PubMed HealthSearch

Biomedical subjects

G Strata

Publications and source records attributed to G Strata.

10 recordsLinked to original sources

[Spectrum analysis of heart rate variability in obstructive hypertrophic myocardiopathy. Evidence of altered autonomic function].

Altered sympathetic activity may play an important role in the pathogenesis of hypertrophic obstructive cardiomyopathy (HOCM). Spectral analysis of heart rate variability was employed to assess the sympatho-vagal function and balance in 18 patients with HOCM (11 males, 7 females, mean age 42 years, range 19-59) and in 15 healthy control subjects (9 males, 6 females, mean age 44 years, range 18-65). Electrocardiographic recordings obtained both at rest and during 60 degrees passive tilt, were digitized and analyzed by fast Fourier transform in order to obtain the power spectrum of heart rate variability. The low-frequency band (LF: 0.05-0.17 Hz) and the high-frequency band (HF: 0.18-0.34) of power spectrum were considered as indexes of sympathetic and vagal activities respectively. A semiquantitative two-dimensional echocardiographic score (SES) was used to assess the entity of myocardial hypertrophy whereas the entity of the intraventricular gradient was determined by continuous wave Doppler. Low-frequency band at rest was slightly but significantly reduced in HOCM group with respect to controls (35.2 +/- 2.0 vs 45.0 +/- 2.5 nu, respectively; p < 0.01), whereas the HF band and the LF/HF ratio were not different in the 2 groups. During tilt, control subjects showed a significant reduction of the HF band (-35%, p < 0.001), an increase in the LF band (+36%, p < 0.001) and a sharp increase in the LF/HF ratio (+105%, p < 0.001). On the contrary the baroreflex increase in the LF band and LF/HF ratio during tilt was markedly blunted, or even reverted, in patients with HOCM (-9%, NS and +5%, NS, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

[Measurement of the myocardial stimulation threshold in chronic and acute patients with pacemaker implanted (author's transl)].

Eighty-two patients, with electrodes implanted for varying periods of time, have been divided into three groups: acute (at implantation); intermediate (3 to 36 months) and chronic (37 to 124 months). In these groups, respectively 28, 26 and 28 myocardial stimulation threshold measurements have been performed. Measurements have been performed with MEEMR (Myocardial Excitation Energy Meter), an instrument deviced and built by the Institute of Elaboration of Information, CNR and University of Pisa. Microjoule has been chosen as unit of measure. More commonly used units of measure, such as threshold current in milliamp, have been calculated from values in microjoules. Mean values was 0.6 muJ in the first group, 6.9 muJ in the second one and 8.3 in the third one. Student test has been performed on such measurements, divided into groups, with the following results: p less than 0.01 between 1st and 2nd group, non significant difference between 2nd and 3rd group, p less than 0.01 between 1st and 3rd group. Such results suggest a trend toward myocardial threshold stabilization over a long period of time, as had already been hypothized by others Authors. Further useful information may be drawn from these data if they are evaluated in relation to a life-time pacemaker, as is nowadays desirable in view of recent progress in circuit technology and energy sources.

Cardiac Pacing, Artificial

[Stenosis of superior vena cava at the crossing site of two catheters (author's transl)].

A case of superior vena cava syndrome is described in a patient with two endocardial pacing electrodes. At autopsy a severe stenosis of the venous lumen was found at the crossing site of the two catheters. There was no evidence of thrombus formation. Venous wall stenosis is an unusual complication of transvenous pacing and is probably favoured by the presence of two electrodes.

Cardiac Pacing, Artificial