequency characteristics of surface electromyography (SEMG) in different ways. Knowledge of changes in muscle fibre length would help towards a better interpretation of the signals. The possibility of estimating the length through SEMG during voluntary contractions was checked in this study. The fibres' semi-length was estimated from the product of the conduction velocity and conduction time during which the wave of excitation propagated from the end-plate region to the ends of the fibres. Short (10 s), moderate (30% of maximum voluntary contraction) isometric contractions were performed by 10 subjects at different elbow joint angles (80-140 degrees in steps of 20 degrees ). Monopolar signals were detected non-invasively, using a two-dimensional electrode array. High spatial resolution EMG and a decomposition technique were utilised to extract single motor unit activities for triggered averaging and to estimate conduction velocity. A significant increase with joint angle was found in conduction time and estimated fibre semi-length. Changes in conduction velocity with joint angle were found to be not significant. The methodology described allows the relative changes in fibres' semi-length to be estimated from SEMG data.

Action Potentials↗

Upper trapezius muscle conduction velocity during fatigue in subjects with and without work-related muscular disorders: a non-invasive high spatial resolution approach.

The development of fatigue at the muscle fibre level can be assessed in terms of a decrease in conduction velocity (CV). The present study aimed to investigate if work-related muscular disorders in occupations characterised by static loads of long duration affect fatigue resistance in the painful muscle. A group of eight secretaries suffering from bilateral chronic muscle pain in the shoulder/neck region was compared to a group of healthy subjects. The upper trapezius muscle was studied under isometric contractions, holding the arm in the horizontal plane up to the endurance point. Changes in CV estimated at the motor unit level were investigated using a non-invasive high spatial resolution electromyographic (EMG) approach. In addition, the number of motor unit potentials per second (PPS), and the root mean square (RMS) of bipolar signals were assessed, and the results reported as the mean and standard error for each value. Subjects with work-related disorders showed less pronounced changes in CV with respect to healthy subjects. No differences between subjects with and without work-related disorders were encountered for the PPS and RMS. The present findings on CV indicate an increased fatigue-related recruitment of MUs in the painful muscle with respect to a healthy muscle. The fact that this recruitment is not reflected in the PPS and RMS estimates might be due to a fatigue-induced decrease in the firing rate and/or the de-recruitment of fatigued MUs. Furthermore, methodological limitations of the adopted method in the estimation of 'global' parameters such as the PPS and RMS have to be considered.

Adult↗

Influence of muscle fibre shortening on estimates of conduction velocity and spectral frequencies from surface electromyographic signals.

The study of surface electromyographic (EMG) signals under dynamic contractions is becoming increasingly important. However, knowledge of the methodological issues that may affect such analysis is still limited. The aim of the study was to analyse the effect of fibre shortening on estimates of conduction velocity (CV) and mean power spectral frequency (MNF) from surface EMG signals. Single fibre action potentials were simulated, as detected by commonly used spatial filters, for different fibre lengths. No physiological modifications were included with changes in fibre length, and thus only geometrical artifacts related to fibre shortening were investigated. The simulation results showed that the dependence of CV and MNF on fibre shortening is affected by the fibre location, electrode position and the spatial filter applied. With shortening of up to 50% for a fibre of 50 mm semi-length, the variations in CV and MNF estimates with shortening in bipolar recordings were 0.5% (CV) and 0.7% (MNF) for superficial fibres, and 3.6% and 5.1% for deeper fibres. Using the longitudinal double differential filter, under the same conditions, the percent variation was 0% and 0.2%, and 24.7% and 15.8%, respectively. The main conclusions were, first, muscle fibre shortening can significantly affect estimates of CV and MNF, especially for short fibre lengths. However, for long (semi-length >50 mm) and superficial fibres, this effect is limited for shortenings of up to 50% of the initial fibre length. Secondly, CV and MNF are almost equally affected by changes in muscle length; and, thirdly, sensitivity to fibre shortening depends on the spatial filter applied for signal detection.

Electrodes↗

Experimental muscle pain increases trapezius muscle activity during sustained isometric contractions of arm muscles.

