PubMed Health⌕ Search

Biomedical subjects

G Seidel

Publications and source records attributed to G Seidel.

At least 19 recordsLinked to original sources

Patterns of late embryonic and fetal mortality and association with several factors in sheep.

Embryonic and fetal mortality reduce lambing rates and litter sizes, thus contributing to economic losses in the sheep industry. In the current study, the timing of late embryonic and fetal loss in ewes and the factors with which these losses were associated were examined. Ewes lambing and lambs born were compared with pregnancy diagnosis and counts of embryos by ultrasonography near d 25, 45, 65, or 85 of gestation. Approximately 19.9% of the ewes experienced late embryonic loss, fetal loss, or both; and 21.2% of the embryos or fetuses were lost from d 25 to term. Potential offspring were lost throughout gestation; 3.7% of embryos from d 25 to 45, 4.3% of fetuses from d 45 to 65, 3.3% from d 65 to 85, and 11.5% from d 85 to parturition; thus, approximately 3 to 4% of the potential offspring were lost for each 20-d period of pregnancy beyond d 25. A greater proportion of ewes lost one (36.7%) rather than all (20.5% single; 3.8% multiple) embryos or fetuses. The patterns of loss were similar in ewes mated during the anestrous season and the transitional period and did not vary with service period within breeding season or method of synchronization of estrus. Late embryonic or fetal losses were not related to the temperature-humidity index. Maternal serum collected near d 25, 45, 65, or 85 of gestation was assayed for concentrations of progesterone, estradiol-17beta , and vascular endothelial growth factor (VEGF). The proportions of embryos or fetuses lost were associated with breed type (P < 0.05), as were concentrations of progesterone (P < 0.01), estradiol (P < 0.05), and VEGF (P < 0.01). The relationships of loss or retention of pregnancy to hormonal variables at the 4 stages studied were limited. Complete and partial losses increased rapidly as maternal progesterone at d 25 decreased below 2 ng/mL (P < 0.05). Survival of fetuses within a litter from d 25 to 65 was greater for ewes with medium concentrations of VEGF near d 25 and from d 65 to parturition was greater for ewes with high concentrations of VEGF near d 45 (P < 0.05). In summary, late embryonic or fetal losses occurred from d 25 throughout gestation and varied with breed type and with concentrations of progesterone in maternal serum on d 25.

Abortion, Veterinary↗

On the ability of ultrasound parametric perfusion imaging to predict the area of infarction in acute ischemic stroke.

PURPOSE: Cerebral perfusion deficits in acute ischemic stroke can be detected by means of transcranial harmonic imaging after ultrasound contrast agent bolus injection. We evaluated five different parameters of the bolus kinetics as parametric images and correlated areas of disturbed perfusion with the area of definite infarction. MATERIALS AND METHODS: Perfusion harmonic imaging after SonoVue bolus injection (BHI) was used to investigate 22 patients suffering from acute internal carotid artery infarction. For each subject, we calculated five different images based on the following parameters from the time-intensity curve in each pixel: pixelwise peak intensity (PPI), area under the curve (AUC), positive gradient (PG), time to peak (TTP), and a three factor image from the factor analysis of medical image sequences (FAMIS). The findings in the diencephalic imaging plane were compared with the definite area of infarction, as diagnosed by cranial CT. RESULTS: In predicting the definite area of infarction in follow-up CT, we found the following sensitivities and positive predictive values (PPV): PPI (100 %/95 %), AUC (100 %/90 %), FAMIS (89 %/89 %), PG (84 %/94 %) and TTP (47 %/100 %). The areas of disturbed perfusion in all five types of parametric images correlated significantly with the area of infarction in CT. Images from the FAMIS algorithm and PPI images showed the highest Spearman rank correlation with the area of definite infarction as displayed in CT (both r = 0.76, p < 0.001). Images from the other parameters correlated as follows: PG: r = 0.62 (p = 0.003), AUC: r = 0.53 (p = 0.014), TTP: r = 0.50 (p = 0.021). CONCLUSION: BHI can detect disturbed perfusion in acute hemispheric stroke. In their ability to predict the development of an infarction, intensity-based parameters and FAMIS were determined to have a high sensitivity, and TTP was found to have a high PPV and specificity.

Aged↗

Infarction of the right hemisphere in a patient with antiphospholipid antibody syndrome.

