PubMed Health⌕ Search

Biomedical subjects

G Soete

Publications and source records attributed to G Soete.

8 recordsLinked to original sources

Optimal control of set-up margins and internal margins for intra- and extracranial radiotherapy using stereoscopic kilovoltage imaging.

In this paper the clinical introduction of stereoscopic kV-imaging in combination with a 6 degrees-of-freedom (6 DOF) robotics system and breathing synchronized irradiation will be discussed in view of optimally reducing interfractional as well as intrafractional geometric uncertainties in conformal radiation therapy. Extracranial cases represent approximately 70% of the patient population on the NOVALIS treatment machine (BrainLAB A.G., Germany) at the AZ-VUB, which is largely due to the efficiency of the real-time positioning features of the kV-imaging system. The prostate case will be used as an example of those target volumes showing considerable changes in position from day-to-day, yet with negligible motion during the actual course of the treatment. As such it will be used to illustrate the on-line target localization using kV-imaging and 6 DOF patient adjustment with and without implanted radio-opaque markers prior to treatment. Small lung lesion will be used to illustrate the system's potential to synchronize the irradiation with breathing in coping with intrafractional organ motion.

Brain Neoplasms↗

Adjuvant radiotherapy for breast cancer significantly improves overall survival: the missing link.

BACKGROUND AND PURPOSE: The influence of surgical adjuvant radiotherapy on overall survival of patients with operable breast cancer is still a controversial subject. The negative result of the EBCTCG meta-analysis (Early breast cancer trialists', collaborative group. Effects of radiotherapy and surgery in early breast cancer. An overview of the randomised trials. N. Engl. J. Med. 1995;333:1444-1455) of clinical randomized trials on adjuvant radiotherapy in breast cancer is in strong contrast with the Danish 82B, 82C and British Columbia trials (Overgaard M, Hanse PS, Overgaar J, et al. Postoperative radiotherapy in high-risk premenopausal women with breast cancer who receive adjuvant chemotherapy. Danish Breast Cancer Cooperative Group 82b Trial. N. Engl. J. Med. 1997;337:949-955; Overgaard M, Jensen MB, Overgaard J, et al. Postoperative radiotherapy in high-risk postmenopausal breast-cancer patients given adjuvant tamoxifen: Danish Breast Cancer Cooperative Group DBCG 82c randomized trial. Lancet 1999;353:1641-1648; Ragaz J, Jackson S, Le N, et al. Adjuvant radiotherapy and chemotherapy in node-positive premenopausal women with breast cancer. N. Engl. J. Med. 1997;337:956-962) showing an impressive survival benefit. This paper tries to fill in the gap between the conflicting results. MATERIALS AND METHODS: The 36 trials of the EBCTCG (Early breast cancer trialists', collaborative group, 1995) were prospectively screened for a number of objective parameters that are usually not analyzed in review papers. The odds of death data (and its variance) were borrowed from the original meta-analysis (Early breast cancer trialists', collaborative group, 1995) to check whether the objective features were significant predictors for overall survival benefit. RESULTS: A significant survival benefit for the radiotherapy arm was found for recent trials (2P<0.05), large trials (2P<0.03), trials that used standard fractionation (2P<0.02), and trials with a favourable crude survival (2P<0.03). For these four parameters clear parameter-effect relations were found. In recent and large trials the odds reduction was 12.4% (2P=0.004). CONCLUSIONS: Surgical adjuvant radiotherapy significantly improves overall survival of breast cancer patients provided that current techniques are used and treatment is given with standard fractionation. For the best subgroups we observed an odds of death reduction of more than 20%. The results of this study stress the importance of reducing cardiovascular and other late toxicity in adjuvant radiotherapy for breast cancer.

Breast Neoplasms↗

Automatic on-line electronic portal image analysis with a wavelet-based edge detector.

A fully automatic method for on-line electronic portal image analysis is proposed. The method uses multiscale edge detection with wavelets for both the field outline and the anatomical structures. An algorithm to extract and combine the information from different scales has been developed. The edges from the portal image are aligned with the edges from the reference image using chamfer matching. The reference is the first portal image of each treatment. The matching is applied first to the field and subsequently to the anatomy. The setup deviations are quantified as the displacement of the anatomical structures relative to the radiation beam boundaries. The performance of the algorithm was investigated for portal images with different contrast and noise level. The automatic analysis was used first to detect simulated displacements. Then the automatic procedure was tested on anterior-posterior and lateral portal images of a pelvic phantom. In both sets of tests the differences between the measured and the actual shifts were used to quantify the performance. Finally we applied the automatic procedure to clinical images of pelvic and lung regions. The output of the procedure was compared with the results of a manual match performed by a trained operator. The errors for the phantom tests were small: average standard deviation of 0.39 mm and 0.26 degrees and absolute mean error of 0.31 mm and 0.2 degrees were obtained. In the clinical cases average standard deviations of 1.32 mm and 0.6 degrees were found. The average absolute mean errors were 1.09 mm and 0.39 degrees. Failures were registered in 2% of the phantom tests and in 3% of the clinical cases. The algorithm execution is approximately 5 s on a 168 MHz Sun Ultra 2 workstation. The automatic analysis tool is considered to be a very useful tool for on-line setup corrections.

