PubMed Health⌕ Search

Biomedical subjects

G W Peng

Publications and source records attributed to G W Peng.

At least 19 recordsLinked to original sources

Pharmacokinetics, toxicokinetics, distribution, metabolism and excretion of linezolid in mouse, rat and dog.

1. Linezolid (ZYVOX), the first of a new class of antibiotics, the oxazolidinones, is approved for treatment of Gram-positive bacterial infections. 2. The aim was to determine the absorption, distribution, metabolism and excretion (ADME) of linezolid in mouse, rat and dog in support of preclinical safety studies and clinical development. 3. Conventional replicate study designs were employed in animal experiments, and biofluids were assayed by HPLC or HPLC-MS. 4. Linezolid was rapidly absorbed after p.o. dosing with an p.o. bioavailability of > 95% in rat and dog, and > 70% in mouse. Twenty-eight-day i.v./p.o. toxicokinetic studies in rat (20-200mg kg(-1) day(-1)) and dog (10-80 mg kg(-1) day(-1)) revealed neither a meaningful increase in clearance nor accumulation upon multiple dosing. 5. Linezolid had limited protein binding (<35%) and was very well distributed to most extravascular sites, with a volume of distribution at steady-state (V(ss)) approximately equal to total body water. 6. Linezolid circulated mainly as parent drug and was excreted mainly as parent drug and two inactive carboxylic acids, PNU-142586 and PNU-142300. Minor secondary metabolites were also characterized. In all species, the clearance rate was determined by metabolism. 7. Radioactivity recovery was essentially complete within 24-48 h. Renal excretion of parent drug and metabolites was a major elimination route. Parent drug underwent renal tubular reabsorption, significantly slowing parent drug excretion and allowing a slow metabolic process to become rate-limiting in overall clearance. 8. It is concluded that ADME data were relatively consistent across species and supported the rat and dog as the principal non-clinical safety species.

Acetamides↗

Pharmacokinetics, metabolism, and excretion of linezolid following an oral dose of [(14)C]linezolid to healthy human subjects.

Linezolid (Zyvox), the first of a new class of antibiotics, the oxazolidinones, is approved for treatment of Gram-positive bacterial infections, including resistant strains. The disposition of linezolid in human volunteers was determined, after a 500-mg (100-microCi) oral dose of [(14)C]linezolid. Radioactive linezolid was administered as a single dose, or at steady-state on day 4 of a 10-day, 500-mg b.i.d. regimen of unlabeled linezolid (n = 4/sex/regimen). Mean recovery of radioactivity in excreta was 93.8 +/- 1.1% (range 91.2-95.2%, n = 15), of which 83.9 +/- 3.3% (range 76.7-88.4%) was in urine and 9.9 +/- 3.4% (range 5.3-16.9%) was in feces. There was no major difference in rate or route of excretion of radioactivity by dose regimen. Linezolid was excreted primarily intact, and as two inactive, morpholine ring-oxidized metabolites, PNU-142586 and PNU-142300. Other minor metabolites were characterized by high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry and (19)F NMR spectroscopy. After the single radioactive dose, linezolid was the major circulating drug-related material accounting for about 78% (male) and 93% (female) of the radioactivity area under the curve (AUC). PNU-142586 (T(max) of 3-5 h) accounted for about 26% (male) and 9% (female) of the radioactivity AUC. PNU-142300 (T(max) of 2-3 h) accounted for about 7% (male) and 4% (female) of the radioactivity AUC. Overall, mean linezolid and PNU-142586 exposures at steady-state were similar across sex. In conclusion, linezolid circulates in plasma mainly as parent drug. Linezolid and two major, inactive metabolites account for the major portion of linezolid disposition, with urinary excretion representing the major elimination route. Formation of PNU-142586 was the rate-limiting step in the clearance of linezolid.

Acetamides↗

Determination of linezolid in plasma by reversed-phase high-performance liquid chromatography.

