Applying computer-assisted detection schemes to digitized mammograms after JPEG data compression: an assessment.

RATIONALE AND OBJECTIVES: The authors' purpose was to assess the effects of Joint Photographic Experts Group (JPEG) image data compression on the performance of computer-assisted detection (CAD) schemes for the detection of masses and microcalcification clusters on digitized mammograms. MATERIALS AND METHODS: This study included 952 mammograms that were digitized and compressed with a JPEG-compatible image-compression scheme. A CAD scheme, previously developed in the authors' laboratory and optimized for noncompressed images, was applied to reconstructed images after compression at five levels. The performance was compared with that obtained with the original noncompressed digitized images. RESULTS: For mass detection, there were no significant differences in performance between noncompressed and compressed images for true-positive regions (P = .25) or false-positive regions (P = .40). In all six modes the scheme identified 80% of masses with less than one false-positive region per image. For the detection of microcalcification clusters, there was significant performance degradation (P < .001) at all compression levels. Detection sensitivity was reduced by 4%-10% as compression ratios increased from 17:1 to 62:1. At the same time, the false-positive detection rate was increased by 91%-140%. CONCLUSION: The JPEG algorithm did not adversely affect the performance of the CAD scheme for detecting masses, but it did significantly affect the detection of microcalcification clusters.

Algorithms↗

Preliminary clinical evaluation of a high-resolution telemammography system.

RATIONALE AND OBJECTIVES: The authors designed, assembled, tested, and clinically evaluated a high-quality, fast, and relatively inexpensive telemammography system. METHODS: The authors designed a telemammography system that uses a high-resolution film digitizer and high data compression (> or = 40:1) to send images over regular telephone lines to a high-resolution laser printer that produces images with the look and feel of the original image and can operate in a hub and spokes mode. The authors then evaluated the system's performance. In a preliminary clinical study, interpretations of the laser-printed system's output of 119 cases were compared with the original interpretations, followed by a review of any clinically significant differences. RESULTS: With the exception of the laser printer, which is a modified off-the-shelf product, all hardware components of the system are commercially available products. The system digitizes (50 microns pixel size), compresses, transmits, receives, decompresses, and prints a 30 MB mammography file in less than 4 minutes. In the clinical study, there were 13 differences (in 13 cases) in the level of concern or recommendations. Seven were found to be clinically insignificant by a third-party review. The remaining six were reviewed by the original interpreter, and three were determined to be significant enough for further action. All were found to result from intra-reader variability rather than differences in visualization of possible abnormalities. CONCLUSIONS: Almost real-time, high-quality telemammography without geographic boundaries is possible with the use of high-level data compression. Telemammography with laser-printed film as the display may make it possible to offer mammographic services in remote locations while using commercially available technology.

Evaluation Studies as Topic↗

Joint photographic experts group (JPEG) compatible data compression of mammograms.

We have developed a Joint Photographic Experts Group (JPEG) compatible image compression scheme tailored to the compression of digitized mammographic images. This includes a preprocessing step that segments the tissue area from the background, replaces the background pixels with a constant value, and applies a noise-removal filter to the tissue area. The process was tested by performing a just-noticeable difference (JND) study to determine the relationship between compression ratio and a reader's ability to discriminate between compressed and noncompressed versions of digitized mammograms. We found that at compression ratios of 15:1 and below, image-processing experts are unable to detect a difference, whereas at ratios of 60:1 and above they can identify the compressed image nearly 100% of the time. The performance of less specialized viewers was significantly lower because these viewers seemed to have difficulty in differentiating between artifact and real information at the lower and middle compression ratios. This preliminary study suggests that digitized mammograms are very amenable to compression by techniques compatible with the JPEG standard. However, this study was not designed to address the efficacy of image compression process for mammography, but is a necessary first step in optimizing the compression in anticipation of more elaborate reader performance (ROC) studies.

Algorithms↗

Simultaneous measurements of cerebral blood flow by the xenon/CT method and the microsphere method. A comparison.

Simultaneous measurements of cerebral blood flow have been performed in baboons to assess the correlation between the acute and invasive nondiffusible microsphere technique and the noninvasive xenon-enhanced CT method. Blood flows in small tissue volumes (approximately 1 cm3) were directly compared. The results of these studies demonstrate a statistically significant association between the two methods (P less than .001). Similar correlations were obtained by both the Kendall tau (tau) and the Spearman (r) methods. The problems and limitations of such correlations are discussed.

Animals↗

Stable xenon CT blood flow mapping for evaluation of patients with extracranial-intracranial bypass surgery.

Xenon computerized tomography (Xe CT) blood flow studies were conducted in 25 patients referred for a possible extracranial-intracranial bypass procedure for occlusive vascular disease in one or more extra- or intracranial vessels. These studies were helpful in selecting eight candidates for surgery. The Xe CT studies were performed at one or two brain levels using a prototype Xe CT system for measurement of cerebral blood flow which was designed in collaboration with the General Electric Co., and adapted for the GE 9800 scanner. In those patients selected to undergo operation, Xe CT demonstrated compromise of flow reserve regionally, globally, and/or in the watershed area. All eight patients who underwent the procedure showed a favorable clinical response postoperatively, and seven had a dramatic increase in flow. The 17 patients whose baseline CT studies showed no reduction of flow with the Xe CT method were not selected for surgery. All 25 patients have remained neurologically stable to date. Case studies of three of the eight patients undergoing bypass surgery are presented. This limited but consistent experience suggests that Xe CT blood flow mapping makes possible the recognition of brain regions in which flow reserves are compromised. This is due to the relatively high degree of spatial resolution that this technique provides and to the fact that mapping can be correlated directly with the anatomy. Used in combination with a careful clinical examination and an accurate medical history, this study method appears to be a useful guide in the selection of patients who are most at risk from hemodynamic instability and those who are most likely to benefit from flow-augmentation surgery.

Aged↗

Measurement of cerebral blood flow during xenon inhalation as measured by the microspheres method.

Measurements of cerebral blood flow (CBF) were performed using the microsphere technique in non-human primates (baboons) to assess the effect of non-radioactive xenon gas inhalation on CBF. Blood flows in small tissue volumes (approximately 1 cm3) were directly measured before and during the inhalation of xenon/oxygen gas mixtures. The results of these studies demonstrated that when inhaled in relatively high concentrations, xenon gas does increase CBF, but the changes are more global than tissue-specific. The problems and limitations of such evaluations are discussed.

Animals↗