PubMed Health⌕ Search

Biomedical subjects

G Timberlake

Publications and source records attributed to G Timberlake.

11 recordsLinked to original sources

Monitoring gastrointestinal intraluminal PCO2: problems with airflow methods.

UNLABELLED: Gastrointestinal intraluminal PCO2 (PiCO2) information is used to assess the adequacy of trauma patient resuscitation and to assist in choosing resuscitative interventions. Therefore, determining the limitations and potential caveats of different PiCO2 monitoring systems is clinically important. This study compared two PCO2 monitoring systems. The airflow device adds and then removes air samples to quantitate PCO2, whereas the fiber-optic device does not. METHODS: Airflow (TRIP Tonometer/Tonocap) and fiber-optic (Neotrend) systems were used. In vitro they were compared with each other and to two end-tidal CO2 monitors measuring the PCO2 of humidified air containing 5% and then 10% CO2. In vivo the two systems' catheters were surgically juxtaposed in 15 dogs' stomachs; paired PiCO2 readings were taken throughout hemorrhage and resuscitation. RESULTS: In vitro, paired PCO2 values from the airflow and fiber-optic devices correlated with each other (r = 0.99) and with end-tidal values (r = 0.99 with airflow, r = 0.95 with fiber-optic). In vivo, paired values differed significantly (P < 0.0001), correlating poorly for two devices simultaneously measuring the same variable (r = 0.61). Fiber-optic PiCO2 values were higher than airflow values (mmHg +/- SEM): 69.3 +/- 4.8 vs. 61.3 +/- 5.6 at the start of hemorrhage, 141.3 +/- 12.9 vs. 87.7 +/- 7.9 by end of hemorrhage, and 104.3 +/- 9.6 vs. 82.8 +/- 7.0 by end of resuscitation for fiber-optic and airflow, respectively. CONCLUSIONS: Despite agreement in vitro, airflow methods can influence PiCO2 values obtained in vivo. Passive sensing methods used to monitor PiCO2, such as fiber-optic methods, are preferable because they neither deliver O2 to, nor remove CO2 from the local microenvironment.

Animals↗

Car surfing: an uncommon cause of traumatic injury.

Car surfing is an infrequent cause of traumatic injuries treated by emergency physicians. This very dangerous activity can result in serious injury or death. We report 5 cases of injuries caused by car surfing seen at our hospital during 1996 and 1997. All involved head injuries after a fall from a moving motor vehicle. There were 3 male and 2 female patients, and 3 cases were fatal. Health care providers should be aware of this type of injury and support efforts to prevent it.

Accidents, Traffic↗

Preventive antibiotic usage in traumatic thoracic injuries requiring closed tube thoracostomy.

OBJECTIVE: To evaluate the safety and effectiveness of antibiotics in reducing the infectious complications following closed tube thoracostomy for isolated chest trauma. DESIGN: Double-blind, randomized clinical trial. SETTING: Medical school affiliated large urban teaching hospital and trauma center. PATIENTS: One hundred nineteen of 159 patients over 18 years old presenting to the emergency department requiring closed tube thoracostomy for isolated chest injuries (113 penetrating, 6 blunt). INTERVENTION: Patients received either placebo or 1 g cefonicid daily intravenously started at chest tube insertion and stopped within 24 h of removal. MEASUREMENTS AND RESULTS: The development of wound infections, pneumonia (CDC criteria), or empyema; the incidence of adverse events; length of hospitalization. One nonspecific infection was seen in the cefonicid group (1.6 percent) and six respiratory tract infections (10.7 percent) in the placebo group (three empyema, one empyema with pneumonia, two pneumonia) (p = 0.0505; p = 0.0094 [excluding nonspecific infection]). No significant differences with antibiotic use were seen in the duration of chest tube use (p = 0.766), peak WBC counts (p = 0.108), lower peak temperatures (p = 0.063), or length of hospitalization (p = 0.165). Patients who developed infectious complications averaged approximately 8 days longer hospitalization than those without (p < 0.0001). CONCLUSION: This study showed that patients receiving antibiotics had a significantly reduced rate of infection than did patients administered placebo. No significant adverse events were seen in either group.

Adolescent↗

Corneal light scattering and visual performance in myopic individuals with spectacles, contact lenses, or excimer laser photorefractive keratectomy.

