PubMed Health⌕ Search

Biomedical subjects

G Soldani

Publications and source records attributed to G Soldani.

96 records · Page 6Linked to original sources

The effect of ethanol, beer, and wine on histamine release from the dog stomach.

The mediator for the action of ethanol on the parietal cell of the stomach is not known. However, because the action of ethanol on gastric acid secretion was proposed to involve the release of histamine, we decided to investigate the effects of ethanol and some alcoholic beverages (red wine and beer) on histamine release from the dog stomach. After performing a splenectomy in anaesthetized beagle dogs, the gastrosplenic vein draining the corpus of the stomach was cannulated for blood withdrawal to evaluate the local release of gastrin and histamine by RIA. Intragastric administration of 200 ml of beer (4.8% ethanol) or red wine (12.5% ethanol) caused a significant enhancement in gastrin and histamine concentrations in venous blood from the stomach. By contrast, intragastric administration of pure ethanol in distilled water at the same concentrations of wine or beer did not significantly modify gastrin and histamine release. Integrated histamine responses for 20 min to beer and wine paralleled gastrin concentrations and were of the same magnitude of those induced by intravenous infusion of pentagastrin at 1 and 6 micrograms/ kg/h, respectively. We conclude that: 1) beer and red wine, but not pure ethanol, are potent releasers of histamine; 2) histamine release seems to be related to the gastrin response and probably occurs at the level of enterochromaffin-like (ECL) cells; 3) the ethanol content of these drinks is not important for their stimulant effect, indicating that some other components of beer and wine are responsible for gastrin and histamine release from the dog stomach.

Animals↗

Comparison of HPLC and GC-MS methods for determination of embutramide (a component of Tanax or T-61) in biological specimens.

Tanax or T-61, a euthanasia solution commonly used in veterinary medicine, has been often involved in suicide attempts (humans) and malicious intoxications (animals). For forensic reasons, the identification of one or more of the three components (embutramide, mebenzonium iodide, and tetracaine hydrochloride) of Tanax is needed to confirm the hypothesis of intoxication. This study was performed with new high-performance liquid chromatographic and gas chromatographic-mass spectrometric methods to identify embutramide in biological matrices (blood, liver, kidney) from different animal species. The good sensitivity and specificity of both methods recommend their use in toxicological analysis in both human and veterinary medicine.

Amides↗

Microporous small diameter PVDF-TrFE vascular grafts fabricated by a spray phase inversion technique.

Microporous prostheses of 1.5 mm internal diameter were fabricated with a polyvinylidene fluoride-trifluoroethylene (PVDF-TrFE)n co-polymer by the spray phase inversion technique. Some of the grafts were made piezoelectric by poling under a high electrical field. Overall, 24 poled grafts (P) and 24 unpoled grafts (UP) (15-22 mm in length) were implanted in the infrarenal aorta of 48 adult rats. Patency rates in P were 100% (8/8) at 2 days, 100% (8/8) at 2 weeks, 75% (6/8) at 6 months, and 92% total (22 of 24). Patency rates in UP were 100% (8/8) at 2 days, 63% (5/8) at 2 weeks, 100% (8/8) at 6 months, and 88% total (21 of 24). Thus there was no significant difference in patency between the two types of grafts. Both showed similar macroscopic and microscopic findings. At 2 days, fibrin deposition was somewhat heavier on the poled grafts, but no difference in surface platelet deposition could be detected. Endothelialization was observed from both anastomoses at 2 weeks and was almost complete at 6 months. The excellent biocompatibility of PVDF-TrFE and the microporous structure of the grafts were probably the dominant factors in success with these grafts. Although piezoelectric activity in excised cleaned poled prostheses remained significantly higher than that in the control UP, the charges developed may have been too small to exert a biologic effect, either because of insufficient dipole orientation or inadequate mechanical deformation.

Animals↗

Penetrating micropores increase patency and achieve extensive endothelialization in small diameter polymer skin coated vascular grafts.

This article points to the importance of penetrating micropores through the graft wall to minimize thrombosis and to enhance endothelialization in small diameter polymer skin coated vascular grafts. Four types of spongy polyurethane-polydimethylsiloxane vascular grafts (PUG) fabricated by a spray, phase-inversion technique, 1.5 mm inner diameter, 1.5-1.9 cm in length, were implanted end-to-end in the infrarenal aorta of 26 adult rats. Some had a continuous inner skin and a hydraulic permeability (HP) of 0 ml/min/cm2/ 120 mmHg (PUG-S-O). Some had an inner skin with varying amounts of isolated penetrating micropores and a mean hydraulic permeability of 11 (PUG-S-11), 37 (PUG-S-37), or 58 ml/min/cm2/120 mmHg (PUG-S-58). Twelve PUG-S-O, 6 PUG-S-11, 4 PUG-S-11, and 4 PUG-S-58 were evaluated between 2 hr and 3 months after implantation. All PUG-S-O occluded soon after implantation. The PUG that had a HP of more than 11 ml/min/cm2 showed acceptable patency. However, endothelialization was limited to anastomoses in patent PUG-S-11. In contrast, the patent PUG-S-37 and PUG-S-58 were largely endothelialized. In all patent grafts at 3 months, numerous host cells had migrated, and newly formed capillaries were seen in the voids of the graft wall, which appeared moderately to highly cellular. In conclusion, it appears that penetrating micropores through the graft wall increase patency and that a highly porous structure is needed to achieve extensive endothelialization in small diameter polymer skin coated vascular grafts.

Animals↗

In vivo evaluation of porous versus skinned polyurethane-polydimethylsiloxane small diameter vascular grafts.

Two types of spongy polyurethane-polydimethylsiloxane (PU-PDMS) vascular grafts (1.5 mm ID, 450 microns wall thickness) were fabricated with either a skinned (SG) or a porous (PG) luminal surface and an open mesh filamentous external surface by a spraying, phase-inversion technique. Tubular membranes, 15-20 mm in length, were all implanted by the same surgeon as infrarenal aorta replacements in male Sprague-Dawley rats weighing 250-350 g (SG: n = 12, PG: n = 23). The patency rates at 2 weeks and 3 months were 0% (0/7) and 0% (0/1) for SG, 72% (8/11) and 8% (1/12) for PG. Because the wall structure of these grafts was relatively compact and did not provide enough communicating voids, another series of 15 highly porous luminal surface grafts was fabricated with a higher void to material ratio. These grafts (HPG) exhibited a 73% patency at 3 months, with a fully endothelialized surface. The authors conclude that a very open luminal surface structure, and a high wall porosity, are significant factors of graft patency in small diameter vascular prostheses made of a porous material.

Animals↗