PubMed Health⌕ Search

Biomedical subjects

G Reinisch

Publications and source records attributed to G Reinisch.

15 recordsLinked to original sources

Lung disease 35 years after aspiration of activated charcoal in combination with pulmonary lymphangioleiomyomatosis. A histological and clinicopathological study with scanning electron microscopic evaluation and element analysis.

Activated charcoal provides effective treatment for most toxic ingestions. Accidental aspiration of activated charcoal is rare. Previously, there have been a few single cases reported on charcoal-related pulmonary complications. We describe an unusual case of pulmonary lesions 35 years after accidental aspiration of activated charcoal. The 38-year-old female patient presented with recurrent pneumothorax. A routinely performed chest roentgenogram revealed pulmonary lesions, highly suggestive to lymphangioleiomyomatosis (LAM). Histopathological investigation of the lung tissue demonstrated some features of LAM but showed prominent pneumoconiotic lesions with cystic tissue destruction. The pneumoconiotic reaction was characterized by prominent black deposits accompanied by foreign-body granuloma formation and minimal fibrosis. Scanning electron microscopic investigation of these deposits showed particles measuring up to 300 microm in greatest diameter. Energy-dispersive X-ray spectra of these particles revealed carbon-rich material, presumably charcoal. The aspiration event was confirmed by the clinical history. To our knowledge, this is the first report not only on a long-term follow-up after aspiration of activated charcoal but also on charcoal-related pulmonary lesions in combination with LAM.

Adult↗

[A new ISO/FDIS 14242-1 compatible hip prosthesis simulator: E-SIM].

The continuing development of new, highly sophisticated materials for the articulating surfaces of total hip endoprostheses involves the need for testing, not only of biocompatibility and dynamic loadability, but also of tribological properties (friction, wear, lubrication). For decades, the wear resistance of these materials has been tested in wear simulators. In consequence of the currently often widely differing test methods, the technical committee (TC 150) of the ISO (International Organization for Standardization) has been concerned to develop an International Standard (ISO/FDIS 14242 1 and 2: Implants for Surgery--wear of total hip joint prostheses--on the basis of kinetic and kinematic data from gait analysis. This new standard will be the basis for ensuring the comparability of scientific data obtained from tribological testing of total hip endoprothesis. The new hip simulator, E-SIM, presented in this paper, complies with the currently published FDIS (Final Draft International Standard), and enables testing in accordance with these specifications.

Equipment Failure Analysis↗