OBJECTIVE: In the present study, the influence of experimental muscle pain on muscle co-ordination and fatigue development during sustained isometric elbow flexion was investigated. METHODS: Conventional surface electromyography (EMG) was recorded from the biceps brachii, brachioradialis, deltoideus and trapezius muscle during isometric elbow flexion at 40% maximum force. Single motor unit (MU) conduction velocity in the biceps brachii was assessed using a high spatial resolution surface EMG technique. Measurements were performed on 15 healthy subjects before, during and after (1) injection of hypertonic (pain condition) and (2) isotonic saline (control) into the biceps brachii. The pain intensity was assessed on a 10 cm visual analogue scale. RESULTS: The experimental results showed in both experimental sessions a fatigue-related increase of the root mean square value of EMG (222+/-164% of the baseline), and a decrease of the median frequency (118+/-16% of the baseline) in all investigated muscles. A maximum pain level of in average 3.2 cm on the visual analogue scale was reached after injection of hypertonic saline during contraction. Differences between painful and control condition were seen in an increased trapezius activity (230+/-141%) during pain. The global EMG activity of the brachioradialis and biceps brachii was unaffected by experimental muscle pain in line with unaffected single MU conduction velocity in the biceps brachii. Differences in endurance time (mean 89.3 and 102.3 s, pain and control, respectively) were not significant. CONCLUSIONS/SIGNIFICANCE: The findings suggest that upper extremity pain could be a possible source for overloading the trapezius muscle and as such is an important factor in occupational settings.

Adult↗

From cell to movement: to what answers does EMG really contribute?

This paper aims to address some of the possibilities and limitations of EMG technologies available to date. Considerable progress has been achieved in this field during the last 30 years and EMG signals can be easily obtained on different levels beginning at the cell membrane and ending with the global EMG associated with the movement itself. Different aspects from cell to movement have been considered in this paper. Highly selective needle EMG for the detection of the processes at the membrane is discussed as well as high spatial resolution EMG which gives non-invasive access to the acquisition of the single motor unit activity. On the highest level of muscles, an expert system is introduced as a novel approach to support the interpretation of muscular co-ordination as detected by conventional surface EMG. While there is a high potential in the newly developed EMG methodologies, it is a big challenge to utilize these methodologies in order to obtain detailed, repeatable, reliable--and meaningful--results. However, the risk of over- and misinterpretation has to be carefully considered. In this paper, this risk is exemplified in situations dealing with muscle fatigue, conduction velocity and cross-talk. Despite all the new possibilities available, the authors recommend that EMG with its inherent strengths and limitations should still be diligently, but carefully, used.

Action Potentials↗

Single motor unit analysis from spatially filtered surface electromyogram signals. Part I: spatial selectivity.

The aim of the study was to compare experimentally, on the basis of single motor unit (MU) activities, the selectivity of different spatial filters commonly used to detect surface electromyogram (EMG) signals. Surface EMG signals were recorded from the biceps brachii and the upper trapezius muscle of five subjects using a two-dimensional (2D) electrode array consisting of 16 pin electrodes. The subjects performed isometric contractions at different elbow angles and shoulder abduction and flexion. The same monopolar surface EMG signals were filtered using longitudinal single and double differential, transverse single and double differential and normal double differential filters. From the single MU action potentials, extracted by automatic EMG decomposition, indexes of transverse (perpendicular with respect to the fibre direction) and longitudinal (along the fibre direction) selectivity were computed. The number of detected MUs was 46 for the upper trapezius, with the arms held in the sagittal plane, and 52 when the arms were held in the frontal plane; 85 MUs were identified from the biceps brachii contractions. The results showed that transverse selectivity was significantly higher for the 2D and transverse one-dimensional (1D) filters with respect to the 1D longitudinal filters, whereas longitudinal selectivity was higher (i.e. MU action potentials were shorter) for the 2D filter and the longitudinal double differential filter. In particular, the relative attenuation of potential amplitude moving 5 mm from the source was, on average (for the two muscles), 16.5% for the least selective filter in the transverse direction (longitudinal single differential) and 35.7% for the most selective one in the same direction (transverse double differential). The MU action potential duration was, on average, 13.8 ms for the most selective filter in the longitudinal direction (longitudinal double differential) and 18.7 ms for the least selective one (transverse double differential). The normal double differential filter resulted in spatial selectivity indexes that ware not statistically different in the two directions from those of the best filters in each direction.

Action Potentials↗

Single motor unit analysis from spatially filtered surface electromyogram signals. Part 2: conduction velocity estimation.

