Color-Doppler velocimetry of uterine arteries in pregnant and nonpregnant patients during multiovulation induction for IVF.

OBJECTIVES: To evaluate uterine artery resistance during multiovulation induction in relation to the implantation rate in patients attending in vitro fertilization (IVF) cycles. PATIENTS: Multiovulation induction for IVF was monitored by daily determination of the pulsatility index (PI) of the uterine arteries, obtained by a transvaginal probe (6.5 MHz) implemented with color-flow imaging. Doppler data were obtained from 5 days before hCG administration to the day of follicular aspiration. One IVF cycle was monitored in 70 patients. In 17 patients, 41 IVF cycles were monitored until a successful attempt occurred. RESULTS: In the 70 patients studied during one IVF attempt, the PI of the uterine arteries significantly varied (P < 0.001) in the different phases of the cycle. In the 24 patients who conceived, a significantly lower PI (P < 0.03) was found throughout the cycle. This result was mainly due to a highly significant difference of PI values observed the day after hCG administration (P < 0.005). In the 17 patients who conceived after 1 to 4 negative in vitro fertilizations, no significant difference in PI was observed in the uterine artery resistance in cycles in which implantation was or was not successful. CONCLUSIONS: Uterine artery resistance varies significantly during phases of the induction therapy. Uterine artery resistance is lower throughout the course of multiovulation induction in patients with higher pregnancy rates. The PI on the day after hCG administration was the best index of pregnancy rate. Low uterine artery resistance was present even in negative attempts in patients who eventually achieved a successful implantation. PI values < or = 3 can be considered a favorable prognostic factor for future IVF cycles.

Adult

[Experience in primary prevention of cardiovascular risk factors in children].

Pathologic studies have shown that atherosclerosis may already be present in childhood as reversible fatty streaks in the aortic intima. These findings are directly related to total serum cholesterol and inversely related to serum HDL cholesterol. This study was aimed at screening children and young adolescents of Novara for cardiovascular risk factors and achieving a specific health educational program. We screened a sample of 2560 children and young adolescents aged 10 to 16 years (mean 12) for known family history of cardiovascular diseases and hyperlipidemia, blood pressure values, serum cholesterol fractions and triglycerides. Of the 2560 children, 786 were considered at risk according to pre-defined cutoff points for systolic BP (> 120 mmHg) 10.6%, diastolic BP (> 80 mmHg) 3.4%, total serum cholesterol (= > 160 mg/dl) 18.7%, serum HDL cholesterol (< 40 mg/dl) 49.5%, total serum cholesterol/HDL ratio (> 4) 28.0%, and triglycerides (> 150 mg/dl) 3.7%. Parents were invited to change family lifestyle according to a specific health educational program, which included advice about diet and physical activity. All children at risk were re-examined 1 year later. Mean values of total serum cholesterol (129 +/- 26 vs 143 +/- 30, p < 0.001), triglycerides (86 +/- 28 vs 91 +/- 32, p < 0.01) and total serum cholesterol/HDL ratio (3.7 vs 3.8, p NS) were found to be lower than at index evaluation. The distribution of total cholesterol curve shifted to the left, and the high risk cases (total serum cholesterol > 200 mg/dl) lowered from 56 to 24 at the follow-up evaluation.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

Construction of a library of bovine genomic fragments enriched in CpG islands.

A procedure is described to isolate DNA probes from the bovine genome that are enriched in sites for the so-called rare cutter restriction endonucleases. A collection of SacII (CvCGCGG)-Hin-dIII fragments from bovine sperm was established in the plasmid Bluescript. 180 clones were picked at random and analysed for the presence of inserts with sites for the following rare cutters: EagI, BsshII, NarI, MluI, NruI, NaeI: 70% of the clones contained at least 1 site and 5% contained four different such sites. 22.8% had multiple sites for one or more of the rare cutters tested. Sequence analysis for 16 clones confirmed the cloning of DNA with a G+C content and a proportion of CpG vs GpCs indicative of CpG islands.

Animals

[The functional and hemodynamic benefits of automatic atrioventricular interval delay in permanent atrial synchronized pacing].