Automation↗

Assessment of the uncertainties in dose delivery of a commercial system for linac-based stereotactic radiosurgery.

PURPOSE: Linac-based stereotactic radiosurgery (SRS) was introduced in our department in 1992, and since then, more than 200 patients have been treated with this method. An in-house-developed algorithm for target localization and dose calculation has recently been replaced with a commercially available system. In this study, both systems have been compared, and positional accuracy, as well as dose calculation, have been verified experimentally. METHODS AND MATERIALS: The in-house-developed software for target localization and dose calculation is an extension to George Sherouse's GRATIS(R) software for radiotherapy treatment planning, and has been replaced by a commercial (BrainSCAN version 3.1; BrainLAB, Germany) treatment planning system (TPS) for SRS. The positional accuracy for the entire SRS procedure (from image acquisition to treatment) has been investigated by treatment of simulated targets in the form of 0.2-cm lead beads inserted into an anthropomorphic phantom. Both dose calculation algorithms have been verified against manual calculations (based on basic beam data and CT data from phantom and patients), and measurements with the anthropomorphic phantom applying ionization chamber, thermoluminescent detectors, and radiographic film. This analysis has been performed on a variety of experimental situations, starting with static beams and simple one-arc treatments, to more complex and clinical relevant applications. Finally, 11 patients have been evaluated with both TPS in parallel for comparison and continuity of clinical experience. RESULTS: Phantom studies evaluating the entire SRS procedure have shown that a target, localized by CT, can be irradiated with a positional accuracy of 0.08 cm in any direction with 95% confidence. Neglecting the influence of dose perturbation when the beam passes through bone tissue or air cavities, the calculated dose values obtained from both TPSs agreed within 1% (SD 1%) for phantom and patient studies. The application of a one-dimensional path length correction for tissue heterogeneity influences the treatment prescription 4% on average (SD 1%), which is in compliance with theoretical predictions. The phantom measurements confirmed the predicted dose at isocenter within uncertainty for the different treatment schedules in this study. CONCLUSION: The full SRS procedure applied to an anthropomorphic phantom has been used as a comprehensive method to assess the uncertainties involved in dose delivery and target positioning. The results obtained with both TPSs are in agreement with AAPM Report 54, TG 42 and clinical continuity is assured. However, the use of a one-dimensional path length correction will result in an increase of 4% in dose prescription, which is slightly more than that predicted in the literature.

Algorithms↗

A feasibility study of high dose rate brachytherapy in solitary urinary bladder cancer.

PURPOSE: To determine the feasibility of high dose rate brachytherapy in the treatment of T1-T3 solitary bladder cancer and to compare results and side-effects to those obtained by others using conventional, i.e., low dose rate regimens. METHODS AND MATERIALS: Between July 1992 and 1995, 16 patients entered the study. Median age at diagnosis was 64 years (range: 45-79 years). Diagnostic transurethral resection showed four T1, five T2, and seven T3 lesions, all proven solitary by random biopsies. Radiotherapy consisted of low-dose preoperative external beam irradiation (3 x 3.5 Gy on the 3 consecutive days prior to implantation), followed by high dose rate brachytherapy (15 x 3 Gy during the 8 consecutive days thereafter). Median follow-up from the date of implantation was 23 months (range: 6-43 months). In 15 patients, cystoscopy was systematically performed during follow-up, whereas the 16th patient was followed on a clinical basis only. RESULTS: Recurrences have occurred in 2 of 15 evaluable patients (both stage T3): metastasis in 1 and combined local plus distant failure in the other patient. Cystoscopic evaluation showed persisting alterations of the implanted portion of the bladder mucosa in 11 of 15 evaluable patients (ulceration, calcifications, and/or punctiform bleedings). Symptomatic radiation cystitis was mild and transient in 14 but persisting and severe in 2 patients. CONCLUSION: This study documents the feasibility of high dose rate brachytherapy in a selected group of bladder cancer patients. Both patient outcome and side-effects are comparable to the best results obtained with low dose rate schedules. Additional follow-up is still needed to enforce the comparison.

Adenocarcinoma↗

Long-term survival in an adult metastatic renal peripheral primitive neuroectodermal tumor (PPNET) with multimodality treatment including high-dose chemotherapy.

We describe a 42-year-old male patient with a primitive peripheral neuroectodermal tumor (PPNET) arising from the kidney. The patient was treated sequentially with surgery, radiotherapy, experimental cytokine treatment (rhIL-6), combination chemotherapy and consolidated in complete remission with high-dose chemotherapy, supported by autologous stem cells (AST) and hematopoietic growth factors. The patient remains in complete remission at 34+ months after AST and is surviving disease-free for five years after initial presentation. The case presented here is unusual because of the renal origin and the long remission duration and survival when compared with the usual outcome of adult metastatic PPNET. High-dose chemotherapy may have favorably influenced the outcome in this patient. The case is discussed in the context of the general treatment of metastatic PPNET.

Adult↗