PubMed Health⌕ Search

Biomedical subjects

G Strupp

Publications and source records attributed to G Strupp.

7 recordsLinked to original sources

[Induction of myocardial neoangiogenesis by human growth factors. A new therapeutic approach in coronary heart disease].

Currently available approaches for treating human coronary heart disease aim to relieve symptoms and the risk of myocardial infarction either by reducing myocardial oxygen demand, preventing further disease progression, restoring coronary blood flow pharmacologically or mechanically, or bypassing the stenotic lesions and obstructed coronary artery segments. Gene therapy, especially using angiogenic growth factors, has emerged recently as a potential new treatment for cardiovascular disease. Following extensive experimental research on angiogenic growth factors, the first clinical studies on patients with coronary heart disease and peripheral vascular lesions have been performed. The polypeptides fibroblast growth factor (FGF) and vascular endothelial growth factor (VEGF) appear to be particularly effective in initiating neovascularization (neoangiogenesis) in hypoxic or ischemic tissues. The first clinical study on patients with coronary heart disease treated by local intramyocardial injection of FGF-1 showed a 3-fold increase of capillary density mediated by the growth factor. Also, angiogenic growth factor injection intramyocardially as sole therapy for end-stage coronary disease showed an improvement of myocardial perfusion in the target areas as well as a reduction of symptoms and an increase in working capacity. Angiogenic therapy of the human myocardium introduces a new modality of treatment for coronary heart disease in terms of regulation of blood vessel growth. Beyond drug therapy, angioplasty and bypass surgery, this new approach may evolve into a fourth principle of treatment of atherosclerotic cardiovascular disease.

Angiogenesis Inducing Agents↗

Detection of ventricular fibrillation in implantable defibrillators with automatic gain control amplifiers: effects of programming sensitivity.

AIMS: In newer implantable cardioverter-defibrillators with automatic gain control amplifiers the maximum possible sensitivity is programmed with the aim of securing optimal detection of ventricular fibrillation. This study was designed to prove that a reduction in maximum sensitivity is safe with respect to appropriate sensing of ventricular fibrillation, while avoiding sensing of extracardiac signals. METHODS AND RESULTS: Forty-two consecutive patients, undergoing defibrillator implantation/replacement with programmable maximum auto-gain sensing sensitivity (Ventak Mini III, Ventak AV , Guidant, St. Paul, MN, U.S.A.), were prospectively investigated. Thirty-four patients were implanted with a dual-coil lead system, providing integrated bipolar sensing (Endotak, Guidant, St. Paul, MN, U.S.A.), eight patients received a single-coil lead system with true bipolar sensing (Sprint, Medtronic, Minneapolis, MN, U.S.A.). During device implantation and pre-discharge testing, arrhythmia detection times of induced ventricular fibrillation were compared at programmed maximum (0.18 mV) and minimum (0.43 mV) sensitivity in a randomized manner. Seventy-six induced episodes of ventricular fibrillation were analysed. The mean arrhythmia detection times did not differ between the programmed sensing levels (maximum sensitivity: 1612 +/- 307 ms, vs minimal sensitivity: 1,602 +/- 330 ms; P = ns). The results were not affected by the type of implanted lead system (integrated bipolar versus true bipolar sensing). CONCLUSION: In the implantable defibrillator devices, reduction in maximum sensitivity did not impair the detection of induced episodes of ventricular fibrillation.

Amplifiers, Electronic↗

[Papillary muscle rupture during stress ECG after myocardial infarct].

The case of a 57 year old patient is reported, who suffered from an acute myocardial infarction with maximum CK and CKMB values of 821 and 84 U/l, respectively. The patient underwent bicycle exercise testing 9 days after a myocardial infarction in 25 W steps every 2 min starting with 50 W. The ergometry was interrupted at 125 W because of ST segment depression of 0.28 mV in V6. Systolic blood pressure dropped to 55 mm Hg, combined with severe angina and shock. Volume substitution and catecholamines did not elevate blood pressure. Immediate M-mode and Doppler echo revealed a "stiletto"-shaped mitral regurgitation profile typical of acute mitral valve insufficiency. The transesophageal echocardiogram showed a distinct mass moving between the left ventricle and left atrium, diagnostic of papillary muscle rupture. Despite of shock, mitral valve replacement was performed successfully. To our knowledge, this is the first report of a papillary muscle rupture during exercise testing after myocardial infarction. Papillary muscle rupture can be induced by exercise. This fateful event may not be predicted by the course of the ergometry. In case of hypotension during exercise, papillary muscle rupture should be considered. The diagnosis is to be established by transesophageal echocardiography.

Echocardiography, Doppler↗

Comparison of saruplase and alteplase in acute myocardial infarction. SESAM Study Group. The Study in Europe with Saruplase and Alteplase in Myocardial Infarction.

