PubMed Health⌕ Search

Biomedical subjects

G W Johnson

Publications and source records attributed to G W Johnson.

At least 19 recordsLinked to original sources

Risk management in international manned space program operations.

New, innovative joint safety policies and requirements were developed in support of the Shuttle/Mir program, which is the first phase of the International Space Station program. This work has resulted in a joint multinational analysis culminating in joint certification for mission readiness. For these planning and development efforts, each nation's risk programs and individual safety practices had to be integrated into a comprehensive and compatible system that reflects the joint nature of the endeavor. This paper highlights the major incremental steps involved in planning and program integration during development of the Shuttle/Mir program. It traces the transition from early development to operational status and highlights the valuable lessons learned that apply to the International Space Station program (Phase 2). Also examined are external and extraneous factors that affected mission operations and the corresponding solutions to ensure safe and effective Shuttle/Mir missions.

Humans↗

A microdosimetry chamber for low-energy X rays.

A wall-less proportional counter designed to measure single event spectra produced by low energy X rays is described. The sensitive volume of the counter and the housing are made entirely of non-metallic materials to minimise distortions in the secondary electron spectrum.

Calibration↗

Evaluation of the immunomodulatory effects of the disinfection by-product, sodium chlorite, in female B6C3F1 mice: a drinking water study.

Sodium chlorite is an inorganic by-product of chlorine dioxide formed during the chlorination of drinking water. Relatively little is known about the adverse health effects of exposure to sodium chlorite in drinking water. In this study, we evaluated sodium chlorite's immunomodulatory properties using female B6C3F1 mice and a panel of immune assays that were designed to evaluate potential changes in innate and acquired cellular and humoral immune responses. Female B6C3F1 mice were exposed to sodium chlorite in their drinking water (0, 0.1, 1, 5, 15, and 30 mg/L) for 28 days, and then evaluated for immunomodulation. Overall, minimal toxicological and immunological changes were observed after exposure to sodium chlorite. Increases in the percentages of blood reticulocytes, and the relative spleen weights were both observed at different sodium chlorite treatment levels; however, these increases were not dose-dependent. An increasing trend in the number of spleen antibody-forming cells was observed over the range of sodium chlorite concentrations. This increase was not, however, significant at any individual treatment level, and was not reflected by changes in serum IgM levels. A significant increase (26%) in the total number of splenic CD8+ cells was observed in mice treated with 30 mg/L of sodium chlorite, but not at the other concentrations. Splenic mixed leukocyte response and peritoneal macrophage activity were unaffected by sodium chlorite. Lastly, exposure to sodium chlorite did not affect natural killer cell activity, although a decrease in augmented natural killer cell activity (42%) was observed at the lowest sodium chlorite treatment level. These results suggest that sodium chlorite, within the range 0.1-30 mg/L, produces minimal immunotoxicity in mice.

Adjuvants, Immunologic↗

Intermittent pneumatic compression of legs increases microcirculation in distant skeletal muscle.

Intermittent pneumatic compression has been established as a method of clinically preventing deep vein thrombosis, but the mechanism has not been documented. This study observed the effects of intermittent pneumatic compression of legs on the microcirculation of distant skeletal muscle. The cremaster muscles of 80 male rats were exposed, a specially designed intermittent pneumatic-compression device was applied to both legs for 60 minutes, and the microcirculation of the muscles was assessed by measurement of the vessel diameter in three categories (10-20, 21-40, and 41-70 microm) for 120 minutes. The results showed significant vasodilation in arterial and venous vessels during the application of intermittent pneumatic compression, which disappeared after termination of the compression. The vasodilation reached a maximum 30 minutes after initiation of the compression and could be completely blocked by an inhibitor of nitric oxide synthase, NG-monomethyl-L-arginine (10 micromol/min). A 120-minute infusion of NG-monomethyl-L-arginine, beginning coincident with 60 minutes of intermittent pneumatic compression, resulted in a significant decrease in arterial diameter that remained at almost the same level after termination of the compression. The magnitude of the decrease in diameter in the group treated with intermittent pneumatic compression and NG-monomethyl-L-arginine was comparable with that in the group treated with NG-monomethyl-L-arginine alone. The results imply that the production of nitric oxide is involved in the positive influence of intermittent pneumatic compression on circulation. It is postulated that the rapid increase in venous velocity induced by intermittent pneumatic compression produces strong shear stress on the vascular endothelium, which stimulates an increased release of nitric oxide and thereby causes systemic vasodilation.

