Virtual simulation: initial clinical results.

We have developed a graphics-based three-dimensional treatment design system that permits the physician to easily understand which anatomy will be treated for any arbitrary beam orientation. Our implementation of this system differs from others in that the software (the Virtual Simulator) simulates the full functionality of a (physical) radiation therapy simulator allowing it to be easily used by physicians. The details of the of our initial clinical experience with virtual simulation are presented in this paper. Virtual simulation was attempted in 71 patients and completed in 65. In 41/71 patients (58%), the beam orientations chosen differed significantly from those traditionally used in our department. Although virtual simulation lead to traditional radiation portals in the remaining patients, in 23/71 (32%) secondary blocking was designed which was different from that which would have been conventionally employed. Thus, overall, virtual simulation lead to treatment changes in 64/71 (90%) of the patients in whom it was attempted. In 78% of evaluable patients the treatment designed with virtual simulation could be implemented on the physical simulator with a precision of +/- 5 mm (+/- 3 mm for brain and head and neck). Thus virtual simulation allowed both accurate planning and execution of treatment plans that would be difficult to achieve with conventional methods.

Brain Neoplasms

A comparison of postoperative techniques for carcinomas of the larynx and hypopharynx using 3-D dose distributions.

If a head and neck cancer originates low in the neck with a primary site below the shoulders, a technical challenge to the radiation oncologist exists in that the entire neck needs treatment while avoiding overlap of multiple fields on the spinal cord. No standard solution to this problem exists. We have developed a 3-D treatment planning tool that can be used to develop and compare 3-D treatment plans and dose distributions. Using this tool, we have studied the following techniques for the postoperative treatment of carcinomas of the larynx and hypopharynx, tumors that often embody the problems discussed above: (a) the mini-mantle technique used at the Massachussetts General Hospital, (b) a 3-field technique used at the University of Florida at Gainesville (UF 3-field), (c) a 3-field technique used at our institution and at many others (standard 3-field), and (d) the kicked out lateral technique used at our institution and at others. The 3-D dose distributions from these plans are compared. With 100% delivered just anterior to the vertebral body at mid-neck, the mini-mantle technique results in large 120% hot spots laterally and anteriorly in the neck. Near the mastoid tips, however, the dose falls to 100%. The upper neck nodes may be underdosed since this is 20% cooler than the lateral-anterior neck dose (where a large 120% hot spot exists). The spinal cord is adequately blocked. The two 3-field techniques result in small hot spots at the junction of the lateral and anterior fields. Because different methods are used to prevent overlap at the spinal cord, these hot spots occur anteriorly in the standard 3-field technique and laterally in the UF 3-field technique. The spinal cord block results in untreated neck tissue which can be supplemented with electrons in the standard 3-field technique, but is left untreated in the UF 3-field technique. Both techniques result in a generous length of spinal cord which does not receive full dose. The kicked out lateral technique treats the entire neck and reconstructed pharynx without matching fields at midneck. The upper mid mediastinum is underdosed 10-20% despite being within the posterior inferior portion of the beam. This could be minimized by using a tissue compensator. Unless there is significant subglottic extension or significant risk of disease in the upper mediastinum, we favor treating these malignancies with the kicked out lateral technique, which avoids the problem of junctioning lateral and anterior fields and provides a fairly homogeneous dose distribution.

Combined Modality Therapy

The portable virtual simulator.

The Virtual Simulator is a software tool for support and management of the geometric component of 3-dimensional radiotherapy treatment design. The Virtual Simulator is a software implementation of a physical simulator with additional functionality not currently available on physical simulators. Treatment of a virtual patient, derived from CT or other source, is simulated using the Virtual Simulator in the same way a physical simulator would be used. The intent of this approach is to provide the user with a familiar working environment for radiotherapy treatment design. Key features include an effective and efficient user interface, and the use of computing techniques and software standards which enhance portability to a variety of computer workstations. The Virtual Simulator is implemented in the C programming language using the X Window System, and has been written with the generic UNIX workstation in mind. It has been demonstrated that it can be installed and run without modification on workstations from a number of vendors.

Computer Simulation

Recent advances in radiotherapy treatment planning.

Radiation treatment planning is currently in a state of rapid change. Dissatisfaction with past planning technology stems from the growing realization that: (1) Increases in the local regional tumor control rate will increase the cure rate in many malignancies. (2) Even at the best treatment centers geometric tumor misses are commonplace. (3) Traditional constraints on treatment techniques, originally imposed for simplicity and reproducibility, are no longer necessary, and can result in suboptimal treatment. (4) Treatment plans judged "optimal" in two dimensions may be far from optimal when viewed over the entire treatment volume. (5) Lack of treatment reproducibility is also commonplace, and can be demonstrated to adversely affect treatment outcome. On the positive side, recent developments in computer graphics, image processing, radiation physics, and radiation biology are now making it possible to define, design, and deliver sophisticated 3D radiation treatments. However, because many of these technologies are being developed for other disciplines, their applicability to radiation therapy treatment planning is not widely appreciated. We outline the current status and new developments in radiation therapy treatment planning.

