PubMed Health⌕ Search

Biomedical subjects

G Senatore

Publications and source records attributed to G Senatore.

At least 19 recordsLinked to original sources

Determinants of efficacy of atrial pacing in preventing atrial fibrillation recurrences.

INTRODUCTION: Several studies have shown that single or dual site atrial pacing is effective in reducing the frequency of recurrent atrial fibrillation (AF) in selected patients. However, it is still unclear what the best predictors are of long-term efficacy of atrial pacing. METHODS AND RESULTS: Forty-seven patients with paroxysmal AF requiring demand pacing underwent electrophysiologic study and dual chamber pacemaker implant. After 4 months of follow-up, patients were divided into two groups according to the presence (group 1) or absence (group 2) of symptomatic AF recurrences. Atrial pacing markedly reduced AF recurrences in all patients. Twenty-four patients were free of arrhythmia. The basal state conduction times (CTs) and the incremental conduction times (ICTs), during programmed electric stimulation between the high right atrium (HRA) and the coronary sinus ostium (CSos), but not between the HRA and the His-bundle region, were significantly longer in group 1. There was no statistical difference in the effective refractory period (ERP) recorded at the HRA, the low right atrium (LRA), and the CSos between the two groups, whereas the differences between the greatest and least recorded ERPs measured from the HRA, LRA, and CSos (deltaERP) were significantly greater in group 1 patients. Two parameters were selected by discriminant multivariate analysis, namely deltaCTos (ICT-CT between HRA and CSos) and deltaERP. The first had a greater relative importance in predicting AF recurrence (r2 = 0.33 and r2 = 0.1, respectively). CONCLUSION: Single site atrial pacing is effective in reducing AF recurrences, with decreasing efficacy in patients with greater right atrial conduction delay and wider refractoriness dispersion.

Aged↗

Feasibility and safety of two French electrode catheters in the performance of electrophysiological studies.

UNLABELLED: The aim of this study was to analyze prospectively the feasibility and safety of using 2 Fr versus 6 Fr standard electrode catheters for diagnostic electrophysiological study. METHODS: Two hundred and five consecutive patients were randomized to receive the 6 Fr approach (3 quadripolar, 6 Fr, electrode catheters inserted through the left or right femoral vein and placed in the high right atrium, right ventricular apex, and His bundle area) or the 2 Fr approach (3 quadripolar, 2 Fr, electrode catheters inserted through a single, 7 Fr, triple lumen, guiding catheter and positioned at the same sites as the 6 Fr approach). RESULTS: Introduction time was shorter in the 2 Fr group (133.3 +/- 65 s, range 87-669 s) than in the 6 Fr group (242.8 +/- 91.8 s, range 168-1024 s, P < 0.001). The overall fluoroscopy time was longer in the 2 Fr group (141.2 +/- 40.1 s, range 78-312 s) than in the 6 Fr group (126.4 +/- 39.7 s, range 58-341 s, P = 0.009). However in the last 100 patients there was no more difference between the two groups (137.6 +/- 28.2 s vs 128.4 +/- 23.2 s, P = 0.07). There was no significant difference between 2 Fr and 6 Fr groups in the mean atrial (5.9 +/- 2.2 mV, range 2.2-11.3 mV, vs 6.1 +/- 2.3 mV, range 2.4-12.4 mV, P = 0.57) and ventricular (5.6 +/- 2.1 mV, range 1.9-9.7 mV, vs 5.7 +/- 2.2 mV, range 2.3-10.5 mV, P = 0.66) activation potential amplitudes recorded during sinus rhythm, or in the rate of stable His bundle potential recording (P = 0.3), and catheter dislodgment (P = 0.54). The overall number of complications was significantly higher in the 6 Fr group than in the 2 Fr group (29 vs 5, P = 0.001), as well as the number of entry site related complications (3 vs 12, P = 0.02) and catheter manipulation related complications (2 vs 17, P < 0.001). CONCLUSIONS: The results of this study show that the use of 2 Fr electrode catheters reduces the rates of entry site and catheter manipulation related complications during EPS. Despite their small size, these catheters allow quick and precise positioning of the electrode.

Cardiac Catheterization↗

Role of catheter-induced mechanical trauma in localization of target sites of radiofrequency ablation in automatic atrial tachycardia.