OBJECTIVES: In order to assess possible functional and hemodynamic benefits of different programming of atrioventricular (AV) delay--156 ms fixed vs 156 to 63 adaptive--two maximal exercise tests (cyclette) were performed in 8 patients (6 males, 2 females; 69 +/- 6 years) implanted with Chorus 6003 (Ela Medical, France) DDD pacemakers for complete AV block with normal sinus node function. METHODS: The measured parameters were: pacing rate, cardiac output (thermodilution method), oxygen consumption (2001 gas-exchange analyser), arterial-venous difference (derived from pulmonary oxygen saturation, through an optical-fibers Swan-Ganz catheter coupled to an Oximetric3-Abbott oximeter), human atrial natriuretic factor and lactate plasmatic levels, anaerobic threshold. RESULTS: A better cardiac output (11.4 +/- 1.7 vs 10.1 +/- 1.8 l/min) and oxygen consumption (1521 +/- 425 vs 1408 +/- 465 ml/min) were observed at maximal exercise with adaptive rather than with fixed AV delay programming (p < 0.05); moreover anaerobic threshold point was reached later during exercise test with adaptive AV delay (242 +/- 92 vs 216 +/- 109 sec, p = 0.05). On the contrary, with adaptive and fixed AV delay, there were not statistically different values of maximal heart rate (139 +/- 9 vs 139 +/- 9), levels at maximal exercise of arterial-venous difference (12.5 +/- 2 vs 12.8 +/- 1.4 Vol%O2), human atrial natriuretic factor (63 +/- 17 vs 78 +/- 48 pg/ml), lactate (29 +/- 15 vs 29 +/- 18 mg/dl), and oxygen consumption at anaerobic threshold point (772 +/- 164 vs 786 +/- 229 ml/min). CONCLUSIONS: In DDD pacing adaptive AV delay causes aerobic and hemodynamic benefits.

Aged

A new approach to the prevention of endless loop tachycardia in DDD and VVD pacing.

Endless loop tachycardia (ELT) is a possible complication in dual chamber pacing; it is usually prevented by programming the atrial refractory period (PVARP) longer than the retrograde ventriculoatrial (VA) conduction interval; this in some patients limits the upper rate. In 15 patients with a DDD (nine patients) or a single-pass lead VDD pacemaker (six patients) and retrograde atrial activation, telemetric recording documented a significant difference in amplitude of antegrade, and retrograde atrial potentials (VDD 1.21 +/- 0.32 mV vs 0.56 +/- 0.23 mV, P = 0.008; DDD 2.7 +/- 1 vs 1.8 +/- 1 mV, P = 0.038; Student's t-test for paired data). In 3/15 patients ELT stopped after programming of atrial sensitivity to a value greater than the retrograde P wave amplitude; in 11/15 patients this occurred at a sensing value lower than or equal to retrograde P wave amplitude with a high pass band filter operating. One patient required PVARP lengthening. Holter monitoring showed no more ELTs. In most patients with a DDD or single-pass lead VDD pacemaker with widely programmable sensing amplitude and Hi/Low bandpass filters, individual programming of atrial channel sensitivity prevents ELT without affecting the PVARP and, consequently, upper rate limit.

Aged

[Termination of ventricular tachycardia by noninvasive methods].

Present paper reports on a patient referred for sustained, hemodynamically well tolerated, ventricular tachycardia, terminated by noninvasive temporary pacing. The tachycardia was refractory to chest tump and intravenous standard drugs (lidocaine and propafenone). Demonstration of spontaneous atrioventricular dissociation and ventricular capture during transesophageal atrial pacing allowed rapid and correct diagnosis. Overdrive with external noninvasive ventricular pacing proved effective in terminating ventricular tachycardia and converting it to sinus rhythm. These observations suggest that noninvasive approach to hemodynamically stable ventricular tachycardia can provide a safe and effective alternative to more aggressive medical management.

Cardiac Pacing, Artificial

Restriction fragment length polymorphism analysis of the kappa-casein locus in cattle.

