PubMed HealthSearch

Biomedical subjects

G S Karczmar

Publications and source records attributed to G S Karczmar.

At least 19 recordsLinked to original sources

Changes in T2*-weighted images during hyperoxia differentiate tumors from normal tissue.

Experiments were performed to determine whether changes in T2*-weighted MR images during and after hyperoxia differentiate tumors from normal tissue. Mammary adenocarcinomas implanted in the right hind limbs of rats were studied. Gradient echo images were obtained at 2 Tesla with an evolution time of 20 ms and a recycle time of 1 s. Breathing gas was either air or 100% O2. Significant increases in image intensity were observed in tumor centers and rims during hyperoxia while much smaller changes were detected in the surrounding muscle. The relaxation rate (1/T2*) in tumors decreased during hyperoxia by an average of 2.5 +/- 1.0 s-1, while in muscle the average change was an increase of 0.6 +/- 2.1 s-1. The largest decreases in relaxation rate were detected in non-necrotic tumor regions with relatively low density of blood vessels. Immediately following hyperoxia significant decreases in intensity were detected in tumors while much smaller decreases were detected in the surrounding muscle.

Adenocarcinoma

Effects of hyperoxia on T2* and resonance frequency weighted magnetic resonance images of rodent tumours.

Experiments were performed to determine whether T2* and resonance frequency weighted MR images are sensitive to effects of hyperoxia on model tumors. Hyperoxia can increase tumor oxygen tension and thus affect T2* and/or the average resonance frequency within each image voxel due to the paramagnetism of oxygen itself or through modulation of the oxidation state of hemoglobin. Alternatively, changes in T2* during hyperoxia may reflect changes in tumor water content due to changes in systemic blood pressure. Mammary adenocarcinomas implanted in the flanks of rats were studied. Imaging sequences were preceded by two 90 degrees pulses separated by an evolution period of 50 or 75 ms and followed by a crusher gradient to eliminate transverse magnetization. This pulse sequence produced images which were sensitized to both T2* and the average resonance frequency of each voxel. Images were produced at 2 T using a gradient echo imaging method with a TR of 3 s. Images obtained during inhalation of air and 100% O2 were compared. Significant increases in image intensity were observed in most tumors during hyperoxia, particularly at the tumor center. The increase was accentuated when the evolution period was increased and greatly reduced when a 180 degrees refocusing pulse was placed at the center of the evolution period. These results suggest that hyperoxia reduces local magnetic susceptibility gradients leading to an increase in T2* or causes a shift in resonance frequency. The magnitude of this change may be a function of the rate at which oxygen is delivered to and metabolized by tumors and may also reflect tumor oxygen tension under normoxic conditions.(ABSTRACT TRUNCATED AT 250 WORDS)

Adenocarcinoma

Magnetic resonance imaging of rodent tumors using radiofrequency gradient echoes.

This paper evaluates the use of radiofrequency (RF) magnetic field gradient echoes to provide contrast in magnetic resonance (MR) images of model tumors. Decay of RF gradient echoes as a function of evolution time was measured and sensitivity of the decay to changes in blood pressure was evaluated. Previous investigators have demonstrated that static field (B0) gradient echoes provide MR image contrast which is sensitive to the rate of self-diffusion of tissue water and may also be sensitive to the rate of tissue perfusion. Gradient echoes produced by RF magnetic field gradients provide a useful alternative to the conventional B0 methods. Unlike B0 gradient echoes RF gradient echoes are relatively insensitive to local magnetic susceptibility gradients and to magnetic field gradients produced by eddy currents. Differences between the two methods may be particularly significant for studies of tumors where large concentrations of deoxyhemoglobin and other paramagnetic substances may cause significant susceptibility gradients. Mammary adenocarcinomas subcutaneously implanted in the flanks of female Fisher rats were studied. Magnetic resonance experiments were performed at 2 T. A surface coil was used to provide an RF gradient and to excite and detect signals from the tumors. The decay of echo amplitude as a function of evolution time was measured and the decay at short and long evolution times was analyzed independently to calculate two apparent diffusion coefficients (ADCs). The preparation was extremely stable and the standard error for 10 consecutive measurements of gradient echo amplitude made over 30-60 min with an RF gradient strength of 50 kHz/cm, gradient duration of 1 ms (i.e., 50 cycles/cm), and echo evolution time (td) of 1 s was generally +/- 0.8%. The ADC calculated from the decay at short evolution times was approximately 3 x 10(-5) cm2/s. The ADC calculated from the decay at longer evolution times was approximately 0.5 x 10(-5) cm2/s. Both ADCs decreased immediately following sacrifice and administration of Hydralazine. The experiments demonstrate that measurements of RF gradient echo amplitudes in tumors can be made in vivo with a high degree of reproducibility and suggest that RF gradient echo amplitudes are sensitive to acute physiological changes in tumors. This method may be useful for characterization of tumors and prediction and monitoring of effects of therapeutic agents.

