PubMed Health⌕ Search

Biomedical subjects

Göran Johansson

Publications and source records attributed to Göran Johansson.

12 recordsLinked to original sources

Vectorcardiographic ST deviations related to increased heart rate in the absence of ischemia in an experimental pig model.

The electrocardiographic ST segment may change when heart rate (HR) increases. We aimed to analyze vectorcardiographic ST relation and myocardial conditions during controlled HR increases in anesthetized pigs. The relative parameters ST change vector magnitude and ST change vector angle were calculated at paced HRs ranging from 85 to 175 beats per minute. ST change vector magnitude increased from baseline 6.3 +/- 1.3 to 26.0 +/- 3.1 microV (P < .01; range, 4-50 microV) at HR 175 beats per minute with similar changes in ST change vector angle, whereas the absolute parameter ST vector magnitude demonstrated a heterogeneous pattern without any systematic relation to HR changes. Microdialysis results from left ventricular wall, with analysis of glucose, lactate, and pyruvate, showed no sign of ischemia during pacing. Potassium concentrations did not change during pacing. We conclude that significant HR-related ST vector changes can occur in the absence of myocardial ischemia.

Animals↗

The effect of lung inflation on absolute ventricular volume measurement by conductance.

BACKGROUND: Conductance catheter in vivo ventricular volume measurements during lung ventilation may provide important information on left ventricular (LV) function. Breathing potentially may alter parallel conductance (V(c)), complicating interpretation of the conductance-derived volume signals. The effects of controlled positive pressure lung inflation (PPLI) on measured parallel conductance with dual-field conductance volumetry were investigated. METHODS: Eight anaesthetized pigs were instrumented with an LV dual-field conductance volumetry catheter. V(c) was measured repeatedly, using the hypertonic saline injection method, at three different levels of lung insufflation: continuous positive airway pressure (PPLI) 0, 5, and 10 cm H(2)O. RESULTS: V(c)s measured at PPLI 0, 5 and 10 cm H(2)O were 70.9 +/- 4.8, 70.7 +/- 5.5 and 70.5 +/- 5.9 ml, respectively. The corresponding uncalibrated end-diastolic volumes (EDV(u)) were 115.5 +/- 7.1, 117.0 +/- 7.5 and 117.5 +/- 7.7 ml, respectively. Mean coefficients of variance for V(c) and EDV(u) at all three PPLI levels were 3.8% and 1.25%, respectively. DISCUSSION: Several levels of PPLI demonstrated no systematic change in parallel conductance for LV dual-field conductance volume signal. We concluded that lung inflation at these levels does not generate changes in V(c).

Animals↗

ST-segment deviations during pacing-induced increased heart rate in patients without coronary artery disease.

INTRODUCTION: In order to interpret ST-segment changes as an indicator of ischemia in patients with higher heart rates (HRs), the relation between ST-segment levels and HR needs to be well defined in subjects without coronary artery disease. METHODS: Eighteen patients with normal ECGs in the catheterization laboratory, after radiofrequency ablation of AV nodal re-entry tachycardia or an accessory pathway were included. Computerized online vectorcardiography (VCG) was performed during step-wise atrial pacing-induced increases in HR up to 150 beats min(-1) (bpm). The ST-vector magnitude (ST-VM) and the relative ST change vector magnitude (STC-VM) were analysed at the J point, J + 20 and J + 60 ms. RESULTS: There was no divergence in the course of ST-VM or STC-VM based on J point + 0, 20, or 60 ms during increasing HR. The STC-VM mean values increased progressively during increases in HR above 100 bpm, with an average increase in STC-VM of 15-20 microV per 10 bpm increases in HR. The ST-VM response during HR increases showed a heterogeneous and unpredictable pattern. CONCLUSION: The STC-VM increases linearly with rising HRs above 100 bpm. The STC-VM can exceed widely recognized ischemic thresholds during higher HRs in the absence of ischemia. The choice of J point time to ST-VM measurements as tested here is not important for the STC-VM relation to HR at these HR levels. Further clinical testing is needed to improve the diagnostic specificity of STC-VM measurements during increased HRs.

Adult↗

Myocardial systolic function increases during positive pressure lung inflation.

Lung inflation with positive airway pressure may have rapid and dynamic effects on myocardial contractile function. We designed this study to assess the magnitude and time to onset of myocardial function changes during the initiation of single positive pressure lung inflation at clinically relevant inflation pressures. In 8 anesthetized 40-kg pigs, left ventricular pressures and volumes were measured directly (conductance volumetry). A 15 cm H2O airway pressure plateau with lung inflation (PPLI-15) was performed, and 2 single beats from that sequence, one from resting apnea at zero airway pressure and the second from the point when the lungs were first maximally inflated, were selected for analysis. Systolic function variables for zero airway pressure and PPLI-15 were analyzed. Systolic elastance, derived from bilinear time-varying elastance curves, increased approximately 15% during PPLI-15 from zero airway pressure. This agreed with other systolic function variables that identified an increase in left ventricular contractile function for the lung inflation beat. Serial measurements of myocardial function should be conducted with constant airway pressure and lung inflation conditions.