Corneal transparency and visual performance are currently receiving much attention after excimer laser surgery. To date, emphasis has been on comparison of eyes on which laser surgery has been performed to eyes with emmetropia. A more appropriate comparison should be between eyes on which laser surgery has been performed and eyes with other forms of correction for myopia. Forward-scattered light, back-scattered light, and visual acuity were investigated and data were collected from 35 myopic individuals with various types of correction for myopia (spectacles, hard and soft contact lenses, and excimer laser surgery). Forward-scattered light was measured by using a new computerized technique, back-scattered light was measured with a charge coupled device-camera system, and visual acuity was measured with a computerized system at various levels of contrast. Spectacles, hard contact lenses, and excimer laser surgery are all superior to soft contact lenses in terms of light scatter and low-contrast visual acuity and excimer laser photorefractive keratectomy produces comparable results to spectacles one year postoperatively. At low-contrast visual acuity, mean visual acuity was 2.45 minutes of arc for the spectacle wearers, 3.21 minutes of arc for the hard contact-lens wearers, and 5.04 minutes of arc for the soft contact-lens wearers. Excimer laser patients had a mean visual acuity of 9.04 minutes of arc three months postoperatively, and 2.53 minutes of arc after one year. A mean value of 2.4% contrast for forward light scatter was obtained for spectacle wearers compared with a level of 3.84% contrast for hard contact-lens wearers and 16.1% contrast for soft contact-lens wearers. The mean value for excimer laser patients was 20% contrast three months postoperatively and 2.1% contrast one year postoperatively.

Contact Lenses↗

Medical complications of head injury.

There are many common and significant medical complications of head injury. These include (1) cardiovascular problems such as hyperdynamic state, myocardial injury, and dysrhythmias; (2) respiratory changes such as neurogenic pulmonary edema, hypoxia, abnormal ventilatory patterns, pulmonary infections, and pulmonary emboli secondary to deep vein thrombosis; (3) consumption coagulopathy; (4) water and electrolyte derangements--hypo- and hypernatremia; (5) hypothalamic/pituitary dysfunction--syndrome of inappropriate secretion of antidiuretic hormone and diabetes insipidus; (6) increased general metabolism with loss of immunocompetence, respiratory compromise, and complications of decreased activity; (7) gastrointestinal difficulties, particularly stress gastritis; and (8) infectious problems including those related to contamination from open wounds and foreign bodies such as monitors.

Cardiovascular Diseases↗

[Corneal opacity after photorefractive keratectomy with an excimer laser. Cause, objective measurement and functional consequences].

A marginal loss of corneal transparency or 'haze' is a phenomenon commonly experienced after photorefractive keratectomy using excimer lasers (193 nm). The putative causes of this phenomenon are the presence in the surgical site of (1) activated keratocytes, (2) vacuoles and (3) newly synthesized collagen. A CCD camera device was employed in order to measure the corneal transparency. Both scattered and reflected light in the slit image of patients' corneas was measured using polarizing filters and image analysis software. We observed an increase in reflected and scattered light until the second postoperative month, followed by a subsequent decline. However, the combined signal generated by reflected and scattered light showed a second increase at 4 months postoperatively, whereas the signal generated by scattered light alone stayed at lower levels. These objective measures of changes in corneal transparency were correlated with changes in visual performance using psychophysical tests measuring visual acuity at different contrast levels (100%, 20% and 5%). In all patients we observed a good correlation between the signal generated by scattered light alone and the reduction in the 5% contrast visual acuity performance. These disturbances in low contrast visual performance were only significant during the first 3-4 months postoperatively, and thereafter most patients returned to their preoperative value. Eighteen percent of our patients discontinued topical steroids postoperatively. No difference in corneal transparency was observed.

Adult↗

[Scanning laser ophthalmoscopy. Its value in macular diseases].

The scanning laser ophthalmoscope provided a high quality television image of the fundus with minimal illumination of the retina. This new device based on a totally new electro-optical principle allowed a detailed exploration of macular function directly under simultaneous fundus control. The focused beam of a yellow krypton laser (568,2 nm) was swept up and down, rights and links across the fundus to form a raster of parallel lines on the retina. The S.L.O. illuminated only a single retinal point at a time and illumination was reduced to less than 70 microw/cm2 versus 100,000 microns/cm2 for indirect ophthalmoscopy and 4,000,000 microw/cm2 for fluorescein angiography. The intensity of the laser beam could be modified with the microcomputer by means of an acousto-optic modulator. It was possible to produce static or dynamic graphic designs that were simultaneously viewed by the patient and observed by the examiner on the patient's fundus on the video monitor. Further computerized analysis of the videotaped scanning laser ophthalmoscopic images gave a functional retinal map with correction for shifts of stimulus position due to fixational saccadic eye movements. The map showed true retinal location of 1. fixation area; 2. scotoma. The clinical evaluation was completed with 3. measurement of visual acuity in any foveal or parafoveal location. The results of scanning laser ophthalmoscopy were illustrated with the report of datas in a patient with diffuse retinal pigment epithelial decompensation.

Adult↗

Automation in krypton laser photocoagulation.

Histologic study of lesions produced by krypton red (647.1 nm) and krypton yellow (568.2 nm) laser lights reported here suggests advantages in alternating these two wavelengths in photocoagulation. Selection of the best wavelength to be used in a given location on the retina should result from pre-determined absorbance conditions in that location. The feasibility of the relative measurement of absorbance in different fundus locations by measurement of the relative reflectance is discussed. Instrumentation for these measurements and for switching from one wavelength to the other is described. Instrumentation for the possible expansion of krypton laser applications to clinical problems in the anterior segment also is suggested.

Animals↗