Clinical services assessment and reengineering: lessons learned.

Healthcare enterprises often "acquire and install" picture archiving and communications systems (PACS) without examining many of the care delivery processes and information flows that will be affected. Many times these unexamined factors can delay or be the cause of failure of the PACS project. This article presents issues that were worked through as part of a PACS clinical services assessment and reengineering analysis for several US military medical treatment facilities.

Alaska↗

The philosophy of benchmark testing a standards-based picture archiving and communications system.

The Department of Defense issued its requirements for a Digital Imaging Network-Picture Archiving and Communications System (DIN-PACS) in a Request for Proposals (RFP) to industry in January 1997, with subsequent contracts being awarded in November 1997 to the Agfa Division of Bayer and IBM Global Government Industry. The Government's technical evaluation process consisted of evaluating a written technical proposal as well as conducting a benchmark test of each proposed system at the vendor's test facility. The purpose of benchmark testing was to evaluate the performance of the fully integrated system in a simulated operational environment. The benchmark test procedures and test equipment were developed through a joint effort between the Government, academic institutions, and private consultants. Herein the authors discuss the resources required and the methods used to benchmark test a standards-based PACS.

Benchmarking↗

Benchmark testing the Digital Imaging Network-Picture Archiving and Communications System proposal of the Department of Defense.

The Department of Defense issued a Request for Proposal (RFP) for its next generation Picture Archiving and Communications System in January of 1997. The RFP was titled Digital Imaging Network-Picture Archiving and Communications System (DIN-PACS). Benchmark testing of the proposed vendors' systems occurred during the summer of 1997. This article highlights the methods for test material and test system organization, the major areas tested, and conduct of actual testing. Department of Defense and contract personnel wrote test procedures for benchmark testing based on the important features of the DIN-PACS Request for Proposal. Identical testing was performed with each vendor's system. The Digital Imaging and Communications in Medicine (DICOM) standard images used for the Benchmark Testing included all modalities. The images were verified as being DICOM standard compliant by the Mallinckrodt Institute of Radiology, Electronic Radiology Laboratory. The Johns Hopkins University Applied Physics Laboratory prepared the Unix-based server for the DICOM images and operated it during testing. The server was loaded with the images and shipped to each vendor's facility for on-site testing. The Defense Supply Center, Philadelphia (DSCP), the Department of Defense agency managing the DIN-PACS contract, provided representatives at each vendor site to ensure all tests were performed equitably and without bias. Each vendor's system was evaluated in the following nine major areas: DICOM Compliance; System Storage and Archive of Images; Network Performance; Workstation Performance; Radiology Information System Performance; Composite Health Care System/Health Level 7 communications standard Interface Performance; Teleradiology Performance; Quality Control; and Failover Functionality. These major sections were subdivided into workable test procedures and were then scored. A combined score for each section was compiled from this data. The names of the involved vendors and the scoring for each is contract sensitive and therefore can not be discussed. All of the vendors that underwent the benchmark testing did well. There was no one vendor that was markedly superior or inferior. There was a typical bell shaped curve of abilities. Each vendor had their own strong points and weaknesses. A standardized benchmark protocol and testing system for PACS architectures would be of great value to all agencies planning to purchase a PACS. This added information would assure the purchased system meets the needed functional requirements as outlined by the purchasers PACS Request for Proposal.

Benchmarking↗

Experience implementing a DICOM 3.0 multivendor teleradiology network.

OBJECTIVE: The ISIS Center at Georgetown University received a grant from the U.S. Army to act as systems integrator for a project to design, develop, and implement a commercial off-the-shelf teleradiology system to support the U.S. troops in Bosnia-Herzegovina. The goal of the project was to minimize troop movement while providing primary diagnosis to military personnel. This paper focuses on Digital Imaging Communications in Medicine (DICOM) 3.0 related issues that arose from this type of teleradiology implementation. The objective is to show that using the DICOM standard provides a good starting point for systems integration but is not a plug-and-play operation. METHODS: Systems were purchased that were based on the DICOM 3.0 standard. The modalities implemented in this effort were computed radiography (CR), computed tomography (CT), film digitization (FD), and ultrasonography (US). Dry laser printing and multiple-display workstations were critical components of this network. The modalities and output devices were integrated using the DICOM 3.0 standard. All image acquisition from the modalities is directly to a workstation. The workstation distributes the images to other local and remote workstations, to the dry laser printer, and to other vendors' workstations using the DICOM 3.0 standard. All systems were integrated and tested prior to deployment or purchase. Local and wide area networking were also tested prior to implementation of the deployable radiology network. RESULTS: The results of the integration of the multivendor network were positive. Eventually, all vendors' systems did communicate. Software configuration and operational changes were made to many systems in order to facilitate this communication. Often, software fixes or patches were provided by a vendor to modify their DICOM 3.0 implementation to allow better communications with another vendor's system. All systems were commercially available, and any modifications or changes provided became part of the vendor's commercially available package. CONCLUSION: Seven DICOM interfaces were implemented for this project, and none was achieved without modification of configuration files, changes or patches in vendor software, or operational changes. Some of the problems encountered included missing or ignored required data elements, padding of data values, unique study identifiers (UID), and the use of application entity titles. The difficulties with multivendor connectivity lie in the understanding and interpretation of standards such as DICOM 3.0. The success of this network proves that these problems can be overcome and a clinically successful network implemented utilizing multiple vendors' systems.