Animals↗

Measuring non-Gaussian fluctuations through incoherent cooper-pair current.

We study a Josephson junction (JJ) in the regime of incoherent Cooper-pair tunneling, capacitively coupled to a nonequilibrium noise source. The current-voltage (I-V) characteristics of the JJ are sensitive to the excess voltage fluctuations in the source, and can thus be used for wideband noise detection. Under weak driving, the odd part of the I-V can be related to the second cumulant of noise, whereas the even part is due to the third cumulant. After calibration, one can measure the Fano factors for the noise source, and get information about the frequency dependence of the noise.

Journal Article↗

Local metabolic effects of dopexamine on the intestine during mesenteric hypoperfusion.

This self-controlled experimental study was designed to test the hypothesis that dopexamine, a synthetic catecholamine that activates dopaminergic (DA-1) and beta2-adrenergic receptors, improves oxygenation in the jejunal mucosa during intestinal hypotension. In six normoventilated barbiturate-anesthetized pigs, controlled reductions in superior mesenteric arterial pressure (PSMA) was obtained by an adjustable clamp around the artery. Dopexamine infusions (0.5 and 1.0 microg.kg(-1).min(-1)) were administered at a freely variable PSMA (i.e., with the perivascular clamp fully open) and at a PSMA of 50 mmHg and 30 mmHg. We continuously measured superior mesenteric venous blood flow (QMES; transit-time ultrasonic flowmetry), jejunal mucosal perfusion (laser Doppler flowmetry), and tissue oxygen tension (PO2TISSUE; microoximetry). Jejunal luminal microdialysate of lactate, pyruvate, and glucose were measured every 5 min. Measurements of mucosal PCO2 (air tonometry), together with blood sampling and end-tidal PCO2 measurements, enabled calculations of pHi and PCO2 gap. Dopexamine reduced mesenteric vascular resistance and increased QMES at a PSMA of 50 mmHg and 30 mmHg. At a PSMA of 30 mmHg, dopexamine increased mesenteric oxygen delivery but did not influence mesenteric oxygen uptake or extraction. In this situation, dopexamine had no beneficial effect on jejunal mucosal blood flow. On the contrary, dopexamine increased mesenteric net lactate production and PCO2 gap, whereas PO2TISSUE and pHi decreased. Jejunal luminal microdialysate data demonstrated an increased lactate concentration and a pattern of decreased glucose concentration and increased luminal lactate-pyruvate ratio. These negative metabolic effects of dopexamine should be taken into account in situations of low perfusion pressures.

Adrenergic beta-Agonists↗

Full counting statistics of multiple Andreev reflection.

We derive the full counting statistics of charge transfer through a voltage biased superconducting junction. We find that, for measurement times much longer than the inverse Josephson frequency, the counting statistics describes a correlated transfer of quanta of multiple electron charges, each quantum associated with the transfer of a single quasiparticle. An expression for the counting statistics in terms of the quasiparticle scattering amplitudes is derived.

Journal Article↗

Intracoronary beta2 receptor activation induces dynamic local t-PA release in the pig.

To investigate beta2 -adrenergic agonist-mediated effects on coronary fluxes of local fibrinolytic factors, healthy anaesthetised and instrumented pigs (n=10) were studied during infusion of isoprenaline (IPR) into the left main coronary artery. Coronary net fluxes of total t-PA antigen, active t-PA and total PAI-1 antigen were determined at baseline and at 3, 5, 7 and 10 minutes of IPR infusion. During IPR, net release of total t-PA increased in a biphasic pattern with transiently high levels at 3 (+440 %) and 7 minutes (+620%) and returned towards baseline at 10 minutes. Net coronary release of active t-PA increased with maximum levels at 3 minutes (+50%). Baseline coronary net flux of total PAI -1 showed a decrease which was most pronounced at 10 minutes. To conclude, a fast beta2 agonist-mediated local release of t-PA into the coronary vasculature was demonstrated. For total t-PA, this response was characterised by a biphasic release profile.

Adrenergic Agonists↗

Effects of dopexamine and positive end-expiratory pressure on intestinal blood flow and oxygenation: the perfusion pressure perspective.