OBJECTIVES: We compared the efficacy of two different mapping techniques in identifying the ablation site for atrial tachycardia. Moreover, we evaluated the additive positive predictive value of mechanical interruption of atrial tachycardia to reduce the number of ineffective radiofrequency applications. BACKGROUND: Radiofrequency catheter ablation has been suggested as a highly effective technique to treat drug-resistant atrial tachycardia. However, irrespective of the mapping technique utilized, success was most often achieved with a large number of radiofrequency applications. METHODS: Forty-five patients with atrial tachycardia underwent radiofrequency catheter ablation. Mapping techniques included identification of earliest atrial activation and pace-mapping concordant sequence. RESULTS: Atrial tachycardia was successfully treated in 42 (93.3%) of 45 patients with a mean of 3.9 radiofrequency pulses/patient. An interval between the onset of the intracavitary atrial deflection and the onset of the P wave during atrial tachycardia (AP interval) > or = 30 ms (p < 0.001) and pace-mapping concordant sequence (p = 0.01) were all significant predictors of outcome. An AP interval > or = 30 ms and a pace-mapping concordant sequence were highly sensitive (92.8%, 95% confidence interval [CI] 80.5% to 98.5%; 85.7%, 95% CI 71.5% to 94.6%, respectively) but less specific (47.8%, 95% CI 37.9% to 58.2%, 36.8%, 95% CI 27.6% to 47.2%, respectively) in identifying the site of ablation. By using atrial tachycardia mechanical interruption combined with the AP interval >30 ms or the pace-mapping concordant sequence, we obtained a specifically of 76.5% (95% CI 66.4% to 84.0%) and 73.5% (95% CI 63.2% to 81.4%), respectively, and a positive predictive value of 49.2% and 44.6%, respectively. CONCLUSIONS: An AP interval > or = 30 ms and a pace-mapping concordant sequence were reliable mapping features for predicting the outcome of the ablation procedure. Mechanical interruption of atrial tachycardia improved the specificity and positive predictive value of these two mapping techniques.

Adolescent↗

[Radiofrequency catheter ablation of atrial tachycardia: technique, results and follow-up].

BACKGROUND: Recently radiofrequency (RF) catheter ablation (CA) of atrial tachycardia (AT) showed to be highly effective with a low incidence of compliance. Aim of our study was to report the results and follow-up of RFCA of drug-refractory AT in 59 consecutive patients (pts). METHODS: Two mapping techniques were used to localize the ablation site of AT: the earliest atrial activation and the pace-mapping. Traumatic interruption of AT was used to verify the ablation site identified by the previous procedures. Moreover we evaluated the sensitivity, specificity and the positive predictive value of the three mapping techniques. RESULTS: AT was successfully treated in 55/59 (93.2%) pts with a mean of 4.0 +/- 3.8 (range 1-16) RF pulses for patient. The mean procedure time was 185.2 +/- 48.5 min with a mean rx-time of 41.5 +/- 21.3 min. An interval between the onset of the intracavitary atrial deflection and the onset of the P-wave, during atrial tachycardia, (AP interval) > or = 30 ms and pace-mapping concordant sequence were highly sensitive (90.9% and 89.1%) but less specific (49.2% and 33.9%) in identifying the site of ablation. By using atrial tachycardia traumatic interruption combined with the AP interval > 30 ms or the pace-mapping concordant sequence we obtained a specificity of 78.7% and 77.0% respectively and a positive predictive value of 48.0% and 46.8% respectively. Four recurrences (7.3%) were observed during a mean follow-up of 23.4 +/- 13.3 months. In the 22 (37.3%) pts with dilated cardiomyopathy, chest Xr and echocardiography showed a significant decrease of cardiothoracic index (0.56 +/- 0.08 pre ablation, 0.43 +/- 0.07 post ablation, p < 0.001) and end-diastolic diameter (64 +/- 8 mm pre ablation, 52 +/- 8 mm post ablation, p < 0.001) and a significant improvement of left ventricular ejection fraction (37 +/- 9% pre ablation, 48 +/- 11% post ablation, p < 0.05). CONCLUSION: The RFCA of AT was effective and safe. Moreover we observed a hemodynamic improvement in patients with reduced ejection fraction and increased cardiac volumes. An AP interval > or = 30 ms and the pace-mapping concordant sequence were reliable features to predict the outcome of the ablation procedure. Traumatic ablation of atrial tachycardia improved the specificity and the positive predictive value of these two mapping techniques and was able to predict the response to radiofrequency with a high specificity.

Catheter Ablation↗

1,2,3-triazolo[1.5-a]quinazolines: synthesis, benzodiazepine receptor binding and theoretical calculations.