Animals

Selective depletion of tumor ATP by 2-deoxyglucose and insulin, detected by 31P magnetic resonance spectroscopy.

The purpose of this study was to investigate whether substrate deprivation acutely and selectively decreases ATP concentration in an experimental sarcoma. Two methods of substrate deprivation were examined: glycolysis was inhibited using 2-deoxyglucose (2DG), and plasma substrate levels were reduced using insulin. The effects of treatment on tumor ATP, inorganic phosphate, and pH were studied by 31P nuclear magnetic resonance spectroscopy. 2DG (2 g/kg) was administered i.p. to rats bearing s.c. methylcholanthrene-induced sarcomas. Inhibition of glycolysis by 2DG caused a 52 +/- 13% (SE) decrease in the tumor ATP to inorganic phosphate ratio, associated with a decrease in pH of 0.38 +/- 0.10 unit. The same dose of 2DG caused no significant change in the ratio of phosphocreatine to ATP in brain. Insulin (125 units/kg, i.p.) caused a 68% decline in plasma glucose and a 71% decline in betahydroxybutyrate compared to saline-treated animals. Concomitantly, 31P nuclear magnetic resonance spectroscopy detected a 48 +/- 13% decrease in sarcoma ATP, with a reciprocal elevation of inorganic phosphate in insulin-treated animals. In contrast, the brain phosphocratine/ATP ratio was unaffected by insulin. These results suggest that large tumors are acutely sensitive to inhibition of glycolysis and reductions in plasma levels of substrates for oxidative phosphorylation and glycolysis, while the brain is unaffected. In addition, this work provides support for the use of 31P nuclear magnetic resonance spectroscopy to monitor tumor response to therapy.

Adenosine Triphosphate

Hepatic cancers and their response to chemoembolization therapy. Quantitative image-guided 31P magnetic resonance spectroscopy.

RATIONALE AND OBJECTIVES: Hepatic embolization combined with intra-arterial administration of cytostatic drugs (chemoembolization) is frequently used to treat primary and metastatic cancers to the liver. Quantitative phosphorus-31 magnetic resonance spectroscopy (31P MRS) was used to assess the metabolic state of hepatic cancers and their metabolic response to chemoembolization. METHODS: Fifteen localized 31P MRS studies were performed on five patients with liver tumors. Thirteen healthy volunteers served as controls. Metabolite ratios and molar metabolite concentrations were calculated. RESULTS: Untreated hepatic tumors, relative to normal controls, showed elevated phosphomonoester/adenosine triphosphate (PME/ATP) ratios, reduced concentrations of ATP and inorganic phosphate (Pi), and normal phosphodiester (PDE) concentrations. As an acute response to chemoembolization, ATP, PME, and/or PDE concentrations diminished, whereas Pi concentrations increased or stayed relatively constant. Long-term follow-up after chemoembolization showed decreased PME/ATP and increased ATP concentrations in the absence of changes on standard magnetic resonance and computed tomographic images. CONCLUSIONS: These preliminary spectroscopic data suggest that quantitative 31P MRS can be successfully used to monitor directly metabolic response to hepatic chemoembolization.

Adenocarcinoma

31P MRS of myocardial inorganic phosphate using radiofrequency gradient echoes.