Hemicraniectomy as a surgical treatment for intracranial pressure following large ischemic lesions is widely practiced in selected patients. The antiphospholipid antibody syndrome (APS), a disorder characterized by recurrent arterial and venous thrombosis, is a very rare cause of space occupying ischemic lesions. We present a case of a 35 year old female diagnosed with APS who initially presented with small ischemic lesions and within days developed a massive near-total infarction of the right hemisphere. Because of central nervous system, skin and systemic manifestations Sneddon's syndrome and catastrophic antiphospholipid antibody syndrome (CAPS) remained a possible diagnoses. Sneddon's syndrome is a non-inflammatory occlusive arteriopathy of small and medium size arteries predominantly of the skin and brain, whereas the catastrophic antiphospholipid antibody syndrome is characterized by acute multi-organ system thrombosis of small and large vessels. In addition to the diagnostic criteria for APS a heterozygous factor V Leiden mutation was found in this patient, which may be a contributing risk factor for cerebral ischemia. When considering invasive decompressive procedures the neurosurgeon has to be aware of the poor prognosis of some forms of APS with systemic manifestations.

Adult↗

Influence of sward height, daily timing of concentrate supplementation, and restricted time for grazing on forage utilization by lactating beef cows.

To establish the effect of sward height, concentrate feeding time, and restricted time for grazing on forage utilization by grazing cattle, 32 crossbred beef (24 Angus and eight Hereford) cows (632 kg BW) and calves (104 kg BW) were grouped by weight and calving date. They were assigned randomly to two sward height treatments (4 to 8 or 8 to 12 cm), replicated four times. The herbage comprised mainly Kentucky bluegrass, orchardgrass, some forbs, and white clover. The cows were restricted to 12 h/d grazing (0700 to 1900) or unrestricted to 24 h/d grazing and fed a concentrate supplement (4.1 kg DM.cow(-1).d(-1), approximately 0.65% of BW or 33% of total DMI) either at 0700 or 1800. The experiment was repeated over three 15-d periods in May, June/July, and August 2000. The herbage on high sward height pasture was higher (P = 0.06) in NDF and ADF and lower (P < 0.01) in CP than low sward height herbage. For cows restricted to 12 h/d grazing, supplementing at 0700 as opposed 1800 resulted in greater (P = 0.04) forage DMI (8.6 vs. 8.1 kg/d), whereas cows that were unrestricted showed little change (8.2 kg/d at 0700 vs. 8.4 kg/d at 1800). Supplementing at 1800 as opposed to 0700 resulted in greater (P = 0.03) herbage DM digestibility (67.7 vs. 64.5%) for cows on high sward height, whereas cows on low sward height exhibited minimal differences (65.4% at 1800 vs. 66.3% at 0700). Cows restricted to 12 h/d grazing and supplemented at 0700 as opposed to 1800 resulted in greater (P = 0.06) digestible DMI (5.0 vs. 4.7 kg/d), whereas unrestricted cows exhibited the opposite response (4.6 kg/d digestible DMI at 0700 vs. 4.9 kg/d at 1800). Supplementing at 1800 as opposed to 0700 increased the time spent grazing to a greater (P = 0.09) extent for restricted than for unrestricted cows. When forage availability or grazing time was limiting (due to a low forage allowance and restricted access to forage, respectively) supplementing concentrates at 0700 resulted in greater forage utilization and intake rate because of increased forage DMI, DM digestibility, and digestible DMI. However, when forage or grazing time was not limiting, supplementing concentrates at 1800 resulted in greater forage utilization because of increased forage DM digestibility.

Animals↗

Investigations of the production of cephalosporin C by Acremonium chrysogenum.

A review is given on the morphology of Acremonium chrysogenum and the biosynthesis of cephalosporin C based on the published references. Investigations are presented on the comparison of cultivation media carried out by means of shake flask cultures. The process performance of a standard cultivation in well controlled bioreactor is presented and compared with other cultivations, which were executed with the same strain and bioreactor, but with various carbon-, nitrogen- and sulphur-sources keeping the concentrations of the key components at definite levels. Also the influence of dilution and enrichment of the medium on the process performance is explored. Mathematical models for the growth of Acremonium chrysogenum and production of cephalosporin C are reviewed and their application for control of industrial processes with complex cultivation media are discussed.

Acremonium↗

Comparison of flow parameters to analyse bolus kinetics of ultrasound contrast enhancement in a capillary flow model.