This paper reports the synthesis of 3-substituted-1,2,3-triazolo[1,5-a]quinazolin-5-ones prepared by 1,3-dipolar cycloaddition reaction of 2-azidobenzoic acid to methylenic compounds activated by a cyano group. The new derivatives were submitted to benzodiazepine receptor binding assays: the results indicated an interesting receptorial affinity of the 1,2,3-triazolo[1,5-a]quinazoline ring. On the basis of the biological results, theoretical calculations were performed, which suggested useful structural modifications.

Animals↗

[Computerized follow-up cards for ambulatory patients with implanted pacemaker or defibrillator].

The follow up of pacemaker and defibrillator dependent patients has a significant role for both the evaluation of pacing effectiveness and check of hemodynamic advantages about patient's quality of life. The bulky paper archives are often inaccurate, hampering the consultation. At present the paper card is the only document which can be utilized to record some data concerning the implant and patient clinical story. Therefore, there is the necessity for a card that can include all patient's data, and the implant and programming pacemaker/defibrillator data during follow up. This new pacemaker card has portable file or data-base including shared data with safety mechanism, which can be utilized in several controls by different users (physicians, hospital ward, primary care units, insurance companies). The pacemaker card includes a chip that permits to store a considerable amount of data; it can be update in every further medical control, in observance of laws. The card Chip Operating System (C.O.S.) consists of a microchip with a memory completely managed by the operating system inside the chip itself. The card can be read by means of a GCR-200 modem linked with a PC IBM-compatible computer and the data can be updated during the follow up. The pacemaker-defibrillator card will appear immediately on screen, and it can be printed, updated and/or modified by a Microsoft Windows operating programme. With this pacemaker card we are able to ensure serviceable medical work, particularly in terms of cost/benefit ratio giving to patient more and more reasoning and safe service.

Database Management Systems↗

Structure-activity relationships in a series of 8-substituted xanthines as bronchodilator and A1-adenosine receptor antagonists.

Four new derivatives of 8-piperazine ethyl xanthine were synthesized and their bronchospasmolytic activity and A1-adenosine affinity were studied. Their relaxant action in the tracheal muscle was lower than that of theophylline and that of theophylline derivatives substituted at the 7-position. Only compound 9, where the methyl group in the 1-position of the theophylline was substituted by an isobutyl group, shows a good affinity towards the A1-adenosine receptor.

Animals↗

Synthesis of 3-(2'-furoyl)indole derivatives as potential new ligands at the benzodiazepine receptor, structurally more restrained analogues of indoleglyoxylylamides.

A number of furoylindoles were synthesized with the aim of obtaining structurally more restrained analogues of the previously described indoleglyoxylylamides, which are high affinity ligands at the benzodiazepine receptor. In these new compounds, the oxygen atom of the oxalyl CO(2) is inserted into the rigid furan ring. However, unlike the glyoxylylamides, they proved to be incapable of interacting with the benzodiazepine receptor. To rationalize these results, molecular electrostatic potentials were calculated; these indicated a positive electrostatic potential region for the furan oxygen, which thus prevents the formation of a hydrogen bond necessary for interaction with the receptor. Nevertheless, these findings confirmed that the CO(2) of the indoleglyoxylylamide derivatives represents one of the principal points of interaction with the receptor site for these kinds of ligands, as previously hypothesized by us.

Animals↗

1,2,3-triazole[4,5-d]pyridazines--IV. Preparation and adenosine receptor binding of new 4 and/or 7 aminoderivatives.

This paper reports the continuation of the studies on the 4-aminosubstituted 1,2,3-triazole[4,5-d]pyridazine derivatives which had shown binding affinity towards adenosine receptors. Biological results confirmed the greater activity of a benzyl substituent in the 1 position and the receptorial stereoselectivity related to the higher and more selective A1 affinity of the 4-D(+)-alpha-methylbenzylamino enantiomer 1b. The 4-phenylhydrazino substituent has shown an interesting binding activity about equipotent towards A1 and A2 receptorial sites. A surprisingly elevated A1 affinity (Ki = 7 nM), 440 fold higher than A2 affinity, is presented by compound 1d, bearing a m-toluidino substituent.

Animals↗

8-Azaxanthine derivatives as antagonists of adenosine receptors.