The two common genetic variants (A and B) of bovine kappa-casein originate from two point mutations in the codons for the aminoacids in position 136 and 148. These mutations give rise to polymorphic sites for the restriction endonucleases Hin dIII, AluI, HinfI, Mbo II and TaqI. We have examined DNAs of several Italian Friesian cows and bulls of known and unknown genotype by Southern analyses using kappa-casein cDNA probes. Restriction fragment length polymorphisms (RFLPs) specific for the A and B alleles were identified for each of the above enzymes, except for AluI, which has a non-polymorphic site 12bp away from the polymorphic one. We have also found two new polymorphic sites for MboII and TaqI in the non-coding regions. These sites differentiate the A allele into two new variants, named A1 and A2. The RFLP analysis permits the characterization of kappa-casein alleles even in the absence of their expression. This should facilitate selective breeding programmes aimed at increasing the frequency of the kappa-casein B allele whose product improves the cheesemaking properties of milk.

Amino Acid Sequence

Lack of influence of atrioventricular delay on stroke volume at rest in patients with complete atrioventricular block and dual chamber pacing.

Dual chamber pacing (DDD) maintains atrioventricular (AV) sequence; AV delay programmability modifies the relationship between atrial and ventricular contraction. To evaluate the hemodynamic effects of such a modification, ten patients with a DDD unit for complete AV block were studied by time-motion (M-mode) and Doppler echocardiography during inhibited ventricular pacing (VVI), atrial-triggered ventricular pacing (VDD) and atrioventricular sequential pacing (DVI) at different AV delay (90, 140, 190, 240 msec). A significant improvement in stroke volume (SV) (15%-20%, P less than 0.05) was seen during DDD versus VVI pacing; no changes, however, were observed in the same patient with different AV delay or during DVI versus VDD pacing. These data suggest that programming of AV delay does not affect systolic performance at rest; longer diastolic filling times recorded during DDD pacing with "short" AV delay (90-140 msec) do not seem to be a hemodynamically relevant epi-phenomenon of PM programming.

Aged

Sustained beneficial hemodynamic effects of low transdermal nitroglycerin doses compared with placebo in patients with congestive heart failure.

In an attempt to resolve some of the controversies concerning the dose requirements and duration of effects of transdermal nitroglycerin (NTG) in patients with heart failure (CHF), the short-term hemodynamic responses to transdermal NTG, in a 20 cm2 self-adhesive patch (10 mg/24 h), were evaluated in 10 patients with severe chronic CHF using a randomized, within-patient, double-blind, placebo-controlled cross-over trial. Serial hemodynamic measurements over 24 h revealed sustained effects that began 1 h after the application of nitroglycerin patch and fully persisted throughout the study. The peak effect occurred at 4 h with the pulmonary capillary wedge pressure decreasing from 33.7 +/- 8.4 to 21.4 +/- 9 mmHg (mean +/- SD) (p less than 0.05) and the cardiac index increasing from 2.5 +/- 0.6 to 3 +/- 0.6 l/min/m2 (p less than 0.01). Transdermal nitroglycerin also significantly reduced pulmonary arterial and right atrial pressures (from 43.5 +/- 9.5 to 31 +/- 11.4 and from 7.4 +/- 6.6 to 3.8 +/- 4.7 at peak effect, respectively) as well as pulmonary and systemic vascular resistances (from 10.7 +/- 6.6 to 6.5 +/- 3.2 and from 26.2 +/- 5.1 to 22.5 +/- 5.7, respectively). There was no change in heart rate or systemic arterial pressure. These beneficial hemodynamic responses persisted for 24 h. No rebound deterioration occurred upon withdrawal of the nitroglycerin. No significant hemodynamic changes occurred during placebo treatment period. Thus, low doses (10 mg/24 h) of transdermal nitroglycerin induce significant hemodynamic benefit that is sustained for 24 h in patients with heart failure.(ABSTRACT TRUNCATED AT 250 WORDS)

Administration, Cutaneous

Physiological sensitivity of respiratory-dependent cardiac pacing: four-year follow-up.