Artificial Intelligence

Virtual simulation in the clinical setting: some practical considerations.

Virtual simulation departs from normal practice by replacing conventional treatment simulation with 3-dimensional image data and computer software. Implementation of virtual simulation requires the ability to transfer the planned treatment geometry from the computer to the treatment room in a way which is accurate, reproducible, and efficient enough for routine use. We have separated this process into: (a) immobilization of the patient; (b) establishment and alignment of a practical coordinate system for the patient/couch system; and (c) setup of the patient/couch been addressed by the use of hemi- or full-body foam casts, the second by use of an alignment jig on the treatment couch, and the third with the aid of a patient coordinate system referenced to easily located landmarks. Phantom studies and clinical practice have shown these techniques to be practical and effective within reasonable clinical bounds.

Computer Simulation

Computation of digitally reconstructed radiographs for use in radiotherapy treatment design.

The increasing use of 3-dimensional radiotherapy treatment design has created greater reliance on methods for computing images from CT data which correspond to the conventional simulation film. These images, known as computed or digitally reconstructed radiographs, serve as reference images for verification of computer-designed treatments. Used with software that registers graphic overlays of target and anatomic structures, digitally reconstructed radiographs are also valuable tools for designing portal shape. We have developed radiograph reconstruction software that takes full advantage of the contrast and spatial detail inherent in the original CT data. This goal has been achieved by using a ray casting algorithm which explicitly takes into account every intersected voxel, and a heuristic approach for approximating the images that would result from purely photoelectric or Compton interactions. The software also offers utilities to superimpose outlines of anatomic structures, field edges, beam crosshairs, and linear scales on digitally reconstructed radiographs. The pixel size of the computed image can be controlled, and several methods of interslice interpolation are offered. The software is written in modular format in the C language, and can stand alone or interface with other treatment planning software.

Humans

Three-dimensional display techniques in radiation therapy treatment planning.

Good radiation treatment planning requires that the target volume be treated with a high and uniform dose of radiation while irradiating normal tissue as little as possible. Even if the merits of a given treatment plan are judged only on the appearance of isodose lines in one or a few planes it can sometimes be difficult for the experienced radiation oncologist to select the best of several alternative plans. If consideration is given to the entire spatial distribution of dose, however, the problem becomes far more difficult because of the enormous amount of data that must be evaluated. We believe that the lack of suitable methods to display these data has greatly contributed to the slow incorporation of 3D considerations into routine radiation treatment planning. In the past few years there have been great advances in both the theory of how to produce effective 3D displays and in the display hardware itself. In this paper we survey some of the methods used at the University of North Carolina, and show specific examples of how these displays can be used in radiation therapy treatment planning.

Computer Graphics

A spreadsheet program for brachytherapy planning.

A computer program (brachy-spread) which allows spreadsheet-like interactive adjustment of the loading of any brachytherapy application has been implemented. Sources are collected into objects, each assigned an activity and duration of implant. Activities and times may be adjusted by moving a cursor to the datum to be edited and entering a new value from the keyboard. Alternatively, the desired total dose to a given calculation point may be edited resulting in a recalculation of the time for all objects. For each of a set of calculation points, dose rates, total doses, and the percent contribution of each object to the point are displayed and instantly updated as the times and activities are adjusted. The program design includes rapidly updated display of isodose curves in previously selected arbitrary planes. A strategy for providing rapid dose display involving precalculation of fractional dose tables is used. The program has significantly reduced the time required to determine the appropriate loading of GYN applications and of implants which involve a combination of line sources and seeds.

Algorithms

Automatic digital contrast enhancement of radiotherapy films.

The practice of radiotherapy involves the precise geometric localization of both anatomic and non-anatomic structures using radiographs which are typically of very low contrast. Portal and verification films suffer from poor contrast as a result of the dominance of Compton interactions at therapeutic energies, and implant localization films often are degraded by extreme patient thickness (lateral pelvis) or projection of bony structures (head and neck). Automatic contrast enhancement techniques developed and proven for optimization of the display of digitally produced images such as CT have been applied to radiotherapy films to improve contrast and augment readability. This approach has become viable only recently with the advent of high speed, high resolution film digitizers and laser cameras and the evolution of sufficiently powerful computer hardware.

Brachytherapy

Coordinate transformation as a primary representation of radiotherapy beam geometry.

An approach to both geometric specification of radiotherapy beams and computerized solution of geometric treatment planning problems using coordinate transformations is presented. It is demonstrated that the specification of the geometric relationship of a treatment beam to a patient can be uniquely given by a 4 x 4 coordinate transformation matrix, and that the matrix representation can be translated from (and to) the more conventional machine-based specification of geometry. This approach enables a compact representation of the patient/beam geometry which is independent of the specific labeling conventions of the treatment machine and which can be directly exploited in the solution of treatment planning problems. Beam geometry can be easily described either in terms of the natural degrees of freedom of a therapy machine or in terms of alternative, problem-specific frames of reference. The ability to use these various frames of reference interchangeably allows the designer of treatment design software to present appropriate task-specific user interfaces for arbitrarily complex tasks, and thus reduce the cognitive burden on users of the software.

Humans