The aim of the study was to compare experimentally conduction velocity (CV) estimates obtained with different estimation methods based on surface electromyogram (EMG) signals detected using five spatial filters. The filters investigated were the longitudinal single and double differential, transverse single and double differential, and normal double differential. The same surface EMG signals detected as described in Part 1 were used in this work. CV was estimated with four commonly used delay estimation techniques, i.e. from the distance between the peak values of two waveforms (with and without polynomial interpolation around the peak), and by the maximum likelihood estimate (MLE) based on two or more surface EMG channels. The average standard deviation of CV estimation (for all the MUs and the two muscles together) was 0.61 m s(-1) and 0.79 m s(-1) for the peak method, with and without interpolation, respectively, and 0.50 m s(-1) and 0.31 m s(-1) for the MLE method, from two and more surface EMG channels, respectively. Moreover, the mean of CV estimates varied by as much as 1 m s(-1) depending on the spatial filter used and the method adopted for CV estimation. Considering the dependence on the spatial filter only, the average (over all estimation methods) CV estimates obtained with the five spatial filters were 4.32 m s(-1) (normal double differential), 4.23 m s(-1) (longitudinal double differential), 4.61 m s(-1) (transverse double differential), 4.64 m s(-1) (transverse single differential) and 4.03 m s(-1) (longitudinal single differential). It was concluded that the comparison of single MU CV values obtained in different studies is critical if different spatial filters and processing techniques are used for their estimation. Higher estimates of CV were attributed to a smaller reduction in non-travelling signal components and thus were assumed to be positively biased.

Action Potentials↗

Preadipocyte-loaded collagen scaffolds with enlarged pore size for improved soft tissue engineering.

Extended soft tissue defects after extensive deep burns or tumor resections are still an unresolved problem in plastic and reconstructive surgery. There is a clinical need for an adequate solution to this problem but currently, no adequate implant material is available for the correction of these defects. Since the autologous transplantation of mature adipose tissue gives poor results, this study explores the advantages of using human preadipocytes in collagen sponges for tissue reconstruction purposes. Human preadipocytes of young adults were isolated, cultured, seeded onto collagen sponges with uniform pore size, and implanted into immunodeficient mice. After 24 hours of incubation in vitro and after explantation at 3, 8, and 12 weeks, sponges were examined for macroscopic appearance, weight, thickness, histology, immuno-histochemistry, and ultrastructure. We find good penetration of cells into the scaffold, layers of adipose tissue, and new vessels on all grafts while controls appear unchanged. These results are promising for improving the reconstruction of soft tissue defects.

Adipocytes↗

Effect of hemolysis on oxygen and hematocrit measurements by near infrared reflectance spectroscopy.

A short review of the principles of near infrared reflectance spectroscopy (NIRS) in whole blood is followed by a discussion on the influence of hemolysis. The increase of free plasmahemoglobin (PHb) has a strong influence on the continuous measurement of hematocrit and oxygen saturation (O(2)S) by NIRS. In view of the relative stability of hematocrit values in vivo this effect may be used to detect a change of the hemolysis rate induced by blood pumps in case of malfunction. The aim of this study is, therefore, the assessment of the hemolysis rate within an in vitro mock loop comprising a rotary blood pump by means of NIRS at constant hematocrit levels compared to the photometric reference method. Reflected light is measured by an integrated optical sensor working at three wavelengths (660 nm, 730 nm, and 830 nm). The experimental results demonstrate that the increase of free hemoglobin in plasma due to mechanical pumping leads to a decrease of detected reflected light at all three wavelengths. Influencing parameters such as adhering proteins on the sensor surface and the blood flow rate are briefly discussed. Finally, the possibility of using NIRS sensors for detecting malfunctions of blood pumps in vitro and in vivo is discussed, together with the option of using these sensors for supervision of long-term implantable pumps.

Biosensing Techniques↗

Magnification of the pore size in biodegradable collagen sponges.

In tissue engineering cells are often combined with a carrying structure with collagen being a suitable material to form a 3D-scaffold. A process to manufacture collagen sponges with an adjustable and homogeneous structure has been developed at the Helmholtz-Institute. Using this process, collagen suspensions are frozen directionally and subsequently vacuum-dried. One clinical application in which these scaffolds can be used is soft tissue reconstruction. Various soft tissue defects require an adequate replacement, e.g. in the case of severe burn wounds, or after tumour resections. Collagen (type I) sponges, which are cultured with preadipocytes, may be used to regenerate such defects. In this case, pore sizes of approximately 100 microm are desired to allow a complete differentiation of preadipocytes into adipocytes. Based on known technology to manufacture collagen sponges with an adjustable and homogeneous pore structure, research on the increase of pore size beyond the previous limit of 40 microm was necessary in order to enable soft tissue replacement. A scaffold with an average pore size of 100 microm was obtained.