Clinical and physiological data on long-term follow-up of 143 patients with respiratory-dependent pacemakers (RDP3) are reported; 121 patients received ventricular (VVI-RD) and 22 patients atrial (AAI-RD) respiratory-dependent stimulation. Functional evaluation was based on the exercise testing (130 pts) with oxygen uptake VO2, ventilation, ECG and arterial pressure monitoring and the dynamic Holter electrocardiogram (95 pts). In each patient, the stimulation rate curve selected was that which produced the best work tolerance and moved the anaerobic threshold to the right. Respiratory levels were assessed by telemetry verifying proper sensing of tidal volume variations and absence of interference and artefacts. In patients with VVIR or AAIR stimulation, exercise tolerance, oxygen uptake and anaerobic threshold increased significantly in comparison with VVI or AAI pacing respectively. The physiological sensitivity of the stimulation system (i.e., a linear relationship of the pacing rate with metabolic requirements) was excellent (up to exhaustion) in 70%, very good (up to anaerobic threshold) in 20% and erratic (no relationship between pacing rate and VE/VO2) in 10% of patients. In dynamic electrocardiographic monitoring, the automatic pacing rate was always predominant during the night and during rest periods; the pacing rate increased properly with daily activity; myopotential inhibition (none longer than 3,500 ms) was observed in 38 patients, but without subjective complaints. The incidence of the RDP3 malfunction was less than 8%; it may have stemmed from the pacing system itself, or from other clinical conditions. Oversensing of impedance system pulses has not been recorded in the last 3 years. Partial respiration undersensing results from incorrect accessory lead position, pulmonary emphysema, marked obesity or other causes. Respiratory sensing becomes erratic at the anaerobic threshold point in such patients, but functions well at submaximum exercise levels. In patients with left ventricular failure, exercise tolerance was improved by setting a lower ratio between the pacing rate and respiration, which prevented the occurrence of excessive pacing rates.

Aged

Respiratory-dependent atrial pacing, management of sinus node disease.

The effectiveness of respiratory-dependent atrial pacing (AAI-RD) was assessed in 23 patients (11 male, 12 female; 68 +/- 10 years) with symptomatic isolated sinus node disease (SND). Follow-up was performed at 3 month intervals and included history taking, physical examination, ECG recording and 24-hour Holter monitoring. An incremental treadmill exercise test was performed in 21/23 patients before pacemaker implantation, in 23/23 patients after implantation (at least two tests with different programmed settings of respiratory rate/paced rate ratio); 21/23 patients underwent treadmill tests during both fixed rate 70 bpm and AAI-RD pacing. Physiological sensitivity of AAI-RD pacing was found excellent in 34 tests (85%) and fair in six (15%). Spontaneous heart rate was significantly higher after pacemaker implantation (bpm 115 +/- 20 vs 98 +/- 24, P less than 0.001). In 10/21 patients paced rate was significantly higher during AAI-RD vs AAI pacing (131 +/- 9 vs 106 +/- 16, P less than 0.001) with better total work time (min 9.9 +/- 4 AAI-RD vs 6.8 +/- 2.6 AAI, P less than or equal to 0.002), higher oxygen consumption at anaerobic threshold (ml/min 1137 +/- 406 AAI-RD vs 882 +/- 268 AAI-RD vs 5.5 +/- 2.6 AAI, P = 0.001). No significant difference was found in 7/21 patients (overlap between spontaneous and paced rate during both AAI-RD and AAI programming); 4/21 patients did not reach anaerobic threshold owing to osteomuscular limitations. AV block was detected in 1/23 patients, Biorate circuital failure in 1/23, sporadic undersensing in 5/23, short and symptom-free myopotential inhibitions in 10/23.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

[Physiologic limitations of dual chamber stimulators during physical activity].

Dual chamber DDD pacing is fully physiologic when chronotropic response of sinus node to exercise is normal and when retrograde ventriculo-atrial conduction is absent. Comparison of results from exercise test with increasing work load showed that atrial-triggered ventricular pacing provides a significant functional benefit (delta VO2 15%) P less than 0.01, if compared with fixed rate ventricular pacing. The benefit is closely related with the amount of sinus rate increase during exercise. In patients with sinus node syndrome the atrial triggered ventricular pacing rate did not show significant increase during exercise and exercise capability was similar to that observed with fixed ventricular pacing. Retrograde ventriculo-atrial conduction was observed in 56% of patients with sick sinus syndrome and 28% of patients with complete AV block and was the reason for endless loop tachycardias (ELTs). ELTs can be eliminated by lengthening atrial refractory period (ARP). In patients with ARP greater than or equal to 250 ms (47%), mild (8:7, 4:3) or important (2:1) AV block appeared during exercise test, with sudden drop of pacing rate and cardiac output at highest work load. Among other "physiologic" pacing modes, respiration traced ventricular stimulation showed high physiologic sensitivity (90%) and haemodynamic benefit comparable to that obtained during dual chamber pacing and without the related disadvantages.

