PubMed Health⌕ Search

Biomedical subjects

G Strauss

Publications and source records attributed to G Strauss.

At least 19 recordsLinked to original sources

[Manipulator assisted endoscope guidance in functional endoscopic sinus surgery: proof of concept].

BACKGROUND: Functional endoscopic sinus surgery (FESS) is characterized by single-handed preparation and guidance of the endoscope by the nondominant hand. This results in an additional extension of operation time by up to 15% and ergonomic deficits. The aim of this study is the conception of an automated assistance system for FESS in view of the following questions: (1) Which degree of surgical automation is suitable for FESS? (2) Which design is suitable? (3) What are the properties of the technical system (planning, time, accuracy, precision) of the selected system? (4) Does the system offer potential for a clinical application? METHODS: In all 49 FESS were analyzed for surgical workflows. Measurement of the maximum forces within FESS was performed with 40 trials on an anatomical model. Three different mechanical systems were used in ten FESS and evaluated using the ICCAS Human-Machine Evaluation Scale. For realization of automated endoscope guidance an engine-driven and -braked manipulator (PA10-6c, Mitsubishi, Japan) was used. The technical parameters determined were expenditure of time for the preoperative planning of workspace, surgical accuracy and precision of the intraoperative endoscope positioning, maximal forces, and time. RESULTS: Concept-conditioned instrument changes amount to an average of 41.1 and 18.9% (5.21 min) time requirement for each FESS side. Maximum forces on the mucous membrane during a conventional FESS were measured at 9.8 N (5.9-9.8). Usability of the mechanical endoscope holder was estimated in 18 of 20 cases to be inferior to the standard procedure. The time needed for segmenting the intranasal workspace was 15.2 min (10.0-23.0). The maximum deviation of the automatically driven endoscope from a planned position amounted to 0.85 mm (manually 4.64 mm). The maximum force was measured with 1.1 N in the z direction (manually 9.8 N). Automated guidance of the endoscope to an intranasal position needed 7.25 s (6.4-7.9); manually 12.64 s (5.9-43.0). CONCLUSION: Guidance of the endoscope for FESS by an automated motor-driven system is possible. The conception which is based on workflow analysis favors a system with automatic definition of the workspace and a manual movement of the endoscope. The examined system offers a potential for clinical application. Definition of the automation level and development of a man-machine interface is more important than selection or reconstruction of a special manipulator for endoscope guidance in FESS from a surgical point of view.

Endoscopes↗

Membrane-bound CD95 ligand expressed on human antigen-presenting cells prevents alloantigen-specific T cell response without impairment of viral and third-party T cell immunity.

Genetically modified antigen-presenting cells (APC) represent an attractive strategy for in vitro immunomodulation. In the human system, APC expressing HLA-A1 and a membrane-bound form of CD95L (m-CD95L) were used for selective depletion of HLA-A1-specific T cells. In short-term assays, m-CD95L-expressing APC-induced apoptosis in activated T cells and the constitutive presence of m-CD95L and HLA-A1 expressing APC in long-term T cell cultures prevented the expansion of CD4(+) and CD8(+) HLA-A1-specific T cells and the development of HLA-A1-specific cytotoxicity. However, immunity towards third party, viral and bacterial antigens was maintained and T cells spared from depletion could be induced to develop cytotoxicity towards unrelated antigens. Interestingly, inhibition of HLA-A1-specific T cell response absolutely requires the coexpression of m-CD95L and HLA-A1 antigen on the same APC. Thus, m-CD95L expressing APC might be used in clinical settings to obtain tolerance induction in allogeneic transplantation systems or autoimmune diseases.

Antigen Presentation↗

A non-surgical uterine lavage technique in large cats intended for treatment of uterine infection-induced infertility.

This paper presents the successful use of a non-surgical, transcervical uterine lavage technique for the treatment of uterine infection-induced infertility in three female large cats. We developed a non-surgical uterine lavage technique, which allowed repeated flushing of the uterine lumen and installation of therapeutic antibiotics. The entire procedure was performed under general anaesthesia (duration of anesthesia ranged from 40 to 70 min). It was successfully applied in a Sumatran tiger (Panthera tigris sumatrae), a Corbett tiger (Panthera tigris corbetti) and an Amur leopard (Panthera pardus orientalis). The tigers were treated only once, whereas the leopard received four uterine treatments, due to re-infection after mating. Decisions to conduct uterine treatments were based on detection of uterine fluid during previous transrectal ultrasound examinations. The catheter was guided into the vagina, with the aid of an endoscope, passing the urethra, and then into the uterus, with the aid of transrectal ultrasonography. Both uterine horns were separately flushed with approximately 300 mL of cell medium M199, followed by an antibiotic infusion. Upon ultrasonographic re-examination, the topical uterine treatments resulted in an apparent decline in the inflammatory and/or degenerative processes. The Corbett tiger had the most severe uterine alterations, in addition to an aseptic pyometra. As a result, she was treated 1 month prior to ovariohysterectomy (in order to reduce the surgical risk). The Sumatran tiger was artificially inseminated twice after hormone-induced estrus, and the Amur leopard expressed a spontaneous estrus and re-initiated mating behaviour.

