PubMed Health⌕ Search

Biomedical subjects

G W Reeves

Publications and source records attributed to G W Reeves.

17 recordsLinked to original sources

Guided tissue healing for single-tooth implants.

The emergence profile of a single-tooth implant abutment has a significant effect on the esthetics of the final restoration. Most healing abutments are cylindrical, unlike the nonround contours of the natural teeth being replaced. The resulting peri-implant sulcus is round rather than having the correct anatomic cross-sectional shape. This disparity may compromise the ideal emergence profile of the final restoration. This article presents a technique in which a custom abutment and provisional crown or the definitive restoration can be placed at second-stage surgery to guide tissue healing to optimum form and esthetics.

Alveolar Ridge Augmentation↗

Microleakage of a new dental adhesive comparing microfilled and hybrid resin composites.

The objective of this study was to evaluate the in vitro microleakage of a new adhesive system, Syntac. Class V preparations were cut at the cementoenamel junction in 20 extracted bovine incisors and 20 extracted human incisors. One group of 10 human and 10 bovine teeth was restored with Syntac and a microfilled posterior resin composite; the other group was restored with Syntac and a hybrid resin composite. Microleakage was evaluated at 1 week with a 45Ca radioisotope method. No statistically significant differences between human and bovine substrates were found with either resin composite. The Syntac/hybrid resin restorations leaked less than did the Syntac/microfilled resin restorations at the gingival (dentin) margin in the bovine teeth; however, this difference was not statistically significant.

Acrylates↗

Adding retentive features in the rebonding of cast metal resin-bonded prostheses.

Many methods have been used to improve retention in resin-retained fixed prostheses, such as electrolytic etching of the retainer, the labial wrap design, proximal grooves, cast pin retention, and the use of improved adhesive resins such as Panavia EX (Kuraray Co, Osaka, Japan). Insufficient retentive features often lead to debonding of resin-retained fixed prostheses. Debonded prostheses may occasionally be recemented and successfully retained by the addition of retentive features to the prosthesis and abutment teeth. When recementing a debonded prosthesis with questionable retention, additional retention may be added to the retentive wings of the prosthesis by using a Rochette retentive hole in combination with pin retention or enamel/dentinal slots in the abutment teeth.

Dental Pins↗

Technique to diminish discomfort from the palatal injection.

A new technique for diminishing the discomfort of a palatal injection has been described. The technique utilizes a cotton pellet saturated with dichlorodifluoromethane spray held in contact with the tissue 5 seconds to freeze a small portion of the surface tissue. The injection needle then penetrates the frozen tissue with little discomfort to the patient.

Administration, Topical↗

Microleakage of Gluma Bond, Scotchbond 2 and a glass ionomer/composite sandwich technique.

Bonding to dentin with long-term success has been a quest of dentistry for some time. Microleakage is a major problem that can lead to staining and discolorization of the restoration and postoperative sensitivity. Some of the newer dentin bonding systems include Gluma Bond and Scotchbond 2. A glass ionomer/composite "sandwich" technique has also been advocated for dentin bonding. Here a glass ionomer is first bonded to the dentin, bonding agent is applied to the glass ionomer and a composite restoration is then placed into the cavity preparation. The purpose of this study was to compare the microleakage of Gluma Bond, Scotchbond 2, the glass ionomer/composite sandwich technique along with a positive and negative control. This was accomplished, in vitro, using extracted human teeth and a Ca45 radioisotope technique. The teeth were examined for microleakage at periods of 1 week, 6 months and 12 months. The results of this study indicate that, in vitro, the glass ionomer sandwich technique does not stop microleakage. The results also indicate that, in vitro, Gluma Bond and especially Scotchbond 2 restorations can resist microleakage for short periods of time. However, at the end of the 12 months, all Gluma Bond and Scotchbond 2 specimens exhibited gross microleakage.

Adhesives↗

Microleakage of two new dentinal bonding systems.

Class V abrasion and erosion lesions restored with composite resin seem to be more susceptible to microleakage, because the gingival margin is usually placed in cementum and/or dentin. The purpose of this study was to evaluate the microleakage, in vitro, of two new dentinal bonding systems along with a positive and negative control. This study was accomplished using extracted human teeth and a calcium-45 radioisotope technique. The teeth were examined for microleakage at periods of 1 week, 6 months, and 1 year. The results at all time intervals indicated that the cavities restored with the new bonding agents and their respective composite resins leaked more than did the negative control, glass-ionomer cement.

Composite Resins↗

The reduction of phenytoin-induced gingival overgrowth in a severely disabled patient: a case report.

