PubMed Health⌕ Search

Biomedical subjects

Günter Layer

Publications and source records attributed to Günter Layer.

9 recordsLinked to original sources

Circadian rhythm of fasting and postprandial portal blood flow in cirrhosis.

OBJECTIVE: To examine the relationship of both the unstimulated and the postprandial portal blood flow (PVF) to the time of day and to determine its intra-individual reproducibility over time in patients with liver cirrhosis. MATERIAL AND METHODS: In 24 cirrhotic patients, 27 PVF measurements were performed during 24 h on day 0 and day 7 using Doppler ultrasound. Three standard liquid meals were given orally. On day 7, the baseline hepatic venous pressure gradient (HVPG) was also measured. RESULTS: Circadian area under the time curve of PVF was highly reproducible within individuals (r=0.959, p<0.001). It did not correlate with HVPG. Cosinor analysis showed a significant circadian rhythm of PVF (acrophase at 11:44 and amplitude of 9.44%). Maximal postprandial increase in PVF was significantly higher in the morning than at noon or in the evening. CONCLUSIONS: PVF is subject to a circadian rhythm and postprandial portal hyperemia shows a diurnal variability. Both are highly reproducible.

Circadian Rhythm↗

Colorectal polyps: detection with dark-lumen MR colonography versus conventional colonoscopy.

PURPOSE: To prospectively compare dark-lumen magnetic resonance (MR) colonography with conventional colonoscopy in the detection of colorectal polyps. MATERIALS AND METHODS: Local ethical committee approval and informed consent were obtained. One hundred consecutive patients (56 men, 44 women; mean age +/- standard deviation, 67.7 years +/- 14.7; range, 25-82 years) who were referred for conventional colonoscopy from January 2003 to January 2004 underwent MR colonography and conventional colonoscopy after standard precolonoscopic bowel cleansing. Colonoscopy was performed immediately after MR colonography. For MR colonography, the colon was filled with approximately 2000 mL of tap water. Imaging was performed with a 1.5-T MR unit with patients in the prone position. A T1-weighted three-dimensional volumetric interpolated breath-hold sequence was performed before and 75 seconds after intravenous administration of 0.2 mmol gadobenate dimeglumine per kilogram of body weight. Results of MR colonography were analyzed on a per-polyp and per-patient basis. Findings at colonoscopy were used as the reference for determining accuracy, sensitivity, specificity, and positive and negative predictive values of MR colonography. RESULTS: Of 100 patients recruited for study, 92 (52 men, 40 women; mean age, 61.5 years +/- 14.5; range, 25-82 years) underwent complete MR and conventional colonoscopy examinations. Forty-three of the 92 patients (47%) had normal findings at conventional colonoscopy. In the other 49 patients (53%), conventional colonoscopy depicted 107 polyps (82 adenomas, 25 hyperplastic polyps) and seven carcinomas. At per-polyp analysis, sensitivity of MR colonography in the detection of adenomatous polyps was 100% for polyps at least 10 mm in diameter and 84.2% for polyps 6-9 mm in diameter. At per-patient analysis, the accuracy of MR colonography was 93.1% (sensitivity, 89%; specificity, 96%) if detection of adenomatous polyps of all sizes was considered. CONCLUSION: Dark-lumen MR colonography is a promising modality with high accuracy for detecting colorectal polyps larger than 5 mm in diameter.

Adult↗

[MRI in gastrointestinal diseases].

Magnetic resonance imaging (MRI) has been called the most important development in medical diagnosis since the discovery of the X-ray more than 100 years ago. The effectiveness of MRI has been expanded to a variety of gastrointestinal disorders. The gastroenterologist's attention is currently focused on biliopancreatic and bowel diseases. Magnetic resonance cholangiopancreatography (MRCP) has become a competitive replacement for diagnostic endoscopic retrograde cholangiopancreatography (ERCP) in a variety of hepatobiliary and pancreatic diseases. MR enteroscopy has the potential to become the preferred method for evaluating the entire small bowel, while on the other hand virtual colonoscopy is far from being promoted as a tool for general screening purposes in suspected colon diseases. In summary, whether or not the survival of endoscopy is under debate, MRI could mark a historic turning point in gastroenterology. So, MRI hardware might interdisciplinarily be used by, e. g., radiologists and gastroenterologists.