Determination of the chemical shift and integral of the myocardial intracellular inorganic phosphate (Pi) resonance by 31P magnetic resonance spectroscopy (MRS) is often precluded due to a large overlapping signal from 2,3-diphosphoglycerate (2,3-DPG) from chamber and myocardial blood. This report demonstrates the use of radiofrequency (RF) magnetic field gradient echoes (RFGE) to eliminate signals from 2,3-DPG in flowing blood, while retaining signals from intracellular myocardial Pi, ATP, and phosphocreatine (PCr). The ECG-triggered 31P spectra were acquired from the myocardium of open chest pigs using a Philips Gyroscan 2-T magnetic resonance spectrometer. A 2.5-cm-diameter surface coil attached to the myocardium was used to provide the RF gradient as well as for excitation and detection of signals. Optimal performance of the RFGE pulse sequence was obtained when the RF gradient pulses were centered at peak diastole or peak systole. Under these conditions, 2,3-DPG signals were completely suppressed, and sensitivity was usually sufficient to allow detection of a well-resolved Pi signal. Myocardial pH determined from RFGE experiments was 7.16 +/- 0.10, and the ratio of the integrals of the Pi and ATP resonances (Pi/ATP) was 0.24. The mean signal-to-noise ratio (S/N) for PCr in control spectra acquired in 4 min was 19/1, while the mean S/N for PCr in RFGE-edited spectra acquired in 15 min was 11/1, demonstrating that the present implementation of the RFGE method results in significant loss in sensitivity. These experiments demonstrate that RFGE-editing allows accurate determination of the chemical shift and integral of the Pi resonance in blood-perfused myocardium in situ.

2,3-Diphosphoglycerate

P-31 spectroscopy study of response of superficial human tumors to therapy.

Studies were performed to characterize phosphorus-31 magnetic resonance (MR) spectra obtained from 10 superficial human tumors outside the brain and to determine whether P-31 MR spectroscopy could allow detection of a response to therapy before a change in tumor size was measured. The ratio of phosphomonoester to adenosine triphosphate peak intensities (PME/ATP) was unusually large in all tumors studied. The average PME/ATP in lymphomas (1.8 +/- 0.5) was greater than in nonlymphoma cancers (1.1 +/- 0.15). The average PME/ATP for all tumors studied (1.4 +/- 0.5) was much greater than that of underlying skeletal muscle (0.23 +/- .09). Eight of the tumors were studied before and after therapy. Responders were distinguished from nonresponders on the basis of changes in tumor size. PME/ATP decreased during therapy in three lymphomas that responded to therapy. In an adenocarcinoma and Ewing sarcoma that did not respond to therapy, PME/ATP increased. PME/ATP remained constant in two squamous cell carcinomas that responded to therapy and decreased in one squamous cell carcinoma that decreased in size by 40% but was classified as a nonresponder. Changes in PME/ATP did not always parallel changes in tumor size during therapy. In two patients, a decrease in PME/ATP preceded a decrease in tumor size. In four patients, PME/ATP increased transiently during periods when tumor size remained constant.

Adenosine Triphosphate

Comparison of 31P MRS and 1H MRI at 1.5 and 2.0 T.

The goals of this study were to compare 31P magnetic resonance spectroscopy (MRS) and 1H magnetic resonance imaging (MRI) of human subjects and phantoms at 1.5 and 2.0 T. The 31P signal-to-noise (S/N) ratios in phantom standards and in localized volumes in human brain and liver were compared at 1.5 and 2.0 T. In addition, T1 values for 31P resonances in human brain, 31P linewidths of metabolites in human brain and liver, 1H S/N in a phantom standard, and MR image quality in human head and body were compared at the two field strengths. The results of our study showed that at the higher strength field, (1) in vivo 31P MRS studies benefited from up to 32% improvement in S/N; (2) in vivo 31P MRS studies also benefited from increased spectral dispersion; (3) the quality of MR head images remained comparable; and (4) body images showed some decrease in image quality due to increased chemical shift, and flow and motion artifacts.

Brain

Non-invasive quantitation of human liver metabolites using image-guided 31P magnetic resonance spectroscopy.

Phosphorus-containing metabolites in normal human liver have been quantitated non-invasively with 31P magnetic resonance spectroscopy using surface coils. The location of the volume of interest (VOI) was defined by 1H magnetic resonance imaging. Subsequently, a modified three-dimensional localization technique (ISIS) was used to acquire 31P magnetic resonance spectra from the VOI. To account for partial saturation produced by rapid signal averaging, the spin/lattice relaxation times (T1) of all hepatic phosphorus resonances were measured. The corrected resonance integrals were used to derive absolute molar concentrations for the following hepatic metabolites (mmol/kg wet weight): ATP, 2.0; inorganic phosphate, 2.1; phosphodiesters, 5.4; and phosphomonoesters, 0.9. These values are compared with previously reported values for humans using freeze-clamping techniques, and provide a basis for comparison with studies of hepatic disease in this laboratory.