Animals↗

[Improved accuracy and precision of the automated shaver (navigated control) in functional endoscopic sinus surgery].

BACKGROUND: The feasibility of a navigate-controlled Shaver for the paranasal sinus surgery was proven in an initial study. Deficits showed up in the conversion of the planed cavity. Goal of this study is (1) the development and evaluation of a FESS demonstrator for the investigations to the surgical accuracy and (2) the evaluation of the resulting surgical accuracy for registration and conversion of the work space with an improved rigidity of the Shaver and a completely revised study design. METHODS: As a demonstrator for the navigate-controlled resection of a volume through the Shaver a two-piece plastic head with an anatomical head and soft tissue model was designed. The investigation of the surgical accuracy takes place with 417 measurements to 4 different fiducial markers on the demonstrator head. The measurements for the deviation of the resulting cavity from the planned volume was realised with a work space by 24 x 24 x 30 mm. The 5 walls of the cavity were seized with 80 measuring points for each level and thus altogether 2000 measured values (5 models x 5 levels x 200 points). RESULTS: The described demonstrator showed itself suitable for the close-to-application attempts to the surgical accuracy. The maximum deviation A (max) indicated position of the Shaver from the reference value amounted to 1,93 mm. The maximum average value of the exceeding of a planned cavity amounts to 1,62 mm. CONCLUSIONS: Based on these results a virtual safety passage of 2.00 mm is sufficient. The study refers the clinical serviceability of the navigate-controlled Shaver in paranasal sinus surgery.

Equipment Design↗

[Three-dimensional visualization of CT of the neck for surgical planning].

BACKGROUND: Surgical planning in ENT profits from computer assisted preoperative visualization and planning. The informative capability is to be improved by three-dimensional illustrating of the preoperative available data. The possibility of a 3-D-visualization of lymph nodes stands in the center of the interest. METHODS: 16 CT data sets with a tumor-classification of T1N1 or higher were included. Altogether 720 pseudo-3-D-illustrations were provided with an average of 9.3 objects. Current algorithms were used for the segmentation and visualization and the results were divided in three classes. RESULTS: The average time requirement for visualization and segmenting amounted to 122 minutes, the minimum value is at 61 minutes per data set. Automatic segmenting succeeded only with structures with clear grey tone differences to the environment. In all other cases an additional manual interaction had to take place. CONCLUSIONS: 3-D-Visualising of CT of the neck represents a new quality in preoperative planning. A clear trend at increasing detail loyalty and information efficiency showed up in the groups of B and C. It is possible to make from these pictures a quantitative statement on surgery relevant infiltration. Likewise conceivable are the postoperative quality control or planning and process control of a postoperative radio-chemotherapy. The automatic algorithms can be estimated as reliable. Application is still far from a clinically efficient use. With the rising efficiency of the computing systems, the improved software and the imaging systems the problems mentioned are, however, solvable.

Algorithms↗

[Accuracy and precision in the evaluation of computer assisted surgical systems. A definition].

Accuracy represents the outstanding criterion for navigation systems. Surgeons have noticed a great discrepancy between the values from the literature and system specifications on one hand, and intraoperative accuracy on the other. A unitary understanding for the term accuracy does not exist in clinical practice. Furthermore, an incorrect equality for the terms precision and accuracy can be found in the literature. On top of this, clinical accuracy differs from mechanical (technical) accuracy. From a clinical point of view, we had to deal with remarkably many different terms all describing accuracy. This study has the goals of: 1. Defining "accuracy" and related terms, 2. Differentiating between "precision" and "accuracy", 3. Deriving the term "surgical accuracy", 4. Recommending use of the the term "surgical accuracy" for a navigation system. To a great extent, definitions were applied from the International Standardisation Organisation-ISO and the norm from the Deutsches Institut für Normung e.V.-DIN (the German Institute for Standardization). For defining surgical accuracy, the terms reference value, expectation, accuracy and precision are of major interest. Surgical accuracy should indicate the maximum values for the deviation between test results and the reference value (true value) A(max), and additionally indicate precision P(surg). As a basis for measurements, a standardized technical model was used. Coordinates of the model were acquired by CT. To determine statistically and reality relevant results for head surgery, 50 measurements with an accuracy of 50, 75, 100 and 150 mm from the centre of the registration geometry are adequate. In the future, we recommend labeling the system's overall performance with the following specifications: maximum accuracy deviation A(max), precision P and information on the measurement method. This could be displayed on a seal of quality.

