Influence of slaughtering method on some aspects of quality of gilthead seabream and smoked rainbow trout.

The effects of several slaughter methods on the quality of fresh and smoked trout and fresh gilthead seabream were evaluated during storage at 2 degrees C. Electrically stunned trout had slower ATP depletion of raw muscle and lower lipid oxidation in smoked product during storage. Gilthead seabream immersed in an ice slurry (IS group) after the harvest showed a more regular ATP depletion than in fish exposed to CO2. Nevertheless, in the case of the IS group, self-initiated behaviour, response to handling and breathing all ceased only after 15-20 min, whereas carbon dioxide-stunned fish appeared dead after 5 min. However, gilthead seabream group having slower ATP depletion also showed lower lipid oxidation of muscle during storage. In both species this could be due to the rapid conversion of xanthine dehydrogenase to xanthine oxidase induced by the rapid consumption of ATP. Xanthine oxidase, in the presence of redox iron and reintroduced oxygen, can produce hydrogen peroxide and, consequently, hydroxyl radicals.

Adenosine Triphosphate↗

A feasibility study of a solid-state microdosimeter.

A solid-state silicon detector is a challenging device for microdosimetry, mainly because it can provide sensitive zones of the order of a micrometer. Moreover, these detectors are characterized by a high spatial and a good energy resolution. However, they may present some limitations, such as: (i) the minimum detectable energy which is limited by the electronic noise; (ii) radiation hardness; (iii) the geometry of the sensitive volume; (iv) the field-funnelling effect; (v) the non-tissue-equivalence of silicon. This work discusses a feasibility study of a microdosimeter based on a monolithic silicon telescope, consisting of a DeltaE and an E stage-detector, about 1 and 500 microm thick, respectively. Charges are collected separately in the two stage-detectors. The use of the DeltaE stage coupled with a tissue-equivalent converter was investigated as a solid-state microdosimeter. Irradiations with monoenergetic neutrons were performed at the INFN-Laboratori Nazionali di Legnaro (Italy). The field-funnelling effect appears to be negligible from the comparison of the experimental data with the results of Monte Carlo simulations, performed with the FLUKA code. The preliminary results of an analytical approach for the correction for geometrical effects and tissue-equivalence are also presented.

Journal Article↗