AIM: Perfusion harmonic imaging is a new method to evaluate brain perfusion. The purpose of our study was to describe flow by analysing the kinetics of ultrasound contrast enhancement in a flow model after bolus injection of an ultrasound contrast agent (UCA). METHODS: We performed an in-vitro study with an open-circuit flow model and SonoVue(R) given as bolus injection. Bolus kinetics was analysed by harmonic imaging (SONOS 5500, 1.8/3.6 MHz, MI: 1.6) at a fixed frame rate (0.67 Hz). Five different flow rates from 1.8 to 21.6 ml/min were tested. We generated time-intensity curves (TIC) from the grey scale loops. Five parameters (time-to-peak-intensity [TTP], peak-intensity [PI], area under the curve [AUC], positive gradient [PG] and full width at half maximum [FWHM]) were correlated with flow rate. RESULTS: The analysis of both TTP and PG versus flow rate indicated a highly significant linear correlation (r = - 0.96, P <.01; r = 0.91, P = .03; respectively). Neither the AUC (r = - 0.67, P = .22), nor the PI (r = 0.68, P = .20) nor the FWHM (r = - 0.63, P = .37) correlated significantly with flow rate. CONCLUSION: The relationship between TIC parameters and flow rates indicates that, in our flow model, the TTP and PG are the most robust and reliable parameters compared to the AUC, PI and FWHM.

Area Under Curve↗

Human cerebral perfusion analysis with ultrasound contrast agent constant infusion: a pilot study on healthy volunteers.

With ultrasound (US) contrast agent (UCA) continuous infusion providing a steady state, mean tissue microbubble velocity can be assessed by analyzing the reappearance rate after microbubble destruction with US energy (refill kinetics). In this study, we investigated this new approach for the assessment of human cerebral perfusion. A total of 12 healthy volunteers were investigated transtemporally with increasing pulsing intervals (250, 500, 750, 1000, 1250, 1500, 2000, 3000 and 4000 ms) and two UCA infusion rates (0.5 and 1.0 mL/min of Optison). Intensity vs. pulsing interval curves were analyzed using an exponential curve fit and parameters of the curve (plateau echo enhancement, A, representing the microbubble concentration within the interrogated tissue; rate constant, beta, which is related to blood flow and their product, F = Abeta) were compared. For 20/20 investigations being available for further analysis, it was possible to generate a typical exponential intensity vs. pulsing interval curve from the ipsilateral thalamus. The plateau echo enhancement A showed a significant (p = 0.02), and the beta as well as the F values displayed a nonsignificant (p = 0.06, both), increase with infusion rate. The qualitative analysis of beta and F parameter images displayed the most homogeneous visualisation of perfusion in the ipsilateral thalamus and main territory of the middle cerebral artery. In conclusion, it is possible to display the UCA refill kinetics in human cerebral microcirculation after microbubble destruction by transcranial US. Grey-scale harmonic imaging allows a quantitative approach to cerebral perfusion with a large interindividual variation of the parameters.

Adult↗

[Contrast-enhanced intracranial 3 D MR angiography (CE-MRA) in assessing arterial stenoses and aneurysms].

PURPOSE: The aim of this study was to evaluate the diagnostic potential of CE-MR angiography in intracranial arterial stenoses and aneurysms. MATERIAL AND METHODS: Thirteen patients with intracranial arterial stenoses and ten patients with aneurysms, including 6 cases with GDC coil-occluded aneurysms, were examined by both 3 D TOF-MR angiography and CE-MR angiography. In cases of stenoocclusive diseases colour-coded duplex sonography and in cases of aneurysms arterial digital subtraction angiography served as reference method. RESULTS: Both TOF-MRA and CE-MRA could well depict filiform stenosis. In contrast to TOF-MRA, CE-MRA did not show any false positive stenosis or occlusion in regions of turbulent or slow blood flow. Stenoses of the medial cerebral artery could not be graded sufficiently by CE-MRA. In aneurysms the parent vessel was better shown by TOF-MRA. CE-MRA, however, more sensitively detected reperfusion in GDC coil-occluded aneurysms. CONCLUSION: Stenoses of small vessels were graded less exactly by CE-MRA than by TOF-MRA due to lower spatial resolution. CE-MRA, however, seems to be superior in regions of turbulent or slow blood flow. CE-MRA also offers advantages in follow-up examinations of coil-occluded aneurysms.

Aged↗

Circulating microemboli after composite replacement or valve-sparing aortic root surgery.