Aged

[Arrhythmia in patients with a DDD bicameral pacemaker].

Dual chamber pacemakers, with coordinate atrial and ventricular sensing and stimulation (DDD), even if allowing "physiological" pacing, exhibited new and complicated arrhythmic manifestations, whose real frequency is still unascertained. In 65 patients (mean age 68 +/- 12 years), implanted with a DDD multiprogrammable device (15 pts. Medtronic Versatrax 7000 A, 50 pts. Pacesetter AFP 283), we carried out a 24 hours Holter monitoring while pacemaker was programmed with standard parameters. In a subset of 15 patients Holter monitoring was performed before and after pacemaker implantation. We evidenced: a) atrial sensing and/or pacing malfunction in 3 patients (4.5%); b) pacer-unrelated arrhythmias in 49 patients (75%): atrial extra beats 35 patients (54%), ventricular extra beats 23 patients (35%), non-sustained ventricular tachycardias 10 patients (15%), atrial tachyarrhythmias 8 patients (12%); c) supraventricular arrhythmias with PM-mediated high rate ventricular pacing in 12 patients (18%); d) PM induced and sustained endless loop tachycardias in 31 patients (47%); e) arrhythmias depending on over-sensing in 11 patients (17%): myopotential interferences 9 patients (14%), cross-talk ventricular pacing inhibition 2 patients (3%). The prevalence of ventricular arrhythmias was not different before and after the pacemaker implantation. The prevalence of atrial extrasystoles (53% versus 40%) and atrial tachyarrhythmias (26% versus 6%) decreased after the pacemaker implantation. Aimed reprogramming with progressive extension of atrial refractory period (from 250 to 400 msec and DDX) achieved disappearance of PM-endless loop tachycardias in 95%. Use of multi-programmability lowered the incidence and symptoms of most PM-related arrhythmias. Drug therapy was of choice in clinical arrhythmias unrelated to pacer.

Amiodarone

Respiration-dependent ventricular pacing compared with fixed ventricular and atrial-ventricular synchronous pacing: aerobic and hemodynamic variables.

A pacemaker that adapts heart rate in response to the patient's metabolic requirements has been developed. The pacemaker uses breathing frequency and tidal volume as the indicators of physiologic demand. Maximal physical work capacity, anaerobic threshold, oxygen uptake (16 patients) and hemodynamic variables (9 patients) were assessed with fixed rate (VVI), atrial synchronous (VDT/I) and respiration-dependent ventricular (VVI-RD) pacing. All subjects attained their anaerobic threshold in stress tests with VVI pacing. The maximal physical capacity (p less than 0.001), work time to attain the anaerobic threshold (p less than 0.01) and oxygen uptake (p less than 0.001) were significantly greater with VVI-RD than with VVI pacing. The transition from the supine to the standing position was characterized by a significant increase of cardiac index at rest with both VDT/I and VVI-RD pacing as compared with VVI pacing. Progressive increments in the cardiac index and average left ventricular stroke work index were significantly different at submaximal and maximal exercise when VVI and VVI-RD were compared. At maximal exercise, mean cardiac output was also significantly different: 10.21 +/- 2.5 (SD) liters/min with VVI, 11.2 +/- 0.8 liters/min with VDT/I (p less than 0.05) and 12.65 +/- 3.1 liters/min with VVI-RD (p less than 0.05) pacing. Maximal oxygen extraction values were greater with VVI and VVI-RD pacing than with VDT/I pacing. Pulmonary artery end-diastolic pressures at maximal exercise were within the normal range with the three different modes of pacing. In conclusion, there is a significant (25%) improvement in exercise performance with VVI-RD pacing as compared with VVI pacing.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

Increasing cardiac rate by tracking the respiratory rate.

The rate responsive pacemaker using respiratory rate as a sensor was implanted in 22 patients, 19 patients for ventricular pacing and three for atrial pacing. The level of exercise achieved with this system was consistently higher than with a fixed ventricular pacing rate. In addition, no special chemical or mechanical sensors are required; the sensor itself is simple, long-lasting, and energy efficient. Thus, this system adapts easily to the individual patient.

Adolescent