An HPLC-UV method was developed for assay of linezolid in dog, rat, mouse, and rabbit plasma. Linezolid and the internal standard were extracted on a solid phase cartridge (SPE) and separated on a reversed-phase column (C8, 4.6x150 mm, 5 microm) with 20% acetonitrile in water as mobile phase. The SPE quantitatively recovered linezolid and the internal standard from plasma samples. The chromatographic peak height ratio or peak area ratio based on UV absorbency at 251 nm was used for quantitative analysis. The assay procedures were simple and the assay was specific and had adequate precision and accuracy. Calibration standards with concentrations over the range of 0.01 20 microg/ml were validated for routine sample analysis to support the pharmacokinetic and toxicology studies with linezolid in dog, rat, mouse, and rabbit. Analysis of quality control samples showed the coefficients of variation were usually <10% and the measured and theoretical concentrations differed by <10% in most assays. Linezolid in the plasma samples was stable when stored at below -20 degrees C for at least 63 days, at room temperature (22-23 degrees C) for up to 24 h, and after three freeze-thaw cycles. This HPLC method has been successfully used in multiple laboratories to assay plasma samples from pharmacokinetic and toxicology studies with linezolid in the animal species.

Acetamides↗

Cultured hepatocytes as investigational models for hepatic toxicity: practical applications in drug discovery and development.

Drugs can fail at any phase during discovery, preclinical or clinical development due to unacceptable levels of toxicity, and liver is commonly the principle target organ. Investigational toxicology methods, using appropriate models and hypotheses, can often resolve problems, identify toxic chemical substituents and salvage therapeutic discovery programs. While in vivo models are used to investigate hepatic drug effects in the context of toxicokinetics and systemic influences, cell culture models provide in vitro systems for investigating specific mechanisms in a precisely controlled environment. Using primary hepatocytes isolated from laboratory animals, we have explored several drug-induced hepatic disorders that surfaced during different phases of drug discovery and development. Additionally, the use of human hepatocytes has allowed us to address concerns for human exposure, examine human relevance of animal data, and provide perspective on problems encountered in clinical trials.

Animals↗

Analysis of drugs and other toxic substances in biological samples for pharmacokinetic studies.

The importance of the role of analysis of drugs and other toxic substances in biological samples (bioanalysis) in medicine, toxicology, pharmacology, forensic science, environmental research and other biomedical disciplines is self-evident. Among these disciplines, bioanalysis plays a special pivotal role in pharmacokinetics. The pharmacokinetic parameters, such as half-life, volume of distribution, clearance and bioavailability, of drugs and other compounds are derived from the concentrations of these analytes assayed in the biological samples collected at specified time points. The capability of analysts to develop sensitive and specific analytical methods for the assay of low concentrations of drugs and other toxic compounds in small amounts of biological samples has contributed significantly to the theoretical advances in pharmacokinetics and its applications in clinical pharmacology and the management of drug therapy in patients. The increased demands for pharmacokinetic applications in turn have stimulated the innovation and improvement in bioanalytical technologies. The reliability of the pharmacokinetic conclusions depends on the accuracy and precision of the analytical methods employed to assay the biological samples. Factors that affect the integrity of the bioanalytical data should therefore be controlled in analysis of biological samples for pharmacokinetics studies. The biological samples for drug concentration determination should be collected as specified in the study protocol with respect to the time and site of sampling. These samples should be processed to avoid extraneous interactions between the analytes and sampling devices or additives resulting in the redistribution of the analytes between components of the biological samples, such as displacement of drug binding and changes in the distribution of the analytes between plasma and red blood cells. The stability of the drugs and other analytes in the samples should also be evaluated to establish the conditions suitable for the transportation and storage of the samples to avoid chemical, photochemical and enzymatic degradation of the analytes. Various technologies have been utilized to assay biological samples for pharmacokinetic studies. The most frequently used are chromatography (high-performance liquid chromatography, gas chromatography and thin-layer chromatography), immunoassays and mass spectrometry.(ABSTRACT TRUNCATED AT 400 WORDS)

Body Fluids↗

Quantitative liquid chromatographic determination of bromadoline and its N-demethylated metabolites in blood, plasma, serum, and urine samples.