Four hundred seventy-three patients with acute myocardial infarction (AMI) were treated with either saruplase (80 mg/hour, n = 236) or alteplase (100 mg every 3 hours, n = 237). Comedication included heparin and acetylsalicylic acid. Angiography was performed at 45 and 60 minutes after the start of thrombolytic therapy. When flow was insufficient, angiography was repeated at 90 minutes. Coronary angioplasty was then performed if Thrombolysis In Myocardial Infarction (TIMI) trial 0 to 1 flow was seen. Control angiography was at 24 to 40 hours. Baseline characteristics were similar. Angiography showed comparable and remarkably high early patency rates (TIMI 2 or 3 flow) in both treatment groups: at 45 minutes, 74.6% versus 68.9% (p = 0.22); and at 60 minutes 79.9% versus 75.3% (p = 0.26). Patency rates at 90 minutes before additional interventions were also comparable (79.9% and 81.4%). Angiographic reocclusion rates were not significantly different: 1.2% versus 2.4% (p = 0.68). After rescue angioplasty, angiographic reocclusion rates of 22.0% and 15.0% were observed. Safety data were similar for both groups. Thus, (1) early patency rates were high for saruplase and alteplase treatment, (2) reocclusion rates for both drugs were remarkably low, and (3) complication rates were similar. Thus, saruplase seems to be as safe and effective as alteplase.

Aged↗

[Quality assurance in PTCA].

The special need for quality assurance in PTCA results from increasing numbers of procedures, which are due to the prevalence of disease, high primary success rates, progressive simplicity of the basic procedure, but guaranteed financing in Germany. Quality assurance programs first have to take into account the procedural quality, which includes preparation, performance, result, and also overall appropriateness (the indication) of PTCA, and secondly, the structural quality, including personnel, organization, cardiac laboratory facilities and technical equipment. In spite of numerous publications addressing special issues relating to PTCA, these items have been largely neglected in research, and it is uncertain which parameters and methods are meaningful for the improvement of clinical quality and effectiveness. Two examples for general and for internal quality control are demonstrated. In a first extensive quality assurance project of the ALKK study group, all PTCA procedures of a complete group of hospitals are prospectively registered on an intention-to-treat basis, data are controlled by visiting monitors, and appropriateness is examined in a representative sample of procedures by evaluating complete patient files. As an example for an internal quality control system a software program (CLAIM, cardiac laboratory angiography investigation management) is presented. The program yields clinical data but also investigator-related parameters such as fluoroscopy time, investigation time, contrast use, balloon consumption, etc.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[Coronary stent implantation: infection and abscess with fatal outcome].

We report a case of coronary stent-implantation using a Palmaz-Schatz-stent in the right coronary artery (RCA) of a 66-year old woman. Coronary stenting was performed following local dissection and high-grade stenosis after PTCA. Following stent thrombosis re-PTCA was successful, but within 4 weeks progressive reduction of the patient's general condition, plus leucocytosis, subfebril temperatures, and a pericardial effusion occurred. Transesophageal echocardiography documented a perivascular myocardial abscess near the RCA stent; puncture demonstrated pericardial empyema. Emergency cardiac operation was done with segmental resection of the destructed RCA, stent explantation, and CABG to the peripheral RCA, but the patient died. To our knowledge, this is the first case of stent infection reported in the international literature. Transesophageal echocardiography was very helpful in diagnosing this fatal complication of coronary stenting.

Abscess↗

[Acute and intermediate clinical and angiography results after coronary stent implantation].

The value of stenting in emergency situations in interventional angioplasty procedures is widely accepted. Stenting remains controversial as a therapeutic method for use beyond the acute phase, as the results reported in the acute phase are characterized by a wide range. This study reports the implantation results of Palmaz-Schatz stents in 64 cases mostly for failed PTCA. Stents were mounted on Monorail-PVC-balloon catheters. The acute success rate was 96.8%. In two cases with stent misplacement CABG was performed within 48 h. No lethal events occurred in the acute phase. Stent thrombosis has only been seen in four cases (6.5%) so far under subtle monitoring of the anticoagulant regime. Restenosis rate (definition: NHLBI-4) according to serial angiography 6 and 12 weeks after implantation was 4.25% at 6 weeks, with a cumulative rate of 19.4% up to 12 weeks. All recurrences eligible for PTCA have been successfully redilated. A high extracardiac complication rate--predominantly groin hematoma--is the main disadvantage of the procedure. Surgical repair was necessary in 11.4% up to 6 weeks after implantation. Surprisingly high was also the incidence of hematuria, also in 11.4%, in the phase of high anticoagulation. In conclusion, stenting is an effective therapeutic method to avoid emergency CABG and elective CABG in most cases of failed PTCA.

Adult↗