Animals↗

Methylene group modifications of the N-(Isothiazol-5-yl)phenylacetamides. Synthesis and insecticidal activity.

It has been shown that oxidation at the alpha-carbon of N-(4-chloro-3-methyl-5-isothiazolyl)-2-[p-[(alpha,alpha, alpha-trifluoro-p-tolyl)oxy]phenyl]acetamide (1) is conveniently brought about using dimethylformamide dimethylacetal to give N-(4-chloro-3-methyl-5-isothiazolyl)-beta-(dimethylamino)-p-[(alpha, alpha,alpha-trifluoro-p-tolyl)oxy]atropamide (2), which has served as a common starting point for a variety of functional group transformations. These transformations were found to proceed in moderate to good yields to give derivatives of 1 that retained much of the efficacy associated with the parent amide and have allowed for an expansion of the SAR to be developed. Examples of enamines, enols, enol (thio)ethers, oximes, and hydrazones were prepared. In particular, the enamines derived from low molecular weight amines and amino acids were most active as broad-spectrum insecticides and were found to be even more active than 1 on root-knot nematode.

Acetamides↗

Nitrous oxide inhalation as an adjunct to intravenous induction of general anaesthesia with propofol for day surgery.

Fifty patients were randomly allocated to receive either a preinduction inhalation with nitrous oxide (50%) in oxygen or fentanyl with preoxygenation, before induction of anaesthesia with propofol. Both groups of patients showed a significant rise in arterial oxygen saturation prior to propofol induction which established similar depths of anaesthesia, determined by the acceptability of the laryngeal mask placement. In the fentanyl group there was a significant period of apnoea after induction, with 40% of the patients being apnoeic for 120s or more and requiring assisted ventilation. Reduction in arterial blood pressure was also more rapid in the fentanyl group compared with the nitrous oxide group. Preinduction inhalation of nitrous oxide (50%) in oxygen appears to be an effective and acceptable method of preoxygenating the patient and augmenting the propofol induction of anaesthesia.

Adolescent↗

Quantitative comparisons of continuous and pulsed low dose rate regimens in a model late-effect system.

PURPOSE: There is increasing interest and usage of pulsed low dose rate (PDR) brachytherapy, in which a single source is shuttled through the catheters of an implant, typically for about 10 min each hour. This study was designed to compare the late effects produced in various PDR regimens with those from the corresponding continuous low dose rate (CLDR) regimens. METHODS AND MATERIALS: A model late-responding system was used, namely, cataract induction in the rat lens. This system has the advantage of being highly quantifiable. The rats eyes were exposed to a total dose of 15 Gy either continuously over 24 h, or with three different PDR regimens, all with the same total dose and overall time. We addressed three questions: (a) are late effects increased when a CLDR regimen is replaced with 10-min pulses repeated every hour? (b) Are late effects increased if hourly 10-min pulses are replaced with 10-min pulses repeated every 4 h? (c) Are late effects increased if 10-min pulses are replaced with 100-s pulses? RESULTS: We found that the four regimens under test, continuous, 10-min pulses each hour, 10-min pulses every 4 h, and 100-s pulses every hour, showed no significant differences in cataractogenic potential, as estimated with the Wilcoxon-Gehan test. Power tests indicated that the experimental design was adequate to detect relatively small differences in cataractogenicity between regimens. CONCLUSIONS: The equality of late effects from CLDR and PDR in these experiments must imply that sublethal damage repair is quite slow in this model late-responding system, in agreement with trends observed in the clinic for sublethal damage repair of late sequelae. Such trends would suggest that PDR is unlikely to produce significantly worse late effects than the corresponding CLDR regimen, which is in agreement with early clinical data using PDR. Caution, however, is strongly recommended.