Gingival overgrowth frequently occurs in patients medicated with phenytoin (5,5-diphenylhydantoin) to control epileptic seizures. In a recent study, gingival overgrowth was observed in a patient in an experimental group evaluating an automatic toothbrushing system for severely disabled patients. During the evaluation period, which included an oral hygiene regimen provided by an attendant or housemate and a regimen with the Mississippi Dental Care System (MDCS), the patient's gingival overgrowth was noticeably reduced. The results of this study indicate that control of local factors with the MDCS is significantly better than the routine home care regimen, and that the phenytoin-associated gingival overgrowth in this patient was reduced by MDCS.

Adult↗

Oral hygiene for the severely handicapped: clinical evaluation of the University of Mississippi dental care system.

The study reported here was a clinical evaluation of an automatic toothbrushing device for persons with severe handicapping conditions. This device, the University of Mississippi dental care system, is designed for patients who are unable to control their arms and hands. The effectiveness of this device was compared to routine (ordinary, manual) regimens of oral hygiene through use of gingival (Loe-Silness) and plaque (Turesky) indexes (GIs, PIs). Plaque indexes for patients under routine care averaged 2.11; PIs for patients under the dental care system averaged 1.47. Based on Ebbutt's extra period changeover design model, the t-test for difference in plaque scores is significant (P less than .001). The results indicate that the University of Mississippi dental care system improves the patients' ability to independently control plaque.

Persons with Disabilities↗

Comparison of marginal adaptation between direct and indirect composites.

The evaluation of composite resin as a posterior restorative material has been slow and attended by several problems. Gap formation has been considered a serious problem by many researchers. The purpose of this in vitro study is to compare the marginal adaptation of posterior composite resins placed by a direct method with those placed by an indirect method utilizing flexible dyes. Conclusions drawn from the results of this study are that both techniques produced marginal gaps. Also there were no differences in the width of marginal gaps in the composite resin restorations placed by our direct or indirect methods, and no marginal gap differences were observed as a result of anatomical location.

Analysis of Variance↗

Microleakage of a new cavity varnish with a high-copper spherical amalgam alloy.

In a study in vitro Copalite and Barrier cavity varnishes were applied to the walls of class 1 prepared cavities before placing Tytin, a high-copper amalgam. Tests with 45Ca and autoradiographs showed that at six months only Copalite was effective in preventing microleakage. At one year neither Barrier nor Copalite was preventing leakage.

Copper↗

Microleakage of new dentin bonding systems using human and bovine teeth.

The objective of this study was twofold: to evaluate the microleakage behavior of three dentin bonding systems and to determine if bovine teeth are comparable substrates to human teeth when studying the microleakage of various materials. The materials evaluated were Scotchbond Multi-Purpose Adhesive, Prisma Universal Bond 3, and All-Bond 2. All three bonding systems were used in combination with Prisma APH hybrid composite for comparison of microleakage behavior. Sixty class 5 preparations were cut at the cementoenamel junction for groups containing 30 human and 30 bovine teeth. A 1 mm 45 degree bevel was placed at the enamel margin. Teeth were grouped according to the dentin bonding system used and then restored according to the manufacturer's directions. After restoration, the teeth from each group were stored in distilled water at 37 degrees C for 3 days. The teeth were then thermocycled between 4 degrees C and 58 degrees C for 100 cycles and returned to distilled water at 37 degrees C for an additional 4 days. The teeth were then sealed with nail polish up to 1 mm from the margins of the restoration and placed in 45Ca isotope for 2 hours. The teeth were then sectioned and placed on x-ray film to produce autoradiographs. Microleakage was evaluated for the enamel and dentin margins separately using the following scale: 0 = no leakage, 1 = penetration of isotope to less than 1/2 the distance to the axial wall, 2 = penetration of isotope greater than 1/2 of the distance to the axial wall but short of the axial wall, and 3 = penetration of isotope to the axial wall or beyond. The materials were compared to each other using the Mann-Whitney U and Kruskal-Wallis tests. The gingival margins were compared to the incisal margins for all materials. No statistically significant differences in microleakage were revealed between the incisal and gingival location for human substrates, but there was statistically significant greater gingival microleakage for bovine substrates. All-Bond 2 leaked significantly more than Scotchbond Multi-Purpose for human substrates at the incisal margin. All-Bond 2 had significantly more microleakage than Prisma Universal Bond 3 at both dentin and enamel margins for the bovine substrate. There were no statistically significant differences in microleakage among the bonding systems for the human substrate. No statistically significant differences between the microleakage behavior of human and bovine substrates were found. These results support the use of bovine teeth for in vitro microleakage studies.

Animals↗