OBJECTIVE: To evaluate the net effects of the concomitant use of positive end-expiratory pressure (PEEP) and dopexamine on intestinal tissue perfusion and oxygenation during predefined artificial reductions in intestinal perfusion pressure (IPP). DESIGN: Prospective, self-controlled, experimental study. SETTING: University hospital research laboratory. SUBJECTS: Seven female pigs. MEASUREMENTS: In barbiturate-anesthetized pigs, we measured mesenteric blood flow (QMES) [by transit-time ultrasonic flowmetry], jejunal mucosal perfusion (by laser Doppler flowmetry), and tissue PO(2) (by microoximetry). Based on blood sampling, we calculated the intestinal net lactate production and oxygenation. INTERVENTIONS: These measurements and calculations were performed at three predefined and controlled IPP levels, which were obtained by an adjustable clamp around the superior mesenteric artery. At each IPP level, measurements were performed prior to and during PEEP (10 cm H(2)O), both with and without simultaneous dopexamine infusions (at 0.5 and 1.0 microg/kg/min). RESULTS: Within the IPP range of 77 to 33 mm Hg, intestinal perfusion and oxygenation were maintained irrespective of whether PEEP and/or dopexamine were applied or not. At IPP < 33 mm Hg, QMES and intestinal oxygenation deteriorated, resulting in regional net lactate production. At this IPP range, tissue oxygen perfusion was entirely pressure-dependent, and even small reductions in IPP led to prominent increases in intestinal net lactate production. Dopexamine did not modify this pattern. CONCLUSIONS: We describe maintained intestinal tissue oxygen perfusion within a wide perfusion pressure range. Within this perfusion pressure range, PEEP did not induce any adverse regional circulatory effects. Below the perfusion pressure range for effective autoregulation, intestinal tissue oxygen perfusion deteriorated, and regional ischemia occurred. In this situation, dopexamine was unable to counteract IPP-dependent decreases in intestinal tissue oxygen perfusion. The regional ischemic threshold can be defined either as an IPP of < 33 mm Hg or as an intestinal tissue PO(2) of < 45 mm Hg.

Adrenergic beta-Agonists↗

Full frequency back-action spectrum of a single-electron transistor during qubit readout.

We calculate the spectral density of voltage fluctuations in a single-electron transistor (SET), biased to operate in a transport mode where tunneling events are correlated due to Coulomb interaction. The whole spectrum from low frequency shot noise to quantum noise at frequencies comparable to the SET charging energy (EC/h) is considered. We discuss the back-action during readout of a charge qubit and conclude that single-shot readout is possible using the radio-frequency SET.

Journal Article↗

Method of preload reduction during LVPVR analysis of systolic function: airway pressure elevation and vena cava occlusion.

BACKGROUND: A graded preload reduction during analysis of the left ventricular pressure-volume relationship (LVPVR) is required for derivation of end-systolic elastance (Ees) and preload recruitable stroke work (PRSW). The authors aimed to measure serial changes in these systolic function parameters before and during planned circulatory interventions using two different methods of preload alteration: a positive airway pressure plateau (APP) and inferior vena cava occlusion (IVCO). METHODS: In eight animals, measurements were made at 38 degrees, 30 degrees, 32 degrees, 34 degrees, and posthypothermia 38 degrees C. In an additional eight animals, isoflurane, adrenaline, and aorta occlusion (balloon catheter occluder) were administered in series, each with a preintervention control measurement. Left ventricular volume was measured by conductance. Paired measurements of the systolic function parameters Ees and PRSW, each derived with two preload methods, were analyzed for bias. RESULTS: Circulatory alterations were achieved with the temperature, isoflurane, adrenaline, and aorta occlusion interventions. Measured changes in Ees and PRSW from control to intervention showed a strong correlation and no significant bias for APP in relation to IVCO. The APP-derived absolute values for Ees and PRSW demonstrated a consistent positive bias compared with IVCO. CONCLUSION: The APP method for preload reduction during LVPVR analysis detected changes in Ees and PRSW during the circulatory interventions in this model that were not different than those detected using another preload reduction method, IVCO. APP and IVCO are not interchangeable methods for preload reductions during LVPVR absolute quantitation of systolic function, and each needs to be used serially.

Analysis of Variance↗

Do patients with primary fibromyalgia have an altered muscle sympathetic nerve activity?

This study was performed to test the existing notion that an increased muscle sympathetic nerve discharge is part of the underlying mechanism for the chronic pain syndrome of primary fibromyalgia. Muscle sympathetic nerve activity was recorded in the peroneal nerve in eight patients with primary fibromyalgia and eight age-matched controls. No difference in baseline sympathetic activity was observed between patients and controls. Furthermore, patients did not show exaggerated sympathetic nerve responses to static handgrip or jaw muscle contractions, postcontraction ischemia or mental stress. Thus the results do not indicate muscle sympathetic nerve overactivity in primary fibromyalgic patients.

Adult↗