Equipment Failure Analysis↗

[Workflow analysis to assess the efficiency of intraoperative technology using the example of functional endoscopic sinus surgery].

Evaluation of the efficiency of surgical technology systems has to date been largely subjective. The aim of this study was to develop an ontology for surgical procedures usable workflow structures, and the evaluation of surgical workflow analysis using the example of functional endoscopic sinus surgery (FESS). A total of 38 procedures (20 patients) were included. Surgery was carried out by seven different surgeons with different degrees of training. Description of the surgical procedures and resources is based on the standard EN1828/2001 (Structure for Classification and Coding Systems for Surgical Procedures). In addition the requirements of the Workflow Reference Models (document no. Tc00-1003), Workflow Management Coalition (WfMC) were integrated. The workflow recorded the position, frequency of change of position, use time, cleaning time and concept based instrument changes. A total of 293 items were used to define FESS. A total of 1,029 different endoscopic positions were documented. These could be combined into five major endoscopic positions. The frequency of position changes was 27.1 per side, the period spent in an endoscopic position is about 1.31 min. Time for the concept-caused instrument changing was 6.44 min per side. This study demonstrates the need for assistance in guiding the endoscope in FESS. Using the workflow-data, the concept of an assistant system is possible. We offer a basis for discussion of the development of an ontology, recording and analysing surgical workflows and their practical application.

Biotechnology↗

[Clinical efficiency and the influence of human factors on ear, nose, and throat navigation systems].

BACKGROUND: The aim of this study was to evaluate the Navibase navigation system for ear, nose, and throat (ENT) surgery. A new methodology for evaluating surgical and human factors is developed. PATIENTS AND METHODS: The evaluation is based on 102 ENT surgical applications, including 89 cases of functional endoscopic sinus surgery (FESS). The evaluation of surgical and human factors was performed by seven ENT surgeons. To evaluate surgical performance, level of quality (LOQ) in the 89 cases of FESS was determined, comparing the surgeon's own impressions with those of the navigation system on a scale from 0 to 100 and further comparing them with clinical results. Intraoperative changes in surgical strategy were documented. The human factors of total confidence (trust), situation awareness, skill set requirement and workload shift were recorded as level of reliance (LOR). RESULTS: The maximum deviation amounted to 1.93 mm. Averaging the quality of information resulted in an LOQ of 63.59. Every second application of the navigation system (47.9%) led to a change in surgical strategy. Total confidence showed a positive evaluation of 3.35 points in LOR. CONCLUSION: Application-relevant information relevant to the application beyond only technical details permits comparison with other assisting systems.

Attitude of Health Personnel↗

Surgery of cavernous malformations with and without navigational support--a comparative study.

BACKGROUND: The aim of this descriptive study was the comparison of the clinical and surgical data of patients who suffered from cavernoma and were treated surgically with and without intraoperative navigation (ultrasound, neuronavigation). METHOD: Between 1995 and 2002, 40 patients were treated for cavernous malformations microsurgically: 24 patients (group I) using a neuronavigation system (STP 4.0, SNN, Germany), 7 patients (group II) using ultrasound (Siemens Omnia with 5.0 MHz Probe) and 9 patients (group III) without any image guidance using anatomic landmarks. FINDINGS: With the use of neuronavigation the mean sizes of cavernous malformations, which were resected, were reduced from 25.6 mm (group III) and 24.4 mm (group II) to 16.3 mm (group I) (p > or = 0.05). Corresponding to the reduction of the cavernoma size, the mean distances of the vascular lesion to the cortical surface increased from 13.9 mm (group III) and 17.8 mm (group II) to 24.4 mm under neuronavigational support (p > or = 0.05). All cavernomas were resected completely in all 40 patients. Postoperative neuroradiological control (MRI) confirmed complete resection in all cases. No significant differences in the clinical outcome could be evaluated in all three groups up to three months postoperatively. CONCLUSIONS: Use of neuronavigation was associated with a more comfortable and safer surgery of smaller and more deeper-seated cavernomas. In spite of the lack of significance between all groups, the advantages of neuronavigation in planning and realising surgery could be documented, which justify the additional costs and time-consuming acquisition of planning image data and postprocessing as well as intraoperative navigation.