Animals↗

The endoscopic breast augmentation: the transumbilical insertion of saline-filled breast implants.

Initial aesthetic breast augmentation with inflatable saline implants has always had the distinct advantage of insertion through a small breast or axillary skin incision. Adapting established techniques utilized in suction-assisted lipectomy, operative endoscopy, and tissue expansion with inflatable saline implants, breast augmentation is possible through an umbilical incision. Under general anesthesia, an incision is made in the umbilicus; a new tubular instrument with an obturator [designated an endotube (Johnson) or mammascope (Christ)] is inserted into the umbilical incision like a suction cannula; it is pushed over the abdominal fascia across the costal margin until it literally pops under the breast fascia; through this tunnel is then inserted an implant coiled like a tobacco leaf; the implant is then inflated to 50 percent more than the final volume and manipulated to help expand the pocket; finally, the excess volume is removed, methyl-prednisolone acetate is placed in the final volume, and the fill tube is removed. The endoscope (laparoscope) is utilized to visualize positioning and to document the absence of bleeding. The umbilical incision is closed after insertion of both implants through the same incision. A series of 91 young women have undergone this procedure with 188 breast implantations without significant bleeding. Implants appear to ride high initially, but they settle into place by 6 weeks. Patients have reported less chest discomfort and some visible temporary upper abdominal swelling. The long-term follow-up is currently being monitored.

Adult↗

Radio-frequency ablation: effect of voltage and pulse duration on canine myocardium.

The purpose of this investigation was to examine in vivo the relationship of radio-frequency (RF) pulse voltage and duration on the volume of tissue injury. RF 500-kHz pulses of 20-, 40-, and 60-V amplitude (RMS) were applied to the epicardium of 18 dogs for pulsing periods of 5-20 s. Systematic and quantitative tissue analysis was then performed after 30 days. No chronic lesions were evident on microscopic examination for 20-V RF pulse applications up to 15 s. Application of 20-V pulses for 20 s produced small lesions having a volume of 2.4 +/- 0.7 mm3. At 40 V, the volume of tissue injury ranged from 39.1 +/- 10.3 mm3 for 5 s of pulse application to 128.8 +/- 24.8 mm3 for 20 s of pulse application. Over the first 15 s of 40-V pulse application, the volume of tissue injury increased as pulse application time increased. There was no further increase in tissue injury for 40-V pulsing durations greater than 15 s. At 60 V, volumes of tissue injury ranged from 122.7 +/- 33.5 mm3 at 5 s to 313.6 +/- 73.7 mm3 at 20 s. Lesion size increased significantly for pulse durations of up to 10 s. Thereafter, 60-V pulses yielded little increase in tissue injury. In addition, persistent 60-V pulsing for periods greater than 9 s duration resulted in arcing and tissue vaporization in 28% of the applications. Thus RF energy is limited in its ability to create safe and effective tissue injury.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

A bridge to the community for extended-care state hospital patients.

In early 1988 a discharge assessment team surveyed the records of 421 extended-care patients at Washington's Western State Hospital to facilitate planning for patients who were able to move out of the hospital. The group as a whole manifested serious problem behaviors, both current and past. Less than 40 percent of the patients needed continued state hospital care, but most who could be discharged to the community would require intensive residential supervision and support. The authors review linkages between two kinds of residential treatment programming that exists for this population, a network of community residential treatment facilities operated by private providers and community mental health centers and a hospital-based transitional program called the Program for Adaptive Living Skills. Linkages between these programs have proved useful in the residential placement of extended-care patients.

