[Quality assurance with teleradiology].

Teleradiology offers many applications for quality assurance in medicine. The spectrum reaches from electronic consultations in emergency or special cases and double reading--along with new models of cooperative work and medical networks--to technical quality assurance and integration into interinstitutional and patient controlled health records. Regional teleradiology networks based on server concepts can fulfill the developing technical and organisational requirements. The increasing mobility arising from smaller radiological equipment and improved accessibility to experts with minimized visualisation and reporting systems will change the radiological world of tomorrow, especially in combination with the usage of knowledge based systems in reference data bases and computer assisted diagnosis (CAD). Teleradiology by itself must be liable to quality assurance measurements to prevent unnecessary radiation exposure or danger to the doctor patient relation.

Computer Communication Networks↗

[The future of teleradiology: results of Teleradiology Expert Meeting of the Health Network Congress 2001].

Legal prerequisites have substantial influence on the development of teleradiology. At an expert meeting (Mannheim, 8.6.2001) a proposal for a teleradiology article in the new German x-ray ordinance has been set up. An exception of the demand for a doctor trained in radiation protection at the point of examination shall be established for emergency cases. To realize the intended improvement of patient care measurements for quality assurance concerning the medical personnel and processes are necessary. Along with other current developments the basis of secure regional teleradiology networks is now built up.

Forecasting↗

[New concepts in teleradiology with Dicom e-mail].

UNLABELLED: The recently published Dicom supplement 54 (dicom e-mail) defines a connection between the internet and the medical communication inside hospitals. Up to now vendor specific dicom protocol additions were needed to realize certain teleradiology solutions. The new concept relies on vendor independent standard protocols without specific additions. MAIN FEATURES: client-server solution using the internet designed for emergency medicine integration of various clinical informations approved security concept modularized architecture The concept was realized within the scope of a teleradiology project of the state of Rheinland-Pfalz, Germany. It will be expanded to the state of Baden-Wuerttemberg. Germany in 2002 with over 20 hospitals included.

Computer Systems↗

Teleradiology requirements and aims in Germany and Europe: status at the beginning of 2000.

Specific radiological requirements have to be considered for realization of telemedicine. In this article the goals and requirements for an extensive implementation of teleradiology are defined from the radiological user's point of view. Necessary medical, legal and professional prerequisites for teleradiology are presented. Superior requirements, such as data security and privacy or standardization of communication, must be realized. Application specific requirements, e. g. quality and extent of teleradiological functions as well as technological alternatives, are discussed. Each project must be carefully planned in relation to one's own needs, extent of functions and system selection. Topics like legal acceptance of electronic documentation, reimbursement of teleradiology and liability must be clarified in the future.

Europe↗

First results of computerised tomographic angiography using electron beam tomography.

The aim of this study was to evaluate the suitability of electron beam tomography (EBT) with fast continuous volume scanning for CT angiography (CTA) in chest and abdomen. An Evolution XP EBT scanner with a new software version (12.34) was used. One hundred forty images per study can be acquired in 17 s using 3-mm collimation and overlapping image reconstruction. Study protocols for five different clinical applications of EBT CTA were established and evaluated. The EBT CTA technique was performed in 155 patients. High- and homogeneous density values were achieved along the whole course of the vessels; the mean density in the aorta was > 240 HU. Coeliac axis, superior and inferior mesenteric artery, renal and lumbar arteries were visualised in all cases. Maximum intensity projection and shaded surface display reconstruction demonstrated the relation between aneurysm and aortic branches very well due to an excellent resolution along the z-axis. In large scan volumes overlapping image reconstruction demonstrated better resolution along the z-axis than is available with helical CT. The EBT CTA technique proved to be very well suited excellent suitability for evaluation of pulmonary vessels. Compared with helical CT, EBT CTA offers a shorter scan time, which allows higher contrast enhancement in pulmonary vessels. The identification of intraluminal emboli and mural thrombi has improved. The EBT CTA technique is a very reliable tool for evaluation of aortic disease and pulmonary vessels.

Angiography↗

[The role of electron beam CT in the diagnosis of acute pulmonary embolism--presenting a new examination protocol].