Adipocytes↗

A new rotary blood pump for versatile extracorporeal circulation: the DeltaStream.

Today, rotary pumps are routinely used for extracorporeal circulation in different clinical settings and applications. A review of these applications and specific limitations in extracorporeal perfusion was performed and served as a basis for the development of the DeltaStream. The DeltaStreams is a miniaturized rotary blood pump of a new and unique design with an integrated drive unit. Despite its small design, the pump maintains a sufficient hydraulic capacity, which makes the DeltaStream very flexible for intra- and perioperative applications. It also opens the field for short-term ventricular assist devices (VAD) applications or use as a component in extracorporeal life support systems (ECLS). The DeltaStream and, specifically, its impeller design have been optimized with respect to haemolysis and nonthrombogenicity. Also, the pump facilitates an effective pulse generation in VAD applications and simulates heart action in a more physiological way than other rotary pumps or roller pumps. Hydraulic and haematological properties have been tested in vitro and in vivo. In a series of seven animal experiments in two different setups, the pump demonstrated its biocompatibility and applicability. Basic aspects of the DeltaStream pump concept as well as important console features are presented. A summary of the final investigation of this pump is given with focus on hydraulic capabilities and results from animal studies.

Animals↗

Thermophysical properties of a monolayer tissue with respect to freeze-drying.

Conservation of tissue structures by means of freeze-drying is still limited as the complex mechanisms taking place at molecular/cellular level are not fully understood. The successful application of hydroxyethyl starch (HES) in combination with maltose, sucrose, and trehalose as stabilizers of lipid bilayers/membranes in red blood cells suggests an extended use of this mixture of cryoprotectants. The effectiveness of such cryoprotectant solutions has been linked to changes in the thermophysical properties of cellular structures. This work deals, in a first step, with the thermophysical properties of a model monolayer tissue--onion epidermis--in binary aqueous solutions of dissacharides. First and second order phase transitions, i.e. melting, crystallisation, and glass transition, are characterised by means of Modulated Differential Scanning Calorimetry (MDSC).

Cryoprotective Agents↗

Preparation of collagen scaffolds and their applications in tissue engineering.

Freeze-dried collagen scaffolds can be used for a variety of medical tissue engineering applications. The pore structure of the scaffolds might play a decisive role for the inoculation, growth and differentiation of the cells. For a controlled 3D-cell growth the pore structure needs to be homogeneous and the pore size individually adjustable. For lyophilised scaffolds, the pore structure is determined by the ice crystal morphology during freezing under steady conditions. Scaffolds with a homogeneous pore structure and a range of pore size between 25 and 100 microns were reached. Cells such as preadipocytes, keratinocytes, and fibroblasts showed to adhere well to the collagen matrix.

Cell Division↗

Surface detected potentials of normal and reinnervated motor units: a simulation study for muscles consisted of short fibres.

We aimed to check whether the characteristics used up to now in macro EMG to distinguish between normal and reinnervated motor unit potentials (MUPs), were suitable for surface detected MUPs. MUPs produced by normal and reinnervated MUs were simulated with a fast and precise convolution model. An increased number of fibres in the MU territory enhanced the amplitude, area and RMS of the MUP proportionally irrespective of the MU-electrode distance. An increased scatter of the end-plates and greater desynchronization in the fibres' activation decreased the MUP amplitude and affected the temporal characteristics of the MUP (duration of the negative phase and its area to amplitude ratio). The effects were more pronounced at shorter distances. At larger distances, the effect of the MU-electrode distance on temporal and amplitude characteristics of MUPs was much stronger than that of the parameters changed with reinnervation. We conclude that reinnervated MUs consisting of short fibres can not be distinguished from the normal ones by means of characteristics of MUP used in macro EMG. To discriminate reinnervated MUs non-invasively, the MUP amplitude should be normalized in respect of the MU-electrode distance or other MUP characteristics (independent of MU-electrode distance and sensitive to reinnervation) should be used.

Action Potentials↗