Bromadoline and its two N-demethylated metabolites were extracted into ether:butyl chloride after the addition of internal standard and basification of the various biological fluids (blood, plasma, serum, and urine). These compounds were then extracted into dilute phosphoric acid from the organic phase and separated on a reversed-phase chromatographic system using a mobile phase containing acetonitrile and a buffer of 1,4-dimethylpiperazine and perchloric acid. The overall absolute extraction recoveries of these compounds were approximately 50-80%. The background interferences from the biological fluids were negligible and allowed quantitative determination of bromadoline and the metabolites at levels as low as 2-5 ng/mL. At mobile phase flow rate of 1 mL/min, the sample components and the internal standard were eluted at the retention times within approximately 7-12 min. The drug- and metabolite-to-internal standard peak height ratios showed excellent linear relationships with their corresponding concentrations. The analytical method showed satisfactory within- and between-run assay precision and accuracy, and has been utilized in the simultaneous determination of bromadoline and its two N-demethylated metabolites in biological fluids collected from humans and from dogs after administration of bromadoline maleate.

Benzamides↗

Assay of adinazolam in plasma by liquid chromatography.

A procedure for the quantitative determination of adinazolam in plasma was developed. The drug, an N-demethylated metabolite, and an internal standard were extracted from basified plasma into ethyl acetate. After evaporation, the residue was dissolved in toluene which was washed with sodium hydroxide. The toluene was evaporated and the residue was dissolved in a mixture of acetonitrile, methanol, and water for chromatography. The concentrations of the drug and the metabolite were determined using reverse-phase liquid chromatography with UV detection at 254 nm. The assay methodology showed good peak height ratio-concentration linearity, precision, and accuracy and has been used to analyze plasma samples collected from human subjects after oral administration of adinazolam mesylate in compressed tablets. The low plasma background interferences allowed the quantitative determination of concentrations as low as approximately 5 ng/mL.

Anti-Anxiety Agents↗

Chlorpheniramine. I. Rapid quantitative analysis of chlorpheniramine in plasma, saliva and urine by high-performance liquid chromatography.

A method was developed for the rapid quantitative analysis of chlorpheniramine in plasma, saliva and urine using high-performance liquid chromatography. A diethyl ether or hexane extract of the alkalinized biological samples was extracted with dilute acid which was chromatographed on a reversed-phase column using mixtures of acetonitrile and ammonium phosphate buffer as the mobile phase. Ultraviolet absorption at 254 nm was monitored for the detection and brompheniramine was employed as the internal standard for the quantitation. The effects of buffer, pH, and acetonitrile concentration in the mobile phase on the chromatographic separation were investigated. A mobile phase 20% acetonitrile in 0.0075 M phosphate buffer at a flow-rate of 2 ml/min was used for the assays of plasma and saliva samples. A similar mobile phase was used for urine samples. The drug and internal standard were eluted at retention volumes of less than 17 ml. The method can also be used to quantify two metabolites, didesmethyl- and desmethylchlorpheniramine, in the urine. The method can accurately measure chlorpheniramine levels down to 2 ng/ml in plasma or saliva using 1 ml of sample, and should be adequate for biopharmaceutical and pharmacokinetic studies. Various precautions for using the assay are discussed.

Chlorpheniramine↗

Simple, rapid and micro high-pressure liquid chromatographic method for the simultaneous determination of tolbutamide and carboxy tolbutamide in plasma.

A rapid high-pressure liquid chromatographic (HPLC) assay is described for the quantitative analysis of tolbutamide and its major metabolite, carboxy tolbutamide in plasma. An aliquot (25--100 microliter) of plasma was prepared for chromatography by deproteinization as follows. One volume of plasma and 2.5 volumes of acetonitrile were vortex mixed for a few seconds and then centrifuged for approx. 1 min. A 50-microliter sample of the clear supernatant was injected into the chromatograph. A mu Bondapak C18 reversed-phase column was used with a mobile phase acetonitrile--0.05% phosphoric acid (45:55) at a flow-rate of 1.5 ml/min. The column effluent was monitored by a variable-wavelength UV detector set at 200 nm. Tolbutamide and its metabolite had retention times of 5.75 and 3.25 min, respectively. The procedure yuelds reproducible results with sensitivity adequate for routine clinical monitoring of plasma levels or for single-dose pharmacokinetic studies. A number of commonly used drugs do not interfere with the method. A single plasma sample can be analyzed in approx. 9 or 10 min.

Animals↗

High-pressure liquid chromatographic method for the simultaneous quantitative analysis of propranolol and 4-hydroxypropranolol in plasma.