A series of 1,3-dimethyl- and 1,3-dipropyl-8-azaxanthines, substituted at the N8 or N7 position with substituents which usually increase the affinity of the xanthines for the adenosine receptors, was synthesized and studied in radioligand binding experiments. The substitution of CH with N at the 8-position of both theophylline and caffeine dramatically reduced the affinity, as demonstrated by the fact that 8-azatheophylline and 8-azacaffeine were inert. The introduction of a methyl group at 8-position of 8-azatheophylline restored the antagonistic activity at A2 receptors, while a 8-cycloalkyl substituent increased the affinity for both receptor subtypes. A more favorable effect on affinity was produced by the substitution of the 7-methyl group in 8-azacaffeine with cycloalkyl groups. 7-Cyclopentyl-1,3-dimethyl-8-azaxanthine was 3 times more potent than caffeine at A1 receptors and 6 times less active at A2 receptors. On the contrary, the 7-cyclohexyl-1,3-dimethyl-8-azaxanthine was more potent than caffeine at A2 receptors. The substitution of 1- and 3-methyl groups with propyl in both 7- and 8-substituted 8-azatheophylline increased remarkably the affinity for A1 receptors. The 7-cyclopentyl-1,3-dipropyl-8-azaxanthine appears to be one of the most potent and selective among 7-alkyl-substituted xanthines at A1 receptors so far known. Because the 8-aza analogues of 8-substituted 1,3-dialkylxanthine were in any case less active than the corresponding xanthine derivatives, it was confirmed that the hydrogen atom at the 7-position of xanthines plays an important role in the binding to adenosine receptors.

Animals↗

Synthesis and benzodiazepine receptor activity of some 4,5-dihydro-1H-pyrazolo[4,3-c][1,8]naphthyridine derivatives.

The preparation of 5-substituted 1-aryl-4,5-dihydro-1H-pyrazolo[4,3- c][1,8] naphthyridines by reaction of 5-substituted 3-hydroxymethylene-2,3-dihydro-1,8-naphthyridin-4(1H)-ones with various phenylhydrazines is described. The benzodiazepine binding activity of these compounds was evaluated in vitro. Only the 5-methyl substituted derivatives showed affinity for the benzodiazepine receptor, with K1 values ranging from 2.9 to 0.195 microM for the para-phenyl substituted compounds. A hypothesis of interaction of these ligands with the receptor site is reported.

Animals↗

[Atrioventricular conduction before and after the radiofrequency catheter ablation of a nodal reentry tachycardia circuit].

Aim of our study was to retrospectively evaluate atrioventricular conduction 24 hours after selective radiofrequency catheter ablation of the fast pathway or after selective ablation of the slow pathway of the atrioventricular nodal reentrant tachycardia circuit. Electrophysiologic modifications were retrospectively analyzed in 47/48 patients successfully submitted to fast pathway ablation and in 90/93 patients successfully submitted to slow pathway ablation. The atrioventricular conduction intervals (P-Q and A-H), both anterograde and retrograde Wenckebach point, the effective refractory period of atrioventricular node and the atrioventricular node function curve were evaluated before and after selective radiofrequency catheter ablation of slow and fast pathway. We identified the fast pathway ablation potential as: A:V ratio > or = 2:1, His electrogram < or = 150 microV. The slow pathway potential was identified as the widest, sharpest and latest atrial electrogram recorded during sinus rhythm in the posteroseptal region of the atrioventricular junction or as the widest, sharpest and earliest observed during retrograde conduction. We observed a significant increase in the P-Q and A-H intervals in patients submitted to fast pathway ablation, while no significant modification of these parameters was appreciated in patients submitted to slow pathway ablation. No significant modification of anterograde Wenckebach point (NS) was observed in patients submitted to successfully ablation of fast pathway while a statistically significant increase in anterograde Wenckebach point (p = 0.03) was observed in patients submitted to slow pathway ablation. After selective fast pathway ablation, retrograde conduction was absent in 82.9% of patients submitted to ablation; in the remaining 17.1% a significant increase of retrograde Wenckebach point was observed.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

1,2,3-triazole[4,5-d]pyridazines. III--Synthesis of new 4-amino derivatives and their affinity toward adenosine receptors.

This paper describes the preparation and adenosine receptor binding of new 1-benzyl-4-aminosubstituted-1,2,3-triazole[4,5-d]pyridazines and of other 4-aminoderivatives bearing in the 1 position other neutral substituents. The synthetic procedures consist of nucleophilic displacement reactions from the 4-chloro derivative (procedure 1), of displacement of O-sililated intermediates (procedure 2) and of the use of phosphorus pentoxide-triethylamine hydrochloride reagent (procedure 3). The A1 adenosine receptor affinity is confirmed for the 1-benzyl substituted compounds bearing in the 4 position an arylamino or cycloalkylamino group. In addition, the compound obtained by reaction with racemic alpha-methylbenzylamine shows an interesting A1 activity, unlike the 4-benzylamino derivative.

Amines↗