PubMed Health⌕ Search

Biomedical subjects

G Rowley

Publications and source records attributed to G Rowley.

At least 37 records · Page 2Linked to original sources

First report on UK database of haemophilia B mutations and pedigrees. UK Haemophilia Centres.

In order to obtain complete success in the carrier and prenatal diagnoses required for genetic counselling in haemophilia B a new strategy is being implemented in the UK. This entails the construction of a national confidential database of mutations, pedigrees and haematological data. This will allow the inefficient indirect tests based on the analysis of DNA polymorphisms to be abandoned and direct detection of the gene defect to be used instead. After two and a half years of nationwide collaboration, 702 samples have been collected from 313 families, representing more than half of the UK haemophilia B families, and 217 mutations have been characterised. The 141 diagnostic tests so far performed have clearly indicated that the new strategy not only allows virtually 100% diagnostic success, but also rapid results. This work on haemophilia B may represent a model for other diseases with high mutational heterogeneity.

Databases, Factual↗

Molecular analysis of mutations in the hprt gene in circulating lymphocytes from normal and DNA-repair-deficient donors.

Circulating lymphocytes from patients with the DNA-repair-deficient disorders, xeroderma pigmentosum (XP) and ataxia telangiectasia (A-T) have elevated frequencies of mutants at the hypoxanthine-guanine phosphoribosyltransferase (hprt) locus. We have analysed the DNA sequence of the hprt gene in mutants from normal donors, and compared them with mutants from XP and A-T individuals. In normal donors we found a range of mutations including principally transitions (40%), transversions (32%) and small deletions (20%). In an excision-deficient XP donor from complementation group C the mutation spectrum was similar to that from normal donors, whereas in an XP variant there was a significantly higher frequency (44%) of small deletions. In the two A-T donors, there was a high frequency of large deletions (22 and 75%) compared with only 4% in normal donors.

Adult↗

Mutations which alter splicing in the human hypoxanthine-guanine phosphoribosyltransferase gene.

A large proportion of mutations at the human hprt locus result in aberrant splicing of the hprt mRNA. We have been able to relate the mutation to the splicing abnormality in 30 of these mutants. Mutations at the splice acceptor sites of introns 4, 6 and 7 result in splicing out of the whole of the downstream exons, whereas in introns 1, 7 or 8 a cryptic site in the downstream exon can be used. Mutations in the donor site of introns 1 and 5 result in the utilisation of cryptic sites further downstream, whereas in the other introns, the upstream exons are spliced out. Our most unexpected findings were mutations in the middle of exons 3 and 8 which resulted in splicing out of these exons in part of the mRNA populations. Our results have enabled us to assess current models of mRNA splicing. They emphasize the importance of the polypyrimidine tract in splice acceptor sites, they support the role of the exon as the unit of assembly for splicing, and they are consistent with a model proposing a stem-loop structure for exon 8 in the hprt mRNA.

Base Sequence↗

Reliability and accuracy of the Glasgow Coma Scale with experienced and inexperienced users.

To investigate whether the Glasgow Coma Scale (GCS) can be used reliably and accurately by inexperienced observers, ratings made by observers grouped by level of experience were examined for within-group interobserver disagreements and for discrepancies with scores given by an expert. The GCS was used accurately by experienced and highly trained users, but inexperienced users made consistent errors. The errors were such that they would not be detectable by studies that examine only interobserver agreement, and they were substantial, averaging in some cases more than one point on the four-point and five-point scales of the GCS. Also, the error rates were highest at the intermediate levels of consciousness, for which the detection of changes in condition is vital. The findings support the continued use of the GCS by appropriately qualified personnel, but call into question much of the conventional wisdom about its reliability when used by untrained or inexperienced staff. The findings also suggest that interobserver comparisons are insufficient for establishing the viability of the GCS.

Evaluation Studies as Topic↗

Changes in the synovia after the intra-articular injection of sodium hyaluronate into normal horse joints and after arthrotomy and experimental cartilage damage.

Sodium hyaluronate was injected into normal horse joints and joints that had undergone an arthrotomy and experimental cartilage damage. The elimination half-life for hyaluronic acid in normal joints was found to be approximately 96 h. The injection caused a non-significant increase (42%) in synovial fluid protein concentration and a fall in the intrinsic viscosity of the fluid. In the arthrotomy group the synovial fluid hyaluronic acid concentration fell after surgery but it was unaffected by the injection of sodium hyaluronate. An initial rise in the intrinsic viscosity of the synovial fluid from the arthrotomy group coincided with an increase in protein concentration. However there was no significant difference between the mean intrinsic viscosity or protein concentration in synovia from the control and treated joints at any time after surgery.

Animals↗

Quantitation of hyaluronic acid in equine synovia.

An assay for the determination of hyaluronic acid concentration in equine synovia (synovial fluid) was investigated. The method involved the degradation of hyaluronic acid, using a highly specific microbial enzyme. The unsaturated tetra- and hexasaccharide products were oxidized with periodate and caused to react with thiobarbituric acid for form a chromophore which absorbed in the visible range of the spectrum. The method was precise within acceptable limits for synovia and compared favorably with the widely used carbazole method of Bitter and Muir (Anal Biochem 4:330-334, 1962). The between-assay coefficient of variation was 1.7% and the method was found to be linear to 100 microgram of hyaluronic acid. The mean value for hyaluronic acid concentration in synovia of health horses was 127 mg/100 ml.

Animals↗