BACKGROUND: The purpose of this study was to determine whether microembolic signals (MES) occur after valve-sparing operations on the aortic root. One of the advantages of these procedures relates to the freedom of macroemboli without anticoagulation. Whether this holds true for circulating microemboli has not yet been verified. METHODS: For comparison, 8 male patients (mean age: 51.8 +/- 12.8 years) were investigated 20.5 +/- 8.4 months after implantation of a mechanical composite graft (group I) and 9 female and 7 male patients (mean age 55.0 +/- 13.4 years) 23.5 +/- 20.0 months after valve-sparing replacement of the aortic root (group II). The middle cerebral artery was insonated for 2 periods of 30 min, breathing room air or O 2 at 9 l/min. RESULT: Breathing room air, the amount of MES was considerably smaller in group II (0.94 +/- 1.95 vs. 56.1 +/- 58.9 per 30 min, p = 0.006). The difference was less pronounced (0.5 +/- 1.3 vs. 28.9 +/- 42.6 per 30 min, p = 0.009) breathing oxygen. Breathing oxygen reduced MES significantly in group I (p < 0.05) but not in group II (p > 0.05). CONCLUSIONS: Aortic valve-sparing operations induce MES at a significantly lower rate than composite aortic valve replacement using a mechanical valve.

Aorta↗

Feasibility and validity of transcranial duplex sonography in patients with acute stroke.

OBJECTIVES: To evaluate in a prospective multicentre setting the feasibility of transcranial colour coded duplex sonography (TCCS) for examination of the middle cerebral artery (MCA) in patients with acute hemispheric stroke, and to assess the validity of sonographic findings in a subgroup of patients who also had a correlative angiographic examination. METHODS: TCCS was performed in 58 consecutive patients within six hours of the onset of a moderate to severe hemispheric stroke. Ultrasound contrast agent (Levovist) was applied if necessary. Thirty two patients also had computed tomography angiography (n=13), magnetic resonance angiography (n=18), or digital subtraction angiography (n=1). In 14 of these patients, both the sonographic and corresponding angiographic examination were performed within six hours of stroke onset (mean time difference between TCCS and angiography 0.8 hours). Eighteen patients, in whom angiography was carried out more than 24 hours after stroke onset, had a follow up TCCS for method comparison (mean time difference 6.1 hours). RESULTS: Initial unenhanced TCCS performed 3.4 (SD 1.2) hours after the onset of symptoms depicted the symptomatic MCA mainstem in 32 patients (55%) (13 occlusions, one stenosis, 18 patent arteries). After signal enhancement, MCA status could be determined in 54 patients (93%) (p<0.05), showing an occlusion in 25, a stenosis in two, and a patent artery in 27 patients. In 31 of the 32 patients who had correlative angiography, TCCS and angiography produced the same diagnosis of the symptomatic MCA (10 occlusions, three stenoses, 18 patent arteries); TCCS was inconclusive in the remaining one. CONCLUSION: TCCS is a feasible, fast, and valid non-invasive bedside method for evaluating the MCA in an acute stroke setting, particularly when contrast enhancement is applied. It may be a valuable and cost effective alternative to computed tomography and magnetic resonance angiography in future stroke trials.

Acute Disease↗

Indenylidene complexes of ruthenium: optimized synthesis, structure elucidation, and performance as catalysts for olefin metathesis--application to the synthesis of the ADE-ring system of nakadomarin A.

An optimized and large scale adaptable synthesis of the ruthenium phenylindenylidene complex 3 is described which employs commercially available diphenyl propargyl alcohol 5 as a stable and convenient carbene source. Previous ambiguities as to the actual structure of the complex have been ruled out by a full analysis of its NMR spectra. A series of applications to ring closing metathesis (RCM) reactions shows that complex 3 is as good as or even superior to the classical Grubbs carbene 1 in terms of yield, reaction rate, and tolerance towards polar functional groups. Complex 3 turns out to be the catalyst of choice for the synthesis of the enantiopure core segment 77 of the marine alkaloid nakadomarin A 60 comprising the ADE rings of this target. Together with a series of other examples, this particular application illustrates that catalyst 3 is particularly well suited for the cyclization of medium-sized rings by RCM. Other key steps en route to nakadomarin A are a highly selective intramolecular Michael addition setting the quaternary center at the juncture of the A and D rings and a Takai-Nozaki olefination of aldehyde 73 with CH2I2, Ti(OiPr)4 and activated zinc dust.

Journal Article↗

[Harmonic imaging. A new method of ultrasound imaging of brain perfusion].