A simple and rapid high-pressure liquid chromatographic procedure is reported for the simultaneous quantitative determination of propranolol and 4-hydroxypropranolol in plasma. Following an extraction the samples are chromatographed on a reversed-phase column and the components in the column effluent are detected by fluorescence monitoring. Using 1-ml plasma samples propranolol and 4-hydroxypropranolol concentrations at least as low as 1 ng/ml and 5 ng/ml, respectively, can be quantitated. The reproducibility of the method is satisfactory and no interference from endogenous plasma components or other drugs has been observed. A single plasma sample can be analyzed in approximately 20 min.

Chromatography, High Pressure Liquid↗

Simple, rapid and micro high-pressure liquid chromatographic determination of endogenous "true" creatinine in plasma, serum, and urine.

Previously published methods for endogenous creatinine levels in plasma, serum, or urine lack specificity or are subject to interferences from endogenous or exogenous substances. The developed simple, rapid, and specific high-pressure liquid chromatographic method includes the novel deproteinization and extraction of 1 volume of plasma or serum with 2.5 volumes of acetonitrile and also of 1 volume of urine with 40 volumes of a 20% water-80% acetonitrile solution. An aliquot of the supernate is then injected directly into the chromatograph. A cation-exchange column and acidified (0.02% of 85% phosphoric acid) 0.1 M ammonium phosphate solution as the mobile phase, with a flow rate of 2 ml/min, were used. Creatinine, with a retention time of 3.8 min, was monitored via its UV absorption at 215 nm. Both peak heigh and integrated area methods of quantitation yielded the same results. Several methods were employed to show that the "suspected" creatinine peak from plasma samples was due entirely to the "true" creatinine. No interference was found in samples obtained from normal and renal patients. The day-to-day variation in the detector response was small. Each assay requires only about 5 min for completion. Ten microliters of plasma or serum or 1 microliter of urine is sufficient for analysis.

Adult↗

Simple and rapid high-pressure liquid chromatographic simultaneous determination of aspirin, salicylic acid, and salicyluric acid in plasma.

A rapid and sensitive high-pressure liquid chromatographic assay was developed for aspirin, salicylic acid, and salicyluric acid in plasma. The procedure involves the solvent extraction of these compounds from plasma and separation using a reversed-phase column eluted by acidified aqueous acetonitrile. Small quantitites of aspirin can be assayed directly in the presence of a large quantity of salicylic acid. The assay is also free from blank interference.

Aspirin↗

Simple, rapid, and micro high-pressure liquid chromatographic determination of plasma griseofulvin levels.

A rapid high-pressure liquid chromatographic assay is described for the quantitative determination of griseofulvin in plasma. An aliquot (25--10 microliter) of plasma was deproteinized by a simple procedure involving the addition of 2.5 volumes of acetonitrile, vortex mixing for a few seconds, and centrifugation for 1 min. The clear supernate, 50 microliter, was injected into the high-pressure liquid chromatograph. A reversed-phase column was used with a mobile phase of distilled water-acetonitrile (1:1) at a flow rate of 2 ml/min and was operated at ambient temperature. A fluorescent detector with an excitation wavelength of 260 nm was employed to monitor the column effluent. Griseofulvin had a retention time of 3.8 min. This procedure yields reproducible results with high sensitivity; plasma concentrations as low as 50 ng/ml can be measured. Several commonly used drugs do not interfere. Analysis of plasma samples collected from a rabbit injected with griseofulvin indicated that the procedure is suitable for pharmacokinetic studies and clinical monitoring of plasma concentrations in patients. Assay turnaround time is less than 6 min. For clinical monitoring of plasma griseofulvin concentrations, a sample volume as small as 10 microliter can be used.

Animals↗

Rapid and micro high-pressure liquid chromatographic method for simultaneous determination of procainamide and N-acetylprocainamide in plasma.

A rapid and simple high-pressure liquid chromatographic method was developed for the simultaneous determination of plasma levels of procainamide and its major metabolite, N-acetonitrile, and the supernate was chromatographed on a cation-exchange column. The assay can be carried out on as little as 20 microliter of plasma and requires only about 7 min for each sample. No interference was found in plasma samples from cardiac patients receiving procainamide. This method is simple, fast, and useful for routine therapeutic monitoring and for pharmacokinetic studies procainamide and its metabolite.

Acetylation↗