Cholangiopancreatography, Endoscopic Retrograde↗

ERCP and MRCP in the differentiation of pancreatic tumors.

The introduction of endoscopic retrograde cholangiopancreatography (ERCP) in the early 1970s provided gastroenterologists with a number of diagnostic as well as therapeutic possibilities for examining biliopancreatic systems. In the meantime, magnetic resonance cholangiopancreatography presents a non-invasive alternative to diagnostic ECRP providing the advantage of a lower rate of possible complications. This article addresses the two methods presently available for differentiating pancreatic tumors. The objective of this article is to describe the advantages and disadvantages as well as the possibilities inherent in both methods.

Adenoma, Islet Cell↗

Silent and apparent cerebral embolism after retrograde catheterisation of the aortic valve in valvular stenosis: a prospective, randomised study.

BACKGROUND: In most patients, severity of valvular aortic stenosis can be accurately assessed non-invasively by echocardiography. However, retrograde catheterisation of the aortic valve is often undertaken. This procedure has a potential risk of neurological complications, with an unknown incidence of clinically silent embolism. We aimed to establish the frequency of clinically apparent and silent cerebral embolism after this procedure. METHODS: We prospectively randomised 152 consecutive patients with valvular aortic stenosis at a German university hospital to receive either cardiac catheterisation with (n=101) or without (n=51) passage through the aortic valve. Patients underwent cranial MRI and neurological assessment within 48 h before and after the procedure to assess cerebral embolism. Controls were 32 patients without valvular aortic stenosis who underwent coronary angiography and laevocardiography. FINDINGS: 22 of 101 patients (22%) who underwent retrograde catheterisation of the aortic valve had focal diffusion-imaging abnormalities in a pattern consistent with acute cerebral embolic events after the procedure; three of these patients (3%) had clinically apparent neurological deficits. By contrast, none of the patients without passage of the valve, or any of the controls, had evidence of cerebral embolism as assessed by MRI. INTERPRETATION: Patients with valvular aortic stenosis who undergo retrograde catheterisation of the aortic valve have a substantial risk of clinically apparent cerebral embolism, and frequently have silent ischaemic brain lesions. Patients should be informed about these risks, and this procedure should be used only in patients with unclear echocardiographical findings when additional information is necessary for clinical management.

Aortic Valve↗

Phase II study of photodynamic therapy and metal stent as palliative treatment for nonresectable hilar cholangiocarcinoma.

BACKGROUND: The combination of photodynamic therapy and biliary drainage by plastic endoprosthesis insertion has produced promising results in the treatment of nonresectable hilar cholangiocarcinoma. The feasibility and efficacy of intraductal photodynamic therapy with subsequent biliary drainage by self-expandable metal stent insertion were evaluated in a prospective phase II study. METHODS: Twenty-four patients were treated with photodynamic therapy after sensitization with porfimer sodium. A plastic endoprosthesis was inserted immediately thereafter and replaced by a metal stent 4 weeks later. A retrospectively analyzed group of 20 patients treated only with biliary drainage served as a historical control group. RESULTS: In 19 of the 24 patients, insertion of a metal stent was technically feasible. The 30-day and 60-day mortality rates were 0%. A significant decrease in serum bilirubin was noted in all patients and quality of life remained stable throughout follow-up. Mean and median survival were, respectively, 15.9(3.1) and 9.9: 95% CI [6.4, 13.4] months after photodynamic therapy. In the control group, mean and median survival were, respectively, 12.5(3.4) and 5.6: 95% CI [3.7, 7.6] months, which was not statistically significantly different from the photodynamic therapy group. CONCLUSIONS: Photodynamic therapy with consecutive biliary drainage by insertion of a self-expandable metal stent is feasible. With respect to the small benefit in overall survival, randomized controlled trials are warranted.