PURPOSE: To evaluate electron beam tomography in the detection of acute pulmonary embolism using a new acquisition protocol. MATERIALS AND METHODS: 65 patients underwent electron beam tomography (EBT) and v./p. scintigraphy. According to the inclusion criteria 46 patients participated in the study. Contrast enhancement and detectability of pulmonary arteries were scored on a 4 step scale for image quality. The results of prospective detection of pulmonary embolism were compared for both modalities (blinded reading). "Embolism", "questionable embolism" and "no embolism" were used as categories. RESULTS: 22/46 patients (48%) showed acute pulmonary embolism. EBT and scintigraphy were discordant in 24% of patients. In EBT 1 false positive and 1 false negative case occurred, scintigraphy demonstrated 2 false negative and 3 false positive cases. 6/9 patients with questionable findings in scintigraphy were correctly classified by EBT to a category "embolism" or "no embolism" as "suspected embolism", EBT displayed a sensitivity of 96.3% and a specificity of 94.7%. Scintigraphy evidenced a sensitivity of 93.7% and a specificity of 84.4%. CONCLUSIONS: EBT shows better results than scintigraphy for the detection of acute pulmonary emboli. The evaluated new acquisition protocol for EBT seems to be well suited. High vessel contrast and thin slices allow a reliable detection of segmental and subsegmental pulmonary arteries.

Acute Disease↗

Dose and image quality of electron-beam CT compared with spiral CT.

RATIONALE AND OBJECTIVES: To examine dose and image quality of electron-beam CT (EBCT) with continuous volume scan versus spiral CT. METHODS: An EBCT scanner was compared with a spiral CT (SCT) scanner. Three phantoms were used to measure low-contrast resolution, high-contrast resolution, slice width, and dose. RESULTS: The EBCT scans showed 30% lower high-contrast resolution for most settings. The dose was comparable to that of spiral CT with 3 mm collimation and 76%/106% higher with EBCT for 1.5 mm/6 mm collimation. Low-contrast resolution was comparable to that of spiral CT using 3 mm collimation, slightly worse for 1.5 mm, and bad for 6 mm EBCT collimation (four times higher dose to reach comparable contrast-to-noise ratio). CONCLUSIONS: Significant restrictions were found using EBCT with continuous volume scan. The authors found that 3 mm collimation can yield acceptable high-contrast resolution and good low-contrast resolution compared with spiral CT. The use of 6 mm or 1.5 mm collimation needs to be restricted to selected cases.

Evaluation Studies as Topic↗

[Performance of electron-beam CT: continuous-volume-scan compared to spiral CT].

To compare patient dose and image quality of electron-beam-CT vs. spiral-CT by means of phantom measurements. An EBCT scanner (C-150 XP) and a spiral-CT scanner (GE HiSpeed Advantage) were used to scan three different phantoms. Administered dose, high contrast (HC) resolution, low contrast (LC) lesion detectability and the width of the radiation beams were measured. EBCT showed 25-35% lower HC resolution in comparison to spiral-CT. LC lesion detectability showed equivalent results for S/N vs. patient dose using 3 mm collimation with EBCT and spiral-CT, whereas spiral-CT was superior for 1.5 and 6 mm collimation. Dose measurements revealed a 2 fold higher patient dose using EBCT with 1.5 mm or 6 mm collimation compared to spiral-CT using equivalent scan parameters. No differences were seen using 3 mm collimation. Differences were due to insufficient beamside collimation of the EBCT. The use of EBCT with 6 mm collimation should be avoided, because of impaired performance. Using 3 mm collimation, EBCT showed comparable performance like state of the art spiral-CT despite lower HC resolution.

Algorithms↗

[Electron-beam CT-angiography in abdominal aortic aneurysms. Initial results].

PURPOSE: To evaluate the suitability of ultrafast electron-beam tomography (EBT) for the investigation of abdominal aortic aneurysms using CTA. METHODS: Thirty-one patients with suspected abdominal aortic aneurysm were investigated with EBT using an Evolution XP scanner (Siemens, Erlangen) with the newest software version 12.34 with continuous volume scanning of 140 images in 17 s. Collimation was 3 mm, table increment 4 mm with overlapping image reconstruction every 2 mm, exposure time 200 ms (124 mAs), resulting in a scan-range of 28 cm. A quantity of 80 ml contrast material was administered (flow 4 ml/s). Visualization of the abdominal aorta and its branches was performed with MIPs and shaded surface display. Evaluation of image quality was based on a four-step classification scale (1 = good, 4 = insufficient) for the demonstration of the abdominal aorta and the visceral, renal and iliac arteries. RESULTS: All EBT examinations demonstrated high and homogeneous density values along the whole vessel course with a mean density value of 258.7 +/- 47.3 HU for the abdominal aorta and the iliac arteries. Quality evaluation for the vessel demonstration showed mean values between 1.22 and 1.57 for the abdominal aorta and the visceral, renal and iliac arteries. CONCLUSIONS: EBT with 140 slices and slice reconstruction every 2 mm offers a high z-axis resolution resulting in high-quality CT angiographies of the whole abdominal aorta and its branches.

Aged↗

[Clinical use of a new analytical method for the determination of bone density by means of quantitative computer tomography].