In this review, methodological aspects of cerebral perfusion imaging with ultrasound contrast agents are described. The various experimental concepts contributing to an understanding of the phenomena are summarised and the resulting investigation techniques on patients are illustrated. By means of harmonic imaging, human cerebral perfusion can be depicted as a two-dimensional scan. The two major principles of contrast measurement are analysis of the bolus kinetics and analysis of the refill kinetics. Using the bolus method, hypoperfused areas in stroke patients can be visualised and parameter images of wash-in and wash-out curves can be generated off-line. The recently developed theory on the refill kinetics of UCA enables us to calculate parameters for describing the cerebral microcirculation, as they are less affected by the depth dependence of the contrast effect. These parameters can also be visualised as images. The ultrasound methods described in this article represent new minimally invasive bedside techniques for analysing brain perfusion. Although their development is still in an early stage, the potential of these ultrasound technologies to compete with perfusion CT, perfusion MRI, and SPECT in the diagnostic arsenal of brain imaging techniques is becoming evident.

Animals↗

Quantification of flow rates using harmonic grey-scale imaging and an ultrasound contrast agent: an in vitro and in vivo study.

It is unclear if the dye-dilution theory and its corresponding parameters are capable of measuring brain perfusion using harmonic grey-scale imaging. We performed a study on a flow phantom using a SONOS 5500 (1.8--3.6-MHz harmonic imaging) and Levovist as the ultrasound (US) contrast agent (UCA). We applied the UCA in six different doses (0.1 to 3.0 mL) and used eight different flow-rates (180 to 540 mL/min). Additionally, we performed a study on dog brain using Levovist boluses of 1.5 mL and 3 mL. We evaluated the influence of dose and flow-rate on the parameters of the time-intensity curve: peak signal intensity (PSI), area under the curve (AUC) and mean transit time (MTT). Along with an increase of the Levovist dose, the AUC and the PSI increased only in the dose range between 0.1 and 0.5 mL Levovist; further increase led to no change of parameters. Flow-rate showed no influence on AUC, MTT or PSI. The dye-dilution theory is not a useful theoretical model for the analysis of perfusion using harmonic grey-scale imaging. A possible explanation for this effect is the bubble saturation.

Analysis of Variance↗

Harmonic imaging of the brain parenchyma using a perfluorobutane-containing ultrasound contrast agent.

We evaluated the signal-enhancing effect of the novel perfluorobutane-based ultrasound contrast agent BR 14 (Bracco Research, Switzerland) in grey-scale harmonic imaging of the brain parenchyma. Six sedated male beagle dogs were investigated with transcranial grey-scale harmonic imaging (SONOS 5500, 1.8/3.6 MHz). After bolus injection of two different doses of BR 14, acoustic densitometry was performed to quantify changes in regional contrast intensity. In the dogs' brain parenchyma, the mean relative peak increase in acoustic intensity was +61% after administration of 0.05 ml/kg BW of BR 14 and +24% after 0.2 ml/kg BW. In the masticatory muscle, application of the higher dose resulted in a stronger increase in contrast intensity compared to the lower dose. Evaluation of the contralateral base of the skull showed a dose-dependent decrease in acoustic intensity. Bolus injection of BR 14 produces an increase in acoustic intensity, which can be used for the visualization of contrast agent in the brain parenchyma. Using high dosages, a strong signal-enhancing effect in the regions near the ultrasound probe leads to a consecutive attenuation of signals from structures being located beyond ("shadowing-effect"). This is the explanation for the paradoxical result that the higher dose leads to a lower peak signal increase in the brain parenchyma.

Animals↗

Evaluation of blood flow in the cerebral microcirculation: analysis of the refill kinetics during ultrasound contrast agent infusion.

By means of harmonic imaging, it is possible to display brain perfusion qualitatively using ultrasound (US) contrast agent (UCA) bolus injection. With UCA continuous infusion reaching a steady state, mean microbubble velocity can be measured, analyzing the reappearance rate after microbubble destruction by US (refill kinetics). We performed an animal pilot study to investigate this new method for the assessment of brain perfusion. Using harmonic grey-scale imaging, five sedated male beagle dogs were investigated through the intact skull with increasing pulsing intervals (250 to 8000 ms) and three UCA infusion rates (0.5, 1.0 and 1.5 mL/min of Optison). Cerebral blood flow was increased by acetazolamide (30 mg/kg BW). Intensity vs. pulsing interval curves were analyzed using an exponential curve fit [I(t) = A(1-e(-beta t))] and parameters of the curve were compared. We found that increasing the pulsing interval above 4000 ms led to no further increase of echo enhancement for infusion rates. Mean beta values were not influenced by infusion rate (p = 0.25 and p = 0.55). Mean F values increased nonsignificantly with rising infusion rate (p = 0.25 and p = 0.86). Acetazolamide led to an increase of mean beta and F values (p = 0.18 and p = 0.025, respectively). It is possible to evaluate changes in brain perfusion through the intact skull by analyzing the UCA refill kinetics after US-induced microbubble destruction.

Albumins↗