Aged↗

Hepatocellular carcinoma: detection with gadolinium- and ferumoxides-enhanced MR imaging of the liver.

PURPOSE: To test the hypothesis that the accuracy of gadolinium- and ferumoxides-enhanced magnetic resonance (MR) imaging is different in small (< or =1.5-cm) and large (>1.5-cm) hepatocellular carcinomas (HCCs). MATERIALS AND METHODS: Forty-three consecutive patients with chronic liver disease were enrolled in this study. The imaging protocol included unenhanced breath-hold T1-weighted fast field-echo sequences, unenhanced respiratory-triggered T2-weighted turbo spin-echo (SE) sequences, dynamic gadolinium-enhanced T1-weighted three-dimensional turbo field-echo sequences, and ferumoxides-enhanced T2-weighted turbo SE sequences. Images of each sequence and two sets of sequences (ferumoxides set and gadolinium set) were reviewed by four observers. The ferumoxides set included unenhanced T1- and T2-weighted images and ferumoxides-enhanced T2-weighted turbo SE MR images. The gadolinium set included unenhanced T1- and T2-weighted images and dynamic gadolinium-enhanced three-dimensional turbo field-echo MR images. In receiver operating characteristic (ROC) curve analysis, the sensitivity and accuracy of the sequences were compared in regard to the detection of all, small, and large HCCs. RESULTS: Imaging performance was different with gadolinium- and ferumoxides-enhanced images in the detection of small and large HCCs. For detection of small HCCs, the sensitivity and accuracy with unenhanced and gadolinium-enhanced imaging (gadolinium set) were significantly (P =.017) superior to those with unenhanced and ferumoxides-enhanced imaging (ferumoxides set). The area under the composite ROC curves, or A(z), for the gadolinium set and the ferumoxides set was 0.97 and 0.81, respectively. For large HCC, the ferumoxides set was superior compared with the gadolinium set, but this difference was not statistically significant. Analysis of all HCCs demonstrated no significant differences for gadolinium- and ferumoxides-enhanced imaging. CONCLUSION: For the detection of early HCC, gadolinium-enhanced MR imaging is preferred to ferumoxides-enhanced MR imaging because the former demonstrated significantly greater accuracy in the detection of small HCCs.

Adult↗

Impact of the continuous infusion of Levovist on color Doppler sonography in portal hypertension.

OBJECTIVE: This study was undertaken to investigate to what extent continuous infusion of a galactose-based microbubble contrast agent (Levovist) allows evaluation of the portal vascular system in patients with portal hypertension and for whom baseline unenhanced color Doppler sonography was nondiagnostic. SUBJECTS AND METHODS: We performed color Doppler sonography at baseline and during IV Levovist infusion (4 g, 300 mg/min). First, we measured the duration of portal vein visualization during Levovist infusion in 15 patients in whom unenhanced color Doppler sonography failed to show the portal confluence from a subcostal view. This duration of improved portal conspicuity was termed "diagnostic window." We then compared in 30 patients enhanced color Doppler sonographic findings with conventional imaging methods, including portography (n = 14), helical CT (n = 4), or gadolinium-enhanced MR angiography (n = 12), and we recorded the investigator's confidence in the color Doppler sonographic result before and after Levovist infusion. RESULTS: The diagnostic window achieved by the Levovist infusion was 13.6 +/- 0.9 min. At baseline, color Doppler sonography was nondiagnostic in 19 patients. The diagnostic confidence level was low in all the remaining 11 patients. During Levovist infusion, color Doppler sonography remained nondiagnostic only in two of 30 patients. The confidence level was low in five patients and high in 23 patients. In 26 of these 28 patients, echo-enhanced color Doppler sonographic findings were confirmed by reference methods. CONCLUSION: The continuous infusion of Levovist achieved a sufficient echo enhancement from the portal vascular bed and allowed a valid diagnostic color Doppler sonographic examination in portal hypertensive patients for whom color Doppler sonography would otherwise be nondiagnostic.

Adult↗