AIM: Evaluation of the clinical suitability of a new analytical method for the determination of bone mineral density (BMD) by means of SEQCT as well as a comparison with the established method. METHODS: In order to verify the stability of both systems, phantom measurements were performed on a lumbal spine torso as well as on 78 patients. 44 patients were examined by means of the established method and 34 according to the new method. Parallel measurements were possible in 15 patients. RESULTS: The phantom measurements proved a high stability of both methods. Regarding the absolute BMD the new method resulted in higher BMD values. This result was confirmed by parallel measurements in 15 patients. The new method demonstrated increased suitability due to less time consuming preparations. Dose reduced scan parameters could not be achieved in all patients, so that the time saving effect could not be considered. In these cases manual settings were required. CONCLUSION: A substitution of the established method for BMD measurement by means of SEQCT with the new method seems to be possible. However, the results will have to be corrected by the percentage of deviation from the default value of the quality phantom.

Absorptiometry, Photon↗

Quantification of color Doppler for the evaluation of tissue vascularization.

Assessment of tissue vascularization with color Doppler (CD) can improve differential diagnosis of tumors. Until now, measurement of flow velocities is restricted to conventional duplex ultrasound of single vessels or semiquantitative scoring of the vessel distribution in CD. We developed a new method for quantification of CD data in organs or tumors by statistical image analysis. Based on standardized image recording, data is acquired from the video output of any ultrasound scanner using a 24-bit color framegrabber in a personal computer. The digitized colors are recognized according to their position in the CD palette bar resulting in an 8-bit color image (number of identified pixels > 99.9%). Within the region of interest, statistics of the detected flow patterns are calculated. The color pixel density and the mean color value varies between recordings of the same image during subsequent systolic peaks with a SD of 10% and 2%, respectively, and within different sections of the same organ or tumor with 25% and 10-50%. This analysis can be used for comparative or longitudinal studies and an objective evaluation of CD in complex vascular formations such as tumors. Its diagnostic impact has already been demonstrated in clinical studies.

Blood Flow Velocity↗

3D MPRAGE evaluation of lesions in the posterior cranial fossa.

Standard spin-echo images of the posterior cranial fossa are usually impaired by pulsation artifacts. We evaluated a heavily T1 weighted MPRAGE sequence (TR/TE/alpha/TI = 10/4/10-15 degrees/200-350) for detection of intracerebral lesions in the posterior fossa in 11 patients. Overall quality of the MPRAGE images was superior due to the lack of pulsation artifacts, high S/N and excellent gray-white matter contrast. Lesion detection was better in one patient, equal in six and inferior in four patients compared to SE technique. A cerebellar metastasis (8 mm) in one patient was completely blurred from pulsation artifacts on the SE images. Whereas multiple small lesions (< or = 4 mm) with discrete contrast enhancement were missed on the MPRAGE images in three patients. We conclude, that the MPRAGE sequence yields high quality images with isotropic spatial resolution in a reasonable time. But MPRAGE with these parameters can not replace standard SE images in screening the posterior fossa, because of a decreased sensitivity in the detection of small contrast-enhancing lesions.

Adolescent↗

[The color-coded duplex sonography and contrast-enhanced magnetic resonance tomography of scintigraphically cold thyroid nodules].

In order to establish diagnostic criteria, colour-coded duplex sonography was performed on 40 patients who had a total of 43 operatively confirmed thyroid lesions which were scintigraphically "cold" (28 adenomas, 8 carcinomas, 4 cases of thyroiditis and 3 cysts). 32 of these patients also had MRT with T2- and T1-weighted images before and after injection of Gd-DTPA (0.1 mmol/kg). Adenomatous nodules and adenomas showed a peripheral vascular halo on colour-coded duplex sonography with a sensitivity of 96% and a specificity of 93%. Malignant lesions showed marked central vascularisation and on B-images irregular marginal structures. Adenomas and adenomatous nodules showed hyperintense areas on T1-weighted unenhanced MR images and/or homogeneous uptake in the lesion (sensitivity 100%, specificity 77%). Malignant lesions typically showed an irregular margin with increased contrast uptake on MRT. If sonography and colour-coded duplex sonography is unable to classify a lesion with any degree of assurance then MRT with Gd-DTPA enhancement should be performed.

Adult↗

[MR tomography of lung metastases with rapid gradient echo sequences. Initial results in diagnostic applications].