Adolescent↗

Establishing navigated control in head surgery.

Navigated Control (NC) describes an additional control for a tracked power driven instrument within a preoperatively segmented work space. In head surgery the authors first implemented NC in functional endoscopic sinus surgery (FESS). Recently the feasibility of NC for surgery on the petrosal bone is evaluated. NC in FESS and in petrosal bone surgery may reduce the risk of comorbidity and the time effort compared to the conventional surgical interventions.

Endoscopy↗

[Mechatronic in functional endoscopic sinus surgery. First experiences with the daVinci Telemanipulatory System].

BACKGROUND: This study examines the advantages and disadvantages of a commercial telemanipulator system (daVinci, Intuitive Surgical, USA) with computer-guided instruments in functional endoscopic sinus surgery (FESS). METHODS: We performed five different surgical FESS steps on 14 anatomical preparation and compared them with conventional FESS. A total of 140 procedures were examined taking into account the following parameters: degrees of freedom (DOF), duration , learning curve, force feedback, human-machine-interface. RESULTS: Telemanipulatory instruments have more DOF available then conventional instrumentation in FESS. The average time consumed by configuration of the telemanipulator is around 9+/-2 min. Missing force feedback is evaluated mainly as a disadvantage of the telemanipulator. Scaling was evaluated as helpful. The ergonomic concept seems to be better than the conventional solution. DISCUSSION: Computer guided instruments showed better results for the available DOF of the instruments. The human-machine-interface is more adaptable and variable then in conventional instrumentation. Motion scaling and indexing are characteristics of the telemanipulator concept which are helpful for FESS in our study.

Clinical Competence↗

[Virtual training in head- and neurosurgery].

BACKGROUND: Surgical skill requires training at close-to-reality scenarios. Conventional procedures (practical exercises, anatomical or animal cadavers) are increasingly in conflict with objective parameters (costs of OR, quality management, cadavers availability and cost). Surgical procedures can be covered by using Virtual Surgical Reality (VSR). METHODS: We examined the principle of a VSR system and evaluated the results with 30 probands by the example of modified radical mastoidectomy and ventriculocisternostomy. Probands were divided in experienced (A) and non-experienced surgeons (B). The protocol included time of surgery, collisions and fatal injuries at altogether 15 passages (10 passages - break of 14 days - 5 passages). Additionally the Medical Level of Trust (LOT) describes the confidence into the surgical scenario and thus the quality by volume illustration, texture and haptic data feedback to the user. We used a numeric scale between 0 and 100 and the starting point of 50. RESULTS: The learning effect can be confirmed for both virtual scenarios. The mastoid scenario reaches a total confidence index LOT of 75. The ventricle scenario is evaluated with a total confidence index of 84. The necessary time for the opening of the antrum is reduced from 15.0 minutes (group A) and 22.5 minutes (group B) around 37 % to 9, 5 (group A) and around 56 % to 10.0 minutes (group B). The virtual haptic result was evaluated positive in both scenarios. CONCLUSIONS: VSR systems have the potential to revolutionize surgical training. All surgical experienced probands evaluated the VSR-scenario as near-to-reality. "Suspension of Disbelief" is the major condition for effective virtual reality training systems.

Clinical Competence↗

[Navigated control: a new concept in computer assisted ENT-surgery].

This work conceived and evaluates a mechatronical system for ORL-surgery by example of a Shaver for Functional Endoscopic Sinus Surgery controlled by navigation. The Shaver is automatically on/off-regulated depending on the current position in relation to the planned working space. This working space is defined on the basis of the individual CT data. Within this area the Shaver reacts to the signal of the surgeon (foot pedal). If the Shaver leaves the working space, an interruption of the drive regulation to the Shaver takes place. The evaluation of the planning software based on 32 patient CT-data sets. The registration accuracy in a anatomical model was examined on 451 measurements of endonasal attached titanium screws. The conversions of the working space were evaluated at 5 different technical models. The average time for segmenting the working space was found at 4.23 minutes per case. An average registration accuracy of the Shaver of 1.08 mm resulted. The pre-defined cavity was to be cleared away without restrictions. The preoperative determined work-space was converted by 3.1 mm over all levels. The study proves the feasibility of a mechatronical assistant system by the example of the navigate-controlled Shaver in paranasal sinus surgery. Contrary to conventional CAS solutions redundancy and cognitive discharge of the surgeon are considered in this conception. We see numerous applications according to the explained principle for power-control of instruments in ORL-surgery in the future such as drilling, high frequency surgery or laser.