Adenosine Triphosphate

Image-guided 31P magnetic resonance spectroscopy of normal and transplanted human kidneys.

Image-guided 31-phosphorus magnetic resonance spectroscopy (MRS) was used to obtain spatially localized 31P spectra of good quality from healthy normal human kidneys and from well-functioning renal allografts. A surface coil of 14 cm diameter was used for acquiring phosphorus signals solely from a volume-of-interest located within the kidney. To determine the effects of kidney transplantation on renal metabolism, patients with well functioning allografts were studied. Little or no phosphocreatine in all spectra verifies the absence of muscle contamination, and is consistent with proper volume localization. The intensity ratio of phosphomonoesters (PME) to adenosine triphosphate (ATP) resonances in transplanted kidneys (PME/ATP = 1.1 +/- 0.4) was slightly elevated (P = 0.2) compared to that of healthy normal kidneys (PME/ATP = 0.8 +/- 0.3). The inorganic phosphate (Pi) to ATP ratio was similar in the two groups (Pi/ATP = 1.1 +/- 0.1 in transplanted kidneys vs. 1.2 +/- 0.6 in normal kidneys). Acid/base status, as evidenced from the chemical shift of Pi, was the same in both normal controls and transplanted kidneys. Despite the practical problems produced by organ depth, respiratory movement, and tissue heterogeneity, these results demonstrate that image-guided 31P MR spectra can reliably be obtained from human kidneys.

Adult

Regulation of hepatic inorganic phosphate and ATP in response to fructose loading: an in vivo 31P-NMR study.

Fructose loading results in hepatic accumulation of fructose 1-phosphate (Fru1 P). The goals of the present experiments were: first, to distinguish between ATP, intracellular inorganic phosphate (Pi), and extracellular Pi as sources of phosphate for the phosphorylation of fructose, and second, to examine the influence of ATP and Fru1 P on movement of phosphate into and out of these three pools. To achieve these goals, 31P-NMR was used to monitor the response of hepatic ATP, Pi and Fru1 P to two consecutive injections of fructose. The first was administered with ATP at the control level, and the second, 1 h after the first, with ATP at 65% of the control level. Changes in intra- and extracellular Pi were distinguished by correlating measurements of total NMR-detectable phosphorus and NMR-detectable Pi with measurements of plasma Pi. The initial fructose injection resulted in rapid accumulation of Fru1 P, small decreases in plasma and NMR-detectable Pi and a dramatic decrease in ATP. Total NMR-detectable phosphorus did not change, suggesting that phosphate did not enter or leave the liver. Therefore, accumulation of Fru1 P was initially balanced by an equivalent decrease in ATP, without large changes in Pi. Following the second injection, when ATP was at 65% of control. Fru1 P accumulated at approximately the same rate and to the same level as achieved following the first injection. There was little further change in ATP and a marked decrease in NMR-detectable Pi, while plasma Pi was higher than after the first injection. Therefore the greater decrease in NMR-detectable Pi following the second injection represented a significant decrease in intracellular Pi. Return of Fru1 P to control coincided with a dramatic increase in plasma Pi, and a decrease in total NMR-detectable phosphate. This suggests that phosphate released from Fru1 P entered the extracellular space. These data suggest the mechanisms by which intracellular Pi is regulated. When sufficient ATP is available, ATP hydrolysis supplies phosphate for the synthesis of Fru1 P, and prevents a significant decrease in intracellular Pi. When ATP is reduced, accumulation of Fru1 P depletes intracellular Pi. Therefore, decreased availability of ATP correlates with increased utilization of intracellular Pi. When Fru1 P returns to control, the increase in intracellular Pi is limited by release of Pi into the plasma.

Adenosine Triphosphate

Early metabolic response to tumor necrosis factor in mouse sarcoma: a phosphorus-31 nuclear magnetic resonance study.

To investigate the effects of recombinant human tumor necrosis factor alpha (rHuTNF-alpha) on high-energy phosphate metabolism of cancer cells, 31P nuclear magnetic resonance (NMR) studies were performed on a murine methylcholanthrene-induced sarcoma. Injection of 15 micrograms of rHuTNF-alpha caused progressive depletion of ATP and phosphocreatine within 90 min, together with an increase in inorganic phosphate. Metabolic changes were correlated with the early histological appearance of thrombosis and hemorrhage. A spatially localized NMR technique demonstrated that these changes were specific for the tumor. Acute ischemia of the tumor produced similar metabolic changes; thus the metabolic effects of rHuTNF-alpha could be due to either a primary action on tumor biochemistry or a secondary action produced by ischemia. These findings indicate that rHuTNF-alpha has a very rapid onset of action, which can be detected by 31P NMR. Furthermore, the results suggest that 31P NMR spectroscopy will be extremely useful for detecting early biochemical changes produced by rHuTNF-alpha or other treatments in animal and human cancers.