Rapid gradient echo sequences enable MR imaging (MRI) of pulmonary metastases with acquisition times of less than 1 s per slice. By optimization of this technique, density, T1- and T2-weighted images can be obtained (FLASH: TR 6.5 ms, TE2 = 3 ms, alpha = 10 degrees; T1w-Turbo-FLASH: TI 200 ms, TR 6.5 ms, TE2 = 3 ms, alpha = 10 degrees; T2w-Turbo-FLASH: TE1 = 50 ms, TR = 6.5 ms, TE2 = 3.5 ms; alpha = 10 degrees). In a prospective study 25 patients in whom pulmonary metastases were suspected were examined with three techniques in all three anatomical planes prior to surgery. All lung metastases revealed a high signal intensity on the FLASH as well as the T2w-Turbo-FLASH images, whereas vascular structures revealed a low signal intensity on the T2-weighted Turbo-FLASH images. Analysis regarding detection and correct number of lung metastases per patient with MRI compared with the histology revealed (n = 25): sensitivity of 82%, specificity 67%, positive predictive value of 95% and negative predictive value of 33%. While MRI does not currently have any diagnostic advantages over CT, the excellent differentiation of parenchymal lesions and vascular structures without the use of contrast medium and the variability of imaging planes are significant methodological advantages.

Adolescent↗

[Escape of hydrogen peroxide and oxygen from the root canal].

In vitro investigations demonstrate that hydrogen peroxide, like the oxygen emitted from the root canal, escapes into the area around the root. The amount measurable was dependent on the concentration, the amount of time that the hydrogen peroxide was left in the root canal and the patency of the foramen apicale. The growth of the Staphylococcus aureus (SG 511) was restricted in the area around those roots whose root canal contained a 5% solution of hydrogen peroxide.

Dental Pulp Cavity↗

[Neuroradiology of the normal and pathological anatomy of the rat brain.--III Morphology and growth behaviour of experimental brain tumours following radiation therapy (author's transl)].

Radiation induced (30 Gy) morphological changes of experimental malignant brain tumors, which were produced by chemical carcinogenesis, were investigated by microangiography and correlated with the histological findings in 62 BD-IX-rats. In randomized groups the investigations were performed 2, 3, 6 and 8 weeks after the radiation was finished. Morphologically different reactions could be differentiated: remissions or partial recovery of the tumors, rest or recurrent tumor and uninfluenced tumor growth. The characteristic findings, the reasons for different courses and possible conclusions concerning the radiotherapeutical effect are discussed.

Animals↗

[Neuroradiology of the normal and pathological anatomy of the rat brain. II Microangiographic investigations of the vascularisation of transplanted malignant brain tumors (author's transl)].

70 BD-IX rats, in which chemically induced mixed gliomas have been transplanted intracerebrally, were investigated by microangiography. The pattern and the degree of tumor vascularisation of all animals was correlated with the histological findings. Depended on the type of the tumor different localisations of tumor growth could be found: G XII-gliomas preferred the juxtaventricular region and subarachnoid space whereas GL 2.2-gliomas mainly grew as solid intracerebral space occupying lesions. Microangiograms of all tumor stages from the 14th to 42nd day after transplantation revealed a typical vascular pattern consisting of lacunar, glomerulose and netlike vessels. Further, necrosis, bleedings into the tumor, and irregularities of the capillary network could be demonstrated. The volume, age and vascularisation of the tumors are correlated and the results are discussed with regard to the principles of tumor growth and malignancy.

Animals↗

Quantitative characterization of color Doppler images: reproducibility, accuracy, and limitations.

A computer-based quantitative analysis for color Doppler images of complex vascular formations is presented. The red-green-blue-signal from an Acuson XP10 is frame-grabbed and digitized. By matching each image pixel with the color bar, color pixels are identified and assigned to the corresponding flow velocity (color value). Data analysis consists of delineation of a region of interest and calculation of the relative number of color pixels in this region (color pixel density) as well as the mean color value. The mean color value was compared to flow velocities in a flow phantom. The thyroid and carotid artery in a volunteer were repeatedly examined by a single examiner to assess intra-observer variability. The thyroids in five healthy controls were examined by three experienced physicians to assess the extent of inter-observer variability and observer bias. The correlation between the mean color value and flow velocity ranged from 0.94 to 0.96 for a range of velocities determined by pulse repetition frequency. The average deviation of the mean color value from the flow velocity was 22% to 41%, depending on the selected pulse repetition frequency (range of deviations, -46% to +66%). Flow velocity was underestimated with inadequately low pulse repetition frequency, or inadequately high reject threshold. An overestimation occurred with inadequately high pulse repetition frequency. The highest intra-observer variability was 22% (relative standard deviation) for the color pixel density, and 9.1% for the mean color value. The inter-observer variation was approximately 30% for the color pixel density, and 20% for the mean color value. In conclusion, computer assisted image analysis permits an objective description of color Doppler images. However, the user must be aware that image acquisition under in vivo conditions as well as physical and instrumental factors may considerably influence the results.

Algorithms↗