Feasibility Studies↗

[Preoperative imaging as the basis for image-guided neurosurgery].

With the progressive development of soft- and hardware, the acceptance of image-guided neurosurgery has increased dramatically. Additional image data are required to analyze the nature and the dimensions of pathological processes and the surrounding tissue. In this context, fMRI, SPECT, PET, as well as special modalities of CT and MR imaging, are routinely used. Secondary post-processing options are used to detect intracerebral lesions as well as adjacent functional eloquent regions in the parenchymatous organ pre- and intraoperatively. The integration of different image information guarantees the precise planning and realization of surgical maneuvers. The segmentation of interesting structures and risk structures, as well as their implementation in the neuronavigation systems, help to avoid additional intraoperative traumatization and offer a higher level of safety and precision. In this article the value and limitations of presurgical imaging will be discussed.

Brain↗

Cavernous malformations--navigational supported surgery.

OBJECTIVE: Navigational supported surgery of intracranial lesions is expected to be associated with a lower rate of brain traumatization as well as an avoidance of additional neurological deficits and surgical morbidity. In our study we used the computer-assisted image guidance for resection of cerebral cavernous malformations. METHODS: In all patients the planning procedure for the following image-guided surgery was realized using preoperative MRl data sets and a neuronavigation system (STP 4.0, SNN). In cases in which the cavernoma was situated near functional eloquent regions, functional MR images were fused preoperatively. RESULTS: During the last 24 months, 21 patients were surgically treated for cerebral cavernoma. No patient was operated twice. The mean size of cavernoma was 18.3 mm, ranging from 5 to 60 mm, the mean distance between cortical surface and cavernoma was 26 mm, ranging from 5 to 50 mm. The surgical procedure lasted in the median 180 min. All patients showed an identical or better neurological outcome. CONCLUSIONS: Neuronavigation allows an accurate definition of the intraoperative target, a correct approach and a safe surgery. With the help of neuronavigation the surgical approach and the extirpation of cavernous malformations were realized in a comfortable and safe way and allowed a minimization of tissue manipulation.

Adolescent↗

[Post-processing of radiological data for preoperative planning in skull base surgery].

Preoperative planning in skull base surgery is usually based on numbers of different radiological data. To use this complex data digital post-processing is necessary. There is a significant difference between radiological and surgical post-processing. Planning the approach, resection of the tumour and reconstruction of the defect are supported by the software demonstrated in this study. Integration of the results in a closed workflow of Information-Guided Therapy will increase the potentials of surgical post-processing in the future (i. e. intraoperative navigation and visualization). Evidence based medicine will use digital data of surgical planning.

Carcinoma, Adenoid Cystic↗

Clinical results in MR-guided therapy for malignant gliomas.

The prognostic impact of the extent of tumour resection in surgery of malignant glioma patients remains controversial. We report the results of cumulative survival of malignant glioma patients operated with MR-guidance. Patients with complete tumour removal were compared with a population of patients with incomplete tumour removal. A 0.5 T scanner was used to criticize the extent of resection during surgery. In total no significant difference could be found, however there is a tendency that complete tumour removal seems to be associated with a slightly increased median survival time.

Adult↗

[Teleteaching in otorhinolaryngology (part 1). Real-time transmission of a congress in picture and tone into the Internet].

The transmission of scientific seminars into the Internet represents a new application of modern technologies for teleteaching. We digitally recorded 74 seminars and discussions during the 8th annual meeting of the German Society of Skull Base Surgery with five cameras and eight microphones, and transformed the data live with the real-Producer using a video card.This transferred data stream was sent via ISDN (128 kbit/s) to a real-server at the university, which was used for distribution in the net. The seminars could be called up in the display format of 320x240 pixels with a delay of 3 min (minimum: 30 s, as a function of the connection of the user) at each computer with Internet entrance. Altogether,we registered 3,284 accesses to the presentations following the congress until June 2002. The quality of picture transmission (24-36 kbit/s) and the quality of tone (audio stream: 5 kbit/s) were sufficient to understand the contents of the slide, video or computer presentation. The transmission of scientific meetings into the Internet can increase, with a justifiable technical expenditure, their efficiency by the ubiquitous availability of the information and the extension of the audience.

Computer Systems↗