PubMed Health⌕ Search

Biomedical subjects

G Saracino

Publications and source records attributed to G Saracino.

6 recordsLinked to original sources

Sirolimus conversion after liver transplantation: improvement in measured glomerular filtration rate after 2 years.

METHODS: We reviewed our prospectively maintained database of 2005 liver transplantations. Therapy was either started de novo or converted from calcineurin inhibitors (CNIs) to sirolimus as the main immunosuppressive agent for nephrotoxicity or rejection. Glomerular filtration rate (GFR) was determined with iodine 125-labeled sodium isthalamate (Glofil-125), and serum creatinine concentration was obtained before and 3 months after transplantation, and yearly in both groups. Sirolimus levels were 10 to 15 ng/mL in patients at less than 3 months after transplantations and 5 to 10 ng/mL in the remaining patients. All patients received mycophenolate mofetil as maintenance therapy. RESULTS: Data for 29 patients in the de novo group and 35 in the conversion group were reviewed. Patients in the de novo group demonstrated an acute cellular rejection rate of 17.2%, 40% of which were steroid resistant. In this group, 48.2% discontinuation of sirolimus was necessary because of adverse effects. Patients in the conversion group demonstrated an acute cellular rejection rate of 2.8% and a 34.3% rate of sirolimus discontinuation. Seventeen (56.7%) patients at 1 year and 8 (44.4%) patients at 2 years demonstrated continued improvement in GFR. In the conversion group, case-control analysis did not demonstrate a significant difference in GFR and serum creatinine concentration (P > .05) at 1 and 2 years after conversion. At the time of review, no patients in the conversion group required hemodialysis. CONCLUSIONS: Conversion to sirolimus therapy is an effective strategy in improving renal function in patients with CNI-induced nephrotoxicity and can be done without increased rejection. Most of our patients (65.7%) tolerated sirolimus conversion. Of these, 56.7% and 44.4% demonstrated continued increase in GFR with the CNI-free regimen at 1 and 2 years, respectively. Long-term, large-population, prospective, randomized, controlled studies should further validate these results.

Creatinine↗

Modification of the Bu/Cy myeloablative regimen using daily parenteral busulfan: reduced toxicity without the need for pharmacokinetic monitoring.

Pharmacokinetic and clinical outcome measures among three groups of patients undergoing hematopoietic transplant were assessed: group A: Parenteral busulfan (Bu) 3.2 mg/kg i.v. given qd, n=20; group B: parenteral Bu 0.8 mg/kg i.v. given every 6 h, n=11; group C: Bu 1 mg/kg p.o. given every 6 h, n=25. All groups received Bu over 4 days followed by Cy 60 mg/kg i.v. qd over 2 days; followed by an infusion of allogeneic stem cells. Median Bu clearance was 3.21 ml/min/kg and median daily AUC was 4071 micromol/min for the group A patients. The dosing formula for Bu i.v. qd was highly predictive of the AUC for patients whose mass < or =IBW+20%. For patients of greater mass, the dosing formula uniformly resulted in lower-than-predicted AUC. Neurologic toxicity, hepatic toxicity, hematologic engraftment, and relapse at 100 days were comparable across all three groups. Severe AGVHD was least among group A, followed by group B when compared with group C. Bu i.v. qd is a safe and effective regimen for allogeneic transplantation and is at least clinically equivalent to every 6 h dosing schemes using either oral or parenteral Bu.

Administration, Oral↗

Endovascular treatment of a postlaminectomy arteriovenous fistula. A case report.

We report a case of iliac arteriovenous fistula (AVF) following disk surgery. A 51-year-old woman underwent hemilaminectomy for a slipped disk. Two weeks after surgery the patient experienced dyspnea and oedema of the lower limbs. Presence of a systolic murmur on the cardiac floor and on the abdomen was detected and abdomen CT scan which evidenced a AVF between the right common iliac artery and vein. The lesion, confirmed by angiography, was successfully treated with the endovascular technique. The endovascular technique appears to be a valid alternative to the traditional surgical treatment of postlaminectomy AVF.

Arteriovenous Fistula↗

Fast interactive real-time volume rendering of real-time three-dimensional echocardiography: an implementation for low-end computers.

Real-time three-dimensional echocardiography (RT3DE) is an innovative cardiac imaging modality. However, partly due to lack of user-friendly software, RT3DE has not been widely accepted as a clinical tool. The object of this study was to develop and implement a fast and interactive volume renderer of RT3DE datasets designed for a clinical environment where speed and simplicity are not secondary to accuracy. Thirty-six patients (20 regurgitation, 8 normal, 8 cardiomyopathy) were imaged using RT3DE. Using our newly developed software, all 3D data sets were rendered in real-time throughout the cardiac cycle and assessment of cardiac function and pathology was performed for each case. The real-time interactive volume visualization system is user friendly and instantly provides consistent and reliable 3D images without expensive workstations or dedicated hardware. We believe that this novel tool can be used clinically for dynamic visualization of cardiac anatomy.

Artifacts↗

Changes in left ventricular size during parabolic flights by two-dimensional echocardiography and level set method.

This study aims to evaluate changes on cardiac chambers size, induced by gravitational stresses. During parabolic flight, seven subjects underwent 2-D transthoracic echocardiography at three different gravity phases (1 Gz, 1.8 Gz, and 0 Gz). LV endocardial borders were detected applying a semi-automatic segmentation procedure based on level set methods. LV cavity area was computed frame-by-frame for a whole cardiac cycle during each gravity phase. Expected modifications in LV area with different gravity were found: at 1.8 Gz, end-diastolic (ED) and end-systolic (ES) areas were significantly (p<0.05) reduced of 10.7 +/- 5.4% and 21.6 +/- 11.1% respectively, compared to 1 Gz values, while they were increased of 11.2 +/- 5.4% and 11.1 +/- 6% during 0 Gz. Fractional area change was augmented of 20.9 +/- 29.1% at 1.8 Gz, while it remained unchanged at 0 Gz, compared with 1 Gz values. Furthermore, LV filling due to atrial contraction was increased at 0 Gz of 39 +/- 35.6%.

Adult↗

A semi-automatic method for left ventricle volume estimate: an in vivo validation study.

This study aims to the validation of the left ventricular (LV) volume estimates obtained by processing volumetric data utilizing a segmentation model based on level set technique. The validation has been performed by comparing real-time volumetric echo data (RT3DE) and magnetic resonance (MRI) data. A validation protocol has been defined. The validation protocol was applied to twenty-four estimates (range 61-467 ml) obtained from normal and pathologic subjects, which underwent both RT3DE and MRI. A statistical analysis was performed on each estimate and on clinical parameters as stroke volume (SV) and ejection fraction (EF). Assuming MRI estimates (x) as a reference, an excellent correlation was found with volume measured by utilizing the segmentation procedure (y) (y=0.89x + 13.78, r=0.98). The mean error on SV was 8 ml and the mean error on EF was 2%. This study demonstrated that the segmentation technique is reliably applicable on human hearts in clinical practice.

Echocardiography, Three-Dimensional↗