Adult↗

Selective, stability-indicating assay of the major ipecacuanha alkaloids, emetine and cephaeline, in pharmaceutical preparations by high-performance liquid chromatography using spectrofluorimetric detection.

A selective high-performance liquid chromatographic procedure has been developed for the determination of the major Ipecacuanha alkaloids, emetine and cephaeline, in a number of linctus and pastille preparations. The reversed-phase chromatographic procedure uses an octadecyl-bonded column with a mobile phase of aqueous methanol containing an ion-pairing reagent. A spectrofluorimetric detector is used for increased sensitivity and selectivity. Sample preparation is simple, involving either straight dilution for linctus formulations or simple dissolutions for pastilles. The procedure has been shown to be stability-indicating. Validation studies, to show that the method is precise, accurate and rectilinear, have been carried out on four linctus formulations and two pastille formulations. The method has been used to determine both emetine and cephaeline at levels as low as 5 micrograms/g in formulations.

Chromatography, High Pressure Liquid↗

The prevention of plasticizer migration into nutritional emulsion mixtures by use of a novel container.

The presence of di-(2-ethylhexyl)phthalate in poly (vinyl chloride) has led to concern regarding the potential for plasticizer migration from this widely used material into fluids for infusion, particularly nutritional admixtures containing lipid. A novel container is reported which combines the advantages and versatility of poly(vinyl chloride) without the disadvantage of plasticizer migration into the infused fluid.

Journal Article↗

Correction of refraction and other angle errors in beam tracking speed of sound estimations using multiple tracking transducers.

The beam tracking approach to the estimation of the speed of sound has shown potential for making unbiased estimates in tissues. The speed of sound in a medium can be found from the arrival times of echoes as a function of the position of a tracking transducer. There is a problem in this approach if the angle between the direction of tracked beam and the direction of tracking translation is not zero due to refraction or other effects. An angle error as small as 1 degree would result in an error that is too large for diagnostic applications. A modified technique using three or more tracking transducers is described. This yields a corrected speed of sound estimate, and calculates the angle error. A simulation program has shown that this modified technique could indeed correct for the angle errors.

Computer Simulation↗

Axillobrachial artery bypass grafting with in situ cephalic vein for axillary artery occlusion: a case report.

The cephalic vein has been reported to be a suitable vascular conduit for arterial reconstructive surgery, but its use remains controversial. When used for lower extremity revascularization, its use has been complicated by elongation and dilation. Its use for upper extremity revascularization has only been rarely reported. This article represents the first published use of the cephalic vein with the in situ technique for upper extremity occlusive disease. This technique may avoid some of the complications noted when used in the reverse fashion.

Arm↗

Effect of voltage and charge of electrical ablation pulses on canine myocardium.

Multiple paired lesions produced by a train of high-voltage low-charge rectangular pulses (20 A, 30 microsecond) and a train of low-voltage high-charge rectangular pulses (2 A, 300 microsecond) were made to the left ventricular epicardium of 23 dogs to determine the relative influence of voltage and charge delivery on injury of canine myocardium. Both pulsing methods contained equal amounts of energy (15 J) delivered over equal periods of time (100 ms), and both pulsing methods were nonarcing and therefore nonbarotraumatic. The volume of cardiac tissue injury resulting from both types of pulses was then evaluated from planimetered serial histological sections after 1, 10, and 30 days. Over the 30-day period, lesion size progressively decreased to 56% of its original value for the high-voltage low-charge pulse. In contrast, lesion size from the low-voltage high-charge pulse remained relatively constant, decreasing only 12% of its original value. These results indicate that when energy delivery is held constant, voltage, not charge, is the dominant mediator of cell injury. Also, cells subjected to high voltages appear to recover partially over time with significantly less constancy of tissue injury than that seen with low-voltage high-charge pulses.

Animals↗