Adenosine Triphosphate

A 31P NMR study of the GI tract: effect of fructose loading and measurement of transverse relaxation times.

The effect of fructose loading on high-energy phosphates in the jejunum, ileum, and large intestine of rats was studied using 31P NMR. Following fructose loading, an increase in the intensity of the PME resonance was observed in the jejunum, indicating an accumulation of fructose-1-phosphate. There were no significant changes in ATP or Pi. This demonstrates that the activity of fructokinase in the jejunum can be monitored by 31P NMR. Fructose loading had no detectable effect on metabolite levels in the ileum and large intestine. Resolution of intestinal spectra was poor due to unusually large linewidths and the presence of broad underlying signals. To study the mechanism of line broadening, the T2's of the phosphorus resonances were measured using a solenoidal coil. The T2's of the ATP, Pi, PME, and PCr resonances were much longer than the T2's, suggesting that the linewidths of these resonances are primarily due to susceptibility gradients and/or compartmentation of metabolites. Other signals, particularly in the PDE region, were homogeneously broadened and had very short T2's. Spin echoes obtained with evolution times of 1 to 4 ms suppressed these broad components, with little loss of intensity in the inhomogeneously broadened resonances; as a result, resolution was improved.

Animals

Computer simulation of MRS localization techniques: an analysis of ISIS.

Computer simulations were used to evaluate the ISIS localization technique as implemented with both head and surface coils. The effects of chemical shift, B1 inhomogeneity, repetition time, T2 relaxation, a postacquisition saturation pulse, and a B1 insensitive observation pulse were examined. Integrals of ISIS signals over the sample volume showed that significant signal loss from the volume of interest (VOI) and contamination from outside the VOI can occur for both head and surface coil ISIS experiments. The results showed that the saturation pulse, order of the various ISIS acquisitions, and repetition time affect contamination but not signal loss. In addition, short T2 and high RF power can combine synergistically to degrade the selective inversion pulses, causing further contamination and signal loss.

Computer Simulation

Improvement of the rotating frame experiment by detection of residual Z magnetization: a 31P MRS study of metabolite levels in a Meth-A sarcoma.

The radio frequency field (B1) gradient of a surface coil can be used to obtain spectra from a series of sample regions which experience different B1 field strengths. We previously reported that the sensitivity of this method, known as the surface coil rotating frame experiment (SCRFE), can be enhanced by applying a composite pulse immediately after signal acquisition to sample residual Z magnetization which is normally undetected. Initially this modified SCRFE was used to obtain spatially resolved spectra across a B1 gradient of a factor of 2.5. Here we demonstrate the extension of this method to map phosphorylated metabolites across a B1 gradient of a factor of close to 5. Computer simulations were used to evaluate the performance of the composite pulse, and to assist in analyzing the data. The method was used to obtain 31P spectra in vivo from various tissue layers within and beneath a murine Meth-A tumor. The spectra differentiated between metabolite levels in tumor tissue and underlying skeletal muscle. Metabolic heterogeneity within the tumor itself was also evident.

Animals

Abnormalities of the liver evaluated by 31P MRS.

Clinical phosphorus-31 magnetic resonance spectroscopy (31P MRS) of the liver requires the use of whole-body magnets and of spectroscopy techniques that acquire signal from defined volumes-of-interest within the liver. Such localization techniques and recent clinical studies are briefly reviewed. These studies indicate that (1) high phosphomonoester levels are present in liver diseases involving structural damage, and (2) that MRS of liver tumors may provide a sensitive and rapid indication of response to cancer therapy. Abnormalities of the liver such as alcoholic liver disease, viral hepatitis, and metastasis were analyzed to determine hepatic acid/base status (pH) and to derive absolute molar concentrations of hepatic phosphorus metabolites rather than metabolite ratios. These parameters allow diagnosis and differentiation of several liver pathologies, suggesting an increasing future role of MRS in medical investigation, clinical diagnosis, and patient